ML20029A696

From kanterella
Jump to navigation Jump to search
Effluent & Waste Disposal Semiannual Rept Jul-Dec 1990
ML20029A696
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 12/31/1990
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20029A695 List:
References
NUDOCS 9103040047
Download: ML20029A696 (45)


Text

--.

DRESDEN NUCLEAR POWER STATION l

UNITS 1,2, AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

_ _.. July _ Through December _. 1990 GASEOUS EFFLUENTS Docket Numberst 50-10 50-237 SUMMATION OF ALL RELEASES 50-249 EST. TOTAL TYPE JF RELEASE UNITS 3rd QUARTER M b QUARTEP ERR 011,%

_EISS10fLANILACTIVAT10lLOASES 1.

Total Release Cl 6. 7 u..

1.17E+00 7.31 2.

Av[rageReleaseRateforPeriod uCi/sec R.44E-01 1.47E-01 3.

Percent of Technical Specification Limit A

A Ih._.10 DIN ES _

l.

Total lodine-131 Ci 1.04E-03 5.41E-04 9.51 2.

Average Release Rate of I-131 for Period uCi/sec 1.31E-04 6.81E-05 3.

Percent of Technical Specification Limit A

A I

4.

Total Iodine-131, Iodine-133,and lodine-135 C1 1.35E-02 1.13E O2 Cm.PARTICUMTES 1.

Particulates with half-lives > 8 days C1 3.19E-02 5.09E-02 8.09 2.

Average Release Rate for Period uCi/sec 4.01E-03 6.40E-03 3.

Percent of Technical Specification Limit A

A 4

Gross Alpha Radioactivity C1 1.01E-05 LLD lb _TRITIU?1 1.

Total Release Ci 4.86E+00 1.03E+00 7.89 2.

Average Release Rate for Period uCi/sec 6.11E-01 1.30E-01 3.

Percent of Techni, cal Specification Limit A

A A The information is contasaad in the Radiological Impact on Man section of the report. Total airborne release data is provided which includes fission and

-activation gases, lodines, particulates, and tritium.

ZEDE91/48-9103040047 910228 DR ADOCK 0500001o PDR

~. - -

= -_

DRESDEN NUCLEAR POWER STATION UNITS 1,2, AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Julv Through _Datembar_ 1993 GASEOUS EFFLUENTS Docket Numbers: 50-10 50-237 SUMMATION OF ALL RELEASES 50-249 LLD (uC1/cc) 1.

FISSION GASES Ke-133 1.47E-07 Ke~135m 6.35E-08 Kr-8_7 3 61E-08 KE-S8

_5 8.QE_Q8 2

Kr-83m 1.B.QE-08 Kr-85 4.31E-06 Xc-131 1 13E-08 Ke-133 4.08E-08 Ar-41 2.29E-08 2.

10 DINES 1-131 8.0EE-13 1-133 5 19E-12 1-L31_

9.32E-10 3.

PARTICULATES Sr-89 LO0E-15 Sr-90 1 10E-15 Cr-51 6.23E-13 Mn 7.77E-14 Co-18 6.37E-14 fe-55

1. LQE-13 fe-59 1.38E-13 Co-60 1.9hE-13 Zr.-95 1.3ZE-l3
Nb-95 7.65E-14 Mp-99 1 02E-12 Ru-lD3-7.71E-14

.Ar-110m 7.06E-14 Sb-114 7.70E-14 1-131 9.38E-14 Ca-l34 7 (21E.lf.

Ca-136 L6 7E-: 't.._.

Og-137

_JJ2E-14 Ha-140 3.11E-13 La-140 1.17E-13 Cn-l!11._

1.13E-13 C.e-ll 4 4.47E-13 L

Zn-61 1 d3I-13 Da-131

__9.51E-14 Sb-125 1.93E-13 Others:

Gross Alpha 3.00E-15' L

2EDE91/48 l

13 of 34 i

~

t

DRESDEN NUCLEAR POWER STATION UNIT 1 EFFLUE.,f AND WASTE DISPOSAL SEM1 ANNUAL REPORT July Through _ December _ 1999 DLChimacy_ GASEOUS EFFLUENTS GROUND LEVEL RELEASES Docket Number:

50-10 SEMI-ELEVATED RELEASES XX ELEVATED RELEASES CONIlNV0VS._110DE BAICRJ0DE. _

tth QUARTER 3rfl QUARTER l

hth QUARTER HUCL1 DES RELEASED UNIT 3rd QUARTER i

__.._11S S10R_ GAS ES_

.__._ Xe:13 8

_CL Xe-13hm

_Ci Kr:81

_CL Er-BB JL

_Krr85m

_C L

___Er-85

._C L

__...Ke-135_ _

_.01 _

Xe-113

._C L

70IA1,

_CL NONE NONE

___10 DINES I-131 Ci

_ __1-13.1

,CL I-135 Ci TOTAL CL

.MONE RONE ZARTICULAIES__.

_.__firr8 9 Ci S.14E-06 Iv81E-05 t

Sr:20

_Ci_.

8.6DE:QB 7J 2E-07 Cr-51

._C1_

Mn 54

._Ci_

5.2tE-DZ.

1 00-58 01 f.e-51

_CL 00-60 JL LDIE106 1 82E-05

__._Zr-25 Ci Nb-95 C1.

Ru:103 Ci

.Ag-110m

_CL

___ Sb Lal

_CL

__1-13 L

._C L

_ _ Ca-134

_C L Cn.116

-.C L

_.._Cm:137

_C1_

hi2ZE- 06

_ _ 3.dQE-Q6

. _ __J a-lh.0.

Ci Ia-lho

_CL CcelA1

_Ci Cerih4 C.L

,.-.1n-h5 31_.

.._ la-123 JL

__.Jih_125 JL A

Ee-55

_Ci_

2 dlE-QL___.

_ BJ1' -05 i

___.ZOTAL

_Ci_.

A sh2E:D5_

1.61E-04 NONE RONE

  • The activity of t.his nuclide in less than the LLD listed on the appropriate table.

ZEDE91/48 j

14 of 34 l

~... -.

~-... -. -

'~

DRESDEN NUULEAR: POWER STATION UNIT 1 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT July Through _.Sepirmhnt 199.0 DLChimacy__. GASEOUS EFFLUENTS GROUND LEVEL RELEASES Docket Number:

50-10.

SEMI-ELEVATED RELEASES XX ELEVATED RELEASES CONIIN110VSJ0DE_

NUcLIDES RELEASED UNIT JULY AUGUST SEPTEMbt,R 3rsi QUARTER TOTAL

..ElSSlotLGbSES_.

Xer.1R

- Ci Xc-115m

_.CL

..___Jr:BZ

_CL

,It-68_

CL

__Kr-83m ci

._ lr E5 __.

JL Ac:L35

_c1 w

. _Xc:131

._CL 101AL

_ci_

-_ JDDlNES

- _.2.13L:

JL I:113

_CL

_ I-135 3 1._

TRIAL

_CL PARH QU1AIES _

Br-89_

ci

.b.2hl-0L_

5._2hE-06

_ _..Br:9.0 _

. JL

_ _8.. fide-08 _

,_8h0E:0B_ _

cr:51 JL 11a:16

CL

__00:58 ci.

- _ __ft:59 _

_ _ ci _

.._Co 6h

.CL 5 !t6E-06 L.15E-Qh _

I.01E-01 i

_.._Zr:25 01-Nh:25 JL Ru-103 -

ci

..__ As-L10m.

JL

_ Jh:1Mt 31,

._1:131 01

_.CE-116 ei

._ Ja:136

_CL Ca-131 JL 3.62E-06 2.0.21.-0.6 6.31E-07 6 _2ZE-06 Jn-1!t0 CL La=LbD CL ce:L41

_i CL s

_Cn:1M

L

-2nzhi AL

_had33,._

_.CL

._, Jib.2125_

ci

.,_..Ee 55

-c1 -

.A 10E.06 4 m32E-0.6

1. 70E-OL_

_2 61E-05 1

_10IAL._,

_CL 8.32E-06 1.12E:05_

2.45E-05 4.47E _

  • The activity of this nuclide is less than the LLD listed on the l

l appropriate table.

i l

)

ZEDE91/4C 15 of 34 t

L,,a

_.. -. _ - - -. _ ~. _...

_ _ _. - -. _ -. ~ _. _

'~

DRESDEN NUCLEAR POWER STATION.

UNIT 1

+

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT QAtub.cI__ Through._Denemb1r_ 1910 D1_ Chimney __ GASEOUS EFFLUENTS GROUND LEVEL RELEASES-Docket Number:

50-10 SEMI-ELEVATED llELEASES u-XX ELEVATED RELEAS?,S CONIlllQQUS. M0')E iNUCLIDES RELEASED UNIT OCTOBER NOVEMBER Dt:0"SES ith QUARTER TOTAL D-FISS101LGASES-4 Ke-118

_Ci_

LXe-135m 01 n

Kr-.31

_.CL 4

^Kr-88

_CL F,r-85m -

_Cl Kr-85

_CL

.Xe-135

_Ci_

}

]Le-133

_C1__

TOTAL C1 30 DINES ~-

I-131-

._C i_.

.1-133-J1_

1-135

_C1 iTOTAL Ci PARTICUIATES__.

I

._ _Er-89 01<

-1.62E-05 1,57E-05 1.62E-05 4.81E-05 Sr-90 C1-2.67E-07 2.58E-07 2.67E-07 7.92E-07 Cr-51' 0L Mr.-54

. Ci

'5.94E-07 5.94E-07

__30-58

._Ci-Fe-59

,_Qi Co-60

__ _CL 4.99E-06 5.2kE-06 8.66E-06

1. 8 9 EJ -Zr-95

_Qi_

Nb-95

_C1

-Ru-103 iC1 Ag-110ml 01

'Sh-124 01 I-131

_QL

.___ CA-134

_Ci_

  • =

s ___ Carl 3.6 Cil

Os_i37

-01 8.27E-07 1.14E-06 1.63E-06' 3.60E-06

- BA-140f JL La-140-

- _C1_

- Cg-ll L Ji_

t

-Ce-144'

01
  • ~

g i &rL-fi5

_C1 2._.Lha-13.3 <

_Ci'

  • ?

Shri25

_C i_.

