00 TABLE 3.3-3 (Continued)

M$

O3 ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION cy g 10 8 HINIMUM k

H TOTAL NO.

CHANNELS CllANilELS APPLICABLE O*

FUNCTIONAL UNIT OF CilANNELS TO TRIP OPERABLE MODES ACTION (C

C/t 3.

CONTAINMENT ISOLATION a.

Phase " A" Isolation A

1)

Hanual 2

1 2

1,2,3,4 18 See 1 above for all safety injection initiating functions and requirements.

2)

Safety Injection 3)

Automatic Actuation Logic and Actuation Relays 2

1 2

1,2,3,4 14 w.).

b.

Phase "B" Isolation W- )--Manual 2

1 2

1, 2, 3, i 18 g

I' 2)

Automatic Actuation 2

1 2

1,.2, 3, 4 14 Logic and Actuation Relays 3

1,2,3 16 a

2 2 )) - Reactor Building Pressure--liigh-3 P

c.

Purge and Exhaust Isolation

-+)-Mantial 2

_1 2

1, 2, 3, '

17 3 2)

Safety Injection See 1 above* for,all safety injection initiating functions and requirements.

2 A)

Containment Radio-4 2

3 1,2,3,4 17 activity-liigh E

/ /)

Automatic Actuation 2

1 2

1,2,3,4 17 56 Logic and Actuation Relays u

is

~

e n-w

.oom

O D

O g

TABLE 3.3-4 (Continued) 3g ENGINEEREO SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION TRIP SETPOINTS c

5 FUNCTIONAL UNIT TRIP SETPOINT ALLOWABLE VALUES

~

H 3.

CONIAINHENT ISOLATION a.

Phase "A" Isolation 1.

Manual Not Applicable Not Applicabla 2.

Safety Injection Not Applicable Nnt Applicabla 3.

Automatic Actuation Logic Not Applicable Not Applicabla and Actuation Relays b.

Phase "B" Isolation "et A ;;.lic.bl..

1.

"r=!

Net f.pplicab!c i

f, E.

Automatic Actuation Logic Not Applicable Not Applicable and Actuation Relays w

h

2. A.

Reactor BuildinD Pressure--lli0h-3 $ 11.4 psig

$ 12.65 psig c.

Purge and Exhaust Isolation 4.

N nual Net-Applicahic "ct-A yHeehle-l S. (.

Safety Injection See 1 above for all safety injection trip setpoints and _...

allowable values.

8 y

2. J.

Containment Radioactivity-liigh

$ 2 x back round 1 2 x back0round 0

/, /.

Automatic Actuation Logic and Not Applicable Not Applicable Q

Actuation Relays g

4.

STEAM LINE ISOLATION

a a.

Manual Not Applicable Not Applicable h

b.

Automatic Ac.tuation Logic Not Applicable Not Applicable C9 and Actuation Relays

.ca c.

Reactor Building Pressure--lii h-2

-< 5.7 psig

-.< 6.95 psig

.c;J.,

0 gW e

e e

I

O O

r-9; TABLE 4.3-2 (Continued) u>

C 3

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION g

SURVEILLANCE REQUIREMENTS E

TRIP H0 DES FOR y

AllALOG ACTUATING g

CllANNEL DEVICE MASTER SLAVE WilICil CilANNEL CHANNEL OPERATIONAL OPERATIONAL ACTUATION RELAY RELAY SURVEILLANCE FUNCTIONAL UllIT CllECK CALIBRATION TEST TEST LOGIC TEST TEST TEST IS REQUIRED

3. CONIAINMENT ISOLATION a.

Phase "A" Isolation

1) Hanual H.A.

H.A.

"N.A.

R N.A.

N.A.

H.A.

1, 2, 3, 4 See 1 above for all Safety Injection Surveillance Requirements

2) Safety Injection
3) Automatic Actuation H.A.

N.A.

H.A.

H.A.

M(1)

M(1)

Q 1,2,3,4 4

R' Logic and Actuation Relays J, b. Phase "B" Isolation 1-2 4

- -+)-Hanual NrA.

NrA.

HrA.

R HrA.

HrA.

HrA.

