Grants Permission to Use ASME Code Case N-461 During Spring 1990 Refueling Outage for Calibr Blocks,Thickness Measurements & Weld Joint Contours & Ultrasonic Reflectors, Per 891016 Request
ML20006B009
Person / Time
Site: Hatch  
Issue date: 01/22/1990
From: Crocker L
Office of Nuclear Reactor Regulation
To: Hairston W
GEORGIA POWER CO.
References
TAC-69138, TAC-69139, NUDOCS 9001310171
Download: ML20006B009 (3)


Text

-

=!

o,.

' AH4g I

'g UNITED WTATES o

g NUCLEAR REGULATORY COMMISSION 5

a wAssiwoToN, D. C. 20666 r

/

January 22, 1990 1

Docket Nos. 50-321 l

50-366 Mr. W. G. Hairston, III Senior Vice President -

Nuclear Operations Georgia Power Company P.O. Box 1295 Birmingham, Alabama 35201

Dear Mr. Hairston:

SUBJECT:

USEOFASMECODECASEN-461(TACS69138AND69139)

By letter of October 16, 1989, Georgia Power Company requested permission to use ASME Code Case N-461 in meeting the requirements of.the 1980 Section.XI.

Code, with Addenda through Winter 1981, for calibration blocks to be used J

during the Spring 1990 refueling outage for Hatch Unit 1.

Following its initial review of the GPC request, the NRC staff had a number of questions-i regarding the proposed use of Code Case N-461. These were discussed via telephone with your representatives. The additional information' requested by the staff was furnished.by GPC letter dated December 12, 1989.

Pending final review and evaluation by the NRC staff of Code Case N-461, it appears that the code case will be approved for generic use with supple-mental requirements as follows:

1.

The calibration blocks requiring thickness tolerance allowed by the Code Case must be uniquely identified in the 10-Year Inservice Inspection Plan and in the current ISI Outage Plan, 2.

Thickness measurements and weld joint contours of the pipe / component must be known and used by the inspector conducting the UT.

examination.

l~

3.

All ultrasonic reflectors, 50% DAC and above, must be recorded and l

their position in the weld joint plotted to determine whether the-reflectors are relevant indications. Plotting may be by hand-calculation or by computer so long as-the variables are known and accounted for.

. Permission is hereby granted, prior to possible generic approval by the NRC of Code Case N-461, for you to use Code Case N-461, subject to the above supplemental requirements, for the calibration blocks used during the Spring-1990 refueling outage for Hatch Unit 1.

j q

900131 g $$$ h21 DR A

PDC p pl_

.'l(O

Mr.'W. G. Hairston

-2 Please call me if you have any questions.

Sincerely, l

/s/

Lawrence P. Crocker, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II-Office of Nuclear Reactor Regulation cc: See next page DISTRIBUTION C Na4 NRC'PDR I

Local PDR l

PDII-3 Reading S. Varga 14-E.4 G. Lainas 14-H-3 D. Matthews 14-H.25 R. Ingram 14 H-25 L...Crocker 14-H-25 OGC(Forinform.Only) 15-B.18 E. Jordan MNBB-3302 J. Coley RII G. Mi11raan NS217B CY. Cheng 9-H-15 R. Hermann 9-H.15 ACRS(10)

P-315 5

[HatchPlantFile]

f 0FFICIAL RECORD COPY Document Name: HAIRSTON LTR 1/17 I

,.....:......b....:../:PAHf-3

0FC
LA:PDII.3
PM fLp....:.../EMTc(f:dMAtthews
NRR
1 :

-3

LCrocker:cb :CYCh g-

!NAME :RIngra

/41/90

]/g'))90 iDATE': I /f190
/ /A)/90 1.

i

,I

W.'W. G. Hairston, III Edwin I. Hatch Nuclear Plant, Georgia Power Company Units Nos. I and 2 cc:

Shaw, Pittman, Potts and Trowbridge Mr. R. P. Mcdonald 2300 N Street, N. W.

Executive Vice President -

Washington, D.C.

20037 Nuclear Operations Georgia Power Company Mr. J. T. Beckham P.O. Box 1295 Vice President - Plant Hatch Birmingham, Alabama 35201 Georgia Power Comparty i

P.O. Box 1295 Mr. Alan R. Herdt, Chief Birmingham, Alabama 35201 Project Branch #3 U.S. Nuclear Regulatory Commission Mr. S. J. Bethay 101 Marietta Street, NW, Suite 2900 Manager Licensing - Hatch Atlanta, Georgia 30323 Georgia Power Company P.O. Box 1295 Birmingham, Alabama 35201 Mr. H. C. Nix General Manager, Nuclear Plant Georgia Power Company Route 1 Box 439 Baxley, Georgia 31513 Resident inspector l'.S. Nuclear Regulatory Commission Route 1, Box 725 Baxley, Georgia 31513 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, Suite 2900 Atlanta, Georgia 30323 Mr. Charles H. Badger i

Office of Planning and Budget Room 610 270 Washington Street, S.W.

Atlanta, Georgia 30334 Mr. J. Leonard Ledbetter, Director Environmental Protection Division Department of Natural Resources

)

205 Butler Street, S.E.,

Suite 1252 Atlanta, Georgia 30334 Chairman Appling County Conmissioners County Courthouse Baxley, Georgia 31513

.