CHAPTER II CONTAINMENT STRUCTURES
II-1 II CONTAINMENT STRUCTURES A.
PRESSURIZED WATER REACTOR CONTAINMENTS B.
BOILING WATER REACTOR CONTAINMENTS
II-3 II PRESSURIZED WATER REACTOR CONTAINMENTS A1.
CONCRETE CONTAINMENTS (REINFORCED AND PRESTRESSED)
A2.
STEEL CONTAINMENTS A3.
COMMON COMPONENTS
II A1-1 A1.
CONCRETE CONTAINMENTS (REINFORCED AND PRESTRESSED)
Systems, Structures, and Components This section addresses the elements of pressurized water reactor (PWR) concrete containment structures. Concrete containment structures are divided into three elements: (i) concrete, (ii) steel, and (iii) prestressing systems.
System Interfaces Functional interfaces include the primary containment heating and ventilation system (VII.F3),
containment isolation components (V.C), and the containment spray system (V.A). Physical interfaces exist with any structure, system, or component that either penetrates the containment wall, such as the main steam (MS) system (VIII.B1) and the feedwater (FW) system (VIII.D1), or is supported by the containment structure, such as cranes (VII.B). The containment structure basemat typically provides support to the nuclear steam supply system components and containment internal structures.
II A1-2 II CONTAINMENT STRUCTURES Table A1 Concrete Containments (Reinforced and Prestressed)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.A1.CP-87 3.5-1, 016 Concrete (accessible areas):
dome; wall; basemat; ring girders; buttresses Concrete Air - indoor uncontrolled, air -
outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL" No II.A1.CP-31 3.5-1, 018 Concrete (accessible areas):
dome; wall; basemat; ring girders; buttresses Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S2, "ASME Section XI, Subsection IWL" No M
II.A1.CP-33 3.5-1, 019 Concrete (accessible areas):
dome; wall; basemat; ring girders; buttresses Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S2, "ASME Section XI, Subsection IWL" No II.A1.CP-32 3.5-1, 020 Concrete (accessible areas):
dome; wall; basemat; ring girders; buttresses Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S2, "ASME Section XI, Subsection IWL" No
II A1-3 II CONTAINMENT STRUCTURES Table A1 Concrete Containments (Reinforced and Prestressed)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.A1.CP-68 3.5-1, 021 Concrete (accessible areas):
dome; wall; basemat; ring girders; buttresses; reinforcing steel Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL" No II.A1.CP-100 3.5-1, 024 Concrete (inaccessible areas): dome; wall; basemat; ring girders; buttresses Concrete Air - indoor uncontrolled, air -
- outdoor, groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL," and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No
II A1-4 II CONTAINMENT STRUCTURES Table A1 Concrete Containments (Reinforced and Prestressed)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.A1.CP-147 3.5-1, 011 Concrete (inaccessible areas): dome; wall; basemat; ring girders; buttresses Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.A1.CP-67 3.5-1, 012 Concrete (inaccessible areas): dome; wall; basemat; ring girders; buttresses Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
II A1-5 II CONTAINMENT STRUCTURES Table A1 Concrete Containments (Reinforced and Prestressed)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.A1.CP-102 3.5-1, 014 Concrete (inaccessible areas): dome; wall; basemat; ring girders; buttresses Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.A1.CP-97 3.5-1, 023 Concrete (inaccessible areas): dome; wall; basemat; ring girders; buttresses; reinforcing steel Concrete Any Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL," and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No
II A1-6 II CONTAINMENT STRUCTURES Table A1 Concrete Containments (Reinforced and Prestressed)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.A1.CP-34 3.5-1, 003 Concrete: dome; wall; basemat; ring girders; buttresses Concrete Air - indoor uncontrolled, air -
outdoor Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
II.A1.CP-101 3.5-1, 001 Concrete: dome; wall; basemat; ring girders; buttresses Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S2, "ASME Section XI, Subsection IWL," and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" Yes
II A1-7 II CONTAINMENT STRUCTURES Table A1 Concrete Containments (Reinforced and Prestressed)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.A1.C-07 3.5-1, 002 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes M
II.A1.C-11 3.5-1, 008 Prestressing system: tendons Steel Air - indoor uncontrolled, air -
outdoor Loss of prestress due to relaxation; shrinkage; creep; elevated temperature TLAA, SRP-SLR Section 4.5, "Concrete Containment Tendon Prestress,"
and/or SRP-SLR Section 4.7, "Other Plant-Specific Time-Limited Aging Analyses" Yes II.A1.C-10 3.5-1, 032 Prestressing system: tendons; anchorage components Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to corrosion AMP XI.S2, "ASME Section XI, Subsection IWL" No
II A1-8 II CONTAINMENT STRUCTURES Table A1 Concrete Containments (Reinforced and Prestressed)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.A1.CP-35 3.5-1, 035 Steel elements (accessible areas):
liner; liner anchors; integral attachments Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes E
II.A1.CP-98 3.5-1, 005 Steel elements (inaccessible areas): liner; liner anchors; integral attachments Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II A2-1 A2.
STEEL CONTAINMENTS Systems, Structures, and Components This section addresses the elements of pressurized water reactor (PWR) steel containment structures. Steel containment structures are divided into two elements: (i) steel and (ii) concrete.
System Interfaces Functional interfaces include the primary containment heating and ventilation system (VII.F3),
containment isolation components (V.C), and the containment spray system (V.A). Physical interfaces exist with any structure, system, or component that either penetrates the containment wall, such as the main steam (MS) system (VIII.B1) and the feedwater (FW) system (VIII.D1), or is supported by the containment structure, such as cranes (VII.B). The containment structure basemat typically provides support to the nuclear steam supply system components and containment internal structures.
II A2-2 II CONTAINMENT STRUCTURES Table A2 Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.A2.CP-51 3.5-1, 018 Concrete (accessible areas):
basemat Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No M
II.A2.CP-58 3.5-1, 019 Concrete (accessible areas):
basemat Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No II.A2.CP-72 3.5-1, 016 Concrete (accessible areas):
basemat Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No
II A2-3 II CONTAINMENT STRUCTURES Table A2 Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.A2.CP-155 3.5-1, 020 Concrete (accessible areas):
basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No M
II.A2.CP-74 3.5-1, 021 Concrete (accessible areas):
basemat; reinforcing steel Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No
II A2-4 II CONTAINMENT STRUCTURES Table A2 Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.A2.CP-70 3.5-1, 011 Concrete (inaccessible areas): basemat Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
II A2-5 II CONTAINMENT STRUCTURES Table A2 Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.A2.CP-104 3.5-1, 012 Concrete (inaccessible areas): basemat Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes II.A2.CP-71 3.5-1, 024 Concrete (inaccessible areas): basemat Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No
II A2-6 II CONTAINMENT STRUCTURES Table A2 Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.A2.CP-53 3.5-1, 014 Concrete (inaccessible areas): basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.A2.CP-75 3.5-1, 023 Concrete (inaccessible areas): basemat; reinforcing steel Concrete Any Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No E
II.A2.CP-69 3.5-1, 001 Concrete: basemat Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" Yes
II A2-7 II CONTAINMENT STRUCTURES Table A2 Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.A2.C-07 3.5-1, 002 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes M
II.A2.CP-35 3.5-1, 035 Steel elements (accessible areas):
liner; liner anchors; integral attachments Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes E
II.A2.CP-98 3.5-1, 005 Steel elements (inaccessible areas): liner; liner anchors; integral attachments Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II A3-1 A3.
COMMON COMPONENTS Systems, Structures, and Components This section addresses the common components of pressurized water reactor (PWR) containment structures. The common components include (i) penetration sleeves and bellows, (ii) dissimilar metal welds, (iii) personnel airlock, (iv) equipment hatch, (v) seals, (vi) gaskets, and (vii) moisture barriers.
System Interfaces Functional interfaces include the primary containment heating and ventilation system (VII.F3),
containment isolation components (V.C), and the containment spray system (V.A). Physical interfaces exist with any structure, system, or component that either penetrates the containment wall, such as the main steam (MS) system (VIII.B1) and the feedwater (FW) system (VIII.D1), or is supported by the containment structure, such as cranes (VII.B). The containment structure basemat typically provides support to the nuclear steam supply system components and containment internal structures.
II A3-2 II CONTAINMENT STRUCTURES Table A3 Common Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.A3.CP-37 3.5-1, 027 Metal liner, metal plate, airlock, equipment hatch, CRD hatch; penetration sleeves; penetration bellows Steel; stainless steel; dissimilar metal welds Air - indoor uncontrolled, air - outdoor Cracking due to cyclic loading (CLB fatigue analysis does not exist)
AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No M
II.A3.C-13 3.5-1, 009 Metal liner, metal plate, personnel airlock, equipment hatch, CRD hatch, penetration sleeves; penetration bellows Steel; stainless steel; dissimilar metal welds Air - indoor uncontrolled, air - outdoor Cumulative fatigue damage due to fatigue (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.6, "Containment Liner Plate and Penetration Fatigue Analysis" Yes II.A3.CP-40 3.5-1, 026 Moisture barriers (caulking, flashing, other sealants)
Elastomer, rubber and other similar materials Air - indoor uncontrolled Loss of sealing due to wear, damage, erosion, tear, surface cracks, other defects AMP XI.S1, "ASME Section XI, Subsection IWE" No M
II.A3.CP-36 3.5-1, 035 Penetration sleeves Steel; dissimilar metal welds Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II A3-3 II CONTAINMENT STRUCTURES Table A3 Common Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.A3.CP-38 3.5-1, 010 Penetration sleeves; penetration bellows Stainless steel; dissimilar metal welds Air - indoor uncontrolled, air - outdoor Cracking due to SCC AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes II.A3.C-16 3.5-1, 028 Personnel airlock, equipment hatch, CRD hatch Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No M
II.A3.CP-39 3.5-1, 029 Personnel airlock, equipment hatch, CRD hatch: locks, hinges, closure mechanisms Steel Air - indoor uncontrolled, air - outdoor Loss of leak tightness due to mechanical wear AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No II.A3.CP-148 3.5-1, 031 Pressure-retaining bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE" No
II A3-4 II CONTAINMENT STRUCTURES Table A3 Common Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.A3.CP-150 3.5-1, 030 Pressure-retaining bolting Steel Any Loss of preload due to self-loosening AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No II.A3.CP-41 3.5-1, 033 Seals and gaskets Elastomer, rubber and other similar materials Air - indoor uncontrolled, air - outdoor Loss of sealing due to wear, damage, erosion, tear, surface cracks, other defects AMP XI.S4, "10 CFR Part 50, Appendix J" No M
II.A3.CP-152 3.5-1, 034 Service Level I coatings Coatings Air - indoor uncontrolled, treated water Loss of coating or lining integrity due to blistering, cracking, flaking, peeling, delamination, rusting, physical damage AMP XI.S8, "Protective Coating Monitoring and Maintenance" No
II B-1 II BOILING WATER REACTOR CONTAINMENTS B1.
MARK I CONTAINMENTS B2.
MARK II CONTAINMENTS B3.
MARK III CONTAINMENTS B4.