7 7 cn

~/ /) Automatic Actuation N.A.

N.A.

N.A.

H.A.

H(1)

M(1)

Q 1, 2, 3, 4 Logic and Actuation Relays 2,. J) Reactor Building S

R H

N.A.

N.A.

N.A.

N.A.

1,2,3 Pressure--High-liigh-liigh c.

Purge and Exhaust Isolation

1) Automatic Actuation H.A.

N.A.

H.A.

N.A.

M(1)

M(1)

Q 1,2,3,4 gg Logic and Actuation Relays

2) Containment Radio-S R

H N.A.

N.A.

N.A.

N.A.

1,2,3,4

'a g

activity-liigh

3) Safety Injection See 1 above for all Safety Injection Surveillance Requirements.

~ _.....

F ^j

.3 8

5 r~, n m'

TABLE 3.6-1 N

~

h

~

be_-

~

CONTAINMENT ISOLATION VALVES g

8 MAXIMUM 7-Q VALVE NUMBER ISOLATION TIME

^ r y

A.

PHASE "A" ISOLATION FUNCTION (SEC) 1.

7501-AC CRDM Coolant Water InleteLine 40

~ 2.

7502-AC CRDM Coolant Water Inlet Line 40 3,

7503-AC CRDM Coolant Water Outlet Line 40

~

4.

7514-AC CRDM Coolant Water Outlet Line 40 5.

503A-BD #

Steam Generator A Blowdown Line 40 6.

503B-ED #

Steam Generator B Blowdown Line 40

^

7.

503C-BD #

Steam Generator C Blowdown Line 40

~

c 8.

8100-CS Reactor Coolant Pump Seal Water Return 40 9.

8112-CS Reactor Coolant Pump Seal Water Return 40 10.

8149A-CS Reactor Coolant To Letdown Heat Exchanger 40 11.

8149B-CS Reactor Coolant To Letdown Heat Exchanger 40

'12.

8149C-CS Reactor Coolant To_ Letdown Heat Exchanger 40 "l,

s tt 13.

8152-CS Reactor Coolant To Letdown Heat Exchanger 40 14.

6797-FS Fire Service Deluge To Charcoal Filters 40 i

15.

6050A-HR Normal Reactor Building Pressure Line 40 I

G 16.

6054-HR Normal Reactor Building Pressure Line 40

[

17.

2660-IA Reactor Building Instrument Air Inlet Line 40 18, 2662A-IA Reactor Building Instrument Air Suction Line 40

~

19.

2662B-IA Reactor Building Instrument Air Suction Line 40 20.

6242A-ND Reactor Building Sump Drain 40 21.

6242B-ND Reactor Building Sump Drain 40 22, 8028-RC Pressurizer Relief Tank Makeup Water Line 40 23.

8033-RC Prehsurizer Relief Tank N2 Supply-Return Line 40 24.

8047-RC Pressurizer Relief Tank N2 Supply-Return Line 40 25.

8860-SI Full Line To Accumulators 40 26.

8880-SI Accumulator Nitrogen Supply 40 27, 8871-SI Accumulator Test Line 40 28.

896 FSI Accu $ulator Test Line 40 i

29, 9311A-SS Sa'mpling Line Supply To Radiation Monitor 40 30.

9311B-SS Sai.pling',Line Supply To Radiation Monitor 40 s

e

/

+

l TABLE 3.6-1 (Continued) s CONTAINMENT ISOLATION VALVES i

g MAXIMUM W VALVE NUMBER ISOLATION TLME j

A.

PHASE "A" ISOLATION (Continued)

FUNCTION (SEC) 31.

9312A-SS Sampling Line. Supply Return From Radiation Monitor 40 32.

9312B-SS Sampling Line Return Return From Radiation Monitor 40 33.

9339-SS Sample Return Line To PRT 40 34.

9341-SS Sample Return Line To PRT 40 35.

9356A-SS Sampling Line From Pressurizer 40 36.

9356B-SS Sampling Line From Pressurizer 40 37.

9357-SS Sampling Line From Pressurizer 40

.38.

9364B-SS Sampling Lines From Reactor Coolant Loop B 40 39.

