TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION _

SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 1-SHP-HSS-27 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-28 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-29 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-30 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-31 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-32 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-33A 6"

Safeguards A

N D

ain Steam System 1-SHP-HSS-33B 6"

Safeguards A

N D

Main Steam System 1-SHP-ilSS-34A 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-34B 6"

Safeguards A

N D

hain Steam System 1-SHP-HSS-35A 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-35B 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-3C 1 1/2" Safeguards A

N R'

Main Steam System 1-SHP-HSS-37 1 1/2" Safeguards A

N R

,k Eo Main Steam System 1-SHP-HSS-38 1 1/2" Safeguards A

N R

gg SoO Main Steam. System 1-SHP-HSS-39 1 1/2" Safeguards A

N R

nm:s:

.of PSA-1 Safeguards A

N D

D4; Main Steam System (1-SHP-MSS-50 Main Steam System 1-SHP-MSS-51A PSA-35 Safeguards A

N D

j Nb SG.R.

A_

~

._m

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Main Steam System 1-SHP-MSS-SIB PSA-35 Safeguards A

N D

D Msin Steam System 1-SHP-MSS-52A PSA-35 Safeguards A

N

,\\

Main Steam System 1-SHP-MSS-52B PSA-35 Safeguards A

N D

Main Steam System 1-SHP-MSS-53A PSA-35 Safeguards A

N D

1 Main Steam System i-SHP-MSS-53B PSA-35 Safeguards A

N D

Main Steam System 1-SHP-MSS-54A PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-54B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-55A PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-55B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-56A PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-56B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-57 PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-58 PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-59A PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-59B PSA-3 Safeguards A

N D

Main Steam. System 1-SHP-MSS-60A PSA-3 Safeguards A

N D

Mair Steam System l1-SHP-MSS-60B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-61A PSA-3 Safeguards A

N D

9

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Main Steam System 1-SHP-MSS-61B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-ilSS-1A 5"

Machinery Room #1 A

N D

Main Steam System 1-SilP-HSS-1 B 5"

Machinery Room #1 A

N D

Main Steam System 1-SilP-HSS-14 A 5"

Machinery Room #1 A

N D

Main Steam System 1-S!!P-ilSS-14 B 5"

Machinery Room #1 A

N D

Main Steam System 1-SHP-HSS-21 4"

Machinery Room #1 A

N D

Main Steam System 1-SHP-HSS-22 4"

Machinery Room i1 A

N D

Main Steam System 1-SilP-HSS-23 4"

Machinery Room #1 A

N D

Main Steam System 1-SHP-liSS-24 4"

Machinery Room #1 A

N D

Main Steam System 1-SHP-liSS-25 4"

Machinery Room #1 A

N D

Main Steam System 1-SHP-HSS-26 4"

Machinery Room #1 A

N D

Main Steam System 1-SHP-HSS-2A 5"

Containment-67' level I

H D

Main Steam System 1-SHP-HSS-2B 5"

Containment-67' level I

H D

~

Main Steam System 1-SilP-HSS-3A 3 1/4" Containment-67' level I

H R

Main Steam System 1-SHP-HSS-3B 3 1/4" Containment-67' level I

H R

Main Steam System 1-SilP-HSS-4 A 3 1/4" Containment-67' level I

H R

Main Stean System 8l1-SHP-HSS-4B 3 1/4" Containment-67' level I

H R

Main Steau. System 1-SHP-HSS-5A 2 1/2" Containment-67' level I

H R

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 1-SHP-HSS-5B 2 1/2" Containment-67' level I

H R

Main Steam System 1-SIIP-ilSS-6A 2 1/2" Containment-67' level I

H R

Main Steam System 1-SHP-HSS-6B 2 1/2" Containment-67' leve I

H R

Main Steam System 1-SHP-USS-7 8"

Containment Operating level I H

D Main Steam System 1-SHP-HSS-8 8"

Containment Operating level I H

D Main Steam System 1-SHP-HSS-9 10" Containment Operating level I H

D Main Steam System 1-SHP-HSS-10 10" Containment Operating level I H

D Main Steam System 1-SHP-HSS-Il 8"

Containment Operating level I H

D Main Steam System 1-SHP-HSS-12 8"

Containment Operating level I H

D Main Steam System 1-SHP-HSS-13A 4"

Containment Operating level I H

D

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Feed System 1-WFPD-HSS-18 1 1/2" Safeguards A

N R

Main Feed System 1-WFPD-HSS-20 3 1/4" Safeguards A

N R

Main Feed System 1-WFPD-USS-21A 2 1/2" Safeguards A

N R

Main Feed System 1-WFPD-USS-21B 2 1/2" Safeguards A

N R

Main Feed System 1-WFPD-HSS-22 3 1/4" Safeguards A

N R

Main Feed System 1-WFPD-HSS-1 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-2 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-3 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-4 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-6 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-8 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-9 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-10 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-11 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-12 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-13 2 1/2" Containment Operating Level I

H R

Main Feed System f1-WFPD-HSS-14 2 1/2" Containment Operating Level I

H R

8 Main Feed System 1-WFPD-HSS-15 2 1/2" Containment Operating Level I

H R

+

El illl n

LR AO VG R

R OE MT EA RC N

OY IR TO AG H

H IE DT AA RC YTIL IB I

I I

S SE CCA l

l e

e v

v e

e L

L A

g g

T n

n A

i i

D t

t a

a R

r r

O e

e 1

S p

p S

O O

7 E

1 R

t t

P n

n 4

P e

e U

N m

m E.