COMMON COMPONENTS
II B1-1 B1 MARK I CONTAINMENTS Systems, Structures, and Components This section addresses the elements of boiling water reactor (BWR) Mark I containment structures. Steel containments are discussed in II.B1.1 and concrete containments are discussed in II.B1.2.
System Interfaces Functional interfaces include the primary containment heating and ventilation system (VII.F3),
containment isolation components (V.C), and the standby gas treatment system (V.B). Physical interfaces exist with any structure, system, or component that either penetrates the containment wall, such as the main steam (MS) system (VIII.B2) and the feedwater (FW) system (VIII.D2), or is supported by the containment structure. The containment structure basemat may provide support to the nuclear steam supply system components and containment internal structures.
II B1-2 II CONTAINMENT STRUCTURES Table B1.1 Mark I Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B1.1.CP-43 3.5-1, 035 Steel elements (accessible areas):
drywell shell; drywell head; drywell shell in sand pocket regions Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes E
II.B1.1.C-23 3.5-1, 036 Steel elements:
drywell head; downcomers Steel Air - indoor uncontrolled Loss of material due to mechanical wear, including fretting AMP XI.S1, "ASME Section XI, Subsection IWE" No II.B1.1.CP-44 3.5-1, 041 Steel elements:
drywell support skirt Steel Concrete None None No E
II.B1.1.CP-109 3.5-1, 007 Steel elements:
torus ring girders; downcomers; Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE" Yes M
II.B1.1.CP-48 3.5-1, 006 Steel elements:
torus shell Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II B1-3 II CONTAINMENT STRUCTURES Table B1.1 Mark I Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.B1.1.CP-49 3.5-1, 027 Steel elements:
torus; vent line; vent header; vent line bellows; downcomers Steel; stainless steel Air - indoor uncontrolled Cracking due to cyclic loading (CLB fatigue analysis does not exist)
AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" No E
II.B1.1.C-21 3.5-1, 009 Steel elements:
torus; vent line; vent header; vent line bellows; downcomers Steel; stainless steel Air - indoor uncontrolled Cumulative fatigue damage due to fatigue (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.6, "Containment Liner Plate and Penetration Fatigue Analysis" Yes M
II.B1.1.CP-50 3.5-1, 039 Steel elements:
vent line bellows Stainless steel Air - indoor uncontrolled Cracking due to SCC AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II B1-4 II CONTAINMENT STRUCTURES Table B1.2 Mark I Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B1.2.CP-79 3.5-1, 021 Concrete (accessible areas):
basemat; reinforcing steel Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL" No E
II.B1.2.CP-59 3.5-1, 019 Concrete (accessible areas):
containment; wall; basemat Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S2, "ASME Section XI, Subsection IWL" No II.B1.2.CP-54 3.5-1, 020 Concrete (accessible areas):
containment; wall; basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S2, "ASME Section XI, Subsection IWL" No M
II.B1.2.CP-80 3.5-1, 023 Concrete (inaccessible areas): basemat; reinforcing steel Concrete Any Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL,"
and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No
II B1-5 II CONTAINMENT STRUCTURES Table B1.2 Mark I Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B1.2.CP-99 3.5-1, 012 Concrete (inaccessible areas):
containment; wall; basemat Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.B1.2.CP-110 3.5-1, 014 Concrete (inaccessible areas):
containment; wall; basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
II B1-6 II CONTAINMENT STRUCTURES Table B1.2 Mark I Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B1.2.CP-105 3.5-1, 001 Concrete elements: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S2, "ASME Section XI, Subsection IWL,"
and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" Yes E
II.B1.2.CP-57 3.5-1, 003 Concrete:
containment; wall; basemat Concrete Air - indoor uncontrolled, air -
outdoor Reduction of strength and modulus due to elevated temperature (>150°F general; >200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.B1.2.CP-106 3.5-1, 016 Concrete:
containment; wall; basemat Concrete Air - indoor uncontrolled, air -
- outdoor, groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL,"
or AMP XI.S6, "Structures Monitoring" No
II B1-7 II CONTAINMENT STRUCTURES Table B1.2 Mark I Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B1.2.C-07 3.5-1, 002 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes M
II.B1.2.CP-46 3.5-1, 035 Steel elements (accessible areas):
suppression chamber; drywell; drywell head; embedded shell; region shielded by diaphragm floor (as applicable)
Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes II.B1.2.CP-114 3.5-1, 041 Steel elements (inaccessible areas): support skirt Steel Concrete None None No
II B1-8 II CONTAINMENT STRUCTURES Table B1.2 Mark I Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B1.2.CP-63 3.5-1, 005 Steel elements (inaccessible areas):
suppression chamber; drywell; drywell head; embedded shell; region shielded by diaphragm floor (as applicable)
Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes II.B1.2.CP-117 3.5-1, 031 Steel elements:
downcomer pipes Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE" No E
II.B1.2.C-23 3.5-1, 036 Steel elements:
drywell head; downcomers Steel Air - indoor uncontrolled Loss of material due to mechanical wear, including fretting AMP XI.S1, "ASME Section XI, Subsection IWE" No II.B1.2.C-49 3.5-1, 037 Steel elements:
suppression chamber (torus) liner (interior surface)
Steel; stainless steel Air - indoor uncontrolled, treated water Loss of material due to general (steel only), pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" No
II B2-1 B2 MARK II CONTAINMENTS Systems, Structures, and Components This section addresses the elements of boiling water reactor (BWR) Mark II containment structures. Mark II steel containments are discussed in II.B2.1. Mark II concrete containments are discussed in II.B2.2.
System Interfaces Functional interfaces include the primary containment heating and ventilation system (VII.F3),
containment isolation components (V.C), and the standby gas treatment system (V.B). Physical interfaces exist with any structure, system, or component that either penetrates the containment wall, such as the main steam (MS) system (VIII.B2) and the feedwater (FW) system (VIII.D2), or is supported by the containment structure. The containment structure basemat may provide support to the nuclear steam supply system components and containment internal structures.
II B2-2 II CONTAINMENT STRUCTURES Table B2.1 Mark II Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B2.1.CP-46 3.5-1, 035 Steel elements (accessible areas):
suppression chamber; drywell; drywell head; embedded shell; region shielded by diaphragm floor (as applicable)
Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes II.B2.1.CP-114 3.5-1, 041 Steel elements (inaccessible areas): support skirt Steel Concrete None None No E
II.B2.1.CP-63 3.5-1, 005 Steel elements (inaccessible areas): suppression chamber; drywell; drywell head; embedded shell; region shielded by diaphragm floor (as applicable)
Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes II.B2.1.CP-117 3.5-1, 031 Steel elements:
downcomer pipes Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE" No
II B2-3 II CONTAINMENT STRUCTURES Table B2.1 Mark II Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B2.1.C-23 3.5-1, 036 Steel elements:
drywell head; downcomers Steel Air - indoor uncontrolled Loss of material due to mechanical wear, including fretting AMP XI.S1, "ASME Section XI, Subsection IWE" No II.B2.1.CP-107 3.5-1, 027 Suppression pool shell Steel; stainless steel; dissimilar metal welds Air - indoor uncontrolled, treated water Cracking due to cyclic loading (CLB fatigue analysis does not exist)
AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" No M
II.B2.1.C-45 3.5-1, 009 Suppression pool shell; unbraced downcomers Steel; stainless steel; dissimilar metal welds Air - indoor uncontrolled, treated water Cumulative fatigue damage due to fatigue (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.6, "Containment Liner Plate and Penetration Fatigue Analysis" Yes II.B2.1.CP-142 3.5-1, 040 Unbraced downcomers Steel; stainless steel; dissimilar metal welds Air - indoor uncontrolled, treated water Cracking due to cyclic loading (CLB fatigue analysis does not exist)
AMP XI.S1, "ASME Section XI, Subsection IWE" No
II B2-4 II CONTAINMENT STRUCTURES Table B2.2 Mark II Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B2.2.CP-79 3.5-1, 021 Concrete (accessible areas):
basemat; reinforcing steel Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL" No E
II.B2.2.CP-59 3.5-1, 019 Concrete (accessible areas):
containment; wall; basemat Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S2, "ASME Section XI, Subsection IWL" No II.B2.2.CP-54 3.5-1, 020 Concrete (accessible areas):
containment; wall; basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S2, "ASME Section XI, Subsection IWL" No M
II.B2.2.CP-80 3.5-1, 023 Concrete (inaccessible areas):
basemat; reinforcing steel Concrete Any Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL,"
and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No
II B2-5 II CONTAINMENT STRUCTURES Table B2.2 Mark II Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B2.2.CP-99 3.5-1, 012 Concrete (inaccessible areas):
containment; wall; basemat Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.B2.2.CP-110 3.5-1, 014 Concrete (inaccessible areas):
containment; wall; basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
II.B2.2.CP-105 3.5-1, 001 Concrete elements: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S2, "ASME Section XI, Subsection IWL,"
and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" Yes
II B2-6 II CONTAINMENT STRUCTURES Table B2.2 Mark II Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B2.2.CP-57 3.5-1, 003 Concrete:
containment; wall; basemat Concrete Air - indoor uncontrolled, air -
outdoor Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.B2.2.CP-106 3.5-1, 016 Concrete:
containment; wall; basemat Concrete Air - indoor uncontrolled, air -
- outdoor, groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL,"
and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No E
II.B2.2.C-07 3.5-1, 002 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes
II B2-7 II CONTAINMENT STRUCTURES Table B2.2 Mark II Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B2.2.C-11 3.5-1, 008 Prestressing system:
tendons Steel Air - indoor uncontrolled, air -
outdoor Loss of prestress due to relaxation; shrinkage; creep; elevated temperature TLAA, SRP-SLR Section 4.5, "Concrete Containment Tendon Prestress,"
and/or SRP-SLR Section 4.7, "Other Plant-Specific Time-Limited Aging Analyses" Yes II.B2.2.C-10 3.5-1, 032 Prestressing system:
tendons; anchorage components Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to corrosion AMP XI.S2, "ASME Section XI, Subsection IWL" No M
II.B2.2.CP-46 3.5-1, 035 Steel elements (accessible areas):
suppression chamber; drywell; drywell head; embedded shell; region shielded by diaphragm floor (as applicable)
Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II B2-8 II CONTAINMENT STRUCTURES Table B2.2 Mark II Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.B2.2.CP-114 3.5-1, 041 Steel elements (inaccessible areas): support skirt Steel Concrete None None No E
II.B2.2.CP-63 3.5-1, 005 Steel elements (inaccessible areas):
suppression chamber; drywell; drywell head; embedded shell; region shielded by diaphragm floor (as applicable)
Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes II.B2.2.CP-117 3.5-1, 031 Steel elements:
downcomer pipes Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE" No E
II.B2.2.C-23 3.5-1, 036 Steel elements:
drywell head; downcomers Steel Air - indoor uncontrolled Loss of material due to mechanical wear, including fretting AMP XI.S1, "ASME Section XI, Subsection IWE" No II.B2.2.C-49 3.5-1, 037 Steel elements:
suppression chamber (torus) liner (interior surface)
Steel; stainless steel Air - indoor uncontrolled, treated water Loss of material due to general (steel only), pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE,"
and AMP XI.S4, "10 CFR Part 50, Appendix J" No
II B2-9 II CONTAINMENT STRUCTURES Table B2.2 Mark II Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.B2.2.CP-64 3.5-1, 040 Steel elements:
vent header; downcomers Steel; stainless steel Air - indoor uncontrolled, treated water Cracking due to cyclic loading (CLB fatigue analysis does not exist)
AMP XI.S1, "ASME Section XI, Subsection IWE" No E
II.B2.2.C-48 3.5-1, 009 Steel elements:
vent header; downcomers Steel; stainless steel Air - indoor uncontrolled, treated water Cumulative fatigue damage due to fatigue (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.6, "Containment Liner Plate and Penetration Fatigue Analysis" Yes
II B3 II MARK III CONTAINMENTS B3.1 STEEL CONTAINMENTS B3.2 CONCRETE CONTAINMENTS
II B3-1 B3.