9365B-SS Sampling Lines From Reactor Coolant Loop B 40 40.

9364C-SS Sampling Lines From Reactor Coolant Loop C 40 1

41.

9365C-SS Sampling Lines From Reactor Coolant Loop C 40 42.

9387-SS Sampling Line From Accumulators 40 w-43.

9398A-SS #

Sampling Line From Steam Generator A Blowdown 40 37 44.

9398B-SS #

Sampling Line From Steam Generator B Blowdown 40 j

p 45.

9398C-SS #

Sampling Line From Steam Generator C Blowdown 40 w

46.

7126-WL Reactor Coolant Drain Tank Vent Header 40 j

47.

7150-WL Reactor Coolant Drain Tank Vent Header 40 l

48.

1003-WL Reactor Coolant Drain Tank Discharge To Waste 40 49.

7136-WL Reactor Coolant Drain Tank _ Discharge To Wasta 40 B.

PHASE "B" ISOLATION

{

l.

9568-CC Component Cooling To R. C. Pumps Bearings 60 l

2.

9600-CC Component Cooling To R. C. Pumps 60 3.

9605-C Component Cooling From R. C. Pumps Bearings 60 4.

9606-CC Component Cooling From R. C. Pumps Bearings 60 i

5.

1633A-FW #

Chemical Feed Line To Feadwater Loop A 60 6.

1633B-FW #

Chemical Feed Line To Feedwater Loop B 60 7.

1633C-FW #

Chemical Feed Line To Feedwater Loop C 60 C.

REACTOR BUILDING PURCE SUPPLY AND EXHAUST ISOLATION 1.

0001A-AH Reactor Building Purge Supply 5

2.

0001B-All Reactor Building Purge Supply 5

3.

0002A-All Reactor Building Purge Exhaust 5

un TABLE 3.6-1 (Continutd) s fg CONTAINMENT ISOLATION VALVES I

VALVE NUFBER MAXIMUM h

C.

REACTOR BUILDING PURGE SUPPLY ISOLATION TIME d

AND EXHAUST ISOLAIION (Continued)

FUNCTION (SEC) 6 4.

0002B-AH Reactor Building Purge Exhaust 5

5.

6056-HR Alternate Reactor Building Purge Supply Line 5

6.

6057-HR Alternate Reactor Building Purge Supply Line 5

7, 6066-HR Alternate Reactor Building Purge Exhaust Line 5

8.

6067-HR Alternate Reactor Building Purge Exhaust Line 5

D.

MANUAL (I) 1.

8767-DN Demineralized Water Line N/A 2.

8768-DN Demineralized Water Line N/A 3.

6772-FS Fire Service Hose Reel Supply N/A 4.

6773-FS Fire Service Hose Reel Supply N/A 5.

2679-IA Breathing Air Supply Line N/A ti 6.

2680-IA Breathing Air Supply Line N/A 7.

6587-NG Nitrogen Supply To Steam Generators N/A i'

8.

8090A-RC Dead Weight Tester N/A E'

9.

8090B-RC Dead Weight Tester N/A 10.

2912-SA Reactor Building Service Air N/A 11.

6671-SF Refueling Cavity Drain Line N/A 12.

6672-SF Refueling Cavity Drain Line N/A 13.

6697-SF Refueling Cavity Fill Line N/A 14.

6698-SF Refueling Cavity Fill Line N/A 15.

7135-WL Reactor Coolant Drain Tank Discharge To Waste N/A E.

REMOTE MANUAL (2) 1.

9602-CC Component Cooling To R. C. Pumps N/A 2.

8102A-CS Seal Injection To Reactor Coolant Pump A N/A 3.

8102B-CS Seal Injection To Reactor Coolant Pump B N/A 4,

8102C-CS Seal Injection To Reactor Coolant Pump C N/A e

9

vs TABLE 3.6-1 (Continu:d) m M

CONTAINMENT ISOLATION VALVES i

E MAXIMUM E VALVE NUMBER ISOLATION TIME E.

REMOTE MANUAL (Continued)

FUNCTION (SEC) 5.

8107-CS Charging Line To Regenerative Heat Exchange N/A 6.