~*

9.g.e-$5 C1-3 QDE-Qji_

2 & E-05

'3 &QE-05 8.91E-QS.__ _

TOIAL

_Ci Si13E-05 5.14E-05 5.74E-05 1.61E-04'

  • The activity of this nuclide-is less than the LLD listed on the=

appropriate.- tabl e.

w

.ZEDE91/48-16 of 34' l

.jgl,,

yl E

...-G

+-:.-,,,..

DRESDEN NUCLEAR POWER STATION UNITS 2 AND 3 EFFLUENT - AND WASTE DISPOSAL SEMIANNUAL REPORT

_ duly Through _.Denemiter._1990 D2/3._ Chimney CASE 00S EFFLUENTS GROUND LEVEL RELEASES Docket Numbers:

50-237 SEMI-ELEVATED RELEASES 50-249 XX ELEVATED RELEASES cORIJEHQRS. MODE BATCit tiODE

'NUCLIDES RELEASED UNIT 3_rd QUARTER

!tth QUARTER l

3rd QUARTER hih QUARTER FISSIDE_DASES_

__Xc 138 JL Km:135m

_CL

___Kr:82

.._CL Kr-8.8

_CL Kr:B5m

_CL Kr-B5

._CL 21fiBE-03 122BE-03 Xc-135

__ _Ci_

6,71E+00 5 dQE-Q1 Xe:133 JL

_Ar-41 Ci TOTAL JL 6_.1.1Ei.00 5 dlE-0_1 MONE MONE IQQINES I-L31

._C L 8 12E-Oh 5.21E10h_

I-113 li -

4.31E 03

_ _3102E-03 1-135 C1 3 25E-03 6.75E-03 10TAL JL B.d3I-03 la3I-01 NONE NONE

_ _.IARILCUIATES_

Sr-89

._Ci_

2.70E-04 St-9.0 JL 1.04E-06 Cr-51 JL

. Mn-l.4

_CL 3.251.05 6 22E-06 1

co:5B

_C1_

En:59

_Ci_

.00-6.0 '

C1 1.55E-04 1.98E-04 Zr-95

._CL Nh._95

._CL Ru-10]

JL Ag 110m

_Ci_

4 42E-05 Sb-124 01

___1:131

._C L 1 22E-04 1.39E-04

._ Ca-13!t c1 cs-L3fi

. _CL Ca:137 C1 1.39E-04 2 51E:Q5 Ba-140 01 9.73E-04

.fL,35 E-04 La-1A0

_ C1_.

1.10E-03

9. 65E_Ql.L c :141 ci e

._._Cn.144

__C L

.Zu:65

.Cl

'.-_ _Det_133

._C L

_...Jih-125 JL.

__h 5.3 fl.

5.47E-04 1,.483:Q3 TOTAL

_C1 l 3.1BE-03 3.1h1E:Q3 NONE NONE

  • The activity of this nuclide is less than the LLD listed on the appropriate table.

ZEDE91/48 17 of 34

DRESDEN NUCLEAR POWER STAT!ON UN!*S 2 AND 3 EFFLUENT AMD WAS'15 DISPOSAL SEMIANNUAL REPORT

__ _ July Through Sepicmhar 199_Q nal3_. Chimney GASEOUS EFFLUENTS GROUND LEVEL RELEASES Docket Nur..bers: 50-237 SEMI-ELEVATED RELEASES 50-249 XX ELEVATED RELEASES CONIINUOVE MODE NUCLIDES RELEASED UNIT JULY AUGUST SEPTEMBER 3rd QUARTER TOTAL

_ _EIHSION_ GASES _

Xe 138 C1 Ke:135m JL

_ _Kr:B.L

_CL

_._Kr-88

_C1.

Kr:85m

_Ci_

.Krza5_

aL

___2.iO5I-Q4 7 BlE20.4

_._.1 d9.E-03 _

2dBE-03 i

xe:135

._Ci_

4.42E+00

_2.29E+00 611EiD0 3

__Xe:131 C1 -

Ar:A1

_.C L TOI6L CL 4.4ZE+00_

7 B]I _0ft_, _

2J92100___

6. 7.1 E+00

_ _10HINES

_ _I-13L 31_

2. HE:0A J.10E-04

___L33 E-04

_St.12E-04

__I:133

.,fL i d BE_03 L12E-Q3 1 h7E-03_

b52E:03

_1-135

._CL 5.56E-04 L.Zh E-03 9. 3 3E-.0h__.

3 25E-03

_ _IOTAL

_CL 2.t30E-03 3.70E-0.3 2 6AE-03 BJ 31-Q3 IARTICUIATES _

._ _Br:89

.CL 9 J7E:05._._

1,.05E.-04 7 <1AE-05__. _ 2..ZDE:0A__ __

._.Sr-3.0

_C1_.

2.39E-07 4 4hE-07 3.511-07 la0hE 06 Cr-51 Ci

_MR-5A C1 1,.SSE-05 7,.33E-Q6.

3.23E-06 31252-05

-Co-SS

._qi Ee:59

._C L Cn.f.0 0L 1.12E-04 L.90E-05 2.44E-05 1.55E-04 Jr-95

_CL Nb-95

_Ci_

Rn-103

.31

_._Ag:110m

_CL 4.01E-Q5 4.07E-06 4.42E-03 Sh:12!L C1 t-121

. 31_

6.1hE-05 l d2E-05 l'. 4 3 E-05 __

1 12E-DA t

__ _Ca:124

_01_

_.._C62136

_CL

_.__ Car) D_

CL 1.15E-04 2,38E-05 L39E-04 J an:!io 01_

4 52E-04 3.20E-04 2.01E-04

9. 7_3E-04

.La:1 W CL 4.d6E-04 3 d2E-04 2.61E-04 1.10E-03 Ce.nlltL

._ _CL Cc 1hb_

_CL

.-. l R-65' Ci

__Ba 13 L_

_ __C1

_ Sh-125 ci Ee-53

_ _CL LA9E-04 1.58E104 2.40E-0A 5A2E-0lt

_ IQTAL-

_fl._

i dZE-03 1109I-03

__BJ2E-04 3.33E-03

  • The activity of this nuclide is less than the LLD listed on the appropriate table.

ZEDE91/48 18 of 34 w.

DRESDEN NUCLEAR POWCR STATION UNITS 2 AND 3 EFFLUENT AND WASTE DISPOSAL SEMIAh'NUAL REPORT

._Qntcher_ Through.Denemher_ 1920 D2/33 himney GASEOUS EFFLUENTS

_ GROUND LEVEL RELEASES Docket Numberst 50-237 SEMI-ELEVATED RELEASES 50-249

)QL_ _ ELEVATED RELEASES C.0NTINUQUS_.110DE NUCLIDES RELEASED UNIT OCTOBER NOVEMBER DECEMBER Alh QUARTER TOTAL

_.EISSION_ GASES _

___Xe-138 JL Ker135m

_ SL Kr-87

._01._

__ _Kr:BB

._C L

._ l t-85nt 3L Y,r:81_

Q1 6.11E-04 4 dQE-Q4 2.45E-04 ld BE-Q3

-xe-133 ci 2.49E-01 3,11E-01 5J QE-01 Xe_133 31 Ar:41 JL

_ _IDIAL.

_CL L5DE-QL.,_ _

3 11E-01 2.ASE-04 5.61E-01 IDDINES I-131 C1

..... 2. BJ E-04 1229E-04 1.05E-04 5,_21E-04

.___.I:13 3

_.0L 1 12E.-03 ZJ0EQ4 6 &QE-04 3.02EQ3 1-135

_CL L52kO3 5<ZbE-04

__._ L 61E-03 6,15 kD3 XOTAL

_.01 4.53E-03 1.41E-03 4.36E-03 1.03E-02 PABIIQUZAIES

_ _St-89

_01_

Sr-3.0

._CL CI-51 JL

.tht-5A

_Ci_

6 22E-06 6.22E-06 t

co-38 Ci Je:19

_CL Co-60 91_

7.57E-Q5

._..1.92E05 1J3E-04 I S8E-A J

t lt:21_

_Ci_

~*

Nb-95

_Q1_

- _ Ru.-103 JL As.110m

_CL Sb 12A li 1:131

_C1_

8,11E 3 3.21E-05 2 5.4E-05 1.29E-04 6

Cs-13A si Ca=L36

..CL-ca-13L

_qL 8 JhE-Q6 1.71E-05 2 31EQ5

.Ila-140

_Ci_ _

3.15E-04 IJ1E-04 1.33E-04 6A 15:0A

____Ea-Js0 CJ 4.04E-04 3.40E-04 2.21E-04 2 65E-04 Cc-Lhl

_C L

_. _CerL44 -

_.0 L

. _.ln 45

_CL

-,__Ba-133 JL

+

_.._Sb-125

_D1_

_A.,l BE.Q3 5.11E-04 4.60E_Q4 5d2E-04

. !_JL Ee:55 t

Ci_

1.32E03 1 44 EQ3 1A2E-03 3,A&E-Q3

_IOTAL

  • The activity of this nuclide is less than the LLD listed on the appropriate table.

ZEDE91/48 19 of 34'

~

DRESDEN NUCLEAR POWER STATION UNITS 2 AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT luly. _ Throut,h _.DcAcmhcr_1920 D2L3_Reactotluilding_Eeat GASEOUS EF5'1UENTS GROUND ^~JEL RELEASES Docket Numbers:

50-237 XX SEMI-3LEVATED RELEASES 50-249 ELF',ATED RELEASES CONTINHOMS_.t10DE BATCil RQDE NUCLIDES RELEASED UNIT 3rd QUARTER hth QUARTER 3rd QUARTER 4th QUARTER ELSE1QH ClLSE L le-138 3L

- Xc-1352n CL

-_It-aZ.

._CL Kr-BE Ci Kt-B5m

_ 01_

- _1t-B.5 1L

___ le:135 CL 6A8 E-01.___

Ke-133.

._C L TOTAL

_Ci

_b.08E-01 NONE fiQUE

.-.__ IODINES-

.J-131 A

LJ1E-04

_ L.93E-05 I-l3.3 CL LIBE 03 L 30E-03__

X.135

_C1 2.dlE-03

_ _R.10E.QA.

_._ IQIAL, C1 i.42E=03 9.60E Q.4

.1[0NE NQEE t

' RIlC#IKc'__

Sr:8.9_ _ _

_.._CL 4.79E-Oh Sr:90c

_.CL Cr-51

_ C.i 1.09E-03 2 33E-04 Ma=5 h. _.

