UNITED STATES NUCLEAR REGULATORY COMMISSION n
~ k..... [j _
i*
w Asm NGTON, D. C. 20$55 j
February 16, 1990 Dockets Nos. 50-321 50-366 l
Mr. W. G. Hairston, III l
Senior Vice President Nuclear Operations Georgia Power Company P.O. Box 1295 Birmingham, Alabana 35201
Dear Mr. Hairston:
SUBJECT:
EDWIN I. HATCH NUCLEAR PLANT, UNITS 1 AND'2, RESPONSE TO GENERIC LETTER.88-01,("NRC POSITION ON IGSCC IN BWR AUSTENITIC STAINLE STEEL PIPING TACS N05. 69138 AND 69139) f_ -
The hRC staff.has completed its review of the EcWin I. Hatch Nuclear Plant, Units I and 2, response to' Generic Letter (GL) 88-01, *hRC Position on IGSCL in BWR Austenttic Stainless Steel Piping," as 3roviced in the Georgia Power Company (GPC) letters of June 30, 1968, Septem>er 27, 1908, and October 19, 1988.
The staff finas the GPC response to GL 88-01 acceptable with two exceptions that are discussed in the encicsed Safety Evaluation and in Sections 2.8 and 3.3 of the Technicci Evaluation Report for each Hatch unit.
Specifically, the two GPC positions that are not in confornance with GL 88-016re the position to overage 4-hour interval reactor coolant system (RCS) leakage neasurenents over a 24-hour time period and the position to not incorporate a change to the Technical Specifications (TSs) stating that Inservice Inspection (ISI) shall be in accordance with GL 88-01.
With regard to RCS leakage monitoring, the staff has concluded that taking RCS leakage measurements every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> creates an unnecessary administrative hardship.
Thus, RCS leakage measurements may be taken every 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />; however,
'these leakage measurenents may not be averaged over a 24-hour time frane.
It-is requested that you submit TS change requests to incorporate in the existing TSs both the RCS leakage mon-itoring requirenents and the requirerent to perform ISI in accordance with GL 88-01, further, these requirements should be incorporated in the revised TSs developeo in accordance with the Technical Specification Improveuent Program.
With the issuance of this Safety Evaluation, GPC no longer is required to submit IGSCC inspection plans for each future outage at Hatch Units 1 and 2.
The. inspection plans were submitted in the GPC response to GL 88-01, and the r6quirements of GL 88-01 will be incorporated into the Inproved TSs for Hatch Units 1 and 2.
However, if fitws are found that do not meet the criteria of Paragraph IWB-3500 of Section XI of the ASME Code, for continued operation withcut evaluation, the evaluations and plans for repair of the subject fisws should be submitted to the NP.C for review prior to startup.
9003210067 900216 PDR ADOCK 05000321 p
FDC i
(
{
$\\
e et
-2 i
1 Please call me ~if you have any questions.
l Sincerely, P
/s/
Lawrence P. Crocker, Project Manager Project Directorate 113 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation
. DISTRIBUTION:
- seDecketfFile)DL PDII.3 Rdg. File i
DMatt hews
[
RIngram LCrocker RClark N
i r
l l
Y i
f
- See previous concurren OFC :LA:PD11 3*
- PM:PDIIx W. :Du 14 3
.:.............:..... 9 t W.:. A, t4.....:............:............:...,........:.........
NAME :RIngram
- LCroc ker: s1 :
thews
.:............:............:....f.......:............:..-..........:............:.........
j!DATE801/22/90
- 01/12/90
- 0[/\\b/90 L
0FFICIAL RECORD COPY L
Document Name:
HATCHGL 8801
~y 3
Mr. W. G. Hairston, 111 Edwin 1. Hatch Nuclear Plant, Georgia Power Company Units Nos. I and 2 cc:
Shaw, Pittman, Potts and Trowbridge Mr. R. P. Mcdonald 2300 N Street, N. W.
Executive Vice President -
Washington, D.C.
20037 Nuclear Operations Georgia Power Company Mr. J. T. Beckham P.O. Box 1295 Vice President - Plant Hatch Birmingham, Alabama 35201 Georgia Power Company t
P.O. Cox 1295 Mr. Alan R. Herdt, Chief Birrding!;am, Alabama 35201 Project Branch #3 U.S. Nuclear Regulatory Comission Mr. S. J. Bethay 101 Parietta Street, NW, Suite 2900 Manager Licensing - Hatch Atlanta, Georgia 30323 Georgia Power Company P.O. Box 1295 Dirmingham, Alabama 35201 Mr. H. C. Nix General Manager, Nuclear P16nt Georgia Power Company Route 1, Box 439 Baxley, Georgia 31513 Resident Inspector U.S. Nuclear Regulatory Commission Route 1, Box 725 Baxley, Georgia 31513 Regional Administrator, Region.11 U.S. Nuclear Regulatory Commission 101 Marietta Street, Suite 2900 Atlanta, Georgia 30323 Mr. Charles H. Badger Office of Planning and Budget Room 610 270 Washington Street, S.W.
Atlanta, Georgia 30334 Mr. J. Leonard Ledbetter, Director Environmental Protection Division Departner.t of Natural Resources 205 Butler Street, S.E.,
Suite 1252 Atlanta, Georgia 30334 Chairman Appling County Comissioners County Courthouse Baxley, Georgia 31513
-