MISSISSIPPI STATE DEPARTMENT OF HEALTH Post Office Box 1700

  • 2423 North State Street a Jackson, Mississippi 39215-1700
  • 601/960-7400
  • FAX 601/960-7948 April 13,1993 U. S. Nuclear Regulatory Commission Attn: Office of Nuclear Reactor Regulation Radiation Protection Branch Washington, DC _20555 Gentlemen.

i Enclosed is Mississippi's 1992 Calendar Year report of environmental activities at the Grand -

Gulf Nuclear Station. These activities were conducted by the Division of Radiological Health, Mississippi State Department of Health, in accordance with Cooperative Agreement No. NRC-29-83-621.

'i The original was sent to the NRC's Public Document Room, Washington, DC. and a copy I

is being provided to the Division of Contracts and Property Management and the NRC's Regional Administrator and Project Officer. Should you have any questions regarding this-report, please direct them to Bob Bell at (601) 354-6657.

i Sincerely, l

Eddie S. Fuente, Director Division of Radiological Health ESF/sd a-Enclosure t

i

)

i 200016 Equal Opportunity in Employment / Services

_j I-9304210096 921231 1

PDR ADOCK 05000416

{,

i R

PDR 1

I REPORT TO THE NUCLEAR REGULATORY COMMISSION ElWIRONMENTAL MONITORING AT GRAND GULF NUCLEAR STATION CALENDAR YEAR 1992 NRC CONTRACT NUMBER NRC-29-83-621 I

ENVIRONMENTAL MONITORING AND EMERGENCY RESPONSE BRANCH DIVISION OF RADIOLOGICAL HEALTH MISSISSIPPI STATE DEPARTMENT OF HEALTH I

~.M Eddie S.

Fuente; Director, Division of Radiological Health 7A&3 Bob Bell; Health Physicist-Administrative, Environmental Monitoring and Emergency Response Branch I

I Abstract:

Under contract to the U.S. Nuclear Regulatory Commission (NRC), the Mississippi State Department of Health (MSDH), Division of Radiological Health (DRH) provides environmental radiological data to the NRC pertaining to the Grand Gulf Nuclear Station (GGNS), Claiborne County, Mississippi.

The results detailed in this report are for Calendar Year 1992 which represent the twelft.h year of this contract with the State of Mississippi.

Licensee for Grand Gulf Nuclear Station was System Energy Resources, Inc. (SERI) before June 6, 1990 and Entergy Operations, Inc. (Entergy Operations) on and after June 6, 1990.

I I

I I

I

~

I I

I I

I I

I I

GRAND GULF NUJI"AR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 TABLE OF CONTENTS I.

AIR SAMPLING STATION DATA PAGE A.

MSDH " Arnold Acres" & GGNS " Training Center" 1.

Particulate Gross Beta 2

2.

Radioiodine 6

3.

Quarterly Composite (Gamma Isotopic) 10 B.

MSDH " Rad Health Bldg" & GGNS "Vicksburg" 1.

Particulate Gross Beta Control 11 2.

Radiciodine Control 15 3.

Quarterly Composite (Gamma Isotopic) Control 19 II.

MISSISSIPPI' RIVER WATER DATA A. Gamma Isotopic Analysis 20 B.

Tritium 22 III.

MISSISSIPPI RIVER SHORELINE SEDIMENT Gamma Isotopic Analysis 24 IV.

ALCORN DAIRY MILK DATA A.

Gamma Isotopic Analysis 25 B.

Rad'ioiodine 26 V.

FISH " EDIBLE PORTIONS" DATA Gamma Isotopic Analysis 27 VI.

VEGETABLE PRODUCTS DATA Gamma Isotopic Analysis 28 VII. EPA CROSS-CHECK RESULTS-1992 29 I

I I

I GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Particulate Gross Beta These results are for particulate air samples duplicated by the MSDH and the Licensee which were analyzed for Gross Beta.

The Licensee's sampler is located at the Old Training Center (TC) 0.3 miles south of the GGNS and designated as AS-5 (Indicator).

The MSDH's comparable sampler is located at Arnold Acres (AA) 0.4 miles south of the GGNS.

The Lower Limit of Detection (LLD) specified in the contract for Gross Beta is 0.01 pCi/m3 Location Date MSDH Licensee I

(pci/m3)

(pCi/m3)

TC 12/31-1/06 0.036 I

AA 12/31-1/06 0.027 TC 1/06-1/14 0.030 AA 1/06-1/14 0.016 I

TC 1/14-1/21 0.010 AA 1/14-1/21 A

TC 1/21-1/28 0.017 AA 1/21-1/28 A

TC 1/28-2/04 0.031 AA 1/28-2/04 A

TC 2/04-2/11 0.014 I

AA 2/04-2/11 0.022 TC 2/11-2/18 0.011 AA 2/11-2/18 0.006 TC 2/18-2/25 0.019 I

AA 2/18-2/25 0.003 TC 2/25-3/03 0.023 AA 2/25-3/03 0.033 I

TC 3/03-3/10 0.016 AA 3/03-3/10 0.008 TC 3/10-3/17 0.010 I

AA 3/10-3/17 0.016 TC 3/17-3/24 0.018 AA 3/17-3/24 B

I TC 3/24-3/31 0.015 AA 3/24-3/31 0.005 I

g

I GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Particulate Gross Beta (cont'd)

Location Date MSDH Licensee (pCi/m8)

(pCi/m8)