-.91_

Lx2 lie =Q1.

3 31FeDh 1

Cn-la Ci ItZ1E-04 6,.39E 05 fc-5L-C.L 5 21E_04 J J 2E_01.

Cu-h.0 31_

L2EE03 7 92E-04 It 93

. 0i_

Nh:25 _

Ci

.,,3u 101

_CL

__Ag1LQm 01___

7.. 30 E-05 Stt:12!t.

CL o

_ _I-13 L

._C1

_ _.L_03h05_ _

2.t12E_0.6

_._Ca:13tt

__C L

_Ca-13L Qi_

.Ca:132

_CL

l. JAI:05--.

._ h1AQ.

Ci 3.hlE-04 7 331;-06 Lu:140 01,

.3.,_I 1 E-04 7.331;-06 t

CerthL_.

...C L L

_Ce-1M

.CL

_. Zu M Q1 Li&E 4.59E-06 L

an:133 C1 i

l

. -..-.h9.L.

31.

LIEE 03 9.121E-05 Sb 125

_.0L

' _.f.e
53

__ C1

-1.53E-Q?.

b 57E-02 TQIAL._

_C1

.1 81E-Q2.-

4.73E-02 XQNE NONE

  • The activity of this nuclide is less thc.n the LLD listed on the appropriate table.

i L

.ZEDE91/48 L

. 20 of 34 l.

1*

i

DRESDEN NUCLEAR POWER STATION.

UNIT 2-AND.3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT July __ Through September _. 1920 22/3 Reactor Building Vent GASEOUS EFFLUENTS-GROUND LEVEL RELEASES Docket Numbers:

50-237 XX SEMI-ELEVATED RELEASES 50-249 ELEVATED RELEASES C0f{IIN3QUS MODE -

INUCLIDES RELEASED UNIT JULY AUGUST SEPTEMBER 3r.d QUARTER TOTAL FISS10N_ GASES _

Xe-118

_ Di_.

Xe-135m CL Kr 87 C1 Kr-6&

AL

-,r-85m C1 7

._ 3r285

_Ci_

__Xel25 01 Xe:133

_.01_

TDIAL_

Ci 1DDlN.ES 1-131

_Q1 3.92E_Q5 8.80E -1.DA E04 2dlE-04 I-133

-01 1 38E-04-'

8.77E-04 7.66E-04 1.78E-03

'Isl35

_Qi 1.79E-03 1.02E-03 2.%E-03 TD.IAL ^

C1 1.77E-04

~2.76E-03

1. 8 9 E-0.3_._.

4.82E-03

-PARTICQLATES Sr:89_

_C1_

3.85E-06 9.43E-07

_a.79E-06

-Sr-90 Ci

- Cr-11__

_C 1._._..:. 8 11E-05 4 ~. 36E-04 5.63E-04_ _

1.02E-03

-Mn Ci __

2.40E-04 7.04E-04

-3.19E-04 ia16E-03

Co-58_

91_

3.87E-05

- 4 dlE06 3.17E-04 7.77E-04 Fe-59

_Ci 4.92EQ1,_._

3.64E I dhE-04 5. 2 7 E-04 --

'Cq-60

'Ci 5 ~.66E.04 3.34E-Q3 2.39E-Q3 6.30E-03

&r-95"

.Ji._

Nb-95

._Ci_

~_ Ru-1 Q3 -

Ji_

'Ag-llDE Ci_

4.63E-01 2.67E-05 7 3DE-05 Sb-U4.

01-s,_._I:-131

_C1=

1.05E-05 1,D5E_Q5

- cg-13L-^

-01

=*

01_

Cs-136 Cs-13 C 01

1. ell E:Qs --

_1 ale-04 4

Ha,14D 31_

_1.d2E-94 a

La-140-C1 1,97E-04

-1.44E 3.41E-04 Cc-141' C1 7

Ce-144

- 01_,.

Zn C1

'1.67E-04 9.0ZE-05

.2.58I04 --

Ba-133

C1._

No-22._,

C1 1.49E-04 1.12E 4.15E-04

'1.68E-03

!St.-lic C1 Fe-55

_.CL 1 37E-03 __

4.74E 9.72E-03

1. 5 8 E-0.2 -

t TDIALL fL 2.50E-03=.

1.d2E-02

~ 1. _43E-02 2,.85 E-0 2_ _

- _The activity of this nuclide is'less than the H.D listed on the:

~

Lappropriate= table.

-ZEDE91/48 -

21 of-34' w

+

-+

,-w-w-;c v+%,..,----v+

yw

-,-.e4' p.---

-4v.v.v a

w en

DRESDEN NUCLEAR POWER STATION UNITS 2 AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

_0 cipher _. Through _Denemher_ 199D D2/_3leaClor_lluilding,. Vent GASEOUS EFFLUENTS GROUND LEVEL RELEASES Docket Nurphers:

50-237

. __._XX SEMI-ELEVATED RFLEASES 50-249 ELEVATED RELEASES CONTINUQUS_MODL lNUCLIDES RELEASED UNIT OCTOBER NOVEMBER DECEMBER hih QUARTER TOTAL EISS10tLGASES_

xe:138 Ci Xe:133m

._CL Ir-81

_.01_

__ J,r:98 _.

_01

___.Kt-85m 31_

re-85 Ci_

__; Xe-135 C1 L12E-QL _

L16E. D.1 6,DBE-01

__.le.ll3 JL TOIAL li __

Ld2E-QL b361-01 0 08E:01_

J 0 DINES

_.ld31

_CL

_1.01E:05 61262

_3116.E-01 _

1.95E-05 1

I-ll3 ll 6103E-05 3.1914-j)]

. _ L_Q6E-0*

1 30E-04 1

1-135

_Ci_

1.,_2.8 E-0 4 6.H2E-05

_._S lDE-04

___._I0IAL li_

1 28E 7,1ZE-Q4 3.39E-01__.

916_0E:04 1

PARTICULAIES Sr-89 Ci Sr-91 _

C1_

Cr-51

_ _C i 2.94E-03

1. 05 E-04__

1.04E-04 2.3BE-04

._ __En.54 31_.

8.10E-05 1,19E-04 1.37E-04 LlZE-04 C0-58 CL Ll2E-06._._

1.73E-C5 3J9E-05 6.39E-05 fe _.Ci_

LJ2E-05 8 k2E-06 8 10E-06 3 Q2E-05 1

_Ck -30

_C1_.

1.74E-04 3103E-04 3,A9E-04 7.92E-Qh.

.___Zr:35

_CL Nh-95

_QL Ru-103 Ci

_._. Agd10m li

__.._Sb-124

___Q1 1-13 1

_gi_

_ _24 2E-Ob__

L12E-QL C1-134

_ _C 1 Ca-ll6 DL

_ __Ca-137

.fl_

6.93E_Q6_

1.05E-05 L ]4E-03 lla-1A0

=Ci 5.11f 6 81E-06 7.33E-06

- La-lhD li._

5 17E-07 6.iBIE-06 7.333-Q1.

, __.Ce 14 L '

01 Ce-144 JL Zn-61

__C1_.

4.59E-06 4.592-06

=*

_ _ha-133 Ci

_60-99

_C!_

1.06E-05 3.15E-05 5.04E-05 9.25E-05 St:125 Ci _

Fe-55

,,.Qi_

l 5hE-Q2 1.49E-02 1114E-02 4 52E-0.2 i

2

_ 10TAL Ci_

'1.57E-02 1 53E-02 1 11E-02 4.73E-02 2

  • The activity of-this nuclide is less than the LLD listed on the appropriate table.

ZEDE91/48 22 of 34

DRESDEN NUCLEAR POWER STATION UNITS 1, 2, AND 3 EFFLULNT AND WASTE DISPOSAL SEMIANNUAL REPORT

__Julv Through _Decemher 1920 LIQUID EFFLUENTS SU91ATION OF ALL RELEASES Docket Numbers:

50-10 50-237 50-249 EST. TOTAL UNIT Ig1 QUARTER 2nd QUARTER ERROR,%

A.._ Fl S S 10N _ ANTLACT LVAT.10N._ I'RQDU.CTE Ci 2.%E-01

1. 88 E-M 5.58 tio 1:

tritium, gaces, alpha)

2. Average Diluted Conc. During Period uCi/mL 4.13E-09 3.03E-08
3. Percent of Applicable Limit A

A L_ TRIIlW1

1. Total Releana C1 4.86E+00 6.75E+00 7.75 2, Average Diluted Conc. During Period uCi/mL 6.81E-08 1.096-06 i
3. Percent of Applicable Limit A

A G.._.DISSQLVED AND_.ENIPAINED_GASIS

1. Total Release C1 2.43E-05 3.97E-05 5.58
2. Average Diluted Conc. During Period uC1/raL 3.40E-13 6.39E-12

~

-3. Percent of Applicable Limit A

t Dd40SE ALEllo._lMR10ACTIVIIY 1,96E-06 15.1

{

1. Total' Release:

Ci 1.64E-06 5. VOLUME- 0F WASTE RELEASED (prior to diltition)

Liters 9.31E+06 1.09"+07-5.00 F.

VOLUMEOFDILUTIONWI.TERUSEDDUhINGPERIOD liters 7.14E+10 6.20E+09 5.00 A The information 'in contained 'in the Radiologi.:al Impact on Man section

~

iof.this. report.

Total-liquid release data is provided which includes fission and activation products, tritium., and dissolved and entrained gases.

L 1

l l

ZEDE91/48 23 of 34

DRESDEN NUCLEAR POWER STATION UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL SEMIMINVAL REPORT luly Through _Dnember_ 1910 TABLE OF LOWER LIMITS OF DETECTABILITY Docket Numberst 50-10 FOR LIQUID EFFLUENTS 50-237 50-249 NUCL1DE LLD (uC1/mL)

Sr-19 LDQE-0_8 Sr:20._

4 DDE-09 4

(10-54 5.81E-08 Co-18 4,1JE-08 Fe-59 B O2feQ8 i

Co-bD 1.49E-07 Zn-65 1.401-07 Sb-122 7.31E-08 Sb 116 1 02E:07 1

1-131 5.571-08 CA-13h

6. 74 E-l18 Ca-137
6. 90E-( 3 Ba.140 at35E-01 La-140 5.66E-08 Ce-141 1.00E-07 Ke-133 1 5.9E-07 Kc-135 6.01E-08 Ct-il

_,_ _ bS2E:Q7 Ee-55

-3.00E-07 C3:138 2.28E-QZ____,, _

11 - 3 7 00E-07 2

Gross. Alpha 1.01E-08 Zr:25 1.QS-01..