MARK III CONTAINMENTS Systems, Structures, and Components This section addresses the elements of boiling water reactor (BWR) Mark III containment structures. Mark III steel containments are discussed in II.B3.1. Mark III concrete containments are discussed in II.B3.2.
System Interfaces Functional interfaces include the primary containment heating and ventilation system (VII.F3),
containment isolation components (V.C), and the standby gas treatment system (V.B). Physical interfaces exist with any structure, system, or component that either penetrates the containment wall, such as the main steam (MS) system (VIII.B2) and the feedwater (FW) system (VIII.D2), or is supported by the containment structure. The containment structure basemat may provide support to the nuclear steam supply system components and containment internal structures.
II B3-2 II CONTAINMENT STRUCTURES Table B3.1 Mark III Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.B3.1.CP-72 3.5-1, 016 Concrete (accessible areas):
basemat Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No II.B3.1.CP-156 3.5-1, 020 Concrete (accessible areas):
basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No E
II.B3.1.CP-66 3.5-1, 019 Concrete (accessible areas):
- basemat, concrete fill-in annulus Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No
II B3-3 II CONTAINMENT STRUCTURES Table B3.1 Mark III Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B3.1.CP-74 3.5-1, 021 Concrete (accessible areas):
basemat; reinforcing steel Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No II.B3.1.CP-71 3.5-1, 024 Concrete (inaccessible areas):
basemat Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No M
II.B3.1.CP-53 3.5-1, 014 Concrete (inaccessible areas):
basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring, "
enhanced as necessary Yes
II B3-4 II CONTAINMENT STRUCTURES Table B3.1 Mark III Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B3.1.CP-83 3.5-1, 012 Concrete (inaccessible areas):
- basemat, concrete fill-in annulus Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes M
II.B3.1.CP-75 3.5-1, 023 Concrete (inaccessible areas):
basemat; reinforcing steel Concrete Any Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" No E
II.B3.1.CP-69 3.5-1, 001 Concrete:
basemat Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S2, "ASME Section XI, Subsection IWL," or AMP XI.S6, "Structures Monitoring" Yes
II B3-5 II CONTAINMENT STRUCTURES Table B3.1 Mark III Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B3.1.CP-65 3.5-1, 003 Concrete:
- basemat, concrete fill-in annulus Concrete Air - indoor uncontrolled, air -
outdoor Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
II.B3.1.C-07 3.5-1, 002 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes M
II.B3.1.CP-43 3.5-1, 035 Steel elements (accessible areas): drywell shell; drywell head Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II B3-6 II CONTAINMENT STRUCTURES Table B3.1 Mark III Steel Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B3.1.CP-113 3.5-1, 004 Steel elements (inaccessible areas): drywell shell; drywell head Steel Air - indoor uncontrolled, concrete Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes M
II.B3.1.C-24 3.5-1, 038 Steel elements:
suppression chamber shell (interior surface)
Stainless steel Air - indoor uncontrolled Cracking due to SCC AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes E
II.B3.1.CP-158 3.5-1, 007 Steel elements:
suppression chamber shell (interior surface)
Steel Air - indoor uncontrolled, treated water Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE" Yes
II B3-7 II CONTAINMENT STRUCTURES Table B3.2 Mark III Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.B3.2.CP-84 3.5-1, 024 Concrete (accessible areas): dome; wall; basemat Concrete Air - indoor uncontrolled, air
- outdoor, groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL," and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No II.B3.2.CP-52 3.5-1, 018 Concrete (accessible areas): dome; wall; basemat Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S2, "ASME Section XI, Subsection IWL" No E
II.B3.2.CP-60 3.5-1, 019 Concrete (accessible areas): dome; wall; basemat Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S2, "ASME Section XI, Subsection IWL" No II.B3.2.CP-55 3.5-1, 020 Concrete (accessible areas): dome; wall; basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S2, "ASME Section XI, Subsection IWL" No M
II.B3.2.CP-88 3.5-1, 021 Concrete (accessible areas): dome; wall; basemat; reinforcing steel Concrete Air - indoor uncontrolled, air
- outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL" No
II B3-8 II CONTAINMENT STRUCTURES Table B3.2 Mark III Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation II.B3.2.CP-73 3.5-1, 024 Concrete (inaccessible areas): dome; wall; basemat Concrete Air - indoor uncontrolled, air
- outdoor, groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S2, "ASME Section XI, Subsection IWL," and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No E
II.B3.2.CP-135 3.5-1, 011 Concrete (inaccessible areas): dome; wall; basemat Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes
II B3-9 II CONTAINMENT STRUCTURES Table B3.2 Mark III Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B3.2.CP-121 3.5-1, 012 Concrete (inaccessible areas): dome; wall; basemat Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program significant if it is demonstrated that the in-place concrete can perform its intended function, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring," enhanced as necessary.
Yes M
II.B3.2.CP-122 3.5-1, 014 Concrete (inaccessible areas): dome; wall; basemat Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S2, "ASME Section XI, Subsection IWL," and/or AMP XI.S6, "Structures Monitoring", enhanced as necessary Yes M
II.B3.2.CP-89 3.5-1, 023 Concrete (inaccessible areas): dome; wall; basemat; reinforcing steel Concrete Any Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S2, "ASME Section XI, Subsection IWL," and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" No
II B3-10 II CONTAINMENT STRUCTURES Table B3.2 Mark III Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
II.B3.2.CP-105 3.5-1, 001 Concrete elements: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S2, "ASME Section XI, Subsection IWL," and supplemented, as necessary, by AMP XI.S6, "Structures Monitoring" Yes E
II.B3.2.CP-108 3.5-1, 003 Concrete:
dome; wall; basemat Concrete Air - indoor uncontrolled, air
- outdoor Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S2, "ASME Section XI, Subsection IWL,"
and/or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes E
II.B3.2.C-07 3.5-1, 002 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes
II B3-11 II CONTAINMENT STRUCTURES Table B3.2 Mark III Concrete Containments
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B3.2.CP-35 3.5-1, 035 Steel elements (accessible areas): liner; liner anchors; integral attachments Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes E
II.B3.2.CP-98 3.5-1, 005 Steel elements (inaccessible areas): liner; liner anchors; integral attachments Steel Air - indoor uncontrolled Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes M
II.B3.2.C-24 3.5-1, 038 Steel elements:
suppression chamber shell (interior surface)
Stainless steel Air - indoor uncontrolled Cracking due to SCC AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes
II B4-1 B4.
COMMON COMPONENTS Systems, Structures, and Components This section addresses the common components of boiling water reactor (BWR) containments.
The common components include (i) penetration sleeves and bellows, (ii) dissimilar metal welds, (iii) personnel airlock, (iv) equipment hatch, (v) control rod drive (CRD) and hatch, (vi) seals, (vii) gaskets, and (viii) moisture barriers.
System Interfaces Functional interfaces include the primary containment heating and ventilation system (VII.F3),
containment isolation components (V.C), and standby gas treatment system (V.B). Physical interfaces exist with any structure, system, or component that either penetrates the containment wall, such as the main steam (MS) system (VIII.B2) and the feedwater (FW) system (VIII.D2), or is supported by the containment structure. The containment structure basemat may provide support to the nuclear steam supply system components and containment internal structures.
II B4-2 II CONTAINMENT STRUCTURES Table B4 Common Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B4.CP-37 3.5-1, 027 Metal liner, metal plate,
- airlock, equipment hatch, CRD hatch; penetration sleeves; penetration bellows Steel; stainless steel; dissimilar metal welds Air - indoor uncontrolled, air
- outdoor Cracking due to cyclic loading (CLB fatigue analysis does not exist)
AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No M
II.B4.C-13 3.5-1, 009 Metal liner, metal plate, personnel
- airlock, equipment hatch, CRD
- hatch, penetration sleeves; penetration bellows Steel; stainless steel; dissimilar metal welds Air - indoor uncontrolled, air
- outdoor Cumulative fatigue damage due to fatigue (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.6, "Containment Liner Plate and Penetration Fatigue Analysis" Yes II.B4.CP-40 3.5-1, 026 Moisture barriers (caulking, flashing, other sealants)
Elastomer, rubber and other similar materials Air - indoor uncontrolled Loss of sealing due to wear, damage, erosion, tear, surface cracks, other defects AMP XI.S1, "ASME Section XI, Subsection IWE" No
II B4-3 II CONTAINMENT STRUCTURES Table B4 Common Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B4.CP-36 3.5-1, 035 Penetration sleeves Steel; dissimilar metal welds Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes E
II.B4.CP-38 3.5-1, 010 Penetration sleeves; penetration bellows Stainless steel; dissimilar metal welds Air - indoor uncontrolled, air
- outdoor Cracking due to SCC AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" Yes II.B4.C-16 3.5-1, 028 Personnel
- airlock, equipment hatch, CRD hatch Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No M
II.B4.CP-39 3.5-1, 029 Personnel
- airlock, equipment hatch, CRD hatch: locks, hinges, closure mechanisms Steel Air - indoor uncontrolled, air
- outdoor Loss of leak tightness due to mechanical wear AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No II.B4.CP-148 3.5-1, 031 Pressure-retaining bolting Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S1, "ASME Section XI, Subsection IWE" No
II B4-4 II CONTAINMENT STRUCTURES Table B4 Common Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
II.B4.CP-150 3.5-1, 030 Pressure-retaining bolting Steel Any Loss of preload due to self-loosening AMP XI.S1, "ASME Section XI, Subsection IWE," and AMP XI.S4, "10 CFR Part 50, Appendix J" No II.B4.CP-41 3.5-1, 033 Seals and gaskets Elastomer, rubber and other similar materials Air - indoor uncontrolled, air
- outdoor Loss of sealing due to wear, damage, erosion, tear, surface cracks, other defects AMP XI.S4, "10 CFR Part 50, Appendix J" No M
II.B4.CP-152 3.5-1, 034 Service Level I coatings Coatings Air - indoor uncontrolled, treated water Loss of coating or lining integrity due to blistering, cracking, flaking, peeling, delamination, rusting, physical damage AMP XI.S8, "Protective Coating Monitoring and Maintenance" No
CHAPTER III STRUCTURES AND COMPONENT SUPPORTS
III-1 III STRUCTURES AND COMPONENT SUPPORTS III A.
SAFETY-RELATED AND OTHER STRUCTURES Safety-related structures are those defined pursuant to Title 10 of the Code of Federal Regulations (10 CFR) 54.4(a)(1), and the other structures are those defined pursuant to 10 CFR 54.4(a)(2) and 10 CFR 54.4(a)(3). Structures in this section are organized into nine groups and are discussed separately under subheadings A1 through A9.