I TC 3/31-4/07 0.018 AA 3/31-4/07 0.006 I

TC 4/07-4/14 0.013 AA 4/07-4/14 0.009 TC 4/14-4/21 0.011 AA 4/14-4/21 0.014 I

TC 4/21-4/28 0.012 AA 4/21-4/28 0.058 TC 4/28-5/05 0.018 I

AA 4/28-5/05 0.057 TC 5/05-5/12 0.018 AA 5/.5-5/12 0.024 I

TC Sj 2-5/19 0.027 AA 5/12-5/19 0.037 TC 5/19-5/26 0.010 AA 5/19-5/26

<0.01 I

TC 5/26-6/02 0.027 AA 5/26-6/02 0.014 TC 6/02-6/09 0.010 I

AA 6/02-6/09 0.031 TC 6/09-6/16 0.008 AA 6/09-6/16 0.014 TC

~

6/16-6/23 0.014 I

AA 6/16-6/23 0.055 TC 6/23-6/30 0.043-C AA 6/23-6/30 0.014 TC 6/30-7/07 0.018-D AA 6/30-7/07 0.047 TC 7/07-7/14 0.028 I

AA 7/07-7/14 0.027 TC 7/14-7/21 0.010 i

AA 7/14-7/21 0.024 TC 7/21-7/28 0.007 I

AA 7/21-7/28 0.022 TC 7/28-8/04 0.013 AA 7/28-8/04 0.043 3

I

I I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Particulate Gross Beta (cont'd)

Location Date MSDH Licenser I

(PCi/m3)

(pci/m*)

TC 8/04-8/11 0.016 AA 8/04-8/11 0.030 TC 8/11-8/18 0.009 I

AA 8/11-8/18 0.054 TC 8/18-8/25 0.019 AA 8/18-8/25 0.024 TC 8/25-9/01 0.010 I

AA 8/25-9/01 0.039 TC 9/01-9/09 0.011 AA 9/01-9/09 0.015 I

TC 9/09-9/15 0.017 AA 9/09-9/15 0.044 TC 9/15-9/22 0.006 AA 9/15-9/22 0.014 TC 9/22-9/29 0.010 AA 9/22-9/29 0.027 TC 9/29-10/06 0.011 I

AA 9/29-10/06 0.036 TC 10/06-10/13 0.014 AA 10/06-10/13 0.047 I

TC 10/13-10/20 0.015 AA 10/13-10/20 0.059 TC 10/20-10/27 0.018 AA

~

10/20-10/27 0.045 TC 10/27-11/03 0.017 AA 10/27-11/03 0.026 TC 11/03-11/10 0.010 I

AA 11/03-11/10 0.024 TC 11/10-11/17 0.010 AA 11/10-11/17 0.026 I

TC 11/17-11/24 0.008 AA 11/17-11/24 0.016 TC 11/24-12/01 0.029 AA 11/24-12/01 0.027 I

TC 12/01-12/08 0.020 AA 12/01-12/08 0.010 TC 12/08-12/15 0.020 4

I I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Particulate Gross Beta (cont'd)

Location Date MSDH Licensee (PCi/m2)

(pci/m2)

I AA 12/08-12/15 0.015 TC 12/15-12/22 0.025 I

AA 12/15-12/22 0.009 TC 12/22-12/29 0.016 AA 12/22-12/29 0.024 I

I I

I I

~

I A Motor out.

B Cattle blocked entrance.

C Blown fuse at-142.26-hours run time.

D No flow at collection.

I I

I I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Radiciodine These results are for charcoal canister air samples duplicated by the MSDH and the Licensee which were analyzed for radiciodine. The Licensee's sampler is located at the Old Training Center (TC) 0.3 miles south of the GGNS and designated as AS-5 I

(Indicator).

The MSDH's comparable sampler is located at Arnold Acres (AA) 0.4 miles south of the GGNS.

The Lower Limit of Detection (LLD) specified in the contract for Iodine-131 is 0.07 pCi/m8 I

Location Date MSDH Licensee (PCi/m3)

(pci/m )

s TC 12/31-1/06

<0.032 AA 12/31-1/06

<0.07 TC 1/06-1/14

<0.012 AA 1/06-1/14

<0.07 TC 1/14-1/21

<0.015 I

AA 1/14-1/21 A

TC 1/21-1/28

<0.015 AA 1/21-1/28 A

I TC 1/28-2/04

<0.011 AA 1/28-2/04 A

TC 2/04-2/11

<0.014 I

AA 2/04-2/11

<0.07 TC 2/11-2/18

<0.010 AA 2/11-2/18

<0.07 TC 2/18-2/25

<0.021 I

AA 2/18-2/25

<0.07 TC 2/25-3/03

<0.016 AA 2/25-3/03

<0.07 I

TC 3/03-3/10

<0.020 AA 3/03-3/10

<0.07 i

TC 3/10-3/17

<0.026 I

AA 3/10-3/17

<0.07 i

TC 3/17-3/24

<0.012 AA 3/17-3/24 B

TC 3/24-3/31

<0.024 AA 3/24-3/31

<0.07 I

6 I

I P

I GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Radiciodine (cont'd)

Location Date MSDH Licensee (PCi/m2)

(pci/m8)