Br-82 L 63E-08 t

Kt-88 1J91-Q2

_ 135' 3_131E.07 -

_l-131 9.36E-08 ZEDE91/48 24 of 34

4 DRESDEN NUCLEAR POWER STATION UNITS 1, 2. AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

__ July __ Through _ December 1990 i,qdwaste LIQUID EFFLUENTS Dockee Numbers:

50-10 50-237 1.

Number of Batch Releases:

2.41E402 50-249 2.

Total Time Period for Dntch Releases:

5.85E+04 min 3.

Maximum Time Period ior a Batch Release 3.84E+02 min

!.. Average Time Period for Match Releases:

2.43E+02 min 5.

Minimum Time Period for a Batch Release:

7.00E+01 min 6.

Average Stream Flow During Periods of Release of Effluent into a Flowing Stream:

2.99E+06 L/ min CONIINUQUS MODE 3ATCil110DE NUCLIDES RELEASED UNIT 3td QUARTER

!tth QUARTER 3rd QUARTER hih QUARTER Sr:89

._ _CL

_ _Sr:9.0

_CL LO7E 0A L92E:0h_._

__.Ma:M_

JL L20E102 2 40E._0Z _

_ _Co-58

_C L b 37E10h Fe-59 JL LA7E-04 2.48E203

__._C0:00__ _ _____ _CL 4 d3E 02 L1.91-02__..

-.1n=63 AL Sb 12L__

. JL

___Sb 12h

._CL L Z 5 E.05 _ _

1:131

..CL ad1E 01 L11Er.0A_

_ _.Cs:136 _

JL

_..._Ca:131 S1_

_2135E-01

_ L 0hK-O L _

Det-lho Ci

_ _La-Uto

._C1_

___ Cs:118

..CL

. Fe 55 JL LE3E_03

___Z r:15_

_.CL 1dlE 05 Er:BL 31_

L11E-03 SL

_CL (above)

Tula LJnr_Ic.tiod___ _CL NONE

.N0 lie L9.iE-01

. __1.dBE-01 Ke:133

_CL 2.10E-01._.

._.le-133.

_CL_

L27E=03

-__lt:BB

_Ci

_LA3E:05 r

The activity of this nuclide is less than the LLD listed on the appropriate table.

ZEDE91/48 25 of 34

DRESDEN NUCLEAR POWER STATION UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

_.luly _ Thtough _Sep.tember 1990

._.RadWaste

_ LIQUID EFFLUENTS Docket Numbers:

50-10 50-237 50-249

_ _ _ _ ____ ___BATCil.M0DE_ ___..._ _ -._._... _.._...._

NUCLIDES RELEASED UNIT JULY AUGUST SEPTEMBER 3rd QUARTER TOTAL

_ Sr:8L.._._ 3L

.__S r S Q.__ _ __.. _CL 3iO4h0L.._ 2. 5 B E:0.L.___ _1 A5E_0A__.

L01E-Oh

_ _ Mn 54 CL

't,12E 03. _

___..L 20E 03--

__1.59E-Q L..._ _1.201:02

_fo-5.8

_CL

. _ = A-S L._. _. _

0L L15h05._._._1.60E105.._.._1..RBE 05 -

1.6.7h04

_._ Cod 0

_CL

_._.l.A91:0 2__

2 0.0E:02 ___ _.62ARE03 _

L13E 02

_ ltt:65

. 01..

_ Eh:122

_CL

,_ _Sh:12 L JL

-.__.I:131

.CL

__Ce:13A_

_C L ___.L 16 h0 3._

L32E103._ _ __L 29E 0!t.

-2461h03

._ Ca:13L.

CL L33E 01 J. 91k02. _.._.

_2,191:02_

2i35E101

_ _...Bn 1A0 CL La:1hD

. _.CL.

. _.00-138_.

CL

..._. l e 5 L

._C L

- 8.. 84 EDA -

I.21LQ4

_A.M E-0A._

1 33E-03 t

_.._J r:9.1

._CL

____ L1ZE-05 L5Zh05 Dr.-B1 C1._

526.2h0.6 1 10E-03.._

L51E 03 1

_CL

._CL.

(above)

IotaLforJerioL_ _CL 1.5A kO1

..__.LO8E:01

_3422hD2 _

a.91E 01

- _.le-133 0L Xc=135 31_.

i Kr.-38.

CL.

-.__2.A3E:05 22A3E-05

  • The nctivity of this nucilde in less than the LLD listed on the appropriate table.

2EDE91/48 26 of 34

=

DRESDEN NUCLEAR POWER STATION j

UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

_.0c.tcher_., Through D.ecember_ 1990

_RadEasie.

LIQUID EFFLUENTS Docket Numbers:

50-10 50-237 50-249 BATCILtt0DE NUCLibES RELEASED UNIT OCTOBER NOVEMBER DECEMBER 4th QUARTER TOTAL j

._ S.r-82

_C L

-. _ Sr:20

_CL Z..09E 0L._

4.12E 05__._ _AA0E:QL

- 1.92h04

_..Mn 5.4 JL 2 B3E-03 318hE-01

_.19.3h0L_

Rih 0E02 i

-._C0:38 01 1 E2TcQ5_

4 IRE-04 4.12E-04 2

_ Et 12

_.Ci_

5 Z.9fc0A 6425 E.-04 1.hRE-03 2 68E-03 t 60 CL 8223E-03 1103ED.2

__.itBIE-0 2 7.19fc0L

.._1tL-k1 S L.

Sb 122

. CL Sbrl24

_CL 7.75E-05.

7.75E-05

_. L-111

_Ci.-

_ _Cs:134 CL 1 3 H e.0h

.liBBE-05

._1100E-04 2 J.6E-04 1

_.Ca-137

_ 01_.

2212E:01 li.42E_02

..._.A.A2E 02 _

- 8.t0.6 E-0 2 BarlAo

_C1_

La-L40 CL

_Ce:118 C.i re-55 cL

_ 2r:95

._C L

_._Ar-32 CL

_C.L

_CL (above)

IntnLEo r_Ecriod.._. _CL 3.142E._0L _

2.RlE-02 I 24E-0.L 1 8BE-01 t

1 Kc:133

_CL 2.20E-05

.R J0E-05

_.le 135 ci._

_._1.27E.0A_

l 27E_QS

__Kr 8.B C1 The activity of this nuclide is less than the LLD listed on the appropriate table.

l' i

L l

l L

o ZEDE91/48 l

27 of 54 L

l

=

DRESDEN NUCLEAR POWER STATION UNITS 2 AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT July __ Through._D.ecembet 1990

.._ CCS.W LIQUID EFFLUENTS Docket Numbert:

50-237 50-249 1.

Number of Batch Releases:

7.30E+01 2.

Total Time Period for Batch Releases:

9.05E+01 min 3.

Maximum Time Period for a Batch Release:

1.24E+00 min 4.

Average Time Period for Batch Releases:

1.24E+00 min 5.

Minimum Time Period for a Batch Release:

1.24E+00 min 6.

Average Stream Flow During Periods of Release of Effluent into a Flowing Stream:

2.99E+06 L/ min CONIINUQUS30DE.

__BATCILMODE

.NUCLIDES RELEASED UNIT 3rd QUARTER kth QUARTER 3rd QUARTER kth QUARTER

~

Dr-89

_C L

_.-.S r -9.0._

.._C L Mu-3h

_CL 5 2hE-07 5J3E-07 10-5.8

_CL Ee-59 CL

_ _C9-60

_Ci_

1,12E-05

_ _.148E-j)5

_._2n:65.

_CL Shrl22

_.CL

._.-. Jib.124

_.01._

Id31

_.CL

_. h13 2

..CL

___.l.21E-06 _

Id35 C1 1.76E-06

- Car 13h Ci._

1.02E-05 6.d9E-07

__ Cad 31

__C1

_1,08E-05 3.19E-06

. __ Da-1A0

._C L LadhD

_CL

. __Csd 1R.

Ci Fe-15

.Ji_

.01

_CL

_Ci_.

_C1_

(above)

Io taLEo r_Ferhd._ _CL

__NONE HONE 9.87E-05

.. 2d2E-05 Xc.:133

__CL Xe-13h Cl.

  • The activity of this nuclide is lea than the LLD listed on the appropriate table.

ZEDE91/48 28 of 34 l

l

DRESDEN NUCLEAR POWER STATION UNITS 2 AND'3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

._ _.luly_ Through _ September 1910 CCSW LIQUID EFFLUENTS Docket Ntunbers 50-237 50-249 DATCIL110DE NUCLIDES RELEASED UNIT JULY AUGUST SEPTEMBER 3rd QUARTER TOTAL

__ _ Sr 89_

..C L

,._..._S r-3.0 JL 5..ZhE 07 a.2hE-07 S

_ Mn 54 JL Co 58

_CL Fe-33 JL Con 6.0_

JL 2dt9E 01_ _

_1t42E-03

.__L B1E:01.__

1.1.2Er05

_._Zn 01

_CL Sb 11L CL Sh.114 JL

_ L 131

_.CL

___IrL3 Z_

._C L

._._;I:131_

JL

_1 21Fc0L_.

It02E_05 Carl 3h

_CL L39E-06 1256E Ca-13L JL L33E:05 3.dt0Er06

._3161E.04.__

3. 08E 05

_..kL40.

AL

.._JArlh0..

_C1._.

._.fo-138

_.C L

_..J.c M

_CL

_C L.

CL

_CL 3L (above)

TotaLIor..I.eriod _. AL

_ _141E 0L__

L 91 Err 5

__2.19E 01_

__9...B ZEr05 Xe. -133 '

Ci

...CL Xe U15_.

  • The activity of this nuclide is less than the LLD listed on the appropriate table.

i ZEDE91/48.