S O

n n

I i

i I

B I

T a

a A

A t

t C

n n

T O

O o

o N

L C

C T

I NU 2

2 E

/ /

Z 1

1 I

S 2

2 6

7 1

1 N

O S

S I

S S

T H

H A

N D

D G

P P

I F

F S

W W

E D

1 1

l' m

m e

e t

t s

s y

y M

S S

E T

d d

S e

e Y

e e

S F

F n

n i

i O

a a

M M

ll IfI

,1 il\\l1f h

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Aux. Feed System 1-WAPD-HSS-140 1 1/2" Containment Operating Level I

H R

Aux. Feed System 1-WAPD-HSS-141A 1 }/2" Containment Operating Level I

H R

Aux. Feed System 1-WAPD-HSS-141B 1 1/2" Containment Operating Level I

H R

Aux. Feed System 1-WAPD-HSS-142 1 1/2" Containment Operating Level I

H R

Aux. Feed System 1-WAPD-IISS-143A 1 1/2" Containment Operating Level I

H R

Aux. Feed System 1-WAPD-HSS-143B 1 1/2" Containment Operating Level I

H R

A N

R Aux. Feed System 1-WAPD-HSS-145 1 1/2" Safeguards A

N R'

Aux. Feed System 1-WAPD-HSS-146 1 1/2" Safeguards A

N R

Aux. Feed System 1-WAPD-HSS-147 1 1/2" Safeguards A

N R

Aux. Feed System 1-WAPD-HSS-148 1 1/2" Safeguards A

N R

Aux. Feed System 1-WAPD-IISS-149 1 1/2" Safeguards

  1. l

TABLE 4.17-1 UNIT No. 1 SUPPRESSOR DATA RADIATION REMOVAL j

SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Component Cooling System 1-CC-HSS-60A 2 1/2" Aux. Basement A

N R-l R

l Component Cooling System 1-CC-HSS-65 2 1/2" Aux. Basement A

N

.\\

Component Cooling System 1-CC-HSS-330 2 1/2" Aux. Basement A

N R

Component Cooling System 1-CC-HSS-331 2 1/2" Aux. Basement A

N R

Component Cooling System 1-CC-HSS-332A 2 1/2" Aux. Basement A

N R

Component Cooling System 1-CC-HSS-332B 2 1/2" Aux. Basement A

N R

Component Cooling System 1-CC-HSS-340A 2 1/2" Aux. Basement A

N R

Component Cooling System 1-CC-HSS-340B 2 1/2" Aux. Basement A

N R

Component Cooling System 1-CC-HSS-341 2 1/2" Aux. Basement A

N R

l 4

I f

l I

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY Lo-head Safety Injection 1-SI-HSS-19A 5"

Containment basement-I H

D A Accumulator Lo-head Safety Injection 1-SI-HSS-19B 5"

Containment basement-I H

D A Accumulator Lo-head Safety Injection 1-SI-HSS-20 8"

Containment basement-I H

D A Accumulator Lo-head Safety Injection 1-SI-HSS-22A 5"

Containment basement-I H

D B Accumulator Lo-head Safety Injection 1-SI-HSS-22B 5"

Containment basement-I H

D B Accumulator Lo-head Safety Injection 1-SI-HSS-23 8"

Containment basement-I H

D B Accumulator Lo-head Safety Injection 1-SI-ilSS-25 8"

Containment basement-I H

D C Accumulator Lo-head Safety Injection 1-SI-llSS-26 8"

Containment basement-I H

D C Accumulator Lo-head Safety Injection 1-SI-HSS-84 1 1/2" Safeguards basement A

N R

Lo-head Safety Injection 1-SI-HSS-85 1 1/2" Safeguards basement A

N R

Lo-head Safety Injection 1-SI-HSS-100 1 1/2" Safeguards Valve Pit A

N R

Lo-head Safety Injection 1-SI-HSS-101 1 1/2" Safeguards Valve Pit A

N R

Lo-head Safety Injectiep 1-SI-HSS-21A 4"

Containment basement I

H D

Lo-head Scfety Injection 1-SI-HSS-21B 4"

Containment basement I

H D

O

l TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATIO.1 REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Lo-head Safety Injection 1-SI-HSS-24A 4"

Containment Basement I

H D

Lo-head Safety Injection 1-SI-HSS-24B 4"

Containaent Basement I

H D

Lo-head Safety Injection 1-SI-HSS-27A 4"

Containment Basement I

H D

Lo-head Safety Injection 1-SI-HSS-27B 4"

Containment Basement I

H D

Lo-head Safety Injection 1-SI-HSS-28 1 1/2" Containment Basement I

H R

l l

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY Recir. Spray System 1-RS-HSS-107 3 1/4" Safeguards Valve Pit A

N R

1-RS-HSS-106 1 1/2" Containment 90' elevation I H

D Recir. Spray System Recir. Spray System 1-RS-HSS-105 1 1/2" Containment 3' level I

H R

Recir. Spray System 1-RS-MSS-115A PSA-3 Containment 10' level I

H D

Recirc. Spray System 1-RS-MSS-115B PSA-3 Containment 10' level I

H D

Recire. Spray System 1-RS-MSS-116A PSA-3 Containment 10' level I

H D

Recire. Spray System 1-RS-MSS-116B PSA-3 Containment 10' level I

H D

6

  • l

l TABLE 4.17-1 f

UNIT NO. 1 SUPPRESSOR DATA J

i RADIATION REMOVAL ^

SYSTEM DESIGNATION SIZE LOCATION.

ACCESSIBILITY

'CATECORY.

CATECORY l

1-CH-HSS-301 1 1/2" Aux. Building A

N.