TC 3/31-4/07

<0.028 AA 3/31-4/07

<0.07 I

TC 4/07-4/14

<0.016 AA 4/07-4/14

<0.07 TC 4/14-4/21

<0.010 AA 4/14-4/21

<0.07 I

TC 4/21-4/28

<0.011 AA 4/21-4/28

<0.07 TC 4/28-5/05

<0.029 I

AA 4/28-5/05

<0.07 TC 5/05-5/12

<0.015 AA 5/05-5/12

<0.07 I

TC 5/12-5/19

<0.018 AA 5/12-5/19

<0.07 TC 5/19-5/26

<0.015 AA 5/19-5/26

<0.07 I

TC 5/26-6/02

<0.020 AA 5/26-6/02

<0.07 TC 6/02-6/09

<0.016 I

AA 6/02-6/09

<0.07 TC 6/09-6/16

<0.013 AA 6/09-6/16

<0.07 TC 6/16-6/23

<0.013 I

AA 6/16-6/23

<0.07 TC 6/23-6/30

<0.012-C AA 6/23-6/30

<0.07 I

TC 6/30-7/07

<0.017-D AA 6/30-7/07

<0.07 TC 7/07-7/14

<0.016 I

AA 7/07-7/14

<0.07 TC 7/14-7/21

<0.015 AA

-7/14-7/21

<0.07 I

TC 7/21-7/28

<0.008 AA 7/21-7/28

<0.07 TC 7/28-8/04

<0.016 AA 7/28-8/04

<0.07 g

I t

r I

I r

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Radiciodine (cont'd)

Location Date MSDH Licensee (PCi/m8)

(pci/m8)

I TC 8/04-8/11

<0.024 AA 8/04-8/11

<0.07 TC 8/11-8/18

<0.025 I

AA 8/11-8/18

<0.07 TC 8/18-8/25

<0.018 AA 8/18-8/25

<0.07 TC 8/25-9/01

<0.016 I

AA 8/25-9/01

<0.07 TC 9/01-9/09

<0.009 AA 9/01-9/09

<0.07 I

TC 9/09-9/15

<0.030 AA 9/09-9/15

<0.07 TC 9/15-9/22

<0.030 I

AA 9/15-9/22

<0.07 TC 9/22-9/29

<0.019 AA 9/22-9/29

<0.07 TC 9/29-10/06

<0.009 I

AA 9/29-10/06

<0.07 TC 10/06-10/13

<0.013 AA 10/06-10/13

<0.07 I

TC 10/13-10/20

<0.018 AA 10/13-10/20

<0.07 TC 10/20-10/27

<0.032 AA

~

10/20-10/27

<0.07 I

TC 10/27-11/03

<0.024 AA 10/27-11/03

<0.07 TC 11/03-11/10

<0.019 AA 11/03-11/10

<0.07 TC 11/10-11/17

<0.009 AA 11/10-11/17

<0.07 I

TC 11/17-11/24

<0.008 AA 11/17-11/24

<0.07 TC

-11/24-12/01

<0.015 AA 11/24-12/01

<0.07 I

TC 12/01-12/08

<0.015 AA 12/01-12/08

<0.07 TC 12/08-12/15

<0.013 8

1

I I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Radioiodine (cont'd)

Location Date MSDH Licensee (pCi/m8)

(pCi/m8)

I AA 12/08-12/15

<0.07 TC 12/15-12/22

<0.025 I.

AA 12/15-12/22

<0.07 TC 12/22-12/29

<0.016 AA 12/22-12/29

<0.07 I

I I

I A Motor out.

B Cattle blocked entrance.

C Blown fuse at 142.26 hours3.009259e-4 days <br />0.00722 hours <br />4.298942e-5 weeks <br />9.893e-6 months <br /> run time.

D No flow at collection.

I

I I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

l Quarterly Composite (Gamma Isotopic)

These results are for particulate air samples, collected during a quarter, duplicated by the MSDH and the T,icensee which were analyzed as a composite for gamma emitters.

The Licensee's sampler is located at the Old Training Center (TC) 0.3 i

miles south of the GGNS and designated as AS-5 (Indicator).

The MSDH's sampler is located at Arnold Acres (AA) 0.4 miles south of I

the GGNS.

The Lower Limit of Detection (LLD) specified in the contract for Cs-134/-137 is 0.05 pCi/m8 and 0.06 pCi/m8 respectively.

Location Date MSDH Licensee (pCi/m3)

(pCi/m8)

TC 12/31-3/31

<0.01 AA 12/31-3/31

<0.01 I

TC 3/31-6/30

<0.01 AA 3/31-6/30

<0.01 TC 6/30-9/29

<0.01 AA 6/30-9/29

<0.01 I

TC 9/29-12/29

<0.01 AA 9/29-12/29

<0.01 I

. I

~

I I

I I

10 I

I I

i GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI

{

CY 1992 I

Particulate Gross Beta Control 3

These results are for particulate air samples taken 5

from control locations by the MSDH and the Licensee which were analyzed for Gross Beta.

The Licensee's sampler is located in Vicksburg (VB) 18 miles north of the GGNS and designated as AS-3 (Control).

The MSDH's sampler is located behind the Radiological Health Building (RH) in Jackson, 51 miles east northeast of the GGNS.