29.ol 34 ll l

l-

. -. =

E DRESDEN NUCLEAR POWER STATION J

UNITS 2 AND 3 i

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

_Qctober Through _Densnher_1920 CCSM LIQUID EFFLUENTS Docket Numbers:

50-237 50-249 BAIClLMODE NUCLIDES RELEASED UNIT OCTOBER NOVEMBER DECEMBER hib QUARTER TOTAL St-89

_.CL Sr:20

__ _CL

-._.Mn - 5 4 CL 5,33E-07 5 83E-0.Z_.

2

__co-5.8

_CL Fe-59

_Ci

_ C.o-60

_Ci_

8 111-Q6 3 84E-06 4 2.4E-06 1 dBE-01 1

Zn-65 ci

__..._Sb - L2 2 _

._Ci_

_ _Sh:124 ci

...__.I L31

- C1

'I-132 JL

__1.J1E-06 1.21E-Ob I-u5 ci

_1.76E-06 l.ZhE-06 i

_ _Ca 13A

._C.L 6.49E-02 fur 9E10L l.0HE 07 64.11E:07 3 d2E-Ob Ca _137

_._Ci_

1 21E 06 b

13:1h0 C1 La-140 Ci

_ _ Card 8

_ CL

._ _.f.e-55

_CL cL.

ci ci

_CL (above)

I d51-06 8.08E-06 2.42E-05 IolaLEur._Enr. intl _lL 1 1.9E-05 t

Xe:133 1:L J e-135 ci-

  • The activity of this nuclide is less than the LLD listed on the appropriate table.

ZEDE91/48 30.of 34 l

l l

i

-. _ ~

DRESDEN NUCLEAR POWER STATION UNITS 1, 2. AND 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT hly Through _ December._ IMD Docket Numbers:

50-10 50-237 SULID WASTE AND IRRADIATED FUEL S!!IPMENTS 50-249 Est Tot.

Au._SOLIDJASILSti1ITED_0ffEIIE_I0lLBURIALOR_DIf 20 SAL (N0I IRRADIAIED_FUED Errot,%

1. Type of Waste Unit 6-month period m3 1.11E+02 a.

Spent resins, f11ter sludges, evt.porator bottoms, etc.

C1 2.47E+02 12.4 3

m 7.60E+02 b.

Dry compressible waste, contaminated equip., etc.

Ci 5.38E+00 16.6 3

m 0.00E+00 c.

-Irradiated components, control rods, etc.

Ci 0.00E+00 16.6 3

m 3.88E+02 d.

Other (describe)

C1 9.08E-01

2. Estimate of Major Nuclide Composition (by type of waste)

__C i n.

Co-60 9_ 9 1 _ _.2.A1EtDL Ie-B 5619

.l,A1EiOL En-E

.__31 i L._._..l.BlEf0L Ee-51

__.0s920_ _21271100_.

b1 Co _

211A ____ _LillE100_

Fe-si.

6315___. J,A REi0.0_..

Mn-54.

9,1L_ _id2E-QL Fe:5L 2dQ_._ _Ld3E-QL Ni-63 1.16__ __6. 24E-02_

d.

Co-60

__2L1 1,22E-0L Fg._55 6LO_

. 5. A5I._0L H-J

___ 4. ZL__.129E-OL ce=L31.

A35-

_Exh91-02 Ni-63 1 10 _.1.9.91-01 Sr._90 3 Q6__1 78E-02 t

3. Solid Waste Disposition NUMllELDLSilIIMENIS MODE _0LIRANSEORIAT10N DESI1 NATION I

48 Motor freight (exclusive use only)

CNSI, Barnwell, SC 12 Motor freight (exclusive use only)

Quadrex, 0ak Ridge,-TN-5 Motor freight (exclusive use only)

CNSI, Channahon, IL 3

Motor freight (exclusive use only)

Westinghouse DDR, Madison, PA B.

IRRADIATED FUEL SIIIPMENTS (Disposition)

NUMllEILDE_EllifMENIS MODLOF_IBANSIDRIAIION DESIINATlDil None ZEDE91/48 31 of 34

w

~

W,

.i '

..'I

.?

ElESDEN NUCLEAR POWER STATION c#

UNITd 1, 2. AND,3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

> le g... y '

M J.

' fin'7.

July _ Through _ December _ 199D wiag i

W Jy Docket Numbers:

50-10

i 1

.+

50-237 50-249 ABNORMAL REl. EASES i

Ai LIQUID j

1.

Number of Relet es:

O p

i 2.

- Total Activity Released:

0 w

,e

.e pp

- B.4 CASEOUS-q.

m-

-1.-

~ Number:of Releases:

0 3

q 2.,

. Total Activity R91 eased:

0-3,; n.

' j-)

f;,

4

_ du.

s a

jyy '

4% i-E Stlpm,F

TOTAL; 0

s

-a.

ccW ;

X-a,,,. t,

..s - vi, s

g i.

.+

d; 4 s

,?

y J

t 1

ni

[

'l l

,'E.'

(

s

,3;i --vg a ph'"

i I

4 a e '.

.i

,3 e

4 a

gh.

lif.

c-4 :

H.

al ?

a

, ' N L?4; j'_ ; (.y A.

_-3

.i,

f 1 \\

u>,

[3]& []! gkg.

f 7 '!

=,

~

"~

@f im 4

[f?. fj'!J.

d. i., k;,

+

s, r

'f'"

-.h'_.

+

a I b '.,..

j;t-TjM i & -

e o

I i vC t

. -.. O g-yy af p.

9:1 y

r" o j:

1 r.

g7,.

,7..

.j1 2

m

& s:m, ',

iZEDE91/48 r+

32 of 34 b;E-cm pg<,

m.

n.

19' i c'- -, :. j' i. [k I.

9fl0 I,1

.f

"..,7 j

~

4 i

4

!,1 t

i

.u,.

s DRESDDI hjLEAR POWER STATION DOCKET NOS. 50-10. 50-237, 50-249 RADIOLOGICAL IMPACT ON MAN

.t i

ZEDE91/48 33 of-34

DRESDEN UNIT ONE 1990 ANNUAL REPORT

_ MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 IFFANT RECEPTOR P

iST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BETALAIR 0.00E+00 0.00E+00 0.00E+00.

-(

)

(

)

(MRAD)

(

-)

(

)

(

)

0.00E+00 0.00E+00 (MRAD)

(

)

(

)

(

)

(

)

(

)

TOT. BODY 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 (MREM)

(

)

(

)

(

)

(

)

(

)

SKIN.

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 (MREM)

(

)

(

)

(

)

(

)

(

)

ORGAN 2.21E-05 1.73E-05 1.90E-05 3.00E-0C 8.84E-05 (MREM)

(SE

)

(SE

)

(SE

)

(SE

)

(SE

)

LIVER LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I E

INFANT RECEPTOR


 % OF' APP I.

QTRLY iST QTR 2ND QTR

-3RD QTR

'4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I i

GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00

. BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 BODY'(MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 TOT.

SKIN (MREM).

7.5 0.00 0.00 0.00 0.00 15.0

-0.00 ORGAN.(MREM) 7.5 10.00 0.00

.0.00 0.00 15.0

'0.00 LIVEK LIVER LIVER LIVER LIVER RESULTS BASED UPON ODCM1 ANNEX REVISION 0 MARCH'1989 l

l l

l

\\

DRESDEN UNIT ONE 1990 ANNUAL REPORT MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 ADULT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 (MRAD)

(

)

(

)

(

)

(

)

(

)

BETA AIR 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 (MRAD)

(

)

(

)

(

)

(

)

(

)

TOT. BODY 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 (MREM)

(

)

(

)

(

)

(

)

(

)

SKIN 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 (MREM)

(

)

(

)

(

)

(

)

(

)

. ORGAN-2.00E-05 2.66E-05 4.27E-05 4.71E-05 1.20E-04 (MREM)

(SE

)

(SE

)

(SE

)

(SE

)

(SE

)

LIVER BONE LIVER BONE LIVER THIS IS A REPCRT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I ADULT RECEPTOR

% OF APP I.

QTRLY IST QTR 2ND OTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I I

GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 l

BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LIVER BONE LIVER BONE LIVER RESULTS BASED UPON ODCM ANNEX REVISION O MARCH 1989 1^

l I

i

_~

DRESDEN UNIT TWO 1990 ANNUAL REPORT MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 INFANT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 5.91E-06 3.17E-05 9.65E-06 0.00E+00 4.72E-05 (MRAD)

(NE

)

(NE

)

(NE

)

(

)

(NE

)

BETA AIR 9.49E-07 4.52E-06 2.03E-06 0.00E+00 7.50E-06 (MRAD)

(N

)

(N

)

(N

)

(

)

(N

)

TOT. BODY 2.58E-06 1.55E-05 4.06E-06 0.00E+00 2.21E-05 (MREM)

(NE

)

(NE

)

(NE

)

(

)

(NE

)

SKIN 5.24E-06 2.77E-05 8.87E-06 0.00E+00 4.18E-05 (MREM)

(NE

)

(NE

)

(NE

)

(

)

(NE

)

ORGAN 6.25E-02 3.84E-03 9.77E-03 3.31E-03 7.91E-02 (MREM)

(NNE )

(NNE )

(NNE )

(NNE )

(NNE )

LUNG THYROID THYROID LUNG LUNG THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I INFANT RECEPTOR

% OF AFP I.

