e May 11, 1994 Docket No. S0-219 Mr. John J. Barton Vice President and Director GPU Nuclear forporation Oyster Creek Nuclear Generating Station i
Post Office Box 388 Forked River, New Jersey 08731
Dear Mr. Barton:
SUBJECT:
OYSTER CREEK NUCLEAR GENERATING STATION - EVALUATION OF EFFECTS OF HIGH TEMPERATURE ON DRYWELL SHIELD WALL AND BIOLOGICAL SHIELD WALL, SEP TOPIC Ill-7.B " DESIGN CODES, DESIGN CRITERIA, LOAD COMBINATIONS, AND REACTOR CAVITY CRITERIA" (TAC NO. M76879)
The NRC staff has completed the review of the subject SEP Topic.
Based on the review of the information submitted in various submittals by GPU Nuclear Corporation the staff concludes that the Drywell Shield Wall (DSW) and the Biological Shield Wall (BSW) at the Oyster Creek Nuclear Generating Station are capable of performing their intended functions.
The staff, however, recommends that GPU Nuclear Corporation monitor the conditions of the DSW and the BSW at periodic intervals to ensure their continued functions.
Based on the completion of this effort we consider SEP Topic III.7-B" Design Codes, Design Criteria, Load Combinations, and Reactor Cavity Criteria" resolved.
We consider our effort on the subject TAC No. M76879 to be complete.
Sincerely, Original signed by:
Alexander W. Dromerick, Sr. Project Manager Project Directorate 1-4 9405190152 940511 Division of Reactor Projects - I/II j
DR ADOCK 05000219 Office of Nuclear Reactor Regulation PDR
Enclosure:
Safety Evaluation cc w/ enclosure:
see next page DLSlRIBUTION:
[', W ',i Docket File SNorris JRogge, RGI y j,'~
i 4
NRC & Local PDRs ADromerick PDI-4 Plant ilAshar SVarga OGC JCalvo ACRS (10) 0FFICE LA: PDI-4 PM: PD1 s4 D:PDI-4, S}drfis rNick:bf JStolz hr7dpS
~
- E N
G /H /94 r /g /94 ti/J)/94 b
/
/94
/
/
OFrirlAL RECORD COPY g),
1)ocument Jiame:
G:\\DROMERIC\\M76879.SE g4 ]i _
a uoun
m A
May 11, 1994 4-Docket No. 50-219 Mr. John J. Barton Vice President and Director GPU Nuclear Corporation Oyster Creek Nuclear Generating Station Post Office Box 388 Forked River, New Jersey 08731
Dear Mr. Barton:
SUBJECT:
OYSTER CREEK NUCLEAR GENERATING STATION - EVALUATION OF EFFECTS OF HIGH TEMPERATURE ON DRYWELL SHIELD WALL AND BIOLOGICAL SHIELD WALL, SEP TOPIC III-7.B " DESIGN CODES, DESIGN CRITERIA, LOAD COMBINATIONS, AND REACTOR CAVITY CRITERIA" (TAC NO. M76879)
The !RC staff has completed the review of the subject SEP Topic.
Based on the review of the information submitted in various submittals by GPU Nuclear Corporation the staff concludes that the Drywell Shield Wall (DSW) and the Biological Shield Wall (BSW) at the Oyster Creek Nuclear Generating Station are capable of performing their intended functions.
The staff, however, recommends that GPH Nuclear Corporation monitor the conditions of the DSW and the BSW at periodic intervals to ensure their continued functions.
Based on the completion of this effort we cont.ider SEP Topic III.7-B" Design Codes, Design Criteria, Load Combinations, and Reactor Cavity Criteria" resolved.
We consider our effort on the subject TAC No, M76879 to be complete.
Sincerely, Original signed by:
Alexander W. Dromerick, Sr. Project Manager Project Directorate I-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/ enclosure:
see next page QISTRIBUTION:
Docket File SNorris JRogge, RGI NRC & Local PDRs ADromerick PDI-4 Plant HAshar SVarga 0GC JCalvo ACRS (10) 0FFICE LA:PDI-4 PM: PDI.,4 D:PDI-4n NAME sr r
ick:bf JStolz kth6 DME C /d /g4
/jj /g4
/(/))/94
/ /94
/
/
OFFICIAL RECORD COPY Document Name:
G:\\DROMERIC\\M76879.SE
q>R REG g
?
1 Qg,,, / [ g
- z 9
UNITED STATES f
j!
NUCLEAR REGULATORY COMMISSION g yf e
WASHINGTON, D C. 20555-0001 May 11, 1994 Docket No. 50-219 Mr. John J. Barton Vice President and Director GPU Nuclear Corporation Oyster Creek Nuclear Generating Station Post Office Box 388 Forked River, New Jersey 08731
Dear Mr. Barton:
SUBJECT:
0YSTER CREEX NUCLEAR GENERATING STATION - EVALUATION OF EFFECTS OF HIGH TEMPERATURE ON DRYWELL SHIELD WALL AND BIOLOGICAL SHIELD WALL, SEP TOPIC III-7.8 " DESIGN CODES, DESIGN CRITERIA, LOAD COMBINATIONS, AND REACTOR CAVITY CRITERIA" (TAC N0. M76879)
The NRC staff has completed the review of the subject SEP Topic.
Based on the review of the information submitted in various submit,tals by GPU Nuclear Corporation the staff concludes that the Drywell Shield Wall (DSW) and the Biological Shield Wall (BSW) at the Oyster Creek Nuclear Generating Station are capable of performing their intended functions.
The staff, however, recommends that GPU Nuclear Corporation monitor the conditions of the DSW and the BSW at periodic intervals to ensure their continued functions.
Based on the completion of this effort we consider SEP Topic III.7-B" Design Codes, Design Criteria, Load Combinations, and Reactor Cavity Criteria" resolved.
We consider our effort on the subject TAC No. M76879 to be complete.
Sincerely, YY A
Alexander W. Dromerick, Sr. Project Manager Project Directorate I-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/ enclosure:
see next page
,n.
l I..
Mr. John J. Barton Oyster Creek Nuclear Vice President and Director Generating Station cc:
Ernest L. Blake. Jr., Esquire Resident Inspector Shaw, Pittman, Potts & Trowbridge c/o U.S. Nuclear Regulatory Commission 2300 N Street, NW.
Post Office Box 445 Washington, DC 20037 Forked River, New Jersey 08731 Regional Administrator, Region I Kent Tosch, Chief U.S. Nuclear Regulatory Commission New Jersey Department of 475 Allendale Road Environmental Protection King of Prussia, Pennsylvania 19406 Bureau of Nuclear Engineering CN 415 BWR Licensing Manager Trenton, New Jersey 08625 GPU Nuclear Corporation 1 Upper Pond Road Parsippany, New Jersey 07054 Mayor Lacey Township 818 West Lacey Road Forked River, New Jersey 08731 Licensing Manager Oyster Creek Nuclear Generating Station Mail Stop:
Site Emergency Bldg.
Post Office Box 388 Forked River, New Jersey 08731 I
l l
l I
_ _ _ _ _ _ _ _ _ _ _. _ _