The Lower Limit of Detection (LLD) specified in the contract for Gross Beta is 0.01 pCi/m3 Location Date MSDH Licensee (pCi/m')

(pci/m8)

VB 12/31-1/06 0.026 i

RH 12/31-1/06 0.005 VB 1/06-1/14 0.023 i

RH 1/06-1/14 0.017 VB 1/14-1/21 0.011 RH 1/14-1/21 0.009 VB 1/21-1/28 0.022 RH 1/21-1/28 0.002 I

VB 1/28-2/04 0.063 RH 1/28-2/04 0.027 VB 2/04-2/11 0.014 I

RH 2/04-2/11 0.020 VB 2/11-2/18 0.016 RH 2/11-2/18 0.014 VB

~

2/18-2/25 0.019 RH 2/18-2/25 0.008 l

VB 2/25-3/03 0.026 RH 2/25-3/03 0.008 VB 3/03-3/10 0.017 RH 3/03-3/10 0.006 l

VB 3/10-3/17 0.012 I

RH 3/10-3/17 0.017 VB 3/17-3/24 0.017 RH

-3/17-3/24

-0.009 VB 3/24-3/31 0.016 I

RH 3/24-3/31 0.012 VB 3/31-4/07 0.022

.l I

I

I GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Particulate Gross Beta Control (cont'd)

Location Date MSDH Licensee (Pci/m8)

(pci/m2)

I RH 3/31-4/07 0.013 VB 4/07-4/14 0.012 I

RH 4/07-4/14 0.021 VB 4/14-4/21 0.013 RH 4/14-4/21 0.019 VB 4/21-4/28 0.013 I.

RH 4/21-4/28 0.030 VB 4/28-5/05 0.025 RH 4/28-5/05 0.035 VB 5/05-5/12 0.016 RH 5/05-5/12 0.019 VB 5/12-5/19 0.028 I

RH 5/12-5/19 0.021 VB 5/19-5/26 0.013 RH 5/19-5/26 0.018 VB 5/26-6/02 0.027 RH 5/26-6/02 0.002 VB 6/02-6/09 6.013 RH 6/02-6/09 0.019 I

VB 6/09-6/16 0.011 RH 6/09-6/16 0.001 VB 6/16-6/23 0.011-E RH 6/16-6/23 0.002 I

VB 6/23-6/30 0.034 RH 6/23-6/30 0.001 VB 6/30-7/07 0.015 I

RH 6/30-7/07 0.025 VB 7/07-7/14 0.027 RH 7/07-7/14 0.009 I

VB 7/14-7/21 0.008 RH 7/14-7/21 0.004 VB 7/21-7/28 0.012 I

RH 7/21-7/28 0.002 VB 7/28-8/04 0.008 RH 7/28-8/04 0.005 VB 8/04-8/11 0.013 12 I

I GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 t

Particulate Gross Beta Control (cont'd) 1 Location Date MSDH Licensee I

(PCi/ms)

(pCi/m2)

RH 8/04-8/11 A

VB 8/11-8/18 0.011 RH 8/11-8/18 A

I VB 8/18-8/25 0.013 RH 8/18-8/25 0.015 vB 8/25-9/01 0.011 RH 8/25-9/01 0.017 VB 9/01-9/09 0.009 RH 9/01-9/09 A

1 VB 9/09-9/15 0.017 RH 9/09-9/15 0.054 VB 9/15-9/22 0.004 RH 9/15-9/22 0.011 I

VB 9/22-9/29 0.011 RH 9/22-9/29 0.019 VB 9/29-10/06 0.017 RH 9/29-10/06 0.057 I

VB 10/06-10/13 0.015 RH 10/06-10/13 0.041 VB 10/13-10/20 0.016 I

RH 10/13-10/20 O.037 l

VB 10/20-10/27 0.023 RH 10/20-10/27 0.054 VB 10/27-11/03 0.017 I

RH 10/27-11/03 0.031 VB 11/03-11/10 0.009 RH 11/03-11/10 0.010 VB 11/10-11/17 0.008 RH 11/10-11/17 0.018 VB 11/17-11/24 0.006 I

RH 11/17-11/24 0.010 l

VB 11/24-12/01 0.012 RH

-11/24-12/01

-0.028 VB 12/01-12/08 0.009 I

RH 12/01-12/08 0.018 VB 12/08-12/15 0.009 RH 12/18-12/15 0.002 I

I 9

I GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI 1

CY 1992 I

Particulate Gross Beta Control (cont'd) 4 Location Date MSDH Licensee (pCi/m8)

(pCi/m8)

I VB 12/15-12/22 0.014 RH 12/15-12/22 0.013 I

VB 12/22-12/29 0.014 RH 12/22-12/29 0.017 I

,I I

~

I A Motor out.

E Pump failure at 82.34 hours3.935185e-4 days <br />0.00944 hours <br />5.621693e-5 weeks <br />1.2937e-5 months <br /> run time.

14

I I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Radiciodine Control These results are for charcoal canister air samples I

taken from control locations by the MSDH and the Licensee which were analyzed for radiciodine.

The Licensee's sampler is located in Vicksburg (VB) 18 miles north of the GGNS and designated as AS-3 I

(Control).

The MSDH's sampler is located behind the Radiological Health Building (RH) in Jackson, 51 miles east northeast of the GGNS. The Lower Limit of Detection (LLD) specified in the contract for Iodine-131 is 0.07 pCi/m2 Location Date MSDH Licensee (pCi/m2)

(pCi/m2)

VB 12/31-1/06

<0.032 i

I RH 12/31-1/06

<0.07 VB 1/06-1/14

<0.012 RH 1/06-1/14

<0.07 VB 1/14-1/21

<0.015 RH 1/14-1/21

<0.07 VB 1/21-1/28

<0.015 f

RH 1/21-1/28

<0.07 I

VB 1/28-2/04

<0.011 RH 1/28-2/04

<0.07 L

VB 2/04-2/11

<0.014 I

RH 2/04-2/11

<0.07 VB 2/11-2/18

<0.010 Pi VP

~

2/11-2/18

<0.07 2/18-2/25

<0.021 I

R 2/18-2/25

<0.07 VB 2/25-3/03

<0.016 RH 2/25-3/03

<0.07 VB 3/03-3/10

<0.020 i

RH 3/03-3/10

<0.07 VB 3/10-3/17

<0.026 RH 3/10-3/17

<0.07 VB 3/17-3/24

<0.012 RH 3/17-3/24

<0.07 VB 3/24-3/31

<0.024 I

RH 3/24-3/31

<0.07 15

I I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Radiciodine Control (cont'd)