QTRLY 1ST OTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.83 0.05 0.13 0.04 15.0 0.53 LUNG THYROID THYROID LUNG LUNG l

RESULTS BASED UPON ODCM ANNEX i'

REVISION 0 MARCH 1989

DRESDEN UNIT TWO 1990 ANNUAL REPORT MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 ADULT RECEPTOR IST 2ND 3F.D 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL

.7AN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 5.91E-06 3.17E-05 9.65E-06 0.00E+00 4.72E-05 (MRAD)

(NE

)

(NE

)

(NE

)

(

)

(NE

)

BETA AIR 9.49E-07 4.52L-06 2.03E-06 0.00E+00 7.50E-06 (MRAD)

(N

)

(N

)

(N

)

(

)

(N

)

TOT. BODY 2.58E-06 1.55E-05 4.06E-06 0.00E+00 2.21E-05 (MREM)

(NE

)

(NE

)

(NE

)

(

)

(NE

)

SKIN 5.24E-06 2.77E-05 8.87E-06 0.00E+00 4.18E-05 (MREM)

(NE

)

(NE

)

(NE

)

(

)

(NE

)

ORGAN 6.35E-02 4.30E-03 1.14E-02 3.37E-03 8.16E-02 (MREM)

(NNE )

(NNE )

(NNE )

(NNE )

(NNE )

LUNG THYROID GI-LLI LUNG LUNG THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I ADULT RECEPTOR


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0,00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.85 0.06 0.15 0.04 15.0 0.54 LUNG THYROID GI-LLI LUNG LUNG RESULTS BASED UPON ODCM ANNEX REVISION O MARCH 1989 I

DRESDEN UNIT THREE O

1990 ANNUAL REPORT MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/25/91 INFANT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 4.73E-05 1.83E-04 8.62E-05 5.50E-05 3.71E-04 (MRAD)

(NE

)

(NE

)

(NE

)

(NE

)

(NE

)

BETA AIR 7.59E-06 2.32E-05 1.82E-05 1.60E-04 2.07E-04

-(MRAD)

(N-

)

(N

)

(N

)

(NNE

)-

(NNE )

TOT. BODY 2.07E-05 9.21E-05 3.62E-05 2.29E-05 1.72E-04

.(MREM)

(NE

)

(NE

)

(NE

)

(NE

)

(NE

)

SKIN 4.19E-05 1.58E-04 7.92E-05 1.63E-04 4.41E-04 (MREM)

(NE

)

(NE

.)

(NE

)

(NNE i (NE

)

ORGAN 8.34E-03 1.92E-02 4.93E-02 5.64E-03 8.22E-02

-(MREM)

(NNE )

(NNE )

(NNE )

(NNE )

(NNE.)

LUNG THYROID LUNG THYROID THYROID THIS IS A REPORT FOR THE CALENDAR YEAR 1990 O

COMPLIANCE STATUS - 10 CFR 50 APP. I INFANT RECEPTOR


^------ % OF APP I.

QTRLY~ IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF DBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I GAMMA ~ AIR (MRAD) 5.0 0.00 0.00-0.00-0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT.' BODY (MREM) 2.5 0.00 0.00 0.00 0.00=

5.0 0.00 SKIN (MREM) 7.5.

0.00

-0.00 0.00-0.00 15.0 0.00

. ORGAN (MREM)

7. 5-0.11 0.26 0.66 0.08 15.0 0.55-2 LUNG

. THYROID.

LUNG THYROID THYROID RESULTS BASED UPON ODCM ANNEX

. REVISION O MARCH 1989 O

DRESDEN UNIT THREE 3

\\>

1990 ANNUAL REPORT MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PEPIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/25/91 ADULT RECEPTOR iST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 4.73E-05 1.83E-04 8.62E-05 5.50E-05 3.71E-04 (MRAD)

(NE

)

(NE

)

(NE

)

(NE

)

(NE

)

BETA AIR 7.59E-06 2.32E-05 1.82E-05 1.60E-04 2.07E-04 (MRAD)

(N

)

(N

)

(N

)

(NNE )

(NNE )

TOT. BODY 2.07E-05 9.21E-05 3.62E-05 2.29E-05 1.72E-04 (MREM)

(NE

)

(NE

)

(NE

)

(NE

)

(NE

)

SKIN 4.19E-05 1.58E-04 7.92E-05 1.63E-04 4.41E-04 (MREM)

(NE

)

(NE

)

(NE

)

(NNE )

(NE

)

ORGAN 8.41E-03 2.18E-02 5.79E-02 6.65E-03 9.25E-02 (MREM)

(NNE )

(NNE )

(NNE )

(NNE )

(NNE )

LUNG THYROID GI-LLI LUNG GI-LLI THIS IS A REPORT FOR THE CALENDAR YEAR 19!0 0

COMPLIANCE STATUS - 10 CFR 50 APP. I ADULT RECEPTOR


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.11 0.29 0.77 0.09 15.0 0.62 LUNG THYROID GI-LLI LUNG GI-LLI RESULTS BASED UPON ODCM ANNEX REVISION 0 MARCH 1989 Ob

- - - _. -. -... ~.

DRESDEN UNIT TWO 4

-INFANT RECEPTOR 1990 ANNUAL REPORT MAXIMUM DOSES (MREM) RESULTING FROM LIQUID EFFLUENTS PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.33E-05 1.05E-04 2.24E-04 1.16E-04 4.98E-04 BODY INTERNAL 1.87E-04 1.02E-03 2.19E-03 9.02E-04 4.31E-03 ORGAN s

LIVER LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I

% OF APP I.

QTRLY iST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN Jfw-SEP OCT-NOV OBJ APP.I TOTAL BODY.(MREM) 1.5 0.00 0.01 0.01 0.01 3.0 0.02

.CRIL, ORGAN (MREM) 5.0 0.00 0.02 0.04 0.02 10.0 0.04 LIVER LIVER LIVER LIVER LIVER RESULTS BASED UPON ODCM ANNEX REVISION 0 MARCH 1989

.=.- -

~

DRESDEN UNIT TWO INFANT RECEPTOR 1990 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.33E-05 1.05E-04 2.24E-04 1.16E-04 4.98E-04 BODY INTERNAL 1.87E-04 1.02E-03 2.19E-03 9.02E-04 4.31E-03 ORGAN LIVER LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.012 BODY INTERNAL 4.0 (MREM) 0.108 ORGAN LIVER THIS CALCULATION OF DOSE IS LASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON ODCM ANNEX REVISION 0 MARCH 1989 t

DRESDEN UNIT TWO ADULT RECEPTOR 1990 ANNUAL REPORT HAXIMUM DOSES (MREM) RESULTING FROM LIQUID EFFLUENTS PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.06E-04 1.84E-03 4.01E-03 1.61E-03 7.76E-03 BODY

. INTERNAL 4.54E-04 2.78E-03 6.06E-03 2.44E-03 1.17E-02 ORGAN LIVER LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I

% OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I TOTAL BODY (MREM) 1.5 0.02 0.12 0.27 0.11 3.0 0.26 CRIT. ORGAN (MREM) 5.0 0.01 0.06 0.12 0.05 10.0 0.12 LIVER LIVER LIVER LIVER LIVER RESULTS BASED UPON ODCM ANNEX REVISION O MARCH 1989 l

l

DRESDEN UNIT TWO ADULT RECEPTOR 1990 ANNUAL REPORT PROJECTED DOSE AT NEAKEST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/90 10 12/31/90 CALCULATED 02/22/91 IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC

-TOTAL 3.16E-05 1.29E-04 2.80E-04 1.16E-04 5.56E-04 BODY INTERNAL 3.88E-05 1.86E-04 3.93E-04 1.62E-04 7.77E-04 ORGAN BONE LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.014 BODY INTERNAL 4.0 (MREM) 0.019 ORGAN LIVER THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON ODCM ANNEX REVISION 0 MARCH 1989 1

DRESDEN UNIT THREE INFANT RECEPTOR 1990 ANNUAL REPORT MAXIMUM DOSES (MREM) RESULTING FROM LIQUID EFFLUENTS PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 9.45E-05 1.05E-04 2.13E-04 7.77E-05 4.90E-04 BODY INTERNAL 3.51E-04 1.02E-03 2.12E-03 6.02E-04 4.09E-03 ORGAN LIVER LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I

% OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I TCFAL BODY (MREM) 1.5 0.01 0.01 0.01 0.01 3.0 0.02 CRIT. ORGAN (MREM) 5.0 0.01 0.02 0.04 0.01 10.0 0.04 LIVER LIVER LIVER LIVER LIVER RESULTS BASED UPON ODCM ANNEX REVISION 0 MARCH 1989

!~

t

DRESDEN UNIT THREE INFANT RECEPTOR 1990 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 9.45E-05 1.05E-04 2.13E-04 7.77E-05 4.90E-04 BODY INTERNAL 3.51E-04 1.02E-03 2.12E-03 6.02E-04 4.09E-03 l

ORGAN LIVER LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.012 BODY INTERNAL 4.0 (MREM) 0.102 ORGAN LIVER 0

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON ODCM ANNEX REVISION 0 MARCH 1989 l

l

DRESDEN UNIT THREE ADULT RECEPTOR 1990 ANNUAL REPORT MAXIMUM DOSES (MREM) RESULTING FROM LIQUID EFFLUENTS PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.83E-04 1.84E-03 3,86E-03 1.07E-03 7.36E-03 BODY INTERNAL 8.66E-04 2.78E-03 5.84E-03 1.63E-03 1.11E-02 ORGAN LIVER LIVER LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 10 CFR 50 APP. I

---~~~------ % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-KAR APR-JUN JUL-SEP OCT-NOV OBJ APP.I TOTAL BODY (MREM) 1.5 0.04 0.12 0.26 0.07 3.0 0.25 CRIT. ORGAN (MPEM) 5.0 0.02 0.06 0.12 0.03 10.0 0.11 LIVER LIVER LIVER LIVER LIVER RESULTS BASED UPON ODCM ANNEX REVISION O MARCH 1989 l

l

i DRESDEN UNIT THREE ADULT RECEPTOR 1990 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/90 TO 12/31/90 CALCULATED 02/22/91 IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC

' TOTAL 5.80E-05 1.29E-04 2.69E-04 7.74E-05 5.33E-04 BODY INTERNAL 7.46E-05 1.86E-04 3.78E-04 1.08E-04 7.40E-04 ORGAN BONE LIVER LIVER LIVER LIVER

~THIS IS A REPORT FOR THE CALENDAR YEAR 1990 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.013 BODY INTERNAL 4.0 (MREM) 0.018 ORGAN LIVER o

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON ODCM ANNEX REVISION O MARCH 1989 l

- __= _. _

_. =. _.

O DRESDEN NUCLEAR POWER STATION DOCKET NOS. 50-10, 50-237, 50-249 i

METEOROLOGICAL DATA l

i I

l ZEDE91/48 34 of 34 ll-

-, - 1.,

-a

,.w m

(f(c tilith $111!04

-hl ItttttW 1950 f

300 f t, till 181l0 att I!te tilltf t:4 200 35 fl. t!!T!!!Olit fis8(14fa[

6.:'ulit of C!!ItVAtitt! 2201 Itail All PIR In1 C:MIB t Iogig

..................................:3333;;1;;gg333[3..................................

Citll h

n!

n! It!

($1 Il lli i

lis le til i Its kt 641 1 CIA' IV NJ lv n il rl il 10ilt

........ 3143n;ty g353g3..........