III B.
COMPONENT SUPPORTS Component supports include supports for American Society of Mechanical Engineers (ASME) piping and components; supports for cable trays, conduit, heating, ventilation, and air conditioning (HVAC) ducts, TubeTrack, instrument tubing, non-ASME piping and components; anchorage of racks, panels, cabinets, and enclosures for electrical equipment and instrumentation; supports for emergency diesel generator (EDG) and HVAC system components; and supports for platforms, pipe whip restraints, jet impingement shields, masonry walls, and other miscellaneous structures.
III-3 III SAFETY-RELATED AND OTHER STRUCTURES A1.
GROUP 1 STRUCTURES (BWR REACTOR BLDG., PWR SHIELD BLDG., CONTROL ROOM/BLDG.)
A2.
GROUP 2 STRUCTURES (BWR REACTOR BLDG. WITH STEEL SUPERSTRUCTURE)
A3.
GROUP 3 STRUCTURES (AUXILIARY BLDG., DIESEL GENERATOR BLDG.,
RADWASTE BLDG., TURBINE BLDG., SWITCHGEAR ROOM, YARD STRUCTURES SUCH AS AFW PUMPHOUSE, UTILITY/PIPING TUNNELS, SECURITY/LIGHTING POLES, MANHOLES, DUCT BANKS; SBO STRUCTURES, SUCH AS TRANSMISSION TOWERS, STARTUP TOWERS CIRCUIT BREAKER FOUNDATION, ELECTRICAL ENCLOSURE)
A4.
GROUP 4 STRUCTURES (CONTAINMENT INTERNAL STRUCTURES, EXCLUDING REFUELING CANAL)
A5.
GROUP 5 STRUCTURES (FUEL STORAGE FACILITY, REFUELING CANAL)
A6.
GROUP 6 STRUCTURES (WATER-CONTROL STRUCTURES)
A7.
GROUP 7 STRUCTURES (CONCRETE TANKS AND MISSILE BARRIERS)
A8.
GROUP 8 STRUCTURES (STEEL TANKS AND MISSILE BARRIERS)
A9.
GROUP 9 STRUCTURES (BWR UNIT VENT STACK)
III A1-1 A1.
GROUP 1 STRUCTURES (BOILING WATER REACTOR BUILDING, PRESSURIZED WATER REACTOR SHIELD BUILDING, CONTROL ROOM/BUILDING)
Systems, Structures, and Components This section addresses the elements of the boiling water reactor (BWR) reactor building, pressurized water reactor (PWR) shield building, and control room/building. For this group, the applicable structural elements are concrete, steel, and masonry walls. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed systems or components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A1-2 III STRUCTURES AND COMPONENT SUPPORTS Table A1 Group 1 Structures (BWR Reactor Bldg., PWR Shield Bldg., Control Room/Bldg.)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A1.TP-25 3.5-1, 054 Concrete (accessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A1.TP-27 3.5-1, 065 Concrete (accessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A1.TP-23 3.5-1, 064 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S6, "Structures Monitoring" No III.A1.TP-24 3.5-1, 063 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S6, "Structures Monitoring" No III.A1.TP-26 3.5-1, 066 Concrete (accessible areas): interior and above-grade exterior Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No
III A1-3 III STRUCTURES AND COMPONENT SUPPORTS Table A1 Group 1 Structures (BWR Reactor Bldg., PWR Shield Bldg., Control Room/Bldg.)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A1.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes III.A1.TP-212 3.5-1, 065 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A1.TP-29 3.5-1, 067 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No M
III.A1.TP-67 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
III A1-4 III STRUCTURES AND COMPONENT SUPPORTS Table A1 Group 1 Structures (BWR Reactor Bldg., PWR Shield Bldg., Control Room/Bldg.)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A1.TP-108 3.5-1, 042 Concrete (inaccessible areas):
foundation Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A1.TP-114 3.5-1, 048 Concrete: all Concrete Air - indoor uncontrolled Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S6, Structures Monitoring, enhanced as necessary Yes E
III.A1.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes
III A1-5 III STRUCTURES AND COMPONENT SUPPORTS Table A1 Group 1 Structures (BWR Reactor Bldg., PWR Shield Bldg., Control Room/Bldg.)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A1.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes III.A1.TP-28 3.5-1, 067 Concrete:
interior; above-grade exterior Concrete Air - indoor uncontrolled, air -
outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No III.A1.T-12 3.5-1, 070 Masonry walls:
all Concrete block Air - indoor uncontrolled, air -
outdoor Cracking due to restraint shrinkage, creep, and aggressive environment AMP XI.S5, "Masonry Walls" No N
III.A1.TP-34 3.5-1, 071 Masonry walls:
all Concrete block Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S5, "Masonry Walls" No E
III.A1.TP-302 3.5-1, 077 Steel components: all structural steel Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No
III A1-6 III STRUCTURES AND COMPONENT SUPPORTS Table A1 Group 1 Structures (BWR Reactor Bldg., PWR Shield Bldg., Control Room/Bldg.)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A1.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A1.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A1.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A1.TP-300
III A2-1 A2.
GROUP 2 STRUCTURES (BOILING WATER REACTOR BUILDING WITH STEEL SUPERSTRUCTURE)
Systems, Structures, and Components This section addresses the elements of the boiling water reactor (BWR) reactor building with steel superstructure. For this group, the applicable structural elements are identified: (i) concrete, (ii) steel, and (iii) masonry walls. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed systems and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A2-2 III STRUCTURES AND COMPONENT SUPPORTS Table A2 Group 2 Structures (BWR Reactor Bldg. With Steel Superstructure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A2.TP-25 3.5-1, 054 Concrete (accessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A2.TP-27 3.5-1, 065 Concrete (accessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A2.TP-23 3.5-1, 064 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S6, "Structures Monitoring" No III.A2.TP-24 3.5-1, 063 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S6, "Structures Monitoring" No III.A2.TP-26 3.5-1, 066 Concrete (accessible areas): interior and above-grade exterior Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No
III A2-3 III STRUCTURES AND COMPONENT SUPPORTS Table A2 Group 2 Structures (BWR Reactor Bldg. With Steel Superstructure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A2.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes III.A2.TP-212 3.5-1, 065 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A2.TP-29 3.5-1, 067 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No M
III.A2.TP-67 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
III A2-4 III STRUCTURES AND COMPONENT SUPPORTS Table A2 Group 2 Structures (BWR Reactor Bldg. With Steel Superstructure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A2.TP-108 3.5-1, 042 Concrete (inaccessible areas):
foundation Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A2.TP-114 3.5-1, 048 Concrete: all Concrete Air - indoor uncontrolled Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A2.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes
III A2-5 III STRUCTURES AND COMPONENT SUPPORTS Table A2 Group 2 Structures (BWR Reactor Bldg. With Steel Superstructure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A2.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes III.A2.TP-28 3.5-1, 067 Concrete:
interior; above-grade exterior Concrete Air - indoor uncontrolled, air -
outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No III.A2.T-12 3.5-1, 070 Masonry walls:
all Concrete block Air - indoor uncontrolled, air -
outdoor Cracking due to restraint shrinkage, creep, and aggressive environment AMP XI.S5, "Masonry Walls" No N
III.A2.TP-34 3.5-1, 071 Masonry walls:
all Concrete block Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S5, "Masonry Walls" No E
III.A2.TP-302 3.5-1, 077 Steel components: all structural steel Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No
III A2-6 III STRUCTURES AND COMPONENT SUPPORTS Table A2 Group 2 Structures (BWR Reactor Bldg. With Steel Superstructure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A2.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A2.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A2.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A2.TP-300
III A3-1 A3.
GROUP 3 STRUCTURES (AUXILIARY BUILDING, DIESEL GENERATOR BUILDING, RADWASTE BUILDING, TURBINE BUILDING, SWITCHGEAR ROOM, YARD STRUCTURES, SUCH AS AUXILIARY FEEDWATER PUMPHOUSE, UTILITY/PIPING TUNNELS, SECURITY/LIGHTING POLES, MANHOLES, DUCT BANKS; STATION BLACKOUT STRUCTURES, SUCH AS TRANSMISSION TOWERS, STARTUP TOWERS CIRCUIT BREAKER FOUNDATION, ELECTRICAL ENCLOSURE)
Systems, Structures, and Components This section addresses the elements of the auxiliary building, diesel generator building, radwaste building, turbine building, switchgear room, yard structures, and station blackout (SBO) structures.
For this group, the applicable structural elements are identified: (i) concrete, (ii) steel, and (iii) masonry walls. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed structures and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A3-2 III STRUCTURES AND COMPONENT SUPPORTS Table A3 Group 3 Structures (Auxiliary Bldg., Diesel Generator Bldg., Radwaste Bldg., Turbine Bldg., Switchgear Rm., Yard Structures Such As AFW Pumphouse, Utility/Piping Tunnels, Security/Lighting Poles, Manholes, Duct Banks; SBO Structures Such As Transmission Towers, Startup Tower Circuit Breaker Foundation, Electrical Enclosure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A3.TP-25 3.5-1, 054 Concrete (accessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A3.TP-27 3.5-1, 065 Concrete (accessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A3.TP-23 3.5-1, 064 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S6, "Structures Monitoring" No III.A3.TP-24 3.5-1, 063 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S6, "Structures Monitoring" No
III A3-3 III STRUCTURES AND COMPONENT SUPPORTS Table A3 Group 3 Structures (Auxiliary Bldg., Diesel Generator Bldg., Radwaste Bldg., Turbine Bldg., Switchgear Rm., Yard Structures Such As AFW Pumphouse, Utility/Piping Tunnels, Security/Lighting Poles, Manholes, Duct Banks; SBO Structures Such As Transmission Towers, Startup Tower Circuit Breaker Foundation, Electrical Enclosure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.A3.TP-26 3.5-1, 066 Concrete (accessible areas): interior and above-grade exterior Concrete Air - indoor uncontrolled, air -
outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No M
III.A3.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes III.A3.TP-212 3.5-1, 065 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A3.TP-29 3.5-1, 067 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No
III A3-4 III STRUCTURES AND COMPONENT SUPPORTS Table A3 Group 3 Structures (Auxiliary Bldg., Diesel Generator Bldg., Radwaste Bldg., Turbine Bldg., Switchgear Rm., Yard Structures Such As AFW Pumphouse, Utility/Piping Tunnels, Security/Lighting Poles, Manholes, Duct Banks; SBO Structures Such As Transmission Towers, Startup Tower Circuit Breaker Foundation, Electrical Enclosure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A3.TP-67 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes M
III.A3.TP-108 3.5-1, 042 Concrete (inaccessible areas):
foundation Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes E
III.A3.TP-114 3.5-1, 048 Concrete: all Concrete Air - indoor uncontrolled Reduction of strength and modulus due to elevated temperature (>150°F general; >200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes
III A3-5 III STRUCTURES AND COMPONENT SUPPORTS Table A3 Group 3 Structures (Auxiliary Bldg., Diesel Generator Bldg., Radwaste Bldg., Turbine Bldg., Switchgear Rm., Yard Structures Such As AFW Pumphouse, Utility/Piping Tunnels, Security/Lighting Poles, Manholes, Duct Banks; SBO Structures Such As Transmission Towers, Startup Tower Circuit Breaker Foundation, Electrical Enclosure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A3.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes E
III.A3.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes III.A3.TP-28 3.5-1, 067 Concrete:
interior; above-grade exterior Concrete Air - indoor uncontrolled, air -
outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No III.A3.T-12 3.5-1, 070 Masonry walls:
all Concrete block Air - indoor uncontrolled, air -
outdoor Cracking due to restraint shrinkage, creep, and aggressive environment AMP XI.S5, "Masonry Walls" No
III A3-6 III STRUCTURES AND COMPONENT SUPPORTS Table A3 Group 3 Structures (Auxiliary Bldg., Diesel Generator Bldg., Radwaste Bldg., Turbine Bldg., Switchgear Rm., Yard Structures Such As AFW Pumphouse, Utility/Piping Tunnels, Security/Lighting Poles, Manholes, Duct Banks; SBO Structures Such As Transmission Towers, Startup Tower Circuit Breaker Foundation, Electrical Enclosure)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.A3.TP-34 3.5-1, 071 Masonry walls:
all Concrete block Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S5, "Masonry Walls" No E
III.A3.TP-302 3.5-1, 077 Steel components:
all structural steel Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No III.A3.TP-219 3.5-1, 079 Steel components:
piles Steel Soil, groundwater Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No E
III.A3.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A3.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air -
outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A3.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A3.TP-300
III A4-1 A4.