Location Date MSDH Licensee (pCi/m3)

(pCi/m3)

VB 3/31-4/07

<0.028 RH 3/31-4/07

<0.07 V9 4/07-4/14

<0.016 I

RH 4/07-4/14

<0.07 VB 4/14-4/21

<0.010 RH 4/14-4/21

<0.07 VB 4/21-4/28

<0.011 RH 4/21-4/28

<0.07 VB 4/28-5/05

<0.029 RH 4/28-5/05

<0.07 I

VB 5/05-5/12

<0.015 RH 5/05-5/12

<0.07 VB 5/12-5/19

<0.018 I

RH 5/12-5/19

<0.07 VB 5/19-5/26

<0.015 RH 5/19-5/26

<0.07 VB 5/26-6/02

<0.020 RH 5/26-6/02

<0.07 VB 6/02-6/09

i.016 RH 6/02-6/09

<0.07 I

VB 6/09-6/16

<0.013 RH 6/09-6/16

<0.07 VB 6/16-6/23

<0.013-E RH 6/16-6/23

<0.07 I

VB 6/23-6/30

<0.012 RH 6/23-6/30

<0.07 VB 6/30-7/07

<0.017 I

RH 6/30-7/07

<0.07 VB 7/07-7/14

<0.016 RH 7/07-7/14

<0.07 VB 7/14-7/21

<0.015 RH 7/14-7/21

<0.07 VL 7/21-7/28

<0.008 RH 7/21-7/28

<0.07 I

VB 7/28-8/04

<0.016 RH 7/28-8/04

<0.07 VB 8/04-8/11

<0.024 I

I

I GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Radioiodine Control (cont'd)

Location Date MSDH Licensee (PCi/m3)

(pci/m8)

RH 8/04-8/11 A

VB 8/11-8/18

<0.025 RH 8/11-8/18 A

VB 8/18-8/25

<0.018 RH 8/18-8/25

<0.07 VB 8/25-9/01

<0.016 I

RH 8/25-9/01

<0.07 VB 9/01-9/09

<0.009 RH 9/01-9/09 A

I VB 9/09-9/15

<0.030 RH 9/09-9/15

<0.07 l

VB 9/15-9/22

<0.030 I

RH 9/15-9/22

<0.07 VB 9/22-9/29

<0 019 RH 9/22-9/29

<0.07 VB 9/29-10/06

<0.009 RH 9/29-10/06

<0.07 VB 10/06-10/13

<0.013 RH 10/06-10/13

<0.07 I

VB 10/13-10/20

<0.016 RH 10/13-10/20

<0.07 VB 10/20-10/27

<0.032 RH 10/20-10/27

<0.07 t

VB 10/27-11/03

<0.024 i

RH 10/27-11/03

<0.07 VB 11/03-11/10

<0.019 RH 11/03-11/10

<0.07 1

(

VB 11/10-11/17

<0.009 RH 11/10-11/17

<0.07 I

VB 11/17-11/24

<0.008 I

RH 11/17-11/24

<0.07 VB 11/24-12/01

<0.015 RH 11/24-12/01

<0.07 I

+

VB 12/01-12/08

<0.015 RH 12/01-12/08

<0.07

{

VB 12/08-12/15

<0.013

~

I 17 I

i

I I-GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Radioiodine Control (cont'd)

Location Date MSDH Licensee (PCi/m8)

(pCi/m*)

I RH 12/08-12/15

<0.07 VB 12/15-12/22

<0.025 I

RH 12/15-12/22

<0.07 VB 12/22-12/29

<0.016 RH 12/22-12/29

<0.07 I

I I

I

~

I A Motor out.

E Pump failure at 82.34 hours3.935185e-4 days <br />0.00944 hours <br />5.621693e-5 weeks <br />1.2937e-5 months <br /> run time.

I 18 c

I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 f

Quarterly Composite (Gamma Isotopic) Control i

The e results are for particulate air samples, collected during a quarter, taken from control locations by the MSDH and the Licensee which were analyzed as a composite for gross gamma emitters.

The Licensee's sampler is located in Vicksburg I

(VB) 18 miles north of the GGNS and designated as AS-3 (Control).

The MSDH's sampler is located behind the Radiological Health Building (RH) in Jackson, 51 miles east northeast of the GGNS.

The I

Lower Limit of Detection (LLD) specified in the contract for Cs-134/-137 is 0.05 pCi/m8 and 0.06 pCi/m8, respectively.

Location Date MSDH Licensee (pCi/m8)

(pCi/m8)

I VB 12/31-3/31

<0.01 RH 12/31-3/31

<0.01 VB 3/31-6/30

<0.01 RH 3/31-6/30

<0.01 VB 6/30-9/29

<0.01 RH 6/30-9/29

<0.01 VB 9/29-12/29

<0.01 I

RH 9/29-12/29

<0.01 g

~

I I

19 I

I I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSIiSIPPI CY 1992 Gamma Isotopic Analys.ls These results are for river water samples split with the Licensee and analyzed by Gamma Isotopic analysis.

