l l

TABLE 1 A SEM1 ANNUAL SUMMATION OF GASEOUS RELEASES ALL AIRBORNE EFFLUENTS OUARTERS 1 AND 2,1992 FIRST SECOND EST TOTALS TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR %

A. FISSION AND ACTIVATION GASES

1. TOTAL RELEASE CURIES 2.72E+02 3.44E+01 20
2. AVERAGE RELEASE RATE FOR PERIOD pCl/SEC 3.46E+01 4.3BE+00
3. PERCENT OF TECH SPEC LIMIT N/A N/A B. RADIO'ODINES
1. TOTAL IODINE-131 CURIES 1.93E-04 2.65E-04 23
2. AVERAGE RELEASE RATE FOR PERIOD pCl/SEC 2.45E-05 3.37E-05
3. PERCENT OF TECH SPEC LIMIT N/A N/A O. PARTICULATES
1. PARTICULATE (HALF-LIVES > 8 DAYS)

CURIES 6.25E-07 2.06E-05 30

2. AVERAGE RELEASE RATE FOR PERIOD pCi/SEC 7.95E-08 2.63E-06
3. PERCENT OF TECH SPEC LIMIT N/A N/A
4. GROSS ALPHA RADIOACTIVITY CURIES 1.96E-06 1.28E-06 I

D. TR! TIUM

1. TOTAL RELEASE CURIES 7.40E+00 1.70E+01 14
2. AVERAGE RELEASE RATE FOR PERIOD vCi/SEC 9.42E-01 2.16E+00
3. PERCENT OF TECH SPEC LIMIT N/A N/A i Callaway Plant Safety Analysis Calculation 87-063-00 PAGE 1 OF 1 I

9310040080 930924 II PDR ADOCK 05000483 [-,,

R PDR ks

TABLE 1B SOAIANNUAL AIRBORNE CONTINUOUS AND BATCH RELEASES GROUND LEVEL RELEASES FISSION GASES, IODINES, AND PARTICULATES QUARTERS 1 AND 2,1992 CONTINUOUS RELEASES BATCH RELEASES FIRST SECOND FIRST SECOND NUCLIDE UNIT QUARTER QUARTER QUARTER QUARTER

1. FISSION GASES KR-85M CURIES 1.50E-01 0.00E+00 1.27E-03 0.00E+00 KR-85 CURIES 2.13E+01 8.68E+00 3.29E+00 3.13E+00 KR-87 CURIES 1.86E-01 0.00E+00 0.00E+00 0.00E+00 KR-88 CURIES 3.71E-01 0.00E+00 8.03E-04 0.00E+00 XE-131M CURIES 0.00E+00 1.48E+00 1.54E+00 1.90E-01 XE-133 CURIES 1.09E+02 3.45E+00 1.30E+02 1.73E+01 XE-133M CURIES 1.05E-01 0.00E+00 1.21 E+00 0.00E+00 XE-135 CURIES 4.57E+00 0.00E+00 3.72E-01 1.02E-01 AR-41 CURIES 0.00E+00 0.00E+ 00 4.51 E-01 1.52E-01 TOTAL FOR PERIOD CURIES 1.35E+02 1.36E+01 1.36E+02 2.08E+01
2. lODINES 1-131 CURIES 5.41 E-05 3.27E-05 1.3BE-04 2.33E-04 I

l-132 CURIES 0.00E+00 0.00E+00 0.00E+00 2.84E-07 l-133 CURIES 4.05E-06 2.00E-06 6.17E-06 0.00E+ 00 TOTAL FOR PERIOD CURIES 5.82E-05 3.47E-05 1.45E-04 '

2.33E-04 1

3. PARTICULATES CR-51 CURIES 0.00E+00 7.70E-07 4.05E-07 3.59E-07 i

CO-57 CURIES 2.20E-07 0.00E+00 0.00E+00 1.13E-10 CO-58 CURIES 0.00E+00 -

7.53E-06 0.00E+00 1.08E-05 i

CO-60 CURIES 0.00E+00 0.00E+00 0.00E+00 2.F.7E-07 BR82 CURIES 0.00E+0*

0.00E+00 2.95E-15 0.AE+00 J

NB-95 CURIES 0.00E+00 7.75E-07 0.00E+00 1.22E-07 BR-82 CURIES 0.00E+00 0.00E+00 2.95E-15 0.00E+ 00 G ALPHA CURIES 9.78E-07 6.06E-07 9.83E-07 6.77E-07 1