GROUP 4 STRUCTURES (CONTAINMENT INTERNAL STRUCTURES, EXCLUDING REFUELING CANAL)
Systems, Structures, and Components This section addresses the elements of the containment internal structures, excluding refueling canal. For this group, the applicable structural elements are identified: (i) concrete and (ii) steel elements. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed systems and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A4-2 III STRUCTURES AND COMPONENT SUPPORTS Table A4 Group Structures (Containment Internal Structures, Excluding Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A4.TP-25 3.5-1, 054 Concrete (accessible areas):
all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A4.TP-26 3.5-1, 066 Concrete (accessible areas):
interior and above-grade exterior Concrete Air - indoor uncontrolled, air - outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No M
III.A4.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes M
III.A4.TP-305 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water -
flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes
III A4-3 III STRUCTURES AND COMPONENT SUPPORTS Table A4 Group Structures (Containment Internal Structures, Excluding Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A4.TP-114 3.5-1, 048 Concrete: all Concrete Air - indoor uncontrolled Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S6, "Structures Monitoring," enhanced as necessary Yes E
III.A4.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes III.A4.TP-28 3.5-1, 067 Concrete: interior; above-grade exterior Concrete Air - indoor uncontrolled, air - outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No
III A4-4 III STRUCTURES AND COMPONENT SUPPORTS Table A4 Group Structures (Containment Internal Structures, Excluding Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.A4.T-35 3.5-1, 097 Group 4: Concrete (reactor cavity area proximate to the reactor vessel):
reactor (primary/biological) shield wall; sacrificial shield wall; reactor vessel support/pedestal structure Concrete Air - indoor uncontrolled Reduction of strength; loss of mechanical properties due to irradiation (i.e.,
radiation interactions with material and radiation-induced heating)
Plant-specific aging management program or other selected AMPs, enhanced as necessary Yes M
III.A4.TP-301 3.5-1, 073 Service Level I coatings Coatings Air - indoor uncontrolled, treated water Loss of coating or lining integrity due to blistering, cracking, flaking, peeling, delamination, rusting, physical damage AMP XI.S8, "Protective Coating Monitoring and Maintenance" No M
III.A4.TP-35 3.5-1, 076 Sliding surfaces:
radial beam seats in BWR drywell Lubrite; Fluorogold; Lubrofluor Air - indoor uncontrolled Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S6, "Structures Monitoring" No E
III.A4.TP-302 3.5-1, 077 Steel components:
all structural steel Steel Air - indoor uncontrolled, air - outdoor Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No E
III.A4.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No
III A4-5 III STRUCTURES AND COMPONENT SUPPORTS Table A4 Group Structures (Containment Internal Structures, Excluding Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A4.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A4.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A4.TP-300
III A5-1 A5.
GROUP 5 STRUCTURES (FUEL STORAGE FACILITY, REFUELING CANAL)
Systems, Structures, and Components This section addresses the elements of the fuel storage facility and refueling canal. For this group, the applicable structural elements are identified: (i) concrete, (ii) steel, and (iii) masonry walls. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed structures and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A5-2 III STRUCTURES AND COMPONENT SUPPORTS Table A5 Group 5 Structures (Fuel Storage Facility, Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A5.TP-25 3.5-1, 054 Concrete (accessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A5.TP-27 3.5-1, 065 Concrete (accessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A5.TP-23 3.5-1, 064 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S6, "Structures Monitoring" No III.A5.TP-24 3.5-1, 063 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S6, "Structures Monitoring" No III.A5.TP-26 3.5-1, 066 Concrete (accessible areas): interior and above-grade exterior Concrete Air - indoor uncontrolled, air
- outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No
III A5-3 III STRUCTURES AND COMPONENT SUPPORTS Table A5 Group 5 Structures (Fuel Storage Facility, Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A5.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes III.A5.TP-212 3.5-1, 065 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A5.TP-29 3.5-1, 067 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No M
III.A5.TP-67 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
III A5-4 III STRUCTURES AND COMPONENT SUPPORTS Table A5 Group 5 Structures (Fuel Storage Facility, Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A5.TP-108 3.5-1, 042 Concrete (inaccessible areas):
foundation Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A5.TP-114 3.5-1, 048 Concrete: all Concrete Air - indoor uncontrolled Reduction of strength and modulus due to elevated temperature
(>150°F general;
>200°F local)
Plant-specific aging management program to be evaluated if temperature limits exceeded, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A5.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes
III A5-5 III STRUCTURES AND COMPONENT SUPPORTS Table A5 Group 5 Structures (Fuel Storage Facility, Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A5.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes III.A5.TP-28 3.5-1, 067 Concrete:
interior; above-grade exterior Concrete Air - indoor uncontrolled, air
- outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No III.A5.T-12 3.5-1, 070 Masonry walls:
all Concrete block Air - indoor uncontrolled, air
- outdoor Cracking due to restraint shrinkage, creep, and aggressive environment AMP XI.S5, "Masonry Walls" No III.A5.TP-34 3.5-1, 071 Masonry walls:
all Concrete block Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S5, "Masonry Walls" No
III A5-6 III STRUCTURES AND COMPONENT SUPPORTS Table A5 Group 5 Structures (Fuel Storage Facility, Refueling Canal)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A5.T-14 3.5-1, 078 Stainless steel fuel pool liner Stainless steel Treated water, treated borated water Cracking due to SCC; loss of material due to pitting and crevice corrosion AMP XI.M2, "Water Chemistry,"
and monitoring of the spent fuel pool water level and leakage from the leak chase channels.
No E
III.A5.TP-302 3.5-1, 077 Steel components: all structural steel Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No E
III.A5.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A5.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A5.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A5.TP-300
III A6-1 A6.
GROUP 6 STRUCTURES (WATER-CONTROL STRUCTURES)
Systems, Structures, and Components This section addresses the elements of water-control structures. For this group, the applicable structural elements are identified: (i) concrete, (ii) steel, (iii) masonry walls, and (iv) earthen water-control structures (e.g., dams, embankments, reservoirs). The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed structures and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A6-2 III STRUCTURES AND COMPONENT SUPPORTS Table A6 Group 6 Structures (Water-Control Structures)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.A6.T-34 3.5-1, 096 Concrete (accessible areas):
all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" No N
III.A6.TP-25 3.5-1, 054 Concrete (accessible areas):
all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No E
III.A6.TP-38 3.5-1, 059 Concrete (accessible areas):
all Concrete Any Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" or the FERC / US Army Corp of Engineers dam inspections and maintenance programs.
No
III A6-3 III STRUCTURES AND COMPONENT SUPPORTS Table A6 Group 6 Structures (Water-Control Structures)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A6.TP-36 3.5-1, 060 Concrete (accessible areas):
exterior above-and below-grade; foundation Concrete Any Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" or the FERC / US Army Corp of Engineers dam inspections and maintenance programs.
No M
III.A6.TP-37 3.5-1, 061 Concrete (accessible areas):
exterior above-and below-grade; foundation; interior slab Concrete Any Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" or the FERC / US Army Corp of Engineers dam inspections and maintenance programs.
No III.A6.TP-104 3.5-1, 065 Concrete (inaccessible areas): all Concrete Air - indoor uncontrolled, air
- outdoor, groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No
III A6-4 III STRUCTURES AND COMPONENT SUPPORTS Table A6 Group 6 Structures (Water-Control Structures)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A6.TP-220 3.5-1, 050 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes III.A6.TP-107 3.5-1, 067 Concrete (inaccessible areas): all Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No M
III.A6.TP-110 3.5-1, 049 Concrete (inaccessible areas): exterior above-and below-grade; foundation; interior slab Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
III A6-5 III STRUCTURES AND COMPONENT SUPPORTS Table A6 Group 6 Structures (Water-Control Structures)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A6.TP-109 3.5-1, 051 Concrete (inaccessible areas): exterior above-and below-grade; foundation; interior slab Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A6.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes E
III.A6.T-20 3.5-1, 056 Concrete: exterior above-and below-grade; foundation; interior slab Concrete Water - flowing Loss of material due to abrasion; cavitation AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" or the FERC / US Army Corp of Engineers dam inspections and maintenance programs.
No
III A6-6 III STRUCTURES AND COMPONENT SUPPORTS Table A6 Group 6 Structures (Water-Control Structures)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A6.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes M
III.A6.T-22 3.5-1, 058 Earthen water-control structures:
dams; embankments; reservoirs; channels; canals; ponds Various Air - outdoor, water - flowing or standing Loss of material; loss of form due to erosion, settlement, sedimentation, frost action, waves, currents, surface runoff, seepage AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" or the FERC / US Army Corp of Engineers dam inspections and maintenance programs.
No
III A6-7 III STRUCTURES AND COMPONENT SUPPORTS Table A6 Group 6 Structures (Water-Control Structures)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A6.TP-223 3.5-1, 062 Group 6: Wooden Piles; sheeting Wood Air - outdoor, water - flowing or standing, groundwater/soil Loss of material; change in material properties due to weathering, chemical degradation, and insect infestation repeated wetting and drying, fungal decay AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" or the FERC / US Army Corp of Engineers dam inspections and maintenance programs.
