APPENDIX-A NOTICE OF VIOLATION Duke Power Company Docket No. 50-413 Catawba Unit 1 License No. CPPR-116 As a result of the inspection conducted on September 26 - October 25, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7,1980),

the following violation.was identified.

10 CFR 50, Appendix B, Criterion V, as implemented by Topical Report Duke 1-A, Section 17, paragraph 17.15 requires that activities affecting quality be accomplished in-accordance with established procedures. Licensee pro-cedure Q1, Rev.15 requires proper. technical evaluations for nonconforming.

conditions.

Contrary to the above, a proper technical evaluation was not accomplished on September 18, 1981 for Class B weld INV 177-8 in that a rejectable lack of fusion defect was accepted by licensee personnel. This acceptance was-documented on Nonconforming Item Report No.12682.

This is a Severity Level V Violation (Supplement II.E.).

Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit to '

this office within thirty days of the date of this Notice, a written statement or.

explanation in reply, including:

(1) admission or. denial of the alleged viola-tion; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the-results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved. Consideration may be-given to extending your response time for good cause shown. Under the authority of Section 182 of the Atomic Energy Act of -

1954, as amended, this response shall be submitted under oath or affirmation.

The responses directed by this Notice are not subject to the clearance' procedures of the Office of flanagement and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.