Proposed Tech Specs Supporting Implementation of Revised 10CFR20
ML20058L682
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 12/09/1993
From:
DETROIT EDISON CO.
To:
Shared Package
ML20058L674 List:
References
NUDOCS 9312170139
Download: ML20058L682 (3)


Text

.. _.

e

. Enclosure 2 to h

NRC-93-0143 Page 4

(

f l

l l

DOCKET NO. 50-16 1

APPENDIX A j

LICENSE NO. DPR-9' i

FOR l

ENRICO FERMI _ ATOMIC POWER PLANT _

UNIT NO. 1 9

l l

s AmendmentNo./

l

~!

.)

1 i

l i

-I l

9312170139 931209 PDR ADOCK 05000016 P

PDR

.j

. - ~.

l-t 5-to I

'NRC 93 0143 Page 5 e

t j

i t

4 APPIEDIX A TEKEEIChL SMK3FICNfIGE F5WE 1 4

Facility License No. DER-9 t

i A.

DEFINITIGE

)

1.

Phvnir-21 marrier - Fences constructed of No. ?.1 AWG, or heavier, wire fabric, topped by three or more strands of barbed wire on -

brackets angled outward, with an overall height of not less than seven feet, including the barbed. wirer or natural obstacles or manmade structures providing an equivalent degree of resistance to penetration.

4 2.

Protected Area - An area encongassed by physical. barriers and to which access is controlled. (This area.is consistent with definition of a Restricted Area). -

- -..,m,s.,,

to cpg.a.o.too3 3.

Omtodian - The custodian is the individual responsible for directing the activities at the site, seeing that the activities are done in a safe manner and in coupliance with the Y%chnical Specifications, and reporting these activities to the NRC.

4. - Authorized Permcm - A person having written permission, which may take the form of composite lists of names, from the Qastodian or -

1 Dalegate to enter a Protected Area..Any individual escorted by.

I such a person is also authorized.

i i

5.

Written order - As used herein the term " written order" shall mean a normal plant operating or maintenance order which has been personally approved and signed by the'meMian or Delegate.

6.

Am=411- - Tests, surveys, and/or ins' ectims which' are.

p conducted periodically to ensure that a given systen, s2 system or ww.t will perform its intended function. - Surveillance activities are initiated by written orders issued by the Qastodian-or Delegate. Sarveillance shall be perforned within a specified '

time interval with a saximum allowable extension not to amoeed 25%

of the surveillance interval, unless otherwise stated.

j 7.

Licensee Event Beort (IJEt). Rgortable - An IER is required for one of the following events:

1 1

AmendmentNo./

.... ~.-.2-

.~...

.m

Enclosure:

2 to 2

NRC-93-0143 Page 6 E.

FML AfD REERIR EDIIDIIE 1.

Access - Normal access to the Fuel and Repair Building shall be limited to the door at the southwest corner of the building. -A11:

other external access doors shall be locked from the inside or permanently closed unless they are needed for work being carried -

out. At least one door shall be operable from the inside.

2.

Drains - All drains are connected to sungs. The sung pumps discharge to the liquid waste holdup systen. The pungs sey be..

diswreected or decomissioned when no longer needed for disposing of radioactive waste.

F.

MMTE DISPOSPL S[RUEIIZAIEES Prior to comencing discharge of any liquid effluent, sonitoring facilities in the liquid waste di & 1 system shall be provide $ to ascertain the concentration of radioactivity. If a ra$iation.

l instrument is out of service such that the affluent cannot properly be-j monitored, discharge of the effluent shall be discontinued..

j

./

During periods when radioactive effluents are being discharged, the j

discharge radiation monitor shall be checked for response once a week with a source and shall be calibrated at least once every six months or i

before each discharge batch, l

l 1.

Licpid Effinets - Radioactive waste discharges' to offsite j

, locations shall not exceed the limits given in 19T R20, Appendix B, Table 19, Colunn 2, on an instantaneous basis.

'A 2.

Mamous Effinants - Gaseous effluents sha'.1 not result in offsite j

ground level concentrations exceeding.the limits given in 19CFR29, Appendix B, Table Gh Coltam 1, on an instantaneous basis, l

7,.

i G.

EEWIKIEENEL 1ERVEIIIAIEES A nunber of Indicator Stations have been established where it is -

estimated that maximum concentrations of radioactive saterial.

discharged from the plant would occur (Figure G-1). Background I

sanpling stations shall be located at Swan Creek (at Dixie Righway),

I Detroit and Monroe raw city water and Fermi Plant raw water saspling

.I stations.

'ho different regimes of sanpling and analysis shall be utilized. A j

sumary of these regimes is given in Table G-1.

j i

i j

5 Amen'dmentNo.g

..~...

._