l

\\

t 1) s

/

Westinghouse Entr': D oration laduitry & Defense c=xcesameans Dc::rtn: Tee C.cs.:n Bar234 8

I' draWAYCrt14302 (607)733 7351

~

March 1, 1974

\\

Addendum to Accident Environment Test for Class A,B,C,D,E & F penetrations - applicabic to all Brunswick types UEtt spec.

9527-01-ll8-1-CP141 comment on lack of humidity test.

The specification requires a temnerature of (1) 340 F at 56 PSIC, (2) 250 F at 25 PSIG and (3,) 200 F at 20 PSIG all at a concurrent 100% humidity.

The first condition is a superheated steam condition.

The second two are at pressures and temperatures that result in wet stca, conditions since the temperature, are t o ;cr thcn tha saturated teraperatures required by Lt.: prcosurcs.

Hence with the exception of the first six hours the prototypes were expos'ed fer at least 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> to wet steam with a humidity of 100%.

The intent of the specificaticn therefore has been met to the extent of physica*- possibility.

/ /*

lm_,.*','. 6u :

R. L. Korner Project Engineer Penetrations Dept.

/m 1