R Chemical Volume &

Control System Chemical Volume &

1-CH-HSS-302 1 1/2" Aux. Building A

N' R

Control System j

1 t

l I

'l O

~

m

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Reactor Coolant System 1-RC-HSS-110 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-Ill 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-Il2 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-113 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-114 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-Il5 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-IISS-122 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-HSS-123 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-HSS-124 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-HSS-125 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-HSS-138 12" A S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-139 12" A S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-140 12" A S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-141 12" A S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-142 12" B S/C Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-143 12" B S/G Upper restraint I

H D

casting R,eactor Coolant Systemij 1-RC-HSS-144 12" B S/G Upper restraint I

H D

casting Reactor Cool;.at System 1-RC-HSS-145 12" B S/G Upper restraint I

H D

casting

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL i

SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY Reactor Coolant System 1-RC-HSS-146 12" C S/G Upper restraint I

H D

1 canting D

l Reactor Coolant System 1-RC-HSS-147 12" C S/C Upper restraint I

H

.I casting Reactor Coolant System 1-RC-HSS-148 12" C S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-149 12" C S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-172 4 1/2" A S/G I

H D

Reactor Coolant System 1-RC-IISS-173 4 1/2" A S/G I

H D

Reactor Coolant System 1-RC-HSS-174 4 1/2" A S/G I

H D

Reactor Coolant System 1-RC-HSS-175 4 1/2" A S/G I

H D

Reactor Coolant System 1-RC-HSS-176 4 1/2" B S/G I

H D

Reactor Coolant System 1-RC-HSS-177 4 1/2" B S/G I

H D

Reactor Coolant System 1-RC-HSS-178 4 1/2" B S/G I

H D

Reactor Coolant System 1-RC-HSS-179 4 1/2" B S/G I

H D

i Reactor Coolant System 1-RC-HSS-180 4 1/2" C S/G I

H D

Reactor Coolant System 1-RC-HSS-181 4 1/2" C S/G I

H D

Reactor Coolant System 1-RC-HSS-182 4 1/2" C S/G I

H D

Reactor Coolant System 1-RC-HSS-183 4 1/2" C S/G I

H D

Reactor Coolant Systenif 1-RC-MSS-Il5A PSA-10 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-115B PSA-10 Pressurizer Cubicle I

H D

' Reactor Coolant System 1-RC-MSS-116A PSA-10 Pressurizer Cubicle I

H D

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATEGORY Reactor Coolant System 1-RC-MSS-Il6B PSA-10 Pressurizer Cubicle I

H D

D Reactor Coolant System 1-RC-MSS-Il7A PSA-10 Pressurizer Cubicle I

H

,i Reactor Coolant System 1-RC-MSS-Il7B PSA-10 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-218 PSA-1 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-219 PSA-1/2 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-220 PSA-1/2 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-221 PSA-3 Outside Pressurizer I

H D

Cubicle Reactor Coolant System 1-RC-MSS-222 PSA-3 Outside B S/G Cubicle I

H D

Reactor Coolant System 1-RC-MSS-126 PSA-4" A RCP I

H D

Reactor Coolant System 1-RC-MSS-127 4"

A RCP I

H D

Reactor Coolant System 1-RC-MSS-128 4"

A RCP I

H D

Reactor Coolant System 1-RC-MSS-129 4"

A RCP I

H D

Reactor Coolant System 1-RC-MSS-130 4"

B RCP I

H D

Reactor Coolant System 1-RC-MSS-131 4"

B RCP I

H D

Reactor Coolant System 1-RC-MSS-132 4"

B RCP I

H D

Reactor Coolant System 1-RC-MSS-133 4"

B RCP I

H D

Reactor Coolant Systedl l-RC-MSS-134 4"

C RCP I

H D-

~.

I D

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY C?u'EGORY Reactor Coolant System 1-RC-MSS-135 4"

C RCP I

H D

Reactor Coolant System 1-RC-MSS-136 4"

C RCP I

H D

Reactor Coolant System 1-RC-MSS-137 4"

C RCP I

H D

Reactor Coolant System 1-RC-HSS-150 12" A S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-151 12" A S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-152 12" A S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-USS-153 12" A S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-154 12" B S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-155 12" B S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-156 12" B S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-157 12" B S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-158 12" C S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-159 12" C S/C Lower Support ring I

H D

i Reactor Coolant System 1-RC-HSS-160 12" C S/G Lower Support ring I

H D

Reictor Caolant System 1-RC-HSS-161 12" C S/G Lower Support ring I

H D'

Reactor Caolant Systes.

1-RC-HSS-162 12" A RCP Lower Support ring I

H D

Re actor Caolant Syste j 1-RC-HSS-163 12" A RCP Lower Support ring I

H D

~.

Rt i: tor (oolant Syste I-RC-HSS-166 12" B RCP Lower Support ring I

H D

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY

'CATECORY Reactor Coolant System 1-RC-HSS-167 12" B RCP Lower Support beam I

H D

Reactor Coolant System 1-RC-HSS-170 12" C RCP Lower Support beam I

H D

Reactor Coolant System 1-RC-IISS-171 12" C RCP Lower Support beam I

H D

4 Reactor Coolant System 1-PS-MSS-1A PSA 1 A S/G elevation 55' I

H D

Reactor Coolant System 1-PS-MSS-2A PSA-1/4 A S/G elevation 55' I

H D

Reactor Coolant System 1-PS-MSS-1B PSA-1 B S/G elevation 55' I

H D

Reactor Coolant System 1-PS-MSS-2B PSA-1/4 B S/G elevation 55' I

H D

Reactor Coolant System 1-PS-MSS-1C PSA-1 C S/G elevation 55' I

H D

Reactor Coolant System 1-PS-MSS-2C PSA=l/4 C S/G elevation 55' I

H D

Reactor Coolant Syster 1-RC-HSS-164 1 1/2" A Loop room-Elevation 20' I

H R

Reactor Coolant System 1-RC-HSS-165 1 1/2" A Loop room-Elevation 20' I

H R

Reactor Coolant System 1-RC-HSS-168 1 1/2" B Loop room-Elevation 20' I

H R

Reactor Coolant System 1-RC-HSS-169 1 1/2" B Loop room-Elevation 20' I

H R

Reactor Coolant System 1-RC-HSS-ll6 1 1/2" C Loop room-Elevation 20' I

H R

Reactor Coolant System 1-RC-HSS-117 1 1/2" ^ C Loop room-Elevation 20' I

H R

I H

D Reactor Coolant System 1-PS-MSS-IIA PSA-10 A Loop room ReactorCoolantSystemj 1-PS-MSS-23B PSA-1/4 B Loop room-Elevation 12' I