6050 D-IIR Hydrogen Analyzer Return Line N/A 7.

6051A-HR Hydrogen Analyzer Supply Line N/A 8.

6051B-HR Hydrogen Analyzer Supply Line N/A 9.

6051C-HR Hydrogen Analyzer Supply Line N/A 4

10.

6CS2A-HR Hydrogen Analyzer Return Line N/A 11, 6052B-HR Hydrogen Analyzer Return Line N/A 12.

6053A-HR liydrogen Analyzer Supply Line N/A 13.

6053B-HR Hydrogen Analyzer Supply Line N/A 14.

8701A-RH RHR Pump Suction From Reactor Coolant Loop A N/A 15.

8701B-RH RHR Pump Suction From Reactor Coolant Loop C N/A 16.

8801A-SI Boran Injection Tank To Reactor Coolant Loops N/A t) 17.

88013-SI Boran Injection Tank To Reactor Coolant Loops N/A I

8' 18.

8811A-SI RHR Pump A Suction From Recirculation Sump N/A i

19.

8811B-SI RIIR Pump B Suction From Recirculation Sump N/A g

20.

8884-SI High Head Safety Injection To Reactor Coolant Loops N/A e

21.

8885-SI High Head Safety Injection To Reactor Coolant Loops N/A 22.

8886-SI High llead Safety Injection To Reactor Coolant Loops N/A 23.

8888A-SI Low Head Safety Injection To Reactor Coolant Loops N/A 24.

8888B-SI Low IIead Safety Injection To Reactor Coolant Loops N/A 25.

8889-SI Low liead Safety Injection To Reuctor Coolant Loops N/A 26.

3003A-SP Supply To Reactor Building Spray Nozzles N/A 27.

3003B-SP Supply To Reactor Building Spray Nozzles N/A 28.

3004A-SP Spray Pump A Suction From Recirculation Sump N/A 29.

3004B-SP Spray Pump B Suction From Recirculation Sump N/A 30.

3203A-SW Service Water From Reactor Building Cooling Unit A N/A 31.

3103B-SW Service Water From Reactor Building Cooling Unit B N/A 32.

3106A-SW Service Water To Reactor Building Cooling Unit A N/A 33.

3106B-SW Service Water To Reactor Building Cooling Unit.B,

N/A 34.

3110A-SW Service Water To Reactor Building Ccoling Unit A N/A 35, 3110B-SW Service Water To Reactor Building Cooling Unit B N/A'

+

TABLE 3.6-1 (Continurd)

CONTAINMENT ISOLATION VALVES MAXLWM VALVE NUMBER ISOLATION TIME F.

CHECK FUNCTION (SEC)

+

1.

7541-AC CRDM Coolant Water Inlet Line N/A 2.

7544-AC CRDM Coolant Water Outlet Line N/A I

g 3.

9570-CC Component Cooling To R. C. Pump Bearings N/A r.

4.

9689-CC Component Cooling From R. C. Pump Bearings N/A "i

5.

8103-CS Reactor Coolant Fump Seal-Water Return N/A 6.

8368A-CS Seal Injection,To R. C. Pump A N/A 7.

8368B-CS Seal Injection To R. C. Pump B N/A 8.

8368C-CS Seal Injection To R. C. Pump C N/A 9.

8381-CS Charging Line To Regenerative Heat Exchanger N/A 10.

6799-FS Elre Service Deluge To Charcoal Filters N/A 11.

2661-IA Instrument Air Supply To Reactor Building N/A 12.

6588-NG Nitrogen Supply To Steam Generators N/A 13.

8046-RC Pressurizer Relief Tank Makeup Water Line N/A 14.

2913-SA Service Air Supply To Reactor Building N/A ti 15, 3009A-SP Supply To Reactor Building Spray Nozzles -

N/A 16.

3009B-SP Supply To Reactor Building Spray Nozzles N/A T'

17.

8947-S1 Accumulator Nitrogen Supply N/A El 18.

8861-SI Fill Line To Accumulators N/A o

j

  1. Valve not subject to Type "C" leakage test.

=

(1) Manual valves may be opened on an intermittent basis under adminstrative control.

(2) Remote manual valve positions are maintained by administrative control.

1 e