Tech Spec Change Request 5.7,Revision 1,to Amend License DPR-72 Requesting Relief from Provisions of Tech Spec 3.0.4 Under Certain Specified Conditions
ML20032C233
Person / Time
Site: Crystal River 
Issue date: 10/30/1981
From:
FLORIDA POWER CORP.
To:
Shared Package
ML20032C231 List:
References
TAC-46970, TAC-49540, NUDOCS 8111090532
Download: ML20032C233 (1)


Text

._

I Revision 1 10/30/81 r

TECHNICAL SPECIFICATION CHANGE REQUEST N0. 57 (APPENDIX A)

Replace pages 3/4 6-15, 3/4 6-17, 3/4 6-18, 3/4 6-19, 3/4 6-20, 3/4 6-21, and 3/4 6-21a with the attached revised pages 3/4 6-15, 3/4 6-17, 3/4 6-18, 3/4 6-19, 3/4 6-20, 3/4 6-21, and 3/4 6-21a.

Proposed Change Add ACTION Statement "e" to read: "The provisions of Specification 3.0.4 are not applicable to those valves in Table 3.6-1 annotated by asterisks."

Asterisks have been added to appropriate valves in Table 3.6-1.

Reason for Proposed Change ACTION "e" has been proposed for Specification 3.6.3.1 for valves that are performing their post-containment isolation function, but are inoperable and ACTION Statement "b" or "c" is in effect.

Since these valves are already in their post-containment isolation configuration, they neither perform an emergency core cooling function, nor offer any hindrance to normal plant operations while shut or isolated. There is no reason to restrain the entry into other OPERATIONAL MODES.

Therefore, the exception to the provisions of Specification 3.0.4 is proposed.

Safety Analysis of the Proposed Action Entry into an OPERATIONAL MODE is restricted in that the conditions of the Limiting Conditions for Operation (LCO) must be met without reliance on ACTION statements unless specifically excepted.

Specific exceptions can be granted when the ACTION statement places the unit in a condition which is equivalent to meeting the LC9.

In this case, ACTION Statement "b" or "c" will er.sure the valves perform their post-containment isolation function. Therefore, the entry into other OPERATIONAL MODES should not be prohibited because the valves will be performing their isolation function and would not contribute to an accident if containment isolation was required.