The Mississippi River Water Upstream (MRU) sample location is 2 miles north northwest of the GGNS (Control). The Mississippi River Water I

Downstream (MRD) sample location is 2 miles west southwest of the GGNS (Indicator). The Licensee's Lower Limits of Detection (LLD),

from their Technical Specifications, are:

Cs-137: 18 pCi/1; Mn-54, Co-58, Co-60, Nb-95, Cs-134, La-140: 15 pCi/1; Fe-59, Zn-65, Zr-95: 30 pCi/1; Ba-140: 60 pCi/1.

The MSDH's LLD are: Mn-54, Cs-134: 6 pCi/1; Ba/La-140, Co-58/-60, Nb-95: 15 pCi/1; Cs-137: 18 pCi/1; Fe-59, Zn-65, Zr-95: 25 pCi/1, which are equal to or less I

than the contract specification.

The data for these radionuclides are reported as less than LLD in each case.

I Location Date MSDH Licensee i

(pCi/1)

(pCi/l)

MRU JAN 02, 1992

<LLD

<LLD MRU FEB 04, 1992

<LLD

<LLD MRU MAR 03, 1992

<LLD

<LLD MRU-F MAR 03, 1992

<LLD MRU APR 07. 1992

<LLD

<LLD MRU MAY G.,

1992

<LLD

<LLD I

MRU JUN 02, 1992

<LLD

<LLD MRU-F JUN 02, 1992

<LLD MRU JUL 07, 1992

<LLD

<LLD MRU AUG 04, 1992

<LLD

<LLD I

MRU SEP 01, 1992

<LLD

<LLD MRU OCT 06, 1992

<LLD

<LLD MRU NOV 03, 1992

<LLD

<LLD MRU DEC 01, 1992

<LLD

<LLD MRD JAN 02, 1992

<LLD

<LLD MRD FEB 04, 1992

<LLD

<LLD MRD MAR 03, 1992

<LLD

<LLD I

MRD-F MAR 03, 1992

<LLD MRD APR 07, 1992

<LLD

<LLD MRD MAY 05, 1992

<LLD

<LLD I

MRD JUN 02, 1992

<LLD

<LLD MRD-F JUN 02, 1992

<LLD 20 I

I GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Garana Isotopic Analysis (cont'd)

Location Date MSDH Licensee (PCi/1)

(pci/l)

MRD JUL 07, 1992

<LLD

<LLD MRD AUG 04, 1992

<LLD

<LLD I

MRD SEP 01, 1992

<LLD

<LLD MRD OCT 06, 1992

<LLD

<LLD MRD NOV 03, 1992

<LLD

<LLD MRD DEC 01, 1992

<LLD wLD I

i I

I I

I I

r I

F Duplicate sample for Licensee Quality Control program, t

I 21

I I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Tritium These results are for river water samples split by the MSDH and the Licensee and analyzed for tritium using liquid scintillation analysis. The Mississippi River Water Upstream (MRU) sample location is 2 miles north northwest of the GGNS (Control).

_I The Mississippi River Water Downstream (MRD) sample location is 2 t

miles west southwest of the GGNS (Indicator).

Licensee's Lower Limit of Detection (LLD) for tritium (H-3) as required by their Technical Specifications is 2000 pCi/1.

The Licensee's LLD is I

computed individually for each sample and indicated by "<" below.

The MSDH's LLD is 330 pCi/1.

The contract specifications are 1000 t

pCi/1 for drinking water, and 2000 pCi/l for other water samples.

I Licensee's results are a quarterly composite of the preceding three months.

The MSDH tritium analyses are performed monthly.

I Location Date MSDH Licensee (PCi/1)

(pci/l)

MRU JAN 02, 1992

<330 G

I MRU FEB 04, 1992

<330 G

MRU MAR 03, 1992

<330

<600 MRU-F MAR 03, 1092

<600 MRU APR 07, 1992

<330 G

MRU MAY 05, 1992

<330 G

MRU JUN 02, 1992

<330

<610 I

MRU-F JUN 02, 1992

<610 MRU JUL 07, 1992

<330 G

MRU AUG 04, 1992

<330 G

MRU SEP 01, 1992

<330

<510 I

MRU OCT 06, 1992

<330 G

MRU NOV 03, 1992

<330 G

MRU DEC 01, 1992

<330

<480 MRU-F DEC 01, 1992

<480 MRD JAN 02, 1992

<330 G

MRD FEB 04, 1992

<330 G

I MRD MAR 03, 1992

<330

<600 MRD-F MAR 03, 1992

<600 MRD APR 07, 1992

<330 G

MRD MAY 05, 1992

<330 G

MRD JUN 02, 1992

<330

<610 MRD-F JUN 02, 1992

<610 i

I l

22 t

I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Tritium (cont'd)

Location Date MSDH Licensee (pCi/1)

(pCi/1).

MRD JUL 07, 1992

<330 G

MRD AUG 04, 1992

<330 G

MRD SEP 01, 1992

<330

<510-MRD OCT 06, 1992

<330 G

MRD NOV 03, 1992

<330 G

MRD DEC 01, 1992

<330

<480 MRD-F DEC 01, 1992

<480 I

I I

~

a F Duplicate sample for Licensee Quality Control program.

G Composite sample, results below.

23

I I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Gamma Isotopic Analysis These results are for river sediment samples I

collected in duplicate and analyzed by Gamma Isotopic methods.

The MSDH designates their control as the Mississippi River Upstream (MRU) and their indicator as the Mississippi River Downstream (MRD).

The Licensee's designation for control is the Mississippi River Upstream, (SEDCONT) and indicator is Hamilton Lake (SEDHAM).

The controls are both located approximately 2 miles north northwest I

of GGNS. The indicators are located approximately 2 miles west.

southwest of the GGNS.

