UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION
- v m In the Matter of METROPOLITAN EDISON COMPANY, et. al.
Docket No. 50-320 OLA (Three Mile Island Nuclear Station, Unit 2)
{
AMENDMENT DF DRDER l
1.
tiGPU Nuclear Corporation, Metropolitan Edison Company, Jersey Central Power j
and Light Company and Pennsylvania Electric Company (collectively, the licensee) are the holders of Facility Operating License No. DPR-73, which had authorized operation of the Three Mile Island Nuclear Station, Unit 2 (TMI-2) at power levels up to 2772 megawatts thermal.
The facility, which is located in Londonderry Township, Dauphin County, Pennsylvania, is a pressurized water reactor previously used for the commercial generation of electricity.
By Order for Modification of License, dated July 20, 1979, the licensee's authority to operate the facility was suspended and the licensee's autnority was limited to maintenance of the facility in the shutdown cooling mode then in effect (44 F.R. 45271).
By further Order of the Director, Office of Nuclear Reactor Regulation, dated February 11, 1980, a new set of formal license requirements was imcosed to reflect the post-accident condition of tne 1
1 8204210517 Oc!0419 PDR ADOCK 05000
{
G
2 facility and to assure the continued maintenance of the current safe, stable, long-term cooling condition of the facility (45 F.R.11282). Although these requirements were imposed on the licensee by the Director's Order of 1
February 11, 1980, the TMI-2 license has not been formally amended.
The requirements are reflected in the proposed Recovery Mode Technical Specifi-cations presently pending before the Atomic Safety and Licensing Board.
Hereafter in this Amendment of Order, the requirements in question are identified by the applicable proposed Technical Specification.
II.
By letters. dated February 23, 1981, March 18, 1981, and October 6,1981, the W:emsee v..yo.wid
,5 to the RecoveryiMode Technical Specifications for.Three Mile ' Island Unit 2 (TMI-2) to reflect current plant conditions.
i Several categories of changes were proposed.
The proposed changes are summarized as follows:
A)
Deletion of Measurement Instrumentation and/or Surveillance Requirements for Equipment No Longer Required to be Operable.
1)
The NRC staff finds that the present instrumentation used to monitor the shutdown condition of the reactor such as pressure and temperature transmitters, reactor coolant system baron sampling, and two operable source range neutron instruments is adequate; therefore, the deletion of the operability requirement for all differential pressure transmitters for the reactor coolant system as stated in Table 3.3-9 is acceptaole as proposed.
2)
The proposed Recovery Mode Technical Specifications eliminated require-ments with respect to the Reactor Building Emergency Spray and Core Flooding Systems, but Table 3.3-10 of the Proposed Tecnnical Specifi-cations still contains operability requirements for the Core Flood Tank Level and Reactor Building Spray Pump Flow Instrumentation in addition l
"~
' ~
' ~~~ ~~
w
_C
~ ~
- _ ' z_ _T_'__' _
~.
to associated survaillance requirements (Table 4.3.10). The staff do:s not find the subject instrumentation essential to maintaining the reactor coolant system in its present safe condition and therefore finds tne proposed change acceptable.
3)
Proposed Technical Specification 3.7.10.2 (d) and (e) requires that the Deluge System located at the Hydrogen Purge Exhaust Filter and the Reactor Building Purge Exhaust Filter be operable with automatic initiation of water spray to minimize the fire hazards associated with the charcoal filter train. The charcoal has since been removed, there-1twe the#--, 2 deletion af 1he.Tegirirement.to lumintain the deluge 1
ksystems in an automatic initiation status is approved.
The deluge system would be isolated, thereby placing it in a manual made and therefore preventing spurious activation signals.
The fire detectors in the area are not affected and will continue to provide audible alarms.
4)
The licensee has requested deletion of the requirements of proposed Technical Specification 3.3.3.8 which requires the fire detection instrumentation for the Balance of Plant Diesel to be operable as imposed in the February 11, 1980, Order.
By letter dated April 28, 1980, the licensee proposed to delete these operability requirements for the BOP diesel generators and the 13.2Kv transmission line, re-This placing their capabilities with an existing 230Kv grid system.
modification was approved in the August 11, 1980, Modification of Order.
Since the diesels are located outside of the restricted area fence, are not located near any vital equipment, and will no longer be required to perform a safety function, the NRC staff concurs with the licensee's proposal.
