Letter Sequence Other |
|---|
|
|
MONTHYEARML19257B1301980-01-11011 January 1980 Forwards Tech Spec Change Request 57 to Amend App a to License DPR-72.Change Involves Intermittent Operation of Containment Isolation Valves for Sampling & Testing. Affidavit,Certificate of Svc & Class III Fee Encl Project stage: Other ML19257B1411980-01-11011 January 1980 Tech Spec Change Request 57 to Amend App a to License DPR-72 for Intermittent Operation of Containment Isolation Valves for Sampling or Surveillance Testing Purposes.Replacement Tech Spec Pages 3/4 6-15,17,18,19,20 & 21 Encl Project stage: Other ML19296B0381980-02-15015 February 1980 Tech Spec Change Request 58.Moves Surveillance Requirement for Testing of High Radiation Initiation of Control Room Emergency Vent Sys from Spec 3/4.7.7.1 to Spec 3/4.3.3.1. Tech Spec Pages Encl Project stage: Other ML19296B0341980-02-15015 February 1980 Forwards Tech Spec Change Request 58 for Amend to App a of Ol.Amend Places Testing of Radiation Monitor RM-A5 in Radiation Process Monitoring Spec.Class III Amend Fee, Proposed Replacement Pages & Certificate of Svc Encl Project stage: Other ML20032C2331981-10-30030 October 1981 Tech Spec Change Request 5.7,Revision 1,to Amend License DPR-72 Requesting Relief from Provisions of Tech Spec 3.0.4 Under Certain Specified Conditions Project stage: Other ML20032C2301981-11-0202 November 1981 Forwards Tech Spec Change Request 57,Revision 1 Requesting Relief from Provisions of Tech Spec 3.0.4 Under Certain Specified Conditions.Certificate of Svc Encl Project stage: Other ML20032C2371981-11-0202 November 1981 Proposed Tech Specs Requesting Relief from Provisions of Tech Specs 3.0.4 Under Certain Specified Conditions Project stage: Other ML20038C4331981-11-24024 November 1981 Amend 44 to License DPR-72,revising Tech Specs Requirements for Testing of Radiation Monitor Project stage: Other ML20038C4371981-11-24024 November 1981 Safety Evaluation Supporting Amend 44 to License DPR-72 Project stage: Approval ML20038C4401981-11-24024 November 1981 Notice of Issuance & Availability of Amend 44 to License DPR-72 Project stage: Other ML20072F2211983-03-10010 March 1983 Notice of Issuance & Availability of Amend 63 to License DPR-72 Project stage: Other ML20072F2091983-03-10010 March 1983 Safety Evaluation Supporting Amend 63 to License DPR-72 Project stage: Approval ML20072F1931983-03-10010 March 1983 Amend 63 to License DPR-72,exempting Certain Containment Isolation Valves,After Valves Placed in Containment Isolation Position,From Provisions of Tech Spec 3.0.4 Project stage: Other 1981-10-30
[Table View] |
Text
._
I Revision 1 10/30/81 r
TECHNICAL SPECIFICATION CHANGE REQUEST N0. 57 (APPENDIX A)
Replace pages 3/4 6-15, 3/4 6-17, 3/4 6-18, 3/4 6-19, 3/4 6-20, 3/4 6-21, and 3/4 6-21a with the attached revised pages 3/4 6-15, 3/4 6-17, 3/4 6-18, 3/4 6-19, 3/4 6-20, 3/4 6-21, and 3/4 6-21a.
Proposed Change Add ACTION Statement "e" to read: "The provisions of Specification 3.0.4 are not applicable to those valves in Table 3.6-1 annotated by asterisks."
Asterisks have been added to appropriate valves in Table 3.6-1.
Reason for Proposed Change ACTION "e" has been proposed for Specification 3.6.3.1 for valves that are performing their post-containment isolation function, but are inoperable and ACTION Statement "b" or "c" is in effect.
Since these valves are already in their post-containment isolation configuration, they neither perform an emergency core cooling function, nor offer any hindrance to normal plant operations while shut or isolated. There is no reason to restrain the entry into other OPERATIONAL MODES.
Therefore, the exception to the provisions of Specification 3.0.4 is proposed.
Safety Analysis of the Proposed Action Entry into an OPERATIONAL MODE is restricted in that the conditions of the Limiting Conditions for Operation (LCO) must be met without reliance on ACTION statements unless specifically excepted.
Specific exceptions can be granted when the ACTION statement places the unit in a condition which is equivalent to meeting the LC9.
In this case, ACTION Statement "b" or "c" will er.sure the valves perform their post-containment isolation function. Therefore, the entry into other OPERATIONAL MODES should not be prohibited because the valves will be performing their isolation function and would not contribute to an accident if containment isolation was required.
8111090532 011102 PDR ADOCK 05000302 P
PDR
-