No III.A6.T-12 3.5-1, 070 Masonry walls: all Concrete block Air - indoor uncontrolled, air
- outdoor Cracking due to restraint shrinkage, creep, and aggressive environment AMP XI.S5, "Masonry Walls" No N
III.A6.TP-34 3.5-1, 071 Masonry walls: all Concrete block Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S5, "Masonry Walls" No M
III.A6.TP-7 3.5-1, 072 Seals; gaskets; moisture barriers (caulking, flashing, and other sealants)
Elastomer, rubber and other similar materials Any Loss of sealing due to wear, damage, erosion, tear, surface cracks, other defects AMP XI.S6, "Structures Monitoring" No
III A6-8 III STRUCTURES AND COMPONENT SUPPORTS Table A6 Group 6 Structures (Water-Control Structures)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A6.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A6.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No E
III.A6.TP-221 3.5-1, 083 Structural bolting Steel Air - indoor uncontrolled, air
- outdoor, water
- flowing or standing Loss of material due to general, pitting, crevice corrosion AMP XI.S7, "Inspection of Water-Control Structures Associated with Nuclear Power Plants" or the FERC / US Army Corp of Engineers dam inspections and maintenance programs.
No
III A7-1 A7.
GROUP 7 STRUCTURES (CONCRETE TANKS AND MISSILE BARRIERS)
Systems, Structures, and Components This section addresses the elements of concrete tanks and missile barriers. For this group, the applicable structural elements are identified: (i) concrete and (ii) steel. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed structures and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A7-2 III STRUCTURES AND COMPONENT SUPPORTS Table A7 Group 7 Structures (Concrete Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A7.TP-25 3.5-1, 054 Concrete (accessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A7.TP-27 3.5-1, 065 Concrete (accessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A7.TP-23 3.5-1, 064 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S6, "Structures Monitoring" No III.A7.TP-24 3.5-1, 063 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S6, "Structures Monitoring" No III.A7.TP-26 3.5-1, 066 Concrete (accessible areas): interior and above-grade exterior Concrete Air - indoor uncontrolled, air
- outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No
III A7-3 III STRUCTURES AND COMPONENT SUPPORTS Table A7 Group 7 Structures (Concrete Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A7.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes III.A7.TP-212 3.5-1, 065 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A7.TP-29 3.5-1, 067 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No M
III.A7.TP-67 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, Structures Monitoring, enhanced as necessary Yes
III A7-4 III STRUCTURES AND COMPONENT SUPPORTS Table A7 Group 7 Structures (Concrete Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A7.TP-108 3.5-1, 042 Concrete (inaccessible areas):
foundation Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A7.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes E
III.A7.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes
III A7-5 III STRUCTURES AND COMPONENT SUPPORTS Table A7 Group 7 Structures (Concrete Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.A7.TP-28 3.5-1, 067 Concrete:
interior; above-grade exterior Concrete Air - indoor uncontrolled, air
- outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No E
III.A7.TP-302 3.5-1, 077 Steel components: all structural steel Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No E
III.A7.T-23 3.5-1, 052 Steel components:
tank liner Stainless steel Water - standing Cracking due to SCC; loss of material due to pitting and crevice corrosion Plant-specific aging management program Yes E
III.A7.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A7.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A7.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A7.TP-300
III A8-1 A8.
GROUP 8 STRUCTURES (STEEL TANKS AND MISSILE BARRIERS)
Systems, Structures, and Components This section addresses the elements of steel tanks and missile barriers. For this group, the applicable structural elements are identified: (i) concrete and (ii) steel. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed structures and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A8-2 III STRUCTURES AND COMPONENT SUPPORTS Table A8 Group 8 Structures (Steel Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A8.TP-25 3.5-1, 054 Concrete (accessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A8.TP-27 3.5-1, 065 Concrete (accessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A8.TP-23 3.5-1, 064 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S6, "Structures Monitoring" No III.A8.TP-24 3.5-1, 063 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S6, "Structures Monitoring" No
III A8-3 III STRUCTURES AND COMPONENT SUPPORTS Table A8 Group 8 Structures (Steel Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A8.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes III.A8.TP-212 3.5-1, 065 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A8.TP-29 3.5-1, 067 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No M
III.A8.TP-67 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
III A8-4 III STRUCTURES AND COMPONENT SUPPORTS Table A8 Group 8 Structures (Steel Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A8.TP-108 3.5-1, 042 Concrete (inaccessible areas):
foundation Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A8.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes E
III.A8.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction of foundation strength and cracking due to differential settlement and erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes E
III.A8.TP-302 3.5-1, 077 Steel components:
all structural steel Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to corrosion AMP XI.S6, "Structures Monitoring" No
III A8-5 III STRUCTURES AND COMPONENT SUPPORTS Table A8 Group 8 Structures (Steel Tanks and Missile Barriers)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A8.T-23 3.5-1, 052 Steel components:
tank liner Stainless steel Water - standing Cracking due to SCC; loss of material due to pitting and crevice corrosion Plant-specific aging management program Yes E
III.A8.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A8.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A8.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A8.TP-300
III A9-1 A9.
GROUP 9 STRUCTURES (BOILING WATER REACTOR UNIT VENT STACK)
Systems, Structures, and Components This section addresses the elements of the boiling water reactor (BWR) unit vent stack. For this group, the applicable structural element is identified: concrete. The aging management review (AMR) is presented for each applicable combination of structural element and aging effect.
System Interfaces Physical interfaces exist with any system or component that either penetrates the structure wall or is supported by the structure wall, floor, and roof. The direct interface is through the system or component supports that are anchored to the structure. Structures also protect housed structures and components from internal and external design basis events. In the case of tanks, there is a functional interface with the associated system. Water-control structures are integral parts of the systems that provide plant cooling water and residual heat removal.
III A9-2 III STRUCTURES AND COMPONENT SUPPORTS Table A9 Group 9 Structures (BWR Unit Vent Stack)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation E
III.A9.TP-25 3.5-1, 054 Concrete (accessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates AMP XI.S6, "Structures Monitoring" No III.A9.TP-27 3.5-1, 065 Concrete (accessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A9.TP-23 3.5-1, 064 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Air - outdoor Loss of material (spalling, scaling) and cracking due to freeze-thaw AMP XI.S6, "Structures Monitoring" No III.A9.TP-24 3.5-1, 063 Concrete (accessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation AMP XI.S6, "Structures Monitoring" No III.A9.TP-26 3.5-1, 066 Concrete (accessible areas): interior and above-grade exterior Concrete Air - indoor uncontrolled, air
- outdoor Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No
III A9-3 III STRUCTURES AND COMPONENT SUPPORTS Table A9 Group 9 Structures (BWR Unit Vent Stack)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A9.TP-204 3.5-1, 043 Concrete (inaccessible areas): all Concrete Any Cracking due to expansion from reaction with aggregates Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes III.A9.TP-212 3.5-1, 065 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Cracking; loss of bond; and loss of material (spalling, scaling) due to corrosion of embedded steel AMP XI.S6, "Structures Monitoring" No III.A9.TP-29 3.5-1, 067 Concrete (inaccessible areas): below-grade exterior; foundation Concrete Groundwater/soil Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No M
III.A9.TP-67 3.5-1, 047 Concrete (inaccessible areas): exterior above-and below-grade; foundation Concrete Water - flowing Increase in porosity and permeability; loss of strength due to leaching of calcium hydroxide and carbonation Plant-specific aging management program, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes
III A9-4 III STRUCTURES AND COMPONENT SUPPORTS Table A9 Group 9 Structures (BWR Unit Vent Stack)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.A9.TP-108 3.5-1, 042 Concrete (inaccessible areas):
foundation Concrete Air - outdoor, groundwater/soil Loss of material (spalling, scaling) and cracking due to freeze-thaw Plant-specific aging management program to be evaluated for plants in moderate to severe weathering conditions, or AMP XI.S6, "Structures Monitoring,"
enhanced as necessary Yes E
III.A9.TP-30 3.5-1, 044 Concrete: all Concrete Soil Cracking and distortion due to increased stress levels from settlement AMP XI.S6, "Structures Monitoring" Yes E
III.A9.TP-31 3.5-1, 046 Concrete:
foundation; subfoundation Concrete; porous concrete Water - flowing Reduction in foundation strength, cracking due to differential settlement, erosion of porous concrete subfoundation AMP XI.S6, "Structures Monitoring" Yes
III A9-5 III STRUCTURES AND COMPONENT SUPPORTS Table A9 Group 9 Structures (BWR Unit Vent Stack)
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.A9.TP-28 3.5-1, 067 Concrete:
interior; above-grade exterior Concrete Air - indoor uncontrolled, air
- outdoor Increase in porosity and permeability; cracking; loss of material (spalling, scaling) due to aggressive chemical attack AMP XI.S6, "Structures Monitoring" No E
III.A9.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.A9.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air
- outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.A9.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No D
III.A9.TP-300
III B-1 III COMPONENT SUPPORTS B1.
SUPPORTS FOR ASME PIPING AND COMPONENTS B1.1 CLASS 1 B1.2 CLASS 2 AND CLASS 3 B1.3 CLASS MC (BWR CONTAINMENT SUPPORTS)
B2.
SUPPORTS FOR CABLE TRAYS, CONDUIT, HVAC DUCTS, TUBETRACK, INSTRUMENT TUBING, NON-ASME PIPING AND COMPONENTS B3.
ANCHORAGE OF RACKS, PANELS, CABINETS, AND ENCLOSURES FOR ELECTRICAL EQUIPMENT AND INSTRUMENTATION B4.
SUPPORTS FOR EMERGENCY DIESEL GENERATOR (EDG), HVAC SYSTEM COMPONENTS, AND OTHER MISCELLANEOUS MECHANICAL EQUIPMENT B5.
SUPPORTS FOR PLATFORMS, PIPE WHIP RESTRAINTS, JET IMPINGEMENT SHIELDS, MASONRY WALLS, AND OTHER MISCELLANEOUS STRUCTURES
III B1-1 B1.
SUPPORTS FOR ASME PIPING AND COMPONENTS Systems, Structures, and Components This section addresses supports and anchorage for American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) piping systems and components. It is subdivided into Class 1 (III.B1.1), Class 2 and Class 3 (III.B1.2), and Class MC (III.B1.3). Applicable aging effects are identified and the aging management review (AMR) is presented for each applicable combination of support component and aging effect.
System Interfaces Physical interfaces exist with the structure, system, or component being supported and with the building structural element to which the support is anchored. A primary function of supports is to provide anchorage of the supported element for internal and external design basis events so that the supported element can perform its intended function.