H D

Reactor Coolant System 1-PS-MSS-10C PSA-1/4 C Loop room Elevation 12' I

H D

1

i TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATEGORY Reactor Coolant System 1-PS-MSS-12C PSA-1/4 C Loop room El-13' I

H D

Reactor Coolant System 1-PS-MSS-14C PSA-1/4 C Loop room El-13' I

H D

Reactor Coolant System 1-RC-HSS-102 1 1/2" Containment Basement I

H R

Reactor Coolant System 1-RC-HSS-103 1 1/2" Containment Basement I

H R

Reactor Coolant System 1-RC-HSS-104 1 1/2" Containment Basement I

H R

Reactor Coolant System 1-7.C-HSS-105 1 1/2" Containment Basement' I

H R

Reactor Coolant System 1-RC-HSS-106 1 1/2" Containment Basement I

H R

Reactor Coolant System 1-RC-HSS-107 1 1/2" Containment Basement I

H R

Reactor Coolant System 1-RC-HSS-108 1 1/2" Containment Basement-I H

R i

'l

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY 1-WCMU-HSS-100 1 1/2" Safeguards A

N R

Make-up System Containment Spray System 1-CS-IISS-01 1 1/2" Safeguards Basement A

N R

Service Water System 1-SW-HSS-2 PSA-1/4 Machinery Room #3 A

N D

Emergency Diesel 1-EE-IISS-01 1 1/2"

  1. 1 EDC Exhaust A

N R

Emergency Diesel 1-EE-IISS-03 1 1/2"

  1. 3 EDG Exhaust A

N R

S/G Blowdown 1-WGCB-IISS-10 1 1/2" Aux. Basement A

N R

S/G Blowdown 1-WGCB-MS$-23 PSA-3 Aux. Basement A

N D

S/G Blowdown 1-WGCB-MSS-Il PSA-1/2 A Loop room-El. 13/6" 1

H D

S/G Blowdown 1-WGCB-MSS-12 PSA-1/2 A loop room-El. 7'8" I

H D-S/G Blowdown 1-WGCB-MSS-13 PSA-1/2 A loop room-El. 8'3" I

H D

S/G Blowdown 1-WCCB-MSS-14A PSA-1/2 A loop room-El. 6' I

H D

S/G Blowdown 1-WGCB-MSS-14B PSA-1/2 A loop room-El. 6' I

H D

S/G Blowdown 1-WGCB-MSS-15A PSA-1/2 A S/G Cubicle I

H D

S/G Blowdown 1-WGCB-MSS-15B PSA-1/2 A S/C Cubicle I

H D

S/G Blowdown 1-WCCB-MSS-16 PSA-1/2 A S/G Cubicle I

H D

S/G Blowdown 1-WCCB-MSS-17A PSA-1/2 B loop room-El. 13' I

H D

S/G Blowdown 8l l-WGCB-MSS-17B PSA-1/2 B loop room-El. 13' I

H D

j S/G Blowdown 1-WGCB-MSS-18A PSA-1/2 B loop room-El. 7' I

H D

$/G Blowdown 1-WGCB-MSS-18B PSA-1/2 B loop room-El. 7' I

H D

TABLE 4.17-1 UNIT NO. I SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY S/G Blowdown 1-WCCB-MSS-19 PSA-1/2 B loop room-El. 10' I

H D

S/C Blowdown 1-WCCB-MSS-100 PSA-1/2 B loop room-El. 15' I

H D

t S/G Blowdown 1-WCCB-MSS-10 PSA-1/2 C loop room-El. 12' I

H D

S/C Blowdoun 1-WCCB-MSS-20A PSA-1/2 C loop room El. 6' I

H D

S/G Blowdown 1-WCCB-MSS-20B PSA-1/2 C loop room-El. 6' I

H D

S/G Blowdown 1-WCCB-MSS-21 PSA-1/2 C loop room-El. 12' I

H D

I H

R S/G Blowdown 1-WCCB-HSS-02 2 1/2 C loop room S/G Blowdown 1-WCCB-HSS-03 2 1/2 C loop room I

H R

i 4

G

TABLE 4.17-1 UNIT NO. I SUDPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Residual Heat Removal Sys.

1-RH-HSS-103 2 1/2" A loop room-El. 3' I

H R

Residual Heat Removal Sys.

1-RH-HSS-104 2 1/2" A loop room-El. 3' I

H R

Residual Heat Removal Sys.

1-RH-MSS-120A PSA-3 A loop room I

H D

Residual Heat Removal Sys.

1-RH-MSS-120B PSA-3 A loop room I

H D

Residual Heat Removal Sys.

1-RH-HSS-1 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-2 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-3 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-4 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-5 2 1/2" RHR Flat I

H R

kasidual Heat Removal Sys.

1-RH-HSS-6 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-7 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-8 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-9 1 1/2" RHR Flat I

H R.

Residual Heat Removal Sys.

1-RH-HSS-10 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-Ril-HSS-I l 1 1/2" RHR Flat I

H R

Residual IIcat Removal Sys.

1-RH-HSS-12 1 1/2" RHR Flat I

H R

Residual lleat Removal yys.

1-RH-HSS-13 1 1/2" RHR Flat I

H R

Residual lleat Removal Sys.

1-RH-HSS-14 1 1/2" RHR Flat I

H R

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Residual Heat Removal Sys.

1-RH-HSS-15 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-19 1 1/2" RilR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-20 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-105 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RII-HSS-21 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-IISS-22 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-Ril-HSS-23 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-24 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-25 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-Ril-IISS-100 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-101A 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-101B 1 1/2" RHR Flat I

H R

I Residual Heat Removal Sys.