_4 5)
Proposed Technical Specification 3.6.1.3 (b) presently requires the containment air locks to be operable with an overall leakage rate of less than or equal to 0.05La at Pa. 56.2 psig.
The licensee, however, has previously been granted an exemption from certain requirements of 10 CFR Part 50, Appendix J upon which Proposed Technical Specification 3.6.1.3 (b) is based.
Therefore the licensee has requested and we have approved the deletion of the subject section.
However, Section 3.6.1.3 (a) has not been deleted. The footnote indicating that surveillance requirement 4.5.1.32(a) wpresents anlexemption to Appendix J has also.been deleted since
/ Appendix J was recently modified (45 FR 62789) and now requires the same leak rate testing as is presently stated in Surveillance Requirement 4.6.1.3(a).
B)
Deletion of Systems or Structures No longer Required to be Operable or l
Maintain Their Original Design Criteria.
1)
The Proposed Recovery Mode Technical Specifications retained the Hydrogen Purge Cleanup System (proposed Technical Specification 3.6.4.3) to ensure the operability of the system in the event that purging of the containment building was approved by the NRC. On June 12, 1980, a Commission Memorandum and Order and a Temporary Modification of License were issued which authorized Metropolitan Edison Company to conduct a controlled purge of the containment building using that system with established off-site dose limits.
The purge began on June 28,1980 and was completed on July 11, 1980.
Subsequent permission to perfonn per1 odic purges using another system, the Reactor Building Purge System, i
I was granted by NRC letter NRC/TMI-80-119 from J.T. Collins to R.C. Arnolc, dated July 31, 1980.
The licensee has therefore requested tnat the
_..--__mm._,
Hydrogen Purge Cleanup System, Section 3.6.4.3, be deleted from the proposed Technical Specifications and Surveillance Requirement 4.6.4.3, since its purpose was fulfilled upon the completion of the June 29, 1980, purge and the use of the system will not be required to maintain the containment building in a safe condition for the remainder of the Recovery Mode.
Per the discussion in item (2) of the enclosed safety
~
evaluation, the NRC staff finds that the deletion of Sections 3.6.4.3 and 4.6.4.3 acceptable.
2)
Pmposed Technical Specification 3.7.10.1. requires that at least 3 of 4high pressure.mter amps.he:aperable to ensure that adequate fire
. suppression capability is available to confine and extinguish fires in The any portion of the plant where safety related equipment is located.
licensee has proposed to modify this requirement so that only 2 of 4 high pressure water pumps would be required operable.
The Fire Hazards Analysis for TMI detennined that only 2 of 4 high pressure pumps were needed to provide a required combined capacity greater than 3575 gpm.
The Bases for the Proposed Technical Specifications also reflect the same conclusion.
Therefore, the staff has concluded that enougn conser.-
vatism is present in the proposed Technical Specifications Section 3.7.10.1 to allow a change in the requirements to 2 of 4 high pressure I
water pumps being maintained in an operable condition without impairing the Fire Suppression System.
3)
The licensee proposed to add cccupational exposure considerations to the requirement stated in Section 5.2.2 of the Proposed Tecnnical Specifications to maintain the 50 psig maximum internal pressure and 286 F maximum internal temperature design.
This would limit 0
maintenance on the inside of the containment if radiological conditions posed a hazard to personnel.
The staff approves this acdition
-6 but also sought to more correctly state a reasonable containment des The licensee performed an analysis pressure that should be' maintained.
This evaluating the peak containment pressure under accident conditions.
analysis which was independen-ly verified by the NRC staff, co that the maximum potenti.al containment building pressure resulting a LOCA is approximately 2 psig.. Subsequent to the licensee's init
~
analysis, another evaluation was submitted by the licensee, (LL2 4arton to Snyder,12/4/81), which concluded that it is conceivable tha a fire inside of the containment building could increase the internal pressure: to greater than~ 2 psig, causing a Tailunt @1:heanss However, the fire analyzed by the licensee illus-penetration (R-626).
trated that even with the failure of penetration R-626, offsite releases would be less than 400 pCi with an average concentration at the statio The licensee's calculations and vent calculated to be 1.2 X 10-9 pCi/ml.
the staff's independent evaluation concludes that the releases wou d
well below the limits of 10 CFR 20 and within the scope of, impacts a in the " Final programmatic Environmental Impact Statement Rela Decentamination and Disposal of Radioactive Wastes Resulting fro Also to minimize t e Accident at TMI-2", dated March 1981.
