ML20053A366

From kanterella
Jump to navigation Jump to search
Forwards marked-up Tech Specs to Close Out Open Items Identified in NRC
ML20053A366
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 05/19/1982
From: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20053A367 List:
References
NUDOCS 8205260023
Download: ML20053A366 (2)


Text

-

o SOUTH CAROLINA ELECTRIC & GAS COMPANY POST OFFICE BOX 764 COLUMBI A. S. C. 29218 May 19, 1982 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Camission Washington, D.C.

20555

Subject:

Virgil C. Sumer Nuclear Station Docket No. 50/395 Technical Specifications

Dear Mr. Denton:

Mr. Youngblood's letter of May 10, 1982, identified in Enclosure 2 three Technical Specifications that reain open. The following information is provided to close these ites.

1.

Specification 3/4.3.2, " Engineered Safety Features Actuation Instrumentation."

The manual Phase "B" Isolation (Item 3.b.1 of Table 3.3-3) has been eliminated because this function is performed by the manual switches already listed for the Reactor Building Spray (Item 2.a of Table 3.3-3).

The manual Purge and Exhaust Isolation (Item 3.c.1 of Table 3.3-3) has also been eliminated because this function is performed by the manual switches already listed for Safety Injection (Item 1.a),

Reactor Building Spray (It s 2.a) or Phase "A" Isolation (Itsn 3.a.1).

Enclosed is Page 3/4 3-18 with the proposed change. Also pages 3/4 3-26 and 3/4 3-36 are enclosed marked with the corresponding changes for Table 3.3-4 and 4.3-2.

2.

Specification 3/4.9.11, " Spent Fuel Pool Ventilation System."

Please disregard the proposed change to this Specification transmitted by my April 12, 1982 letter, to Mr. Denton. The ventilation system design requires that one exhaust fan operates continuously. The March 3, 1982, revision of this Specification in the Proof and Review Copy of the Sumer-Unit 1 Technical Specifications is acceptable.

3.

Specification 3/4.6.4, " Containment Isolation valves."

Enclosed is a revised Table 3.6-1 which includes the additional valves defined by Mr. Hearn of the NRC staff in his telephone conversation with Mr. L. D. Shealy on May 10, 1982.

%gOw 8205260028 A

Mr. H. R. Denton May 19, 1982 Page 2 Please contact Mr. L. D. Shealy if you have any questions.

Very truly yours, fA

/

/

T. C. Nichols, Jr.

Senior Vice President Power Operations IDS:'ICN:Ikb Attachnents cc:

V. C. Sunner (w/o attach.)

G. H. Fischer (w/o attach.)

H. N. qmas T. C,

ols, Jr.

(w/o attach.)

M. B. Whitaker, Jr.

J. P. O'Reilly H. T. Babb D. A. Nauman C. L. Ligon (NSRC)

W. A. Williams, Jr.

R. B. Clary O. S. Bradham L. D. Shealy A. R. Koon M. N. Browne G. J. Braddick J. L. Skolds I

J. B. Knotts, Jr.

B. A. Bursey M. J. Virgilio l

J. B. Cookinham W. R. Kane NPCF File 1

\\

-