RO 81-001:on 810117,foreign Matl Was Found in Sav Solenoid (Pilot) Valve (02-SOV-71G).Caused by Excess Adhesive & O-ring Lubricant Used by Vendor During Assembly.Insp of Remaining Nine Solenoid Valve Pairs Is in Progress
ML20037C125
Person / Time
Site: FitzPatrick 
Issue date: 01/21/1981
From: Pasternak R
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
RO-81-001, RO-81-1, NUDOCS 8101280136
Download: ML20037C125 (1)


Text

I TELECOPY MESSA&E TO:

President & Chief Operating Officer TO:

Director of Regulatory Operation Chairman, 5RC USNRC ResIon 1 Seafor Vice President-Muclear Generation 631 Park Avenue King of Prussia, Pennsylvania 194, DATE/ TIME: January 21, 1981 DATE/ TIME:

January 21, IS81 FRDM:

James A. Fir 2 Patrick Nuclear Pcaver Plant P. O. Box 41 co l

e Lycoming, New York 13093 c) 9 g'( f' 's I

quSJECT:

PROMPT REPORTA8LE OC{

  • J-L L

00CRET ND.

50-333 s'

JATJ 2 71981 * --

LICINSE NO. CPR-59 11 AssIr.utD OR ND.81-021

-,b "* %Y k LER NO.81-001 4

ronT oATE-January 21,1981l EVENT DATE:

January 21, 1981 nE EVENT DESCRIPTION:

i As port of an investigation into the failure of Safety Relief Valve (SRV) 02-RV-71G to open in response to manual (operator) desnand follow-l Ing a reactor scram and isolation on January 17, 1981, foreign smoterial was found in the SAV solenoid (pilot) valva (02-50V-71G).

'the foreign material has been identified by the vendor representative as excess l

adhesive (Loc-Tite) and 0-ring lubricant used by the vendor during assem6ly. The probless appears to be simiIar to that described in NRC IE Bulletin 80-25. The foreign material has been found in two (2) of eleven (11) solenoid valve pairs installed.

Inspection of the remaining nine (S) solenoid valve pairs with a vendor (Target Rock) representative is in progress.

COMPONENTS INVOLVE 1h I

flain Steam Safety / Relief Valvu (SRV) solenoid (pilot) valves 02-SDV-71 A, B, C, D, E, F, G. H, J, E and L.

,j CAUSE AMD REMEDIAL ACTION:

Cause is believed to be the result of procedural inadequacy of the type refer:

toln75g9.A.I.1.f.

Corrective action will satisfy the requirements of MRC IE t

IN$ 5 N!:

% THERNAL PCuta 0

itoutine Startup Shutden.n X

Routine Shutdce.n-Re fuel ing Steady State Pcwor Other Load Change Not Applicaule l

A wri ctsn follew up report will be sant within two weeks.

.))O IO w him <-

GRd.'W J. PA TERNM i

810 12801%

assioenT n e czR I