III B1-2 III STRUCTURES AND COMPONENT SUPPORTS Table B1.1 Class 1
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.1.TP-42 3.5-1, 055 Building concrete at locations of expansion and grouted anchors; grout pads for support base plates Concrete; grout Air - indoor uncontrolled, air - outdoor Reduction in concrete anchor capacity due to local concrete degradation/ service-induced cracking or other concrete aging mechanisms AMP XI.S6, "Structures Monitoring" No M
III.B1.1.T-28 3.5-1, 057 Constant and variable load spring hangers; guides; stops Steel Air - indoor uncontrolled, air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.1.TP-41 3.5-1, 068 High-strength structural bolting High-strength steel Air Cracking due to SCC AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.1.TP-45 3.5-1, 075 Sliding surfaces Lubrite; graphitic tool steel; Fluorogold; Lubrofluor Air - indoor uncontrolled, air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S3, "ASME Section XI, Subsection IWF" No E
III.B1.1.TP-229 3.5-1, 087 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S3, "ASME Section XI, Subsection IWF" No
III B1-3 III STRUCTURES AND COMPONENT SUPPORTS Table B1.1 Class 1
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.1.TP-232 3.5-1, 085 Structural bolting Stainless steel Treated water Loss of material due to pitting, crevice corrosion AMP XI.M2, "Water Chemistry," and AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.1.TP-226 3.5-1, 081 Structural Bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.1.TP-235 3.5-1, 086 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No N
III.B1.1.T-36a 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M32, "One-Time Inspection" Yes N
III.B1.1.T-36b 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.S3, "ASME Section XI, Subsection IWF" Yes
III B1-4 III STRUCTURES AND COMPONENT SUPPORTS Table B1.1 Class 1
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.B1.1.T-36c 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M36, "External Surfaces Monitoring of Mechanical Components" Yes M
III.B1.1.TP-8 3.5-1, 095 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - indoor uncontrolled None None No M
III.B1.1.TP-3 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No
III B1-5 III STRUCTURES AND COMPONENT SUPPORTS Table B1.1 Class 1
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B1.1.TP-4 3.5-1, 098 Support members; welds; bolted connections; support anchorage to building structure Stainless
III.B1.1.T-26 3.5-1, 053 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled Cumulative fatigue damage due to cyclic loading (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.3 "Metal Fatigue," and/or Section 4.7 "Other Plant-Specific Time-Limited Aging Analyses" Yes III.B1.1.T-24 3.5-1, 091 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No
III B1-6 III STRUCTURES AND COMPONENT SUPPORTS Table B1.1 Class 1
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.1.T-25 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No E
III.B1.1.TP-10 3.5-1, 090 Support members; welds; bolted connections; support anchorage to building structure Steel; stainless steel Treated water Loss of material due to general (steel only), pitting, crevice corrosion AMP XI.M2, "Water Chemistry," and AMP XI.S3, "ASME Section XI, Subsection IWF" No III.B1.1.T-33 3.5-1, 094 Vibration isolation elements Non-metallic (e.g., rubber)
Air - indoor uncontrolled, air - outdoor Reduction or loss of isolation function due to radiation hardening, temperature, humidity, sustained vibratory loading AMP XI.S3, "ASME Section XI, Subsection IWF" No
III B1-7 III STRUCTURES AND COMPONENT SUPPORTS Table B1.2 Class 2 and Class 3
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.2.TP-42 3.5-1, 055 Building concrete at locations of expansion and grouted anchors; grout pads for support base plates Concrete; grout Air - indoor uncontrolled, air - outdoor Reduction in concrete anchor capacity due to local concrete degradation/ service-induced cracking or other concrete aging mechanisms AMP XI.S6, "Structures Monitoring" No M
III.B1.2.T-28 3.5-1, 057 Constant and variable load spring hangers; guides; stops Steel Air - indoor uncontrolled, air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.2.TP-45 3.5-1, 075 Sliding surfaces Lubrite; graphitic tool steel; Fluorogold; Lubrofluor Air - indoor uncontrolled, air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S3, "ASME Section XI, Subsection IWF" No E
III.B1.2.TP-229 3.5-1, 087 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S3, "ASME Section XI, Subsection IWF" No
III B1-8 III STRUCTURES AND COMPONENT SUPPORTS Table B1.2 Class 2 and Class 3
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.2.TP-232 3.5-1, 085 Structural bolting Stainless steel Treated water Loss of material due to pitting, crevice corrosion AMP XI.M2, "Water Chemistry," and AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.2.TP-226 3.5-1, 081 Structural bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.2.TP-235 3.5-1, 086 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No N
III.B1.2.T-36a 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M32, "One-Time Inspection" Yes
III B1-9 III STRUCTURES AND COMPONENT SUPPORTS Table B1.2 Class 2 and Class 3
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.B1.2.T-36b 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.S3, "ASME Section XI, Subsection IWF" Yes N
III.B1.2.T-36c 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M36, "External Surfaces Monitoring of Mechanical Components" Yes M
III.B1.2.TP-8 3.5-1, 095 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - indoor uncontrolled None None No
III B1-10 III STRUCTURES AND COMPONENT SUPPORTS Table B1.2 Class 2 and Class 3
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B1.2.TP-3 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No M
III.B1.2.TP-4 3.5-1, 098 Support members; welds; bolted connections; support anchorage to building structure Stainless
III.B1.2.T-26 3.5-1, 053 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled Cumulative fatigue damage due to cyclic loading (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.3 "Metal Fatigue," and/or Section 4.7 "Other Plant-Specific Time-Limited Aging Analyses" Yes
III B1-11 III STRUCTURES AND COMPONENT SUPPORTS Table B1.2 Class 2 and Class 3
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.2.T-24 3.5-1, 091 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No III.B1.2.T-25 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No III.B1.2.T-33 3.5-1, 094 Vibration isolation elements Non-metallic (e.g., rubber)
Air - indoor uncontrolled, air - outdoor Reduction or loss of isolation function due to radiation hardening, temperature, humidity, sustained vibratory loading AMP XI.S3, "ASME Section XI, Subsection IWF" No
III B1-12 III STRUCTURES AND COMPONENT SUPPORTS Table B1.3 Class MC
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.3.TP-42 3.5-1, 055 Building concrete at locations of expansion and grouted anchors; grout pads for support base plates Concrete; grout Air - indoor uncontrolled, air - outdoor Reduction in concrete anchor capacity due to local concrete degradation/
service-induced cracking or other concrete aging mechanisms AMP XI.S6, "Structures Monitoring" No M
III.B1.3.T-28 3.5-1, 057 Constant and variable load spring hangers; guides; stops Steel Air - indoor uncontrolled, air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.3.TP-45 3.5-1, 075 Sliding surfaces Lubrite; graphitic tool steel; Fluorogold; Lubrofluor Air - indoor uncontrolled, air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S3, "ASME Section XI, Subsection IWF" No E
III.B1.3.TP-229 3.5-1, 087 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S3, "ASME Section XI, Subsection IWF" No
III B1-13 III STRUCTURES AND COMPONENT SUPPORTS Table B1.3 Class MC
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B1.3.TP-232 3.5-1, 085 Structural bolting Stainless steel Treated water Loss of material due to pitting, crevice corrosion AMP XI.M2, "Water Chemistry," and AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.3.TP-226 3.5-1, 081 Structural bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No M
III.B1.3.TP-235 3.5-1, 086 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No N
III.B1.3.T-36a 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M32, "One-Time Inspection" Yes N
III.B1.3.T-36b 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.S3, "ASME Section XI, Subsection IWF" Yes
III B1-14 III STRUCTURES AND COMPONENT SUPPORTS Table B1.3 Class MC
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.B1.3.T-36c 3.5-1, 099 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M36, "External Surfaces Monitoring of Mechanical Components" Yes M
III.B1.3.TP-8 3.5-1, 095 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - indoor uncontrolled None None No M
III.B1.3.TP-3 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No M
III.B1.3.TP-4 3.5-1, 098 Support members; welds; bolted connections; support anchorage to building structure Stainless
III B1-15 III STRUCTURES AND COMPONENT SUPPORTS Table B1.3 Class MC
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B1.3.T-26 3.5-1, 053 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled Cumulative fatigue damage due to cyclic loading (Only if CLB fatigue analysis exists)
TLAA, SRP-SLR Section 4.3 "Metal Fatigue," and/or Section 4.7 "Other Plant-Specific Time-Limited Aging Analyses" Yes III.B1.3.T-24 3.5-1, 091 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting corrosion AMP XI.S3, "ASME Section XI, Subsection IWF" No III.B1.3.T-33 3.5-1, 094 Vibration isolation elements Non-metallic (e.g., rubber)
Air - indoor uncontrolled, air - outdoor Reduction or loss of isolation function due to radiation hardening, temperature, humidity, sustained vibratory loading AMP XI.S3, "ASME Section XI, Subsection IWF" No
III B2-1 B2.
SUPPORTS FOR CABLE TRAYS, CONDUIT, HVAC DUCTS, TUBETRACK, INSTRUMENT TUBING, NON-ASME PIPING AND COMPONENTS Systems, Structures, and Components This section addresses supports and anchorage for cable trays, conduit, heating, ventilation, and air-conditioning ducts, TubeTrack, instrument tubing, and non-American Society of Mechanical Engineers Boiler and Pressure Vessel Code (non-ASME Code) piping and components.
Applicable aging effects are identified and the aging management review (AMR) is presented for each applicable combination of support component and aging effect.
System Interfaces Physical interfaces exist with the structure, system, or component being supported and with the building structural element to which the support is anchored. A primary function of supports is to provide anchorage of the supported element for internal and external design basis events so that the supported element can perform its intended function.
III B2-2 III STRUCTURES AND COMPONENT SUPPORTS Table B2 Support for Cable Trays, Conduit, HVAC Ducts, Tube Track, Instrument Tubing, Non-ASME Piping and Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B2.TP-42 3.5-1, 055 Building concrete at locations of expansion and grouted anchors; grout pads for support base plates Concrete; grout Air - indoor uncontrolled, air - outdoor Reduction in concrete anchor capacity due to local concrete degradation/ service-induced cracking or other concrete aging mechanisms AMP XI.S6, "Structures Monitoring" No M
III.B2.TP-46 3.5-1, 074 Sliding support bearings; sliding support surfaces Lubrite; graphitic tool steel; Fluorogold; Lubrofluor Air - indoor uncontrolled Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S6, "Structures Monitoring" No M
III.B2.TP-47 3.5-1, 074 Sliding support bearings; sliding support surfaces Lubrite; graphitic tool steel; Fluorogold; Lubrofluor Air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S6, "Structures Monitoring" No E
III.B2.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.B2.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No
III B2-3 III STRUCTURES AND COMPONENT SUPPORTS Table B2 Support for Cable Trays, Conduit, HVAC Ducts, Tube Track, Instrument Tubing, Non-ASME Piping and Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B2.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No N
III.B2.T-37a 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M32, "One-Time Inspection" Yes N
III.B2.T-37b 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.S6, "Structures Monitoring" Yes N
III.B2.T-37c 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M36, "External Surfaces Monitoring of Mechanical Components" Yes
III B2-4 III STRUCTURES AND COMPONENT SUPPORTS Table B2 Support for Cable Trays, Conduit, HVAC Ducts, Tube Track, Instrument Tubing, Non-ASME Piping and Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B2.TP-8 3.5-1, 095 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - indoor uncontrolled None None No M
III.B2.TP-6 3.5-1, 093 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - outdoor Loss of material due to pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No M
III.B2.TP-3 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No
III B2-5 III STRUCTURES AND COMPONENT SUPPORTS Table B2 Support for Cable Trays, Conduit, HVAC Ducts, Tube Track, Instrument Tubing, Non-ASME Piping and Components
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B2.TP-4 3.5-1, 098 Support members; welds; bolted connections; support anchorage to building structure Stainless steel, aluminum alloy Air with borated water leakage None None No III.B2.TP-43 3.5-1, 092 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting corrosion AMP XI.S6, "Structures Monitoring" No III.B2.T-25 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No D
III.B2.TP-300
III B3-1 B3.