19.00

.00.00.00.00.00.t0

.C0

.00.0;.CO.00.C0.tl.C0.00

.00.00 kJ.00.00

.t0

.t3.t0.00.tl

.tc

.00.00.00.00.00.t0.C0.00

.00

.tt CIV.00.t0

.00

.t0.02.00.00.Ct

.00

.00.00.tt.00.00.00.tt

.00

.tt A t.C0

.00

.00

.C0.C0

.01.tl.00.t0

.00.00.00.00.00.te.00

.C0

.00 til.t0

.00

.00

.00.00

.ft.00.00

.00.00.00.00.f0.00.00.00

.00

.00 I #3.50

.C0

.it.00.00.to.00.00

.00

.t0.to.00.00

.00.00.c0

.00

.c0

!!.0:.te.00.C0.40

.00.00.00

.00.it.00.00.t0.00.00.00

.00

.00

.CC IV.t0.tl.00.tl.00

.00.00

.00

.t3.t:.00

.t

.St.00.00.00

.00.C0 KJ.0!.00.50

.00.C0

.00.00.00

.00.00.00.it.td.00.00.00

.00

.t0 IIJ.00

.00.00

.00

.C0

.C0.00 00.0t.00.00.t0.00.00.00

.C0

.00 I.tl 14

.21

.Il 14.34.tl

.L 14.tl 18.te.03. Il. tl.23 2.54 2.l4 3 II.05

.tl.tl

.tl.27.41 11

.t,

.05

.tl.t1.tl.01

.14 14.00 f.54 1.14 85.tl.03.05

.Cl.05.tl.00.00

.t1.02.00.00

.55

.00.t0

.00

.O

.43 II

.09

.00.50.00.t3.50.00.te

.00.00.to.Cl.CC.45.00,05

.23

.23 1.11 19.00.00.00.C0.00

.00

.00

.00

.00.00.00.00.00.00.40.00

.00.C0 NV.00

.00

.00

.00.00.00

.tt

.00

.te

.50.to.00.00.00.00

.40

.t

.00 4$U.00 =.00.tl

.00.00

.00.C0

.44

.00

.40.00.00.40.00.01.00

.01

.01

  • I

.38.51.51.32.50.50

.73

.51

.35

.if.it.15.ll.22.31.32 8.72 1.12 iil

.fi

.50.51.42.31.35.21 45

.21

.44 41.00.23.23.Il

.8) 3.12 5.72 NI.C0.01.05 14.Cl.45.01.01

.01.51.32.2f.50

.11

. Il

.H 2.73 2.13 il.tl

.05.01.81.00.00.00.00

.C0.00.00.40.45.00.01.09 41

,45 11.12 10

.0)

.!3.00.00.00

.00.00

.00

.00

.40.00.50.00.00.00.00 14

.14 n2

.id

.41

.01

.00

.00

.00

.00

.00

.00

.00

.00.00.00

.tl.00.00

.l4

.14 8 37.31

.Il

.05.05.00

.00.01

.I4

.00

.00.00.01.t1

.00.!?.01 1.27 f.21 4.Il.38

f. Il

.54 44

.44

,f3 1.50 1.11 1.32 1.t0.l1.53

.44

.44

.35 14.04 14.04 I$$.55 1.14 2. f 4 t.23 f.04.32.71 f 82.42 1.45 1.00.51

.41

.32.!!.32 11.12 li.13 2 #1

.t4 431

.tl

,tl,23

.tl.32.32

.35.32.31

.43

.38 18.22.00 4.04 4.04

!$. 0$.!1.00.00.00.00.CC -.00

.05

.01.00.00

.0)

.t4

.00.03

.50

.53 35.fi t.

(4

.50

.00.0C

.00.!!

.00.00.00

.00

.00.00 00.00.00.00.00

.00.tt l'

. t r;

.11

.ll

.00

.00

.t0

.00.tl

.00

.to

.00.C0

.c0.00

.00.01.33

.it

.it 3 IV 18

.0 14

.00

.50

.00

.00

.51

.01

.C0.05.05.00 00

.14

,01

.42 4

.tl I.tl 1.51

.fi

.31 41 73 t.tt 1.00

1. 2

.31

,1)

.2) 4f

.41

f. T' l.12

[

t il

.50.2.00 1.38

.27.59

.45 1.11

f. t d ~ ' 11 t.12 2.01.51.23.15.12.23 4.72 ti.12 l

8 85

.id 45

.01 05.01.23

.8) il

.41

.!O

.it

.23.32

,14 11 4.!!

4.11 Il

.01.Cl

.00.00.00. 00.01.05

.0)

.40,00 Al.23

.tl

.01.ll 1.04 1.14 32.33 l'

1

.X f

l.

tite tilltit statt3 Mf'lH1'"P 'N i

300 f t th0 l'iit 4*d thD t'titi!3 00'31 f t (WIU4H'! II"IMI

.1 p!!D --

  • - t h0 M titil04 ti A13Il ~'*** ~~ ~~" * ~ " "~

l' Alh!M tilllll ~" ""

(tall 84 ul kl iki i

I!!

Il !!!

1 Ill 18 til I tu u au Tc?At (W

N ly 4

II H H M IU

.t

.tt

.00

.to.t;

.00

.00

.t0

.00

.t0

.t0

.00

.Ct

.00

.0t

.00

.It

.00 t WV 30

.t!.t0.t0.00

.00

.00 J0

.t0

.H

.t0

.H JO JC 30

.H Cl Cl iIV.tl

.H

.t0.t0 J0

.00

.H

.00

.14

.t

.!!.tl JC

.H

.tl.!!

J!

dl 4

.tl

.23 J!

.H

.tl

.C0

.H

.00

.H 32.!1

.!? JC

.18 Ji.!! 1.11 1.13 2!!

.tl

.50

.11

.00

.00

.tl J5

.C0

.ll

.fi

.64 J4.ts 14

.51 J! 4.11 4JI 4v3

.rl

.!)

.H

.H

.H

.00

.t!

.tl

,14

.41

.31

.cl

.00

.tt

.t0.!! 1 41 IJf II

.Ct

.H

.00 at

.H JC.tl

.Cl

.00

.00

.tl

.00

.00

.Cl

.H Ji J2 A2 1.31 IV

.0*

.tc

.H

.00.t!

.C0.t: J0

.40

.00

.H

.H

.00

.00 JC

.H

.00 JO t KV

.0

0

.H

.C0

.00 40

.H

.C0

.H

.H

.CC

.00 JC

.00

.H 10

.H

.00 I la

.C0 JO.t0

.00.t0

.00 JO

.00

.t0

.00

.00.ts

.H

.00

.H

.t0

.00

.00 h

.H

.tl.Cl

.H

.H

.H

.00.to

.H

.00

. t4 JC.00 14 to

.41 dl

! Il 40

.t1

.!!.!0.00

.00.00

.00

.H

.tl

.Cl.!!

.55

.tl 14.!!

.46 Ji 483

.t0

.H

.00.00.CC

.H

.tl 00

.tt

.C0

.H

.t0 JO.t0

.H

.C0

.00 J3 il JD

.C0

.00

.00

.00

.H

.00

.50

.H

.C0

.00.00

.t!

.t0

.H

.00

.H

.H

.14 101 4.41 f.tl I.C4 4. fi 4.04 3.51 IJO f.43 I Q1 It.11 f.II l.!! 3.15 1.11 l.14 til 100.00 14 1.H f.14 37,44 H.?! TH Ll4 IM.00 114 Dire:11:n nr $tilility a

ut ni DI i

!! $11 1

$11 11 tiv I sti u 60 filat lfath!!YCLA!!!!-

.H

.05

.00

.00

.t0

.00

.00 AC

.00

.H

.H

.H

.H

.C0.ta 30

.14 littenir Unstule

.32

,10

.O

.t? JO

.H

.!C

.00

.H

.H

.cl

,H

.00

.00

.H

.H I.01 0: erat:1r tutnit

.ll 18

.!)

.05

.H

.01

.23

.23

.t0

.tl. Il.00

.00.50.!! !.14 1111911; Westn't t.35 3.04 4j0 t.!! tJI 1.51 1.17 3.M 3.48 3.50 3 45 Lil I.34 1.14 1.11 1.14 31.44 tedral I.31 4.fi 4.!! 2.41 -2.!! 1.15 !.15 L50 3.fi 4.12 4.!! t.33 1J0

.11 t.t4 1.04 41.11 llilitly Itale Ji

1. 'l di.32

.41

.41 1.H

.l4 1.01 1.l! 1.11 t.00 1.23

.8)

J!

.!! tL40 oceratal; 1:nle

.32 23

.t1

.4 30

.H 14

.01

.14

.tl

.01 14

.31 Ji 14

,17 2.54 littenir $tnie liRd Otteettet er 1141:tti t

ui 4! It!

I fil if !!!

$ ll

$1 v!: I tu 4: ut 70fal IM) $7([$ tiAll[l-

.t0

.G

.t0

.H

.H

.C0.tc

.H

.H JC

.00.t0.00

.00

.0;

.00

.H t4ta

.32

.13 31 Ji

.45

.50

.2f

.if 18

.!!.01

.!)

JI.32.!? - 4.0 1.0 1.5 s:t

.51 1.23 1.32 1.31

.it 1.H 1.0 1.14 1.32 2.00 1.32.12 1.45

.f3

.12

.35 11.12 1.5 f.5 8:*

!.H 3.51 LI) 1.11 1.11 t,14 ?.11 3.!? Lli 3.13 !.38 1.11 1.31 1.!! t.50 t.H 35,74

!.I 12.5 : 9 1.27 3J! 3J1

.50

.73 71 bli Lil 3.53 1.32 4.31 1.12

.11

.14 1.12 1.cl 12.53 11.1 18.5 nm

.!) tJ3.50

.H dl

.Cl

.01 al 1.to 1.50 1.32.55 J0

.50

.42.Il I31 11.1 14.1 na

.00

.14 J!