The Licensee's Lower Limits of Detection (LLD) for sediment samples are:

Mn-54, Co-58, Co-60, Cs-134: 150 pCi/kg (dry) and Cs-137: 180 pCi/kg (dry); the Cs-134/-137 LLD are as specified in their Technical Specifications.

The contract LLD specified for Cs-134/-137 is 150 pCi/kg and 180 pCi/kg respectively.

~9 cation Date MSDH Licensee (pCi/kg)

(pCi/kg)

MRU 6/09/92

<LLD SEDCONT 6/09/92

<LLD I

SEDCONT-F 6/09/92

<LLD MRD 6/09/92

<LLD SEDHAM 6/09/92

<LLD I

SEDHAM-F 6/09/92

<LLD MRU 12/11/92

<LLD SEDCONT 12/11/92

<LLD SEDCONT-F ~

12/11/92

<LLD I

MRD 12/11/92

<LLD SEDHAM 12/11/92

<LLD SEDHAM-F 12/11/92

<LLD I

F Duplicate sample for Licensee Quality Control program.

I I

I

I I

GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Gamma Isotopic Analysis These results are for duplicate Alcorn Dairy milk samples which the MSDH and the Licensee analyzed by Gamma Isotopic methcds.

Alcorn Dairy is located eleven miles southwest of the GGNS.

Samples are labeled RH for Radiological Health and GG for Licensee. The Licensee's Lower Limits of Detection for Milk are as follows:

Cs-134, La-140: 15 pCi/1; Cs-137: 18 pCi/1; Ba-140: 60 pCi/1.

The Licensee's LLD are in accordance with their Technical

'l Specifications.

The contract LLD specified for Cs-134/-137 and E

Ba/La-140 is 15, 18, 60 and 15 pCi/l respectively.

Sample Date MSDH Licensee (pCi/1)

(pCi/l)

RH 6/10/92

<15 GG 6/10/92

<15 GG-F 6/10/92

<15 RH 12/09/92

<15 GG 12/09/92

<15 I

I

~

I I

b F Duplicate sample for Licensee Quality Control program.

25 1

l

P GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 Radioiodine These results are for duplicate Alcorn Dairy milk I

samples which the MSDH and the Licensee analyzti for radioiodine by Gamma Isotopic methods.

Alcorn Dairy is located eleven miles southwest of the GGNS.

Samples are labeled RH for Radiological I

Health and GG for Licensee.

The MSDH's Lower Limit of Detection for iodine in milk is 1 pCi/1, as specified in the contract.

Sample Date MSDH Licensee (pci/1)

(pci/1)

RH 6/10/92

<1 GG 6/10/92

<0.2 GG-F 6/10/92

<0.2 I

RH 12/09/92

<1 GG 12/09/92

<0,3 I

I I

F Duplicate sample for Licensee cuality Control program.

I g

2e

I GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Gamma Isotopic Analysis I

the Mississippi River Upstream (MRU) approximately 2 miles north These results are for edible fish samples taken from northwest of the GGNS and the Mississippi River Downstream (MRD) approximately 2 miles west southwest of the GGNS.

Each sample was I

analyzed by Gamma Isotopic methods. The Licensee's Lower Limits of Detection are:

Mn-54, Co-58, Co-60, Cs-134: 130 pCi/kg; Cs-137:

150 pCi/kg; and Fe-59, Zn-65: 260 pCi/kg.

The LLD used by the I

Licensee in these analyses are in accordance with their Technical Specifications.

The LLD specified in the MSDH contract are:

Mn-54, Co-58/60, Cs-134:

130 pCi/kg; Cs-137 :

150 pCi/kg; Fe-59, Zn-65:

260 pCi/kg.

Location Date MSDH Licensee (PCi/kg)

(pCi/kg)

MRU 6/28/92

<LLD

<LLD MRU-F 6/28/92

<LLD I

MRD 6/28/92

<LLD

<LLD MRD-F 6/28/92

<LLD MRU 12/12/92

<LLD

<LLD MRD 12/12/92

<LLD

<LLD I

I

~

1 I

F Duplicate Sample for Licensee Quality Control program.

1 I

g 27 I

I I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

Gamma Isotopic Analysis I

These results are for vegetation samples taken from Sectors R, K, and J.

These samples were analyzed by Gamma Isotopic methods. The Licensee's Lower Limits of Detection are:

I-131, Cs-134: 60 pCi/kg; and Cs-137: 80 pCi/kg, as specified in their Technical Specifications. The contract specifications for the MSDH are:

I-131, Cs-134: 60 pCi/kg each; and Cs-137: 80 pCi/kg.

Vegetable Sector Date MSDH Licensee (PCi/kg)

(pci/kg)

Collards J

1/08/92

<60

<60 Rape K

1/08/92

<60

<60 Collards R

1/08/92

<60

<60 Swuss Chard J

4/13/92

<60

<60

?

Swiss Chard K

4/13/92

<60

<60 Collards R

4/13/92

<60

<60 Swiss Chard J

7/14/92

<60

<60 Collards K

7/14/92

<60

<60 Swiss Chard ^

R 7/14/92

<60

<60 Swiss Chard J

10/13/92

<60

<60 Cabbage K

10/13/92

<60

<60 Swiss Chard R

10/13/92

<60

<60

.g 1

I I

I

I I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 I

EPA Cross-Check Results--1992 All values reported in pCi/l unless otherwise indicated.