1-RH-HSS-102 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-26 1 1/2" RHR Flat I

H R

i Rcsidual lleat Removal Sys.

1-RH-IISS-27 1 1/2" RHR Flat I

H R

Residual lleat Renoval Sys.

1-RH-IISS-28 1 1/2" RHR Flat I

H R

l

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY Main Steam System 2-SHP-HSS-1A 5"

Safeguards A

N D

Main Steam System 2-SHP-HSS-1B 5"

Safeguards A

N D

Main Steam System 2-SHP-HSS-14A 5"

Safeguards A

N D

Main Steam System 2-SHP-HSS-14B 5"

Safeguards A

N D

Main Steam System 2-SHP-ilSS-15 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-16 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-17 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-18 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-19 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-20 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-21 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-22 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-23 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-24 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-25 4"

Safeguards A

N D

4

Safeguards A

N D

Main Steam System

/2-SHP-HSS-26 Main Steam System 2-SHP-HSS-27 6"

Safeguards A

N D

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Main Steam System 2-SHP-HSS-28 6"

Safeguards A

N D

i Main Steam System 2-SUP-HSS-29 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-30 6"

Safeguards A

N D

i Main Steam System 2-SHP-HSS-31 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-32 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-33A 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-34A 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-35A 6"

Safeguards A

N D

i D

Main Steam System 2-SHP-HSS-35B 6"

Safeguards A

N

'~-

3

_,Q'

'%in Steam System 2-SHP-HSS-36A 1 1/2" Safeguards A

'N y Nf R

-c 1

Main Steam System 2-SHP-HSS-36B 1 1/2" Safeguards A,

N R

3 3.;

gs eg

'2' R-Main Steam System 2-SHP-HSS-40 2 1/2" Safeguards

/

A

  • ~N

~

s Main Steam System 2-SHP-HSS-41 2 1/2" Safeguards

") ' A N

R t

Main Steam System 2-SHP-HSS-42 2 1/2" Safeguards A

N R

Main Steam System 2-SHP-HSS-51 1 1/2" Safeguards A

N R

Main Sterm System 2-SHP-MSS-1 PSA-3 Safeguards A

N D

PSA-3 Safeguards A

,M D

Main Sterm System sg 2-SHP-MSS-2 bbin Stet.m System 2-SHP-MSS-3 PSA-3 Safeguards A

N y7 N D-s

+tain Steam System 2-SHP-MSS-4 PSA-3 Safeguards A

N D

s

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESICNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY A

N D

Main Steam System 2-SHP-MSS-5 PSA-3 Safeguards A

N D

Main Steam System 2-SHP-MSS-6 PSA-4 Safeguards Main Steam System 2-SilP-HSS-2A 5"

Containment 67' leve I

H D

Main Steam System.

2-SHP-HSS-2D 5"

Containment 67' level I

H 3D Main Steam System 2-SHP-HSS-3A 3 1/2" Containment 55' level I

H R

Main Steam System 2-SHP-HSS-3B 3 1/2" Containment 55' level I

H R

Main Steam System 2-SHP-HSS-4A 3 1/2" Containment 55' level I

H R

Main Steam System 2-SHP-HSS-4B 3 1/2" Containment 55' level I

H R

Main Steam System 2-SHP-HSS-SA 2 1/2" Containment Operating level I H

R Main Steam System 2-SHP-HSS-5B 2 1/2" Containment Operating level I H

R Main Steam System 2-SHP-HSS-6A 2 1/2" Containment Operating level I H

R Main Steam System 2-SilP-HSS-6B 2 1/2" Containment Operating level I H

R Main Steam System 2-SHP-HSS-7 6"

Containment Operating level I H

D Main Steam System 2-SHP-HSS-8 6"

Containment Operating level I H

D Main Steam System 3HP-HSS-9 10" Containment Operating level I H

D Main Steam System 2-SHP-HSS-10 10" Containment Operating level I H

D 8"

Containment Operating level I H

D Main Steam System 8l2-SHP-HSS-11 Main Steam System 2-SHP-HSS-12 8"

Containment Operating level I H

D

' Main Steam System 2-SHP-HSS-13A 4"

Containment Operating level I H

D w.

TABLE 4.17-2 e

UNIT NO. 2 SUPPRESSOR DATA RADIATION RE%0 VAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATEGORY Main Feed System 2-WFPF-HSS-14 2 1/2" Safeguards A

N R

Main Feed System 2-WFPD-HSS-15 3 1/4" Safeguards A

N R

i Main Feed System 2-WFPD-HSS-16 3 1/4" Safeguards A

N R

Main Feed System 2-WFPD-HSS-17 3 1/4" Safeguards A

N R

Main Feed System 2-WFPD-HSS-1 2 1/2" Containment Operating Level I H

R Main Feed System 2-WFPD-HSS-2 2 1/2" Contrinment Operating Level I H

R Main Feed System 2-WFPD-HSS-3 2 1/2" Containment Operating Level I H

R Main Feed System 2-WFPD-HSS-4 2 1/2" Containment Operating Level I H

R Main Feed System 2-WFPD-HSS-5 2 1/2" Containment Operating Level I H

R Main Feed System 2-WFPD-HSS-6 2 1/2" Containment Operating Level I H

R Main Fee.i System 2-WFPD-HSS-7 4"

Containment Operating Level I H

D Main Feed System 2-WFPD-HSS-8 4"

Containment Operating Level I H

D Main Feed System 2-WFPD-HSS-9 4"

Containment Operating Level I H

D Main Feed System 2-WFPD-HSS-10 4"