March 28, 1979, potential for a fire induced overpressure, the licensee has hazards controls for the containment and is currently re-writing In addition, piping and electrical penetrations other than procedures.
R-626 will remain as is until R-626 are being redesigned to 5 psig.
accessibility and personnel 2xposure permit its possible upgrad 5 psig value.
The staff's independent evaluation agrees with the licensee's co and therefore Section 5.2.2 has been modified to state J
h 4 -
. design pressure of 2 psig. The design temperature will remain at 286 0F, C) Addition or Modification of System or Structure Requirements.
- 1) The licensee had originally requested that the requirements of Section 3.6.1.4 of the Proposed Technical Specifications which limits maximum primary containment pressure to <0 psig be deleted.
The basis for this request was that since the reactor building purge has removed most airborne contamination from inside containment, to the extent that normal leakage from the building will not affect the health and safety
. nf the public,the requirement could be relaxed.
However, based on discussions with the NRC staff on additional inside containment activities that could increase the airborne radioactivity concentration.
the licensee withdrew the requested modification to increase the maximum operating containment pressure to + 1 psig per LL2-81-091, Barton to Snyder, dated December 4, 1981.
2)
The proposed Technical Specifications do not require that the control room air inlet radiation monitor remain operable for all credible accident conditions.
Presently, a failure of the control room air inlet radiation monitor could prevent the automatic shifting of the control _.
room emergency air cleanup system to the recirculation mode in the event of an act uant.
The licensee has proposed to add the inlet monitor to proposed Technical Specification 3.7.7.1 and require it to be operable.
The staff agrees that this change enhances the safety of control room personnel and concurs with the modification.
3)
ANSI N18.1-1971, Section 4.4 is the currently referenced technical personnel qualification criteria in proposed Technical Specification 6.5.1.2 (c).
Specified in Section 4.4 are reactor engineering and physics, instrumentation and control, radiochemistry, and the radiation r.-
c-
8-protection disciplines.
The licensee has proposed to expand the academic requirements of the Plant Operations Review Committee (PORC) and the Generation Review Connittee to a broader area as discussed in ANSI /ANS-3.1-1978, Section 4.7.2 The proposed change to the qualifi-cations of the PORC and GRC members substitutes a basic requirement for a bachelor's degree plus three years of professional level experience in lieu of the existing requirement for only five years experience or, at most, a bachelor's degree plus one year of experience. The staff is in agreement that by using the proposed u h inh qualifications :for.? ORC 31mdlliRC 1nembers will be -higner
.than those presently required in the existing Proposed Technical Specifications and, accordingly we conclude that the proposed change is acceptable.
D)
The Clarification of Ambiguity in Proposed Requirements.
l 1)
The " action" statement of Proposed Technical Specification Section 3.9.12 (a) states that "with the fuel handling building / auxiliary I
building air cleanup system inoperable.....".
However, it is not clear in this statement or statement 3.9.12 (b) that the fuel handling building and the auxiliary building air cleanup systems are independent of each other and that one of the two systems being inoperable snould not affect any radioactive movements in the building solely associated with the other operating system.
The staff concurs with a modification to 3.9.12 (a) and (b) as requested by the licensee to eliminate any ambiguity 2)
Section 3.6.1.1 of the Proposed Technical Specifications presently contains an incorrectly used "and" which has the unintended effect of requiring that containment isolation be maintained wnen one containment isolation valve per penetration is open or inoperable by (a) at least one deactivated automatic valve secured in the isciation condition anc e
.g.
(b) at least one closed manual valve or blind flange.
It was intended that methed (a) or (b) would suffice when a penetration isolation valve was inoperable.
Therefore, the licensee's request to so modify the specification is acceptable.
3)
Paragraph 4.1.1.1.j. of the Surveillance Requirements presently indicates that water filled tanks, the surge tank and the degassed water supply tank shall be sampled to verify that they contain borated water.
The proposed change by the licensee specifies.wnat. tanks-are to be sampled uby using more accurate system terminology and is, therefore, acceptable.