ANCHORAGE OF RACKS, PANELS, CABINETS, AND ENCLOSURES FOR ELECTRICAL EQUIPMENT AND INSTRUMENTATION Systems, Structures, and Components This section addresses supports and anchorage for racks, panels, cabinets, and enclosures for electrical equipment and instrumentation. Applicable aging effects are identified and the aging management review (AMR) is presented for each applicable combination of support component and aging effect.
System Interfaces Physical interfaces exist with the structure, system, or component being supported and with the building structural element to which the support is anchored. A primary function of supports is to provide anchorage of the supported element for internal and external design basis events so that the supported element can perform its intended function.
III B3-2 III STRUCTURES AND COMPONENT SUPPORTS Table B3 Anchorage of Racks, Panels, Cabinets, and Enclosures for Electrical Equipment and Instrumentation
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B3.TP-42 3.5-1, 055 Building concrete at locations of expansion and grouted anchors; grout pads for support base plates Concrete; grout Air - indoor uncontrolled, air - outdoor Reduction in concrete anchor capacity due to local concrete degradation/ service-induced cracking or other concrete aging mechanisms AMP XI.S6, "Structures Monitoring" No E
III.B3.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.B3.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.B3.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No N
III.B3.T-37a 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M32, "One-Time Inspection" Yes N
III.B3.T-37b 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.S6, "Structures Monitoring" Yes
III B3-3 III STRUCTURES AND COMPONENT SUPPORTS Table B3 Anchorage of Racks, Panels, Cabinets, and Enclosures for Electrical Equipment and Instrumentation
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.B3.T-37c 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M36, "External Surfaces Monitoring of Mechanical Components" Yes M
III.B3.TP-8 3.5-1, 095 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - indoor uncontrolled None None No M
III.B3.TP-3 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No M
III.B3.TP-4 3.5-1, 098 Support members; welds; bolted connections; support anchorage to building structure Stainless
- steel, aluminum alloy Air with borated water leakage None None No III.B3.TP-43 3.5-1, 092 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting corrosion AMP XI.S6, "Structures Monitoring" No
III B3-4 III STRUCTURES AND COMPONENT SUPPORTS Table B3 Anchorage of Racks, Panels, Cabinets, and Enclosures for Electrical Equipment and Instrumentation
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B3.T-25 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No D
III.B3.TP-300
III B4-1 B4.
SUPPORTS FOR EMERGENCY DIESEL GENERATOR, HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM COMPONENTS, AND OTHER MISCELLANEOUS MECHANICAL EQUIPMENT Systems, Structures, and Components This section addresses supports and anchorage for the emergency diesel generator (EDG) and heating, ventilation, and air conditioning (HVAC) system components, and other miscellaneous mechanical equipment. Applicable aging effects are identified and the aging management review (AMR) is presented for each applicable combination of support component and aging effect.
System Interfaces Physical interfaces exist with the structure, system, or component being supported and with the building structural element to which the support is anchored. A primary function of supports is to provide anchorage of the supported element for internal and external design basis events so that the supported element can perform its intended function.
III B4-2 III STRUCTURES AND COMPONENT SUPPORTS Table B4 Supports for Emergency Diesel Generator, HVAC System Components, and Other Miscellaneous Mechanical Equipment
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation III.B4.TP-42 3.5-1, 055 Building concrete at locations of expansion and grouted anchors; grout pads for support base plates Concrete; grout Air - indoor uncontrolled, air - outdoor Reduction in concrete anchor capacity due to local concrete degradation/ service-induced cracking or other concrete aging mechanisms AMP XI.S6, "Structures Monitoring" No M
III.B4.TP-46 3.5-1, 074 Sliding support bearings; sliding support surfaces Lubrite; graphitic tool steel; Fluorogold; Lubrofluor Air - indoor uncontrolled Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S6, "Structures Monitoring" No M
III.B4.TP-47 3.5-1, 074 Sliding support bearings; sliding support surfaces Lubrite; graphitic tool steel; Fluorogold; Lubrofluor Air - outdoor Loss of mechanical function due to corrosion, distortion, dirt or debris accumulation, overload, wear AMP XI.S6, "Structures Monitoring" No E
III.B4.TP-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.B4.TP-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.B4.TP-274 3.5-1, 082 Structural bolting Steel; galvanized steel Air - outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No
III B4-3 III STRUCTURES AND COMPONENT SUPPORTS Table B4 Supports for Emergency Diesel Generator, HVAC System Components, and Other Miscellaneous Mechanical Equipment
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation N
III.B4.T-37a 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M32, "One-Time Inspection" Yes N
III.B4.T-37b 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.S6, "Structures Monitoring" Yes N
III.B4.T-37c 3.5-1, 100 Support members; welds; bolted connections; support anchorage to building structure
- Aluminum, stainless steel
- Air, condensation Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M36, "External Surfaces Monitoring of Mechanical Components" Yes
III B4-4 III STRUCTURES AND COMPONENT SUPPORTS Table B4 Supports for Emergency Diesel Generator, HVAC System Components, and Other Miscellaneous Mechanical Equipment
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B4.TP-8 3.5-1, 095 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - indoor uncontrolled None None No M
III.B4.TP-6 3.5-1, 093 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air - outdoor Loss of material due to pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No M
III.B4.TP-3 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Galvanized steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No
III B4-5 III STRUCTURES AND COMPONENT SUPPORTS Table B4 Supports for Emergency Diesel Generator, HVAC System Components, and Other Miscellaneous Mechanical Equipment
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B4.TP-4 3.5-1, 098 Support members; welds; bolted connections; support anchorage to building structure Stainless
- steel, aluminum alloy Air with borated water leakage None None No III.B4.TP-43 3.5-1, 092 Support members; welds; bolted connections; support anchorage to building structure Steel Air - indoor uncontrolled, air - outdoor Loss of material due to general, pitting corrosion AMP XI.S6, "Structures Monitoring" No III.B4.T-25 3.5-1, 089 Support members; welds; bolted connections; support anchorage to building structure Steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No
III B4-6 III STRUCTURES AND COMPONENT SUPPORTS Table B4 Supports for Emergency Diesel Generator, HVAC System Components, and Other Miscellaneous Mechanical Equipment
- New, Modified,
- Deleted, Edited Item Item SRP Item (Table, ID)
Structure and/or Component Material Environment Aging Effect/Mechanism Aging Management Program (AMP)/TLAA Further Evaluation M
III.B4.TP-44 3.5-1, 094 Vibration isolation elements Non-metallic (e.g., rubber)
Air - indoor uncontrolled, air - outdoor Reduction or loss of isolation function due to radiation hardening, temperature, humidity, sustained vibratory loading AMP XI.S6, "Structures Monitoring" No D
III.B4.TP-300
III B5-1 B5.
SUPPORTS FOR PLATFORMS, PIPE WHIP RESTRAINTS, JET IMPINGEMENT SHIELDS, MASONRY WALLS, AND OTHER MISCELLANEOUS STRUCTURES Systems, Structures, and Components This section addresses supports and anchorage for platforms, pipe whip restraints, jet impingement shields, masonry walls, and other miscellaneous structures. Applicable aging effects are identified and the aging management review (AMR) is presented for each applicable combination of support component and aging effect.
System Interfaces Physical interfaces exist with the structure, system, or component being supported and with the building structural element to which the support is anchored. A primary function of supports is to provide anchorage of the supported element for internal and external design basis events so that the supported element can perform its intended function.
III B5-2 III STRUCTURES AND COMPONENT SUPPORTS Table B5 Supports for Platforms, Pipe Whip Restraints, Jet Impingement Shields, Masonry Walls, and Other Miscellaneous Structures
- New, Modifie d,
Deleted
, Edited Item Item SRP Item (Tabl e, ID)
Structure and/or Compone nt Material Environme nt Aging Effect/Mechani sm Aging Manageme nt Program (AMP)/TLA A
Further Evaluati on III.B5.T P-42 3.5-1, 055 Building concrete at locations of expansion and grouted anchors; grout pads for support base plates Concrete; grout Air - indoor uncontrolle d, air -
outdoor Reduction in concrete anchor capacity due to local concrete degradation/
service-induced cracking or other concrete aging mechanisms AMP XI.S6, "Structures Monitoring" No E
III.B5.T P-261 3.5-1, 088 Structural bolting Any Any Loss of preload due to self-loosening AMP XI.S6, "Structures Monitoring" No M
III.B5.T P-248 3.5-1, 080 Structural bolting Steel Air - indoor uncontrolle d, air -
outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No III.B5.T P-274 3.5-1, 082 Structural bolting Steel; galvanize d steel Air -
outdoor Loss of material due to general, pitting, crevice corrosion AMP XI.S6, "Structures Monitoring" No N
III.B5.T-37a 3.5-1, 100 Support members; welds; bolted connection s; support anchorage to building structure Aluminu m,
stainless steel
- Air, condensati on Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M32, "One-Time Inspection" Yes N
III.B5.T-37b 3.5-1, 100 Support members; welds; bolted connection s; support anchorage to building structure Aluminu m,
stainless steel
- Air, condensati on Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.S6, "Structures Monitoring" Yes
III B5-3 III STRUCTURES AND COMPONENT SUPPORTS Table B5 Supports for Platforms, Pipe Whip Restraints, Jet Impingement Shields, Masonry Walls, and Other Miscellaneous Structures
- New, Modifie d,
Deleted
, Edited Item Item SRP Item (Tabl e, ID)
Structure and/or Compone nt Material Environme nt Aging Effect/Mechani sm Aging Manageme nt Program (AMP)/TLA A
Further Evaluati on N
III.B5.T-37c 3.5-1, 100 Support members; welds; bolted connection s; support anchorage to building structure Aluminu m,
stainless steel
- Air, condensati on Loss of material due to pitting and crevice corrosion, cracking due to SCC AMP XI.M36, "External Surfaces Monitoring of Mechanical Component s"
Yes M
III.B5.T P-8 3.5-1, 095 Support members; welds; bolted connection s; support anchorage to building structure Galvaniz ed steel Air - indoor uncontrolle d
None None No M
III.B5.T P-3 3.5-1, 089 Support members; welds; bolted connection s; support anchorage to building structure Galvaniz ed steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No M
III.B5.T P-4 3.5-1, 098 Support members; welds; bolted connection s; support anchorage to building structure Stainless
III B5-4 III STRUCTURES AND COMPONENT SUPPORTS Table B5 Supports for Platforms, Pipe Whip Restraints, Jet Impingement Shields, Masonry Walls, and Other Miscellaneous Structures
- New, Modifie d,
Deleted
, Edited Item Item SRP Item (Tabl e, ID)
Structure and/or Compone nt Material Environme nt Aging Effect/Mechani sm Aging Manageme nt Program (AMP)/TLA A
Further Evaluati on III.B5.T P-43 3.5-1, 092 Support members; welds; bolted connection s; support anchorage to building structure Steel Air - indoor uncontrolle d, air -
outdoor Loss of material due to general, pitting corrosion AMP XI.S6, "Structures Monitoring" No III.B5.T-25 3.5-1, 089 Support members; welds; bolted connection s; support anchorage to building structure Steel Air with borated water leakage Loss of material due to boric acid corrosion AMP XI.M10, "Boric Acid Corrosion" No D
III.B5.T P-300