Containment Operating Level I H

D Main Feed System 2-WFPD-HSS-11 2 1/2" Containment Operating Level I H

R Main Feed Systen 2-WFPD-HSS-12 2 1/2" Containment Operating Level I H

R 2 1/2" Containment Operating Level I H

R Main Feed System sg 2-WFPD-HSS-13 G

f TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL j

SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Aux. Feed System 2-WAPD-HSS-140 1 1/2" Containment Operating Level I H

R Aux. Feed System 2-WAPD-HSS-141 1 1/2" Containment Operating Level I H

R

\\

Aux. Feed System 2-WAPD-HSS-142 1 1/2" Containment Operating Level I H

R Aux. Feed System 2-WAPD-HSS-143 1 1/2" Containment Operating Level I H

R Aux. Feed System 2-WAPD-HSS-18 2 1/2" Safeguards A

N R

Aux. Feed System 2-WAPD-HSS-144 1 1/2" Safeguards A

N R

Aux. Feed System 2-WAPD-HSS-145A 1 1/2" Safeguards A

N R

Aux. Feed System 2-WAPD-HSS-145B 1 1/2" Safeguards A

N R

1 e

'l

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA P

RADIATION REMOVAL SYSTEM DESICNATION SIZE LOCATION ACCESSIBILITY _

CATEGORY CATECORY Component Cooling System 2-CC-HSS-356A 2 1/2" Aux. Basement A

N

-R Component Cooling System 2-CC-HSS-356B 2 1/2" Aux. Basement A

N R

Component Cooling System 2-CC-HSS-357 1 1/2" RHR Flat I

H R

i, Component Cooling System 2-CC-HSS-358 1 1/2" RelR Flat I

H R

l Component Cooling System 2-CC-HSS-359 1 1/2" RHR Flat I

H R

e

'I O

l TABLE 4.I7-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL l

SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY l

Recire. Spray System 2-RS-HSS-101 1 1/2" Containment Basement I

H R

Recire. Spray System 2-RS-HSS-102 1 1/2" Containment Basement I

H R

I Recire. Spray System 2-RS-HSS-103 1 1/2" Containment Basement I

H R

Recire. Spray System 2-RS-HSS-104 1 1/2" Containment Basement I

H R

1 4

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY S/G Blowdown System 2-WGCB-HSS-4A 1 1/2" Aux. Building A

N R

S/G Blowdown System 2-WGCB-HSS-4B 1 1/2" Aux. Building A

N R

S/G Blowdown System 2-WGCB-HSS-7A 1 1/2" Aux. Building A

N R

S/G Blowdown System 2-WGCB-HSS-7B 1 1/2" Aux. Building A

N R

S/G Blowdown System 2-WGCB-IISS-8A 1 1/2" Aux. Building A

N R

S/C Blowdown System 2-WCCB-HSS-8B 1 1/2" Aux. Building A

N R

S/G Blowdown System 2-WGCB-HSS-01 1 1/2" Containment 3rd level I

H R

S/G Blowdown System 2-WGCB-HSS-02 2 1/2" B loop room I

H R

S/C Blowdown System 2-WGCB-HSS-03 2 1/2" C loop room I

H R

S/G Blowdown System 2-WCCB-HSS-5 1 1/2" A Cubicle I

H R

S/G Blowdown System 2-WGCB-HSS-6A 1 1/2" A Cubicle I

H R

S/G Blowdown System 2-WGCB-HSS-6B 1 1/2" A Cubicle I

H R

i 4

~

TABLE 4.17-2 UNIT No. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Charging System 2-CH-HSS-303 1 1/2" Aux. Building A

N R

Charging System 2-CH-HSS-304 1 1/2" Aux. Building A

N R'

Charging System 2-CH-HSS-305 1 1/2" Containment Basement I

H R

Charging System 2-CH-HSS-306A 1 1/2" Containment Basement I

H R

Charging System 2-CH-HSS-306B 1 1/2" Containment Basement I

H R

Charging System 2-CH-HSS-307 1 1/2" RHR Flat I

H R

Charging System 2-CH-MSS-1 PSA-3 Containment Baseatn I

H D

l Charging System 2-CH-MSS-2 PSA-3 Containment Basentn I

H D

Emergency Diesel 2-EE-HSS-02 1 1/2"

  1. 2 EDG Exhaust A

N R

Service Water System 2-SW-MSS-1 PSA-3 Containment Basement I

H D

i 4

i 1

  • I O

T 1

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA i

RADIATION REMOVAL l

l SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Containment Spray System 2-CS-HSS-01A 2 1/2" Safeguards Valve Pit A

N R

j Containment Spray System 2-CS-HSS-OlB 2 1/2" Safeguards Valve Pit A

N

.R

\\

3 1

'1 8

I I

i

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY Safety Injection System 2-SI-HSS-100 2 1/2" Safeguard-Valve Pit A

N R

Safety Injection System 2-SI-HSS-101 2 1/2" Safeguard-Valve Pit A

N R

\\

Safety Injection System 2-SI-HSS-103 1 1/2" Safeguard-Valve Pit A

N R

Safety Injection System 2-SI-HSS-104 A 2 1/2" Safeguard-Valve Pit A

N R

Safety Injection System 2-SI-HSS-104B 2 1/2" Safeguard-Valve Pit A

N R

Safety Injection System 2-SI-HSS-19A 5"

C Accumulator I

H D

Safety Injection System 2-SI-HSS-19B 5"

C Accumulator I

H D

Safety Injection System 2-SI-HSS-20 8"

C Accumulator I

H D

Safety Injection System 2-SI-HSS-21 6"

C Accumulator I

H D

Safety Injection System 2-SI-HSS -22A 5"

B Accumulator I

H D

Safety Injection System 2-SI-HSS-22B 5"

B Accumulator I

H D

Safety Injection System 2-SI-HSS-23 8"

B Accumulator I

H D

Safety Injection System 2-SI-HSS-25 8"

A Accumulator I

H D

Safety Injection System 2-SI-HSS-26 8"

A Accumulator I

H D

Safety Injection System 2-SI-HSS-24 6"

