BASES Thermal Marain/ Low Pressure (Continued)

The trip is. initiated whenever.the reactor coolant system. pressure signal

-drops below either 1850 psia or a computed value as described below, whichever-L

.is. higher..-The computed value is a function of the higher of AT power or 1

neutron power, reactor inlet temperature,.the number of reactor coolant pumps operating and the AXIAL SHAPE INDEX. The minimum value of reactor coolant J

flow rate, the' maximum AZIMUTHAL POWER TILT and the maximum CEA deviation permitted.for continuous operation are assumed in the generation of this trip

. function..In addition, CEA group sequencing in accordance with Specifications 3.1.3.5 and 3.1.3.6 is assumed.

Finally, the maximum insertion of CEA banks

.which can occur during any anticipated operational-occurrence prior to a-Power i

Level-High. trip is assumed.

Thermal: Margin / Low Pressure trip setpoints are derived from the core t

' safety limits through application of appropriate allowances for equipment l

response time measurement uncertainties-.and processing error.

A safety margin

.is provided which includes:. an allowance of 5% of RATED THERMAL POWER to compensat.e-for potential power measurement error; an allowance.of 2*F to compensate.for potential temperature measurement uncertainty; and a further allowance of'74 psi to compensate for. pressure measurement error, trip system l

processing-error, and time delay associated with providing effective termina-tion of the occurrence that exhibits the most rapid decrease in margin to the -

safety limit.' The 74. psi. allowance is made up of a 5 psi bias, a 19 psi l

l I

pressure measurement allowance and a 50 psi time delay allowance.

O

. Loss of Turbine

- A' Loss of Turbine trip causes a direct reactor trip when operating above i

15% of RATED THERMAL. POWER.- This trip provides turbine protection, reduces the severity of the' ensuring transient and helps avoid the lifting of the main R

steam line safety valves during the ensuing transient, thus extending the service life of these values. No credit was taken in the accident analyses for operation of this trip.- Its functional capability at the specified trip setting is required to enhance the overall reliability of the Reactor Protec-tion System, i

L1 l

MILLSTONE - UNIT 2 B 2-7 Amendment No. 3, A2, 139

.