Text
i
1
'
i
!
n
,.
.
'
.
In Reply Refer To:
J1. 3 i M
Docket: STN 50-482/90-26
Wolf Creek Nuclear Operating Corporation
ATTN: Bart D. Withers
President and Chief Executive Of ficer
P.O. Box 411
Burlington. Kansas 66839
Gentlemen:
This refers to the inspection conducted by Messrs. M. E. Skow, W. B. Jones,
and D. V. Pickett and Ms. L. L. Gundrum of this office during the period
June 1-30, 1990. This inspection pertained to activities authorized by NRC
Operating License No. NPF-42 for the Wolf Creek Generating Station, and our
findings were discussed with Mr. J. A. Bailey and other members of your staff
at the conclusion of the inspection.
'
Areas examined during the inspection included plant status, operational safety
verification, monthly surveillance observation, monthly maintenance
observation, plant startup from refueling, onsite followup of events at
operating power reactors, and review of licensee event reports. Within these
areas, the inspection consisted of selective examination of procedures and
representative records, interviews with personnel, and observations by the NRC
inspectors. The inspection findings are documented in the enclosed inspection
report.
During this inspection, it was found that certain of your activities were in
violation of NRC requirements.
Consequently, you are required to respond to
these violations, in writing, in accordance with the provisions of
Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal
Regulations.
Your response should be based on the specifics contained in the
Notice of Violation enclosed with this letter.
One violation involves multiple examples of inadequate corrective actions
which have failed to prevent the recurrence of similar events.
The second violation concerns several examples of inadequate posttrip review
documentation. The individual examples were evaluated in the aggregate to be
of more than minor safety significance.
Additionally, during this inspection a violation pertaining to the failure to
!
update information into the Updated Safety Analysis Report (USAR) was
identified and evaluated. This violation is not being cited because the
,
criteria specified in Section V.A of the Enforcement Policy were satisfied, as
'
- RIV: SRI
- RI
- NRR
- DRP/D
- C:0RP/D
RP A
MESkow:sa
LLGundrum
DVPickett
WBJones
JSWiebe
p SJCollins
7/ /90
7/ /90
7/ /90
7/ /90
7/ /90 } 7/>l/90
- previously concurred
2008060293 90o73j
h'>n
aDOCK 03ogo4gp
lll
,
FDC
-
u
1
-,
d.
,
.
.
,
-
.
,
Wolf Creek Nuclear Operating
-2-
Corporation
enclosed inspection report. This action should not be considered to diminish
the licensee's responsibility to maintain the USAR current, to in part allow
for adequate 10 CFR 50.59 reviews.
'
We have also examined actions you have taken with regard to a previously
identified inspection finding.
The status of this item is identified in
paragraph 9 of the enclosed report.
The response directed by this letter and the accompanying Notice is not subject
to the clearance procedures of the Office of Management and Budget as required
by the Paperwork Reduction Act of 1980, PL 96-511.
Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
Sincerely.
Odo nat Skmed Dy:
n
Ttow. P. Gwynn
Samuel J. Collins, Director
Division of Reactor Projects
Enclosures:
Appendix A - Notice of Violation
!
Appendix B'- NRC Inspection Report
)
50-482/90-26
cc w/ enclosures:
Wolf Creek Nuclear Operating Corp.
ATTN: Gary Boyer, Plant Manager
P.O. Box 411
Burlington, Kansas 66839
Shaw, Pittman, Potts & Trowbridge
ATTN: Jay Silberg, Esq.
1800 M Street, NW
Washington, D.C.
20036
Public Service Comission
ATTN:
Chris R. Rogers, P.E.
Manager Electric Department
P.O. Box 360-
Jeffersoa City, Missouri 65102
U.S. Nuclear Regulatory Comission
ATTN:
Regional Administrator, Region III
799 Roosevelt Road
!
i
Glen Ellyn, Illinois 60137
l
!
t
.
,
.
-
.
..
l >
j
Wolf Creek Nuclear Operating
-3-
Corporation
Wolf Creek f:uclear Operating Corp.
ATTN: Otto Maynard, Manager
Regulatory Services
P.O. Box 411
.
,
Burlington, Kansas 66839
Kansas Corporation Connission
ATTN: Robert Elliot, Chief Engineer
Utilities Division
4th Floor - State Office Building
Topeka, Kansas 66612-1571
Office of the Governor
State of Kansas
Topeka, Kansas 66612
Attorney General
1st Floor - The Statehouse
Topeka, Kansas 66612
Chairman, Cof fey County Connission
Coffey County Courthouse
Burlington, Kansas 66839
Kansas Department of Health
and Environnent
Bureau of Air Quality & Radiation
Control
ATTN: Gerald Allen, Public
Health. Physicist
Divition of Environment
Forbes Field Building 321
Topeka. Kansas 66620
U.S. Nuclear Regulatory Connission
ATTN: -Senior Residei'it inspector
P.O. Box 311
Burlington, Kansas 66839
U.S. Nuclear Regulatory Connission
ATTN:
Regional Administrator. Region IV
611 Ryan Plaza Drive. Suite 1000
Arlington, Texas 76011
bectoDMB(IE01)
,
,
o.
.
..
.
.
.
Wolf Creek Nuclear Operating
-4-
,
Corporation
.
bec distrib. by RIV:
- R. D. Martin, RA
- SectionChief(DRP/D)
- RPB-DRSS
R. Hague, Rlll
- RIV File
SRI, Callaway, Rlll
- Project Engineer, DRP/D
- DRS
- Mis System
- RSTS Operator
- L. Shea , RM/ALF
- SRI Wolf Creek
- D. V. Pickett NRR Project Manager (MS:
13-D-18)
' *w/766
,