Containment Basement I

H D

Safety Injection System 2-SI-HSS-27 6"

Containment Basement I

H D

'l 9

T TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY Reactor Coolant System 2-RC-HSS-100 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-101 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-102 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-103 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-104 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-KC-HSS-105 1 1/2" Cont ainment Basement I

H R

Reactor Coolant System 2-RC-HSS-106 1 1/2 Pressurizer Relief Tank I

H R

Room Reactor Coolant System 2-RC-HSS-107 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-108 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-Il0 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-ll2 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-113 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-114 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-Il5 1 1/2" Pressurizer Cubicle I

H R

Rsactor foolant Systen 2-RC-HSS-116 1 1/2" Pressurizer Cubicle I

H R

R(actor (oolant Syste1 2-RC-IISS-Il7 1 1/2" Pressurizer Cubicle I

H R

Re actor ( oolant Syste y 2-RC-HSS-118 1 1/2" Pressurizer Cubicle I

H R

Fiactor 1001 ant Systs i 2-RC-HSS-119 1 1/2" Pressurizer Cubicle I

H R

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATEGORY Reactor Coolant System 2-RC-HSS-122 6"

Pressurizer Upper Support I H

D Reactor Coolant System 2-RC-HSS-123 6"

Pressurizer Upper Support I H

D Reactor Coolant System 2-RC-HSS-124 6"

Pressurizer Upper Support I H

D Reactor Coolant System 2-RC-HSS-125 6"

Pressurizer Upper Support I H

D Reactor Coolant System 2-RC-HSS-126 4"

A RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-127 4"

A RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-128 4"

A RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-129 4"

A RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-130 4"

B RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-131 4"

B RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-132 4"

B RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-USS-133 4"

B RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-134 4"

C RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-135 4"

C RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-136 4"

C RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-137 4"

C RCP Upper Holding I

H D

Assembly ReactorCoolantSystemj 2-RC-HSS-138 12" A S/G Upper restraint I

H D

Casti--

Reactor Coolant System' 2-RC-HSS-139 12" A S/G dpper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-140 12" A S/G Upper restraint I

H D

Casting

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION 2EMOVAL SYSTEM DESIGNATION SIZE LOCATION ACC'/.SSIBILITY CATEGORY CATEGORY Reactor Coolant System 2-RC-HSS-141 12" A S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-142 12" B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-143 12" B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-IISS-144 12" B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-145 12" B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-146 12" C S/G Upper Restraint I

H D

Casting Reactor Coolant System 2-RC-IISS-147 12" C S/G Upper Restraint I

H D

Casting Reactor Coolant System 2-RC-IISS-148 12" C S/G Upper Restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-149 12" C S/G Upper Restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-150 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-liSS-151 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-152 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-IISS-153 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-IISS-154 12" B S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-155 12" B S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-IISS-156 12" B S/G Lower Support Ring I

H D

Reactor Coolant Systehl 2-RC-IISS-157 12" B S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-158 12" C S/G Lower Support Ring I

H D

^ Reactor Coolant System 2-RC-IISS-159 12" C S/G Lower Support Ring I

H D

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System 2-RC-HSS-160 12" C S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-161 12" C S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-162 12" A RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-163 12" A RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-166 12" B RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-167 12" B RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-170 12" C RCP Lower Support Beam I

H-D Reactor Coolant System 2-RC-HSS-171 12" C RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-172 4 1/2" A S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-173 4 1/2" A S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-174 4 1/2" A S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-175 4 1/2" A S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-176 4 1/2" B S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-177 4 1/2" B S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-178 4 1/2" B S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-179 4 1/2" B S/G Upper Support I

H D

2-RC-HSS-180 4 1/2" C S/G Upper Support I

H D

ReactorCoolantSystemg Reactor Coolant System 2-RC-HSS-181 4 1/2" C S/G Upper Support I

H D

R'eactor Coolant System 2-RC-HSS-182 4 1/2" C S/G Upper Support I

H D

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATECORY Reactor Coolant System 2-RC-HSS-183 4 1/2" C S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-184 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-185 2 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-186 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-187 1 1/2" Pressurizer relief tank I

H R

room Reactor Coolant System 2-RC-HSS-188A 2 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-188B 2 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-189A 4"

Pressurizer Cubicle I

H D

Reactor Coolant System 2-RC-HSS-189B 4"

Pressurizer Cubicle I

H D

Reactor Coolant System 2-RC-HSS-190 1 1/2" C Loop Room I

H R

Reactor Coolant System 2-RC-MSS-1A PSA-1 A S/G Cubicle I

H D

Reactor Coolant System 2-RC-MSS-2A PSA-1/4 A S/G Cubicle I

H D

Reactor Coolant System 2-RC-MSS-14A PSA-1/4 A S/G Cubicle I

H D

l Reactor Coolant System 2-RC-MSS-1B PSA-1 B S/G Cubicle I

H D

Reactor Coolant System 2-RC-MSS-2B PSA-1/4 B S/G Cubicle I

H D

Reactor. Coolant System 2-RC-MSS-15B PSA-1/4 B S/G Cubicle I

H D

Reactor Coolant Systdq 2-RC-MSS-16B PSA-1/4 Containment 3rd level I

H D

Reactor Coolant System 2-RC-MSS-lC PSA-1 C S/G Cubicle I

H D

4 9

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESICNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Reactor Coolant System 2-RC-MSS-2C PSA-1 C 5/G Cubicle I

H D

D Reactor Coolant System 2-RC-MSS-15C PSA-1/4 C S/G Cubicle I

H l

Reactor Coolant System 2-RC-MSS-1 PSA-3 Containment 2nd level I

H D

Reactor Coolant System 2-RC-MSS-2 PSA-3 containment 2r.d level I

H D

Reactor Coolant System 2-RC-MSS-3 PSA-1/2 A Loop Room I

H D

I Reactor Coolant System 2-RC-MSS-4 PSA-1/2 B Loop Room I

H D

Reactor Coolant System 2-RC-MSS-5 PSA-1 Containment Operating I

H D

level Reactor Coolant System 2-RC-MSS-6 PSA-1 Containment Operating I

H D

level Reactor Coolant System 2-RC-MSS-7 PSA-1 Containment Operating I

H D

I level l

i

'I 9

u

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATECORY CATECORY Residual Heat Removal Sys.