I January Strontium in Water Strontium 89 45, 45, 46 51i8.7 Strontium 90 22, 22, 22 2018.7 Gross Alpha / Beta in Water I

Alpha 25, 25, 26 30 13.9 Beta 34, 34, 35 30 8.7 I

February Iodine in Water Iodine 59, 59, 60 59 10.4 Gamma in Water Cobalt 60 40, 40, 41 40 8.7 Zinc 65 150, 150, 150 148i26 I

Ruthenium 106 196, 197, 197 203 34.7 Cesium 134 28, 28, 29 3118.7 Cesium 137 52, 52, 52 49i8.7 Barium 133 72, 73, 73 76 13.9 Tr,itium in Water I

Tritium 7526, 7534, 7542 79041790 March Radium in Water Radium 226 9.4, 9.4, 9.5 10.li2.6 Radium 228 20.9, 20.9, 20.5 15.516.8 I

Uranium in Water Uranium 20.0, 20.2, 20.3 25.3i5.2 Air Filter I

Alpha 7,

7, 7

7 8.7-H Beta 39, 39, 39 41 8.7-H Strontium 90 10, 11, 11 15 8.7-H Cesium 137 8,

8, 9

10i8.7-H 29 I

I GRAND GULF NUCLEAR STATION CLAIBORNE COUNTY, MISSISSIPPI CY 1992 i

I EPA Cross-Check Results (cont'd)

I Reported Known April Performance Evaluation i

Intercomparison Study i

Alpha 31, 32, 33 40 17.3 Radium 226 15.1, 15.2, 15.3 14.913.8 i

Radium 228 17.6, 17.9, 17.7 14.0i6.1 Uranium 4.5, 4.7, 4.8 4.0 5.2 I

Beta 113, 113, 114 140136.4 Strontium 89 10, 10, 10 15i8.7 Strontium 90 14, 15, 15 17i8.7 Cesium 134 24, 24, 24 24i8.7 Cesium 137 26, 26, 26 2218.7 Cobalt 60 57, 57, 57 56i8.7 I

Radionuclides in Milk Strontium 89 12, 13, 13 3818.7 Strontium 90 25, 26, 26 29 8.7 I

Iodine 131 71, 71, 71 78i10.4 Cesium 137 42, 42, 42 39 8.7 Potassium 1932, 1947, 1956 1710il50 May strontium in Water Strontium 89 24, 24, 24 29 8.7 Strontium 90 6,

6, 6

818.7 Gross Alpha / Beta in Water I

Alpha 9,

11, 12 15i8.7 Beta 43, 43, 44 44 8.7 June Radionuclides in Water Cobalt 60 20, 20, 20 20 8.7 Zinc 65 105, 105, 105 99 17.3 Ruthenium 106 125, 128, 128 141124.3

.I Barium 133 99, 100, 101 98 17.3 Cesium 134 15, 15, 16 15i8.7

-Cesium 137 15, 16, 16 15 8.7 Tritium in Water Tritium 2087, 2088, 2090 2125 347 l

I.

30 I

I GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 EPA Cross-Check Results (cont'd)

I Reported Known July Radium in Water Radium 226 22.6, 22.6, 22.7 24.9 6.4 Radium 228 15.2, 15.2, 15.3 16.7i7.3 Uranium in Water Uranium 4.4, 4.5, 4.7 4 5.2 August Iodine in Water Iodine 41, 42, 42 45i10.4 Air Filter Alpha 25, 25, 25 30i13.9-H Beta 74, 74, 74 69 17.3-H I

Strontium 90 17, 18, 18 2518.7-H Cesium 137 20, 20, 21 18i8.7-H September Gross Alpha / Beta in Water I

Alpha 26, 26, 26 45 19.1 Beta 46, 48, 48 50 8.6

~

Strontium in Water I

Strontium 89 18, 18, 19 20i8.7 Strontium 90 15, 15, 15 15i8.7 Radionuclides in Milk i

Strontium 89 4,

5, 5

15 8.7 I

Strontium 90 7,

7, 8

15 8.7 Iodine 131 98, 99, 100 100117.3

-Potassium 1770,-1770,1770 1750 152 Cesium 137 18, 18, 18 15 8.7 I

I 31 I

I I

GRAND GULF NUCLEAR STATION I

CLAIBORNE COUNTY, MISSISSIPPI CY 1992 EPA Cross-Check Results (cont'd) g Reported Known I

october Radionuclides in Water Cobalt 60 10, 10, 10 10i8.7 I

Zinc 65 145, 145, 145 148 26 Ruthenium 106 153, 154, 154 175131.2 Cesium 134 7,

7, 8

818.7 I

Cesium 137 8,

8, 8

8 8.7 Barium 133 65, 65, 65 74 12 Tritium in Water I

Tritium 5447, 5479, 5515 5962 1034 Performance Evaluation I

Intercomparison Study Alpha 35, 35, 36 29il2.1 Radium 226 6.6, 6.5, 6.5 7.4 1.92 I

Radium 228 9.9, 9.9, 9.8 10.0i4.3 Uranium 10.5,10.5,10.5 10.215.2 Beta 52, 52, 52 53 17.3 Strontium 89 7,

7, 7

Bi8.7 Strontium 90 11, 12, 12 1018.7 Cobalt 60 13, 13, 13 15i8.7 Cesium 134 5,

5, 5

Si8.7 Cesium 137 8,

8, 8

818.7, November I

Radium in Water Ra "

'226 6.3, 6.3, 6.4 7.511.9 Ra:

228 5.5, 5.6, 5.6 5.011.3 Uranium in Water Uranium 16, 16.1, 16.2 15.2i5.2 I

I k

.l H

values are reported as pCi/ filter.

I I

--