ML20057D275

From kanterella
Jump to navigation Jump to search
Forwards Errata to First & Second Quarter 1992 Semiannual Radioactive Effluent Release Rept.Listed Corrective Actions Implemented to Prevent Recurrence of Apr 1992 Unusually High Activity Due to Use of Contaminated Marinelli
ML20057D275
Person / Time
Site: Callaway 
Issue date: 09/24/1993
From: Schnell D
UNION ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20057D277 List:
References
ULNRC-2856, NUDOCS 9310040062
Download: ML20057D275 (2)


Text

'#

GO! Ch

  • a A.m <

Ibt 0?!a & > 1 ]

Y t w !!:. o i M 314 554 hw Union ov ise.sco cri Etscruic v' - icu g

September 24, 1993 U.

S.

Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop P1-137 Washington, D.

C.

20555 Gentlemen:

ULNRC-2856 DOCKET NUMBER 50-483 CALLAWAY PLANT 1992 SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORTS ERRATA During June 1992 it was noted that several sequential noble gas samples collected during April showed an unusually high activity.

An investigation was initiated to evaluate the cause for this occurrence.

The subsequent investigation determined that the noble gas activity was due to the samples being collected in a marinelli that was contaminated by a waste gas decay tank sample.

The investigation was completed after the submittal dates for the 1992 Semiannual Radioactive Effluent Release Reports and the activity associated with the contaminated marinelli was included in these reports.

The following corrective actions were implemented to prevent recurrence of this event.

1)

Guidelines were developed for controlling contaminated marinellis.

2)

The computer software used for generating gaseous release permits was revised to incorporate a noble gas concentration-limit setpoint.

3)

The gaseous release permit checklist was revised to require verification of the sample concentration to the monitor trend prior to allowing the release.

4)

The Health Physics Technicians were trained on the incident and corrective actions taken to prevent recurrence.

010044 dh 9310040062 930924 5)

PDR ADDCM 05000483 ig R

PDR tu

September 24, 1993 ULNRC-2856 Page 2 i

The January - June 1992 Semiannual Radioactive Effluent Release Report. Tables 1A and 1B and the July - December 1992 Semiannual Radioactive Effluent Release Report Tables 5, 6,

and 7 have been updated to reflect the conclusions of our investigation.

These updated tables are attached to this letter.

If there are any questions relating to this information, please contact us.

Very truly yours, Donald F.

Schnell BFH/plh Attachments 1

l l

l 5

l 4

l 1

l

-