2-RH-HSS-1 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-2 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-3 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-4 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-5 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-6 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-7 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-8 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-9 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-10 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-11 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-12 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-13 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-14 1 1/2" RHR Flat I

H R

Rv;idual lleat Removal Sys.

2-RH-HSS-15 1 1/2" RHR Flat I

H R

lirsidual lleat Remova: Sys.

2-RH-HSS-17 2 1/2" RHR Flat I

H R

Residual Iteat Remov2 ys.

2-RH-HSS-18 2 1/2" RHR Flat I

H R

L iidual l' eat Remov i Sys.

2-RH-HSS-19 2 1/2" RHR Flat I

H R'

Y LR VG R

R R

R R

R R

R R

R R

R R

R R

R R

R R

AO OE MT EA RC NOY I R AG H

H H

H H

H H

H H

H H

H H

H H

H H

H H

TO IE DT AA RC YT IL I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

B t

t t

t t

t t

S E

n n

n n

n n

n S

A C

e e

e e

e e

e T

C m

m m

m m

m m

A A

e e

e e

e e

e s

s s

s s

s s

a a

a a

a a

a D

B B

B B

B B

B R

t t

m t

t t

t t

O n

n o

n n

n n

n 2

S e

e o

e e

e e

e S

1 R

N t

t t

t t

t m

m t

t R

m m

t t

m m

m t

7 E

P O

a a

a a

a a

n n

a a

n n

a a

n n

n a

4 P

I l

l l

l l

l i

i l

l p

i i

l l

i i

i l

U T

F F

F F

F F

a a

F F

o a

a F

F a

a a

F t

t o

t t

t t

t L

C R

R R

R R

R n

n R

R L

n n

R R

n n

n R

E S

A B

2 O

H H

H H

H H

o o

H H

o o

H H

o o

o H

A L

R R

R R

R R

C C

R R

A C

C R

R C

C C

R T

O N

"2 "2

"2 "2

"2 "2

"2 "2

T 2

2 2

2 2

I E

2 2

2 2

2 2

N Z

/ /

/ /

/ /

/

/

/

/

/ /

/ /

/ / /

/

/

U I

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 S

2 1

1 1

1 1

1 1

1 2

2 1

1 1

2 1

1 1

1 A

B A

B N

0 1

2 5

6 7

8 9

0 1

2 3

3 4

5 6

6 7

8 O

2 2

2 2

2 2

2 2

3 3

3 3

3 3

3 3

3 3

3 I

T S

S S

S S

S S

S S

S S

S S

S S

S S

S S

A S

S S

S S

S S

S S

S S

S S

S S

S S

S S

N H

H H

H H

H H

H H

H H

H H

H H

H H

H H

G I

H H

H H

H H

H H

H H

H H

H H

H H

H H

H S

R R

R R

R R

R R

R R

R R

R R

R R

R R

R E

D 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

s s

s s

s s

s s

s s

s s

s s

s s

s s

s y

y y

y y

y y

y y

y y

y y

y y

y y

y y

S S

S S

S S

S S

S S

S S

S S

S S

q S S

i l

l l

l l

l l

l l

l l

l l

l l

l l

l l

a a

a a

a a

a a

a a

a a

a a

a a

a a

a v

v v

v v

v v

v v

v v

v v

v v

v v

v v

o o

o o

o o

o o

o o

o o

o o

o o

o o

o m

m m

m m

m m

m m

m m

m m

m m

m m

m m

M e

e e

e e

e e

e e

e e

e e

e e

e e

e e

E R

R R

R R

R R

R R

R R

R R

R R

R R

R R

S t

t t

t t

t t

t t

t t

t t

t t

t t

t t

T Y

a a

a a

a a

a a

a a

a a

a a

a a

a a

a S

e e

e e

e e

e e

e e

e e

e e

e e

e e

e H

H H

H H

H H

H H

H H

H H

H H

H H

H H

l l

l l

l l

l l

l l

l l

l l

l l

l l

l a

a a

a a

a a

a a

a a

a a

a a

a a

a a

u u

u u

u u

u u

u u

u u

u u

u u

u u

u d

d d

d d

d d

d d

d d

d d

d d

d d

d d

i i

i i

i i

i i

i i

i i

i i

i i

i i

i s

s s

s s

s s

s s

s s

s s

s s

s s

s s

e e

e e

e e

e e

e e

e e

e e

e e

e e

e R

R R

R R

R R

R R

R R

R R

R R

R R

'R R

f i

Il;l

TABLE 4.17-2 UNIT NO. 2 SUPPRES_SOR DATA RADIATION REMOVAL DESIGNATION _

SIZE LOCATION _

ACCESSIBILITY CATEGORY CATECORY SYSTEM 2-RH-HSS-39 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

I H

R 2-RH-HSS-40 2 1/2" Containment Basement I f

Residual Heat Removal Sys.

f R

2-RH-HSS-101 1 1/2" Containment Basement I Residual Heat Removal Sys.

H R

-l Residual Heat Removal Sys.

2-RH-HSS-102 1 1/2" Containment Basement I l

H D

]

Residual Heat Removal Sys.

2-RH-MSS-1 PSA-1/4 Containment Basement I 1

l H

D Residual Heat Removal Sys.

2-RH-MSS-2 PSA-3 Containment Basement I l

l l

4

_ _ _ - - _ _ _ _