ML20054K015
| ML20054K015 | |
| Person / Time | |
|---|---|
| Site: | Bellefonte |
| Issue date: | 06/23/1982 |
| From: | Mills L TENNESSEE VALLEY AUTHORITY |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| REF-PT21-82 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8206300301 | |
| Download: ML20054K015 (2) | |
Text
_
e O
TENNESSEpA1. LEY AUTHORITY CH ATTANOOGA@ Street Tower II NNRSSEE 374ol 400 Chestnut N dl'f' 25 J ne 1982 A
BLRD-50-438/82-19 x
U.S. Nuclear Regulatory Commission Region II Attn:
Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303
Dear Mr. O'Reilly:
BELLEFONTE NUCLEAR PLANT UNIT 1 - DEFICIENT WELD 0LETS ON NAVC0 SPOOL PIECES
- BLRD-50-438/82 SECOND INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector R. V. Crlenjak on February 24, 1982 in accordance with 10 CFR 50.55(e) as NCR 1740. This was followed by our first interim report dated March 24, 1982. Enclosed is our second interim report. We expect to submit our next report by October 4, 1982.
We consider 10 CFR Part 21 applicable to this deficiency.
If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.
Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Licensing Enclosure cc:
Mr. Richard C. DeYoung, Director (Enclosure)
Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 d
p an 8206300301 820623 PDR ADOCK 05000430 S
PDR An Equal Opportunity Employer
I ENCLOSURE BELLEFONTE NUCLEAR PLANT UNIT 1 DEFICIENT WELD 0LETS ON NAVC0 SPOOL PIECES NCR 1740 - BLRD-50-43B/82-19 10 CFR 50.55(e)
SECOND INTERIM REPORT Description of Deficiency Five weldolets on spool pieces 1ND-196,1ND-198,1ND-200,1ND-202, and 1NV-242 exhibit welds that do not conform to the ASME Code Section III Subsection NB (for class 1 components) or Subsection NC (for class 2 components) requirements for fabrication. The welds are typically below flush 1/64 inch to 3/32 inch. In addition, a weld at the upper apex of a special thermowell boss on spool piece 1NV-241 was ground down below flush. The subject weldolets are installed in the Decay Heat Removal (ND) System and Makeup and Purification (NV) System piping.
The vendor of these items was National Valve and Manufacturing Company (NAVCO) of Pittsburgh, Pennsylvania.
Interim Progress TVA is investigating an apparent discrepancy between the weld requirements for the subject weldolets specified in the ASME Code and TVA's site inspection procedures outlined in General Construction Specification G-29C, " Process Specifications for Welding, Heat Treatment, Nondestructive Examination, and Allied Field Fabrication Operations." TVA will supply additional information on this deficiency upon completion of this investigation.
O e -,-
-r-i-. -
y-
-