%Y
- FORM 21 CD&L P
oM Caro'ita Power & Ught Company Raleigh, N. C. 27602 October 26, 1981 Mr. Cyril Crane jM y Franklin Research Center Parkway at Twentieth s.V Philadelphia, PA 19103
((
[
BRUNSWICK STEAM ELECTRIC PLANI, UNIT NOS. 1 AND 2 b OCTO I
I 1 42. ton,j@O8/A j DOCKET NOS. 50-325 AND 50-324 LICENSE NOS. DPR-71 AND DPR-62
{
ren Q ENVIRONMENTAL QUALIFICATION p
Dear Mr. Crane:
As requested in a telephone ct'nversation sith you c; July 31, 1981, Carolina Power & Light Company f /6L) hereby supplies additional information concerning the Brunsvipk Steam Electric Plant's response to Supplement 3 of IE Bulletin 79-015 dated January 30, 1981. Attached, as requested, please find the following test reports:
1.
Ace'. dent Environment Test Report westinghouse Pen-RLK-5-24-73 2.
Materials Analysis for Westinghouse Penetrations H-338-3 3.
BIW General Data Sheet - Test Under LOCA Conditions
- 8174 (1-14-72) 4.
BIW Materials Analysis Report H-338-1 Additionally, as requested, the following informatiou is provided:
i 1.
The January 30, 1981 submittal describes the qualification of i
Acoustic Monitors for the Safety Relief Valves which correlates I
to IUREG-0737 Item II.D.3, " Direct Indication of Relief and Safety Valva Position".
2.
The normal environment inside the Brunswick containment as described in the FSAR is:
l a.
Average Drywell Temperature is 135*F b.
Maximm Drywell Temperature is 150*F (during normal operation) c.
During power operation, the containment has a positive presrure between 0.15 and 1.25 psig at 105'F d.
Content of the atmosphere is nitrogen with less then 4% oxygen 11020L]p 81 I
ssi 1
Mr. Crane We trust this information satisfies your concerns and is suitable for your use.
If you have further questions on this subject, please contact our staff.
Yours very truly, Original Signed By E. E. UTLEY E. E. Utley Executive Vice President Power Supply and Engineering & Construction JHE/1r (8426)
/
cc: Mr. J. Van Vliot (NRC)&
Mr. T. A. Ippolito (NRC)