Also,'Section.4.1.1.1.j.2 specifies sampling to confirm a. dissolved gas concentr'ation of less than 15 sec/kg of water.
An (*) and footnote has also been added as requested in order to more specifically state where the most representative sample should be taken for water being added to the reactor coolant system via the Standby Pressure Control System.
The staff's safety assessment of this matter is set forth in the concurrently issued Safety Evaluation.
This evaluation concluded, in material part, that
- the amendment of order does not involve a significant hazards consideration and that there is reasonable assurance that the health and safety of the public will not be endangered by operation in the modified manner.
Prior public notice of the amendment of order was therefore not recuired and the amendment of order is effective upon issuance.
It was further determined that the amendment of order does not authorize a change in effluent types or total amounts nor an increase in power level and i
will not result in any significant environmental imoact.
In lignt of tnis determination, it was c0nciuced tnat the instant action is insignifican; fr:m
the standpoint of environmental impact and, pursuant to 10 CFR g51.5 (d) (4),
that an environmental impact statement or environmental impact appraisal need not be prepared herewith.
III.
Accordingly, pursuant to the Atomic Energy Act of 1954, as amended, the Director's Order of February 11, 1980, is hereby revised to incorporate the l
deletions, additions, and modifications set forth in Attachment A hereto.
flor further detailsiwt2. mas ;this -action, see (1) Letter 1to B. Snyder,.
"11SIEtC, from G. K. Hovey, liet-Ed/GPU, Technical Specification Change Request No. 25.
J.
dated February 23,1981,(LL2-81-0049);(2)
Letter to B. Snyder, USNRC, from G. K. Hovey, Met-Ed/GPU, Technical Specification Change Request No. 26, Addendum A, dated March 18,1981,(LL2-81-0055);(3)
Letter to B. Snyder, USNRC, from G. K. Hovey, Met-Ed/GPU, Technical Specification Change Request No. 26 Addendum S, dated October 6,1981 (LL2-81-0229); (4) Modification of Order dated August 11, 1980;(5)
Letter to R. C. Arnold, Met-Ed, from J. T. Collins, USNRC, granting permission to perform periodic purges using the Reactor Building Purge System, dated July 31, 1980; (6)
Memorandum and Order dated June 12, 1980; (7)
Order for Temporary Modification of License, dated June 12, 1980; and (8) the Director's Order of February 11, 1980.
All of the above documents are available for inspection at the Commission's 2.
Public Document Room,1717 H Street, N.W., Washington, D.C., and at the Comission's Local Public Document Room at the State Library of Pennsylvania, l
Government Publications Section, Education Building, Commonwealth and Walnut
(
Streets, Harrisburg, Pennsylvania 17126.
FOR THE NUCLEAR REGULATORY C0ffilSSION As/ AL 1
4tarold R. 3enton,'Di mctor
? Office of Nuclear' Reactor Regulation
[
' Tffective Date:
Aoril 7,1982 Dated at Bethesda, Maryland i
l l
l l
w
-.- - --=
my w
References:
Letter to Bernard J. Snyder, NRC, from G. K. Hovey, Metropolitan Edison 1.
Company, " Technical Specification Change Report No. 26", LL2-81-0049, February 23, 1981.
Letter to Bernard J. Snyder, NRC, from G. K. Hovey, Metropolitan Edison 2.
Company, " Technical Specification Change Request No. 26, Addendum A",
LL2-81-0055, March 18, 1979.
Letter to Lake Barrett, NRC, from G. K. Hovey, Metropolitan Edison Company, 3.
" Request for an Exemption from the Testing Requirements of 10 CFR 50, Appendix J", LL2-81-0094, May 11, 1981.
Letter to G. K. Hovey, Metropolitan Edison Company, from 8. J. Snyder, 4
NRC, " Appendix J Exemption Request", September 2,1981.
Final Supplement to the Envimnmental Impact Statement for Unit 2, 5.
NUREG-0112, December 1976.
Fire Protection Program Evaluation, Three Mile Island, Unit 2, June 1977.
15.
Final Programmatic Environmental Impact Statement, NUREG-0683, March 1981.
7.
Letter to Bernard J. Snyder, NRC, from G. K. Hovey, Metropolitan Edison 8.
l Company, " Technical Specification Change Request No. 26, Addendum B",
l LL2-81-0229, October 6, 1981.
.