June 4, 1990 Docket No. 50-440 DISTRIBUTION:

eDoctet. M ies,,;NRC & Local PDRs "PDill-3 r/f JZwolinski JHannon TColburn i

PKreutzer OGC-WF1 Mr. Michael Lyster, Vice President EJordan (ACRS)

Nuclear Group PDill-3 Gray The Cleveland Electric 111uminating Company 10 Center Road i

Perry, Ohio 44081

Dear Mr. Lyster:

SUBJECT:

RESPONSE TO NRC BULLETIN 88-04, " POTENTIAL SAFETY-RELATED PUMP LOSS" (TACNO.69954)

On May 5,1988, the NRC staff issued NRC Bulletin 88-04, " Potential Safety-Related Pump (Loss."1) pump-to pump interaction during miniflow o The bulletin requested the evaluation of all safety-related pumps for dead-heading of one or more of the pt.mps, and (2) peration that could result in the adequacy of the minimum flow bypass lines with respect to dama p resulting from operation and testing in the minimum flow mode.

By letter datt.d July 11, 1988, you provided your initial response to the bulletin.

After completing our review of your initial response, by letter dated May 31, 1989, we identified concerns with informatior provided in your response related to operation of the reactor core isolation cooling (RCIC) system in the mini-flow configuration.

Specifically, your initial response indicated that operation of the RCIC pump at the installed minimum flow capacity would be acceptable for only a time period of less than 20 seconds. We requested that you re-review your corrective action proposed in your July ll,1988,

. letter or justify how this action would be sufficient to prevent pump damage during all expected operating conditions, i

By letters dated December 13, 1989 and January 9,1990, you responded to our request for additional information.

Your responses indicated that af ter discussions with the RCIC pump manufacturer, you have revised your determination of how long the RCIC pump can operate under minimum-flow l

conditions without pump damage (to 10 minutes in a 24-hour period) and have revised the operating instructions to implement the manufacturer's recommendations.

Based upon a review your submittals we have determined that your responses to NRC Bulletin 88-04 adequately address the staff's concerns; therefore, I

I 900614o433 900604 PDR ADOCK 0300 go Al

&0

y.,-

iy:

l k',[..

<i c

a_

Ej, '

June 4,21990 Mr.-Michael Lyster *

~ this item is considered closed'for your ' facility.

You are reminded that, as discussed in Bulletin 88-04, you should document and maintain for.at

-least' 2 years an evaluation of'your actions in responding to the bulletin...

c i

=These records may.be subject to future auditing, Sincerely,.

/s/

J Timothy G. Colburn, Sr. Project Manager

'J Project Directorate 111-3.

Division of Reactor Projects - Ill, IV, V and Special Projects

.m' Office of Nuclear Reactor Regulation cc: See next page f

l1 t

i i

l i

. DOCUMENT ~NAME: TAC 69954 BULLETIN 88-04 Office:

LA/PD 11-3 PM/P

-3 PM/

P /PDill-3

, Surname:

PKr ter TColburn/tg TAlex on '

JHannon Date:

4 / 6 /90 f /3/ /90 f/ 3l /90 ff /f/90 l

[3:

m y

![

3 4I,t

a 6 '

d' Mr. Michael D. Lyster Perry Nuclear Power Plant The Cleveland Electric Unit 1 Illuminating Company L

cc:-Jay _E. S11 berg,'Esq.

Mr. James W. Harris, Director-Shaw, Pittman, Potts & Trowbridge Division of Power Generation 2300 N Street, N.W.

Ohio Department of Industrial Washington, D.C.

20037 Relations P. O. Box 825 David E. Burke Columbus, Ohio 43216 The Cleveland Electric Illuminating Company The Honorable Lawrence Logan P.O. Box 5000 '

Mayor, Village of-Perry Cleveland, Ohio 44101 4203 Harper Street Perry, Ohio 44081 Resident Inspector's Office U.S. Nuclear Regulatory Commission The Honorable Robert V. Orosz Parmly at Center Road Mayor, Village of North Perry Perry. Ohio 44081 North Perry Village Hall 4778 Lockwood Road Regional Administrator, Region 111 North Perry Village, Ohio 44081 U.S. Nuclear Regulatory Commission 799 Roosevelt Road Attorney General Glen Ellyn, Illinois 60137 Department of Attorney General 30 East Broad Street Frank P. Weiss, Esq.

Columbus, Ohio 43216 Assistant Prosecuting Attorney 105 Main' Street _

Radiological Health Program Lake County Administration Center Ohio Department of Health Painesville, Ohio 44077 1224 Kinnear Road Columbus, Ohio -43212

.Ms. Sue Hiatt OCRE Interim Representative Ohio Environmental Protection 8275 Munson Agency Mentor, Ohio 44060 DERR--Compliance Unit PO Box 1049 Terry'J. Lodge, Esq.

1800 Watermark Drive 618 N. Michigan Street ATTN: Zack A. Clayton fuite 105 Columbus, Ohio 43266-0149 Toledo,'0hio 43624 Mr. Phillip S. Haskell, Chairman John G. Cardinal, Esq.

Perry Township Board of Trustees Prosecuting Attorney-Box 65 Ashtabula County Courthouse 4171. Main Street Jefferson, Ohio 44047-Perry, Ohio 44081 Robert'A. Newkirk State of Ohio Cleveland Electric Public Utilities Commission Illuminating Company 180 East Broad Street

-Perry Nuclear Power Plant Columbus, Ohio 43266-0573 P. O. Box 97 E-210 Perry, Ohio 44081