TOTAL FOR FERIOD CURIES 1.20E-06 9.68E-06 1.39E-06 1.22E-05

4. TRITIUM 1

H-3 CURIES 6.79E+ 00 7.47E+00 6.14E-01 9.52E+00 PAGE 1 OF 1

TABLE 5 DOSE AT THE SITE BOUNDARY AND TO THE NEAREST RESIDENT FROM GASEOUS EFFLUENTS SITE BOUNDARY NEAREST RESIDENT LOCATION:

2.05km N LOCATION:

2.83 km N AGE GROUP: CHILD AGE GROUP: CHILD l

ORGAN DOSE

% LIMIT (a)

DOSE

% LIMIT (b)

Gamma Air 5.40E-03 0.05 3.23E-03 N/A Dose (mrad)*

Beta Air 1.76E-02 0.09 1.05E-02 N/A Dose (mrad)*

i Whole Body (mRom)*

4.65E-03 N/A 2.79E-03 N/A Skin (mrem)*

1.34 E-02 N/A 8.02E-03 N/A Bone (mrem)*

  • 6.36E-06 N/A 2.40E-04 0.00 Liver (mrem)"

1.81 E-03 N/A 9.61 E-03 0.06 Total Body (mrem)"

1.81 E-03 N/A 9.61 E-03 0.06 Thyrcid (mrem)*

  • 2.00E-03 N/A 3.70E-02 0.25 Kidney (mrem)*
  • 1.81 E-03 N/A 9.66E-03 0.06 Lung (mrem)*
  • 1.81 E-03 N/A 9.52E-03 0.06 GI-LLI (mrem)*
  • 1.81 E-03 N/A 9.53E-03 0.06
  • Dose from Noble Gases only i

' Dose from Tritium, Radioiodines and Particulates only (a) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-01003) of 10 mrad gamma air dose and 20 mrad beta air dose.

(b) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-0107,3) of 15 mrem to any organ froin 1-131,1-133, H-3 and particulate radio-nuclides with halflives greater than 8 days.

Page 1 of 1

-~

TABLE 6 DOSE TO THE MEMBER OF THE PUBLIC FROM ACTMTIES WITHIN THE SITE BOUNDARY EFFLUENT DIRECT DIRECT l

DOSE WITHIN RADIATION RADIATION THE SITE FROM THE FROM OUTSIDE TOTAL DOSE BOUNDARY UNIT TANKS FOR THE YEAR ORGAN (mrem)

(mrem)

__(mrem /1100hr)_

(mRom)

Skin 2.51E-03 N/A N/A 2.51E-03 Bone 8.73E-04 9.00E-03 6.56E-04 1.05E-02 Liver 1.27E-03 9.00E-03 6.56E-04 1.09E-02 j

Total Body 1.27E-03 9.00E-03 6.56E-04 1.09E-02 Thyroid 1.30E-03 9 00E-03 6.56E-04 1.10E-02 Kidney 1.27E-03 9.00E-03 6.56E-04 1.09E-02 Lung 1.27E-03 9.00E-03 6.56E-04 1.09E-02 GI-LLI 1.27E-03 9.00E-03 6.56E-04 1.09E-02 l

l 1

i Page 1 of 1 1

J

e TABLE 7

~

l TOTAL DOSE DUE TO THE URANIUM FUEL CYCLE

-l (MEMBER OF THE PUBLIC)

DOSEFROM DOSE AT THE ACTIVITIES TOTAL DOSE RESIDENCE WITHIN THE TO THE MEMBER LOCATION SITE BOUNDARY OF THE PUBLIC

% LIMIT ORGAN (mrem)

(mrem)

(mrem) 40CFR190*

Skin 2.30E-03 2.51 E-03 4.81 E-03 0.02 Bone 8.30E-04 1.05E-02 1.14E-02 0.05 Liver 2.42E-03 1.09E-02 1.34E-02 0.05 Total Body 2.43E-03 1.09E-02 1.34E-02 0.05 Thyroid 4.82E-03 1.10E-02 1.58E-02 0.02 Kidney 2.43E-03 1.09E-02 1.34 E-02 0.05 Lung 2.41 E-03 1.09E-02 1.33E-02 0.05 GI-LLI 2.42E-03 1.09E-02 1.33E-02 0.05 l

1

  • Annual dose limits from 40CFR190.10(a) of 25 mrem whole body,75 mrem to the thyroid, and 25 mrem to any other organ.

Page 1 of 1

)

. -