.0

.00

.H

.H

.M

.00 M al Ji.tl

.H

.H

.48

) 24.5 r:9 1

i

._,____m._-----s-

- - - - - - - - - - - - ^ - - - - - ^ - - ' ' ^ ^ - - - - " - - - ~ ' " - ~ ~ -

~~

1 t!:e (flDin $!stlM tc!ctt"It:mte 1910 Mt f t. I!O l'i!! 14 t!O !?!t!!04 3M 35 f t !!Ultini!AL !! Dita 1Uti talil Of Cl:!hatun! : !)4) 11W!! 18! Pit:Inf t htt!n:I Ir!!D

-. - g l C 11:10 !! % (; 41 $11 ------~ ~ ~- ~ ~ --- - -

~~ - ~ IT411t!11 Cla!!!! - - -

CLU! n Att ni Int I

ill if $ll l 531 11 til I Int ha hl 10?ti D

8.i

$G n

!! O Il 101&L l.!

.O

.00

.8

.00

.t0

.H

.to

.O

.0

.t;

,H

.00

.M

.t0 80

.t3

.t3

.0C N

.00

.!0

.H

.00

.H

.t0.00.t0

.C

.H

.t2

.M

.N

.00.tl

.00

.00

.00 C12

.O

.C0

.M

.t0

.H

.H

.O

.t

.t

.t0

.M

.O

.00

.00

.H

.t0

.t0

,tc 4 a

.N

.M

.t0

,c t

.n

.t3

.00

.tt

.t2

.tc

,n

.O

.t;.00

.00

.00

.H

.t!

lil.t3

.t

.R

.C0.tl.00

.H

.t0

.CO

.H

.N

.N

.C)

.t0

.00

.tl

.tl

.tl 84

.00

.00

,M

.00

.H

.00.00

.t0

,H

.0

.0C

.it.t0

.00

.00

.M

.H

.H il O.00

.M

.00.00

.H

.00

.00

.t

.00

.00

.H

.M

.Ct

.to

.C0

.C0

.00

.Cl R

.H

.O

.H

.00

.M

.00.C0

.00

.t0

.P

.tl.00

.8

.CO

.ta

.H

.00.00 N. !).t:.0;

.M

.00

.00

.M

.00

.00

.00

.M

.H

.M

.H

.tc.ta

.H

.00 t $J

.M

.to.t:

,tt

,tt

.H

.t0

.0

.M

.00

.00

.M

.t3

.H

.t0

.t2

.H

.t0 4

.tl

.H

.0

.H 14

.00.00

.H

.01 14

.tl

.14

.tl

.00

.Cl

.11

.11 3II

.M

.M

.05.t0

.01

.00.tl

.tl

.1

, t4

.tl

.t)

.e5.t0.05

.Cl

.85

.Il C

.H

.H

.0)

.t0

.05

.00

.0)

.11

.01

.00.00

.H

.05.t0

.05

.H

.50

.40 il

.M

.00

.H

.05

.00

.H

.to

.t5

.H

.00

.0

.CC

.00

.ta

.H

.M

.ti

.14 2.37 h

.4 -.t3

.C)

.f0,t3

.H

.tc.t3

.00

.00

.H

.O

.0

.00

.00

.00

.tc

.tl N.C0

.C 0

.O

.C0

.00

.it

.3

.t0

,H

.00

.t0.00

.H

.00

.t0

.to

  • 0

.00 4h.05

.H

.M

.M

.t0

.C0.t0

.00

.O

.t0

.t

.90

.H

.00.00

.tl

.01

.t!

4

.t4

.f 4

.H

.H

.01

.11

.28 41

.33

.7)

.37

.37.55 11

.51

.33 4.4!

4.42 7 II

.C)

.05

.11

.H

.cl.01

.14

,tl

.01

.D

.tl

.cl

.14 11

.01

.M

!.H t.H 8; 03

.H

.tl

.00

.23 14.!I

.11

.Il

.00

,tl

.14

.tl

.Il

.14 14 1.41 1.11 il 01

.M

.N

.M

,H

.t0

.tl

.01

.01

.H

.Cl

.M

.40.00

.C0

.00

.H

.10 8.13

~

fil.C0

.M

.M

.00.to

,tl

.00

.H

.0

.00.to.00

.t0

.00

.00

.00

.tl 8J.Cl

.M

.0

.it

.0

.0

.00

.CO

.H

,CO

.4

.00

.9)

.00

.Cl.00 14

.14 8 $J.tl

.O

.M l0

.00

.M

.M

.00

.O

.M

.t0

.00.00

.H

.C0

.H

.14

.t4 9

.14

.00

.14

.31

.14

.50

.f4 1.0!

.13

.44

.it

.l.

.60

.f 4

.fi

.11 8.70 1.70 I il 41

.47

.I4

.14

.tl

.11

.28

.11

.50

.47

.tl 1.lf 47

.70

.33 f.H f.03 IC

.37

.01 11

.05.01 14

,14

.13

.H

.41

.23

.51

.21

.2)

.37

.it 3.58 3.11 Il.!!.!!

.01.to

.O

.M

.tl

.Il

.05

.M 14

.D

.00.03.00

.01 1.M l.20 N.Il -

h

.M

.H

.0

.D

.H

.M

.O

.M

.4

.M

.M

.40.C0

.0

.00

.0

.H

.CC tN 14

.M

.t0

.O

.M

.00

.M

,t0 M

.M

  • 0

.):

.t!

.O

.00

.JJ

.D

.!)

3 IJ

.t4

.c0

.M M.c0

.tt

.C0

.00

.G

.05 0"

.M M.cl.tt

.D

.51

.51

.1) 47 41

.01

.23

.il 1.it

.l4

.11 'D

.li 1.0 1,5l

.51

.!! 13.41

13. 0 t il.21

.7)

.I' 42.!!

.ll 1.ti 1.07 ' 11 1.Il to

.f t 1.D 31

.it t.21 11.47 14.47 iC

.M

.14

.M

.H

.cl

.14 74

.D 01

.4f

.?3

.D

'I 14

.H 42 4,11 4.21

. Il

.l

.H

.G

.H

.40

.H tl

.M

.M

.tl

.2) 14 0

.M

.00

't

.11

.H 31.12

'l CitetRillin5tA11h 0:tner tecenter 1190 m f t. IN IPii0 sof IN C:lleilh 300 31 f t, ClffilittlAt fis?inisti pill.................................. y m 0 3g;t:3 g93$13.......................-..........

......... Iuth!H ta!!!! -

Ciell t ul ni IW! !

Ill il lli i

lit li eli i

un u ut 10 fat EW #J ly k ll F5

!! fifil IU.00

.c4.00.00.00.00.00.t0.40.00.00.00.00.00.00.00

.00.00 i NJ '.00

.00.to

.00.ft.C0.00

.00

.00.00.t0.00.00.40

.00

.te

.00

.00 1 IJ.00

.C0.t0

.tc.00

.00.00

.tl.tl

.00

.tt.to.tl.t0.00.to

.01

.tl t.23

.51

.33

.14

.tl

,il.05

.41

.51

.31 1.01 11 1.16.44 14 14 1.11 1.1)

! Il.05

.53.23.00

.C0

.00

.37 1.11 f.00 3.11 1.11.70.10.51

.Il 14 11.40 11.40 4 #5.33

.00 -.00

.00.t0.25 14

.00

.14

.33.37.37.C0.01.01

!.01

!.Cl

!!.tl

.00.40

.00.50.00.tl

.00

.00

.01.cl.tl

.00.00.tc.05

.21 10.15 (Y.00

.00.00

.00.00.00 '00.00.00.00.ts.00.t3.00.ca,te

.00.00

$WJ.00

.C!.00

.c0.00.t0

.00

.00

.00.00

.f 0.00

.00.00

.00.00

.c0

.c4 1 l'J.00

.c0.to

.tl.t0

.00

.c0

.00

.00.C0.t0.00.C#.00.t0

.00

.00

,00 A.05

.00.00

.fi.tl

.05.t0 14.33

.!4

.38.33

.7) 74.15.00 4.11 4.11 Iil.cc

.45.c0

.01.fl,te.00

.31 1.88 1.11,21.23 47

,14

.Il.ta 1.10 1.10 4 83.00

.00.t0.00.C0.C0

.00

.c0.00.05.00.00.to.00.30.00

.tl

.tl El.00

.00.00

.00.40.00

.t

.00.00.00.t0.00

.00

.00.00.00

.00

.00 11.03 fat 3.54 4.14 1.11 2.00 f.ll - 3.41 1.49 8.7010.11 11.81 f.83 1.14 1.84 l.fi 1.35 1.21 100.00.c0.31.11 31.!!.3.74 11.42 3.!! Itt.t!

vind Dire:ttaa 6; Itaility.

E HI al it!

E!!

If Ill 8

Ils II sit I

tu ni us 10 fit liAi!Liff ctillil-

.00

.00.00.00.00.00

.00-

.00.00.00

.04.40.00.00.40

.00

.00 Entresel; Untitle

.23

.40.60

.00.00.00.00

.C0.00.00.00.00.00.50.05

.09

.31 pacerstel tastille f

.!3

,00

.00.00.t0

.00

.00

.tl.01.01.00.00.00 '.t5

.t 41

.44 il199ti; Vast 401s

.71 1.!!.!!

.93

.74 f.Il 1.51 3.11 3.02 2.!! 4.11 f.05 4.11 5.!! 3.18 1.31 31.37 tratt:1

.14 1.21 1.12

.51

.51 1.18 !.05 3.51 1.38 1.11 3.30 2.33 3.13 f.!I~l.il 1,81 43 !4 stilit1; It:31s l'

l.01

.33.3!

.05.31

.41 1.40

.54

.50

.93 t.31 1.31

,16.51

.98 1.11 11.42 saferets); itsele

)

.31

.33 14

.05

.00

.00

.41

.33

.14

.!3 47

.42

.00.t0

.00

.25 3!

Entresel Italte f

t ll I

- visilire:tica at tied 1;tet I

4 ul E! Egi i

Ill li 18!

$ liv if til t

its it ut Titel 810 IFlia tiAllil-

.00

.00.C0.nl.05.cc.ca.c0

.00

.e4.03.c0.00.00.e0.el -.ti tat l

.45

.0)

.t!

.01.23.00 11.!!.23.li

.il

.0)

.23.01.01.01 1.31 1.0 3.5 sai

.31

.!!.33

.51

.42 42

.51 74.11

.)I

.f 0.13

.14

.42

.74

.51 1.13 1.1 1.5 m 1.12

.34

.59

.56.li

.93 1.25 1.31 1.11 I.40 1.35 1.Il f.15 1.44 1.11 1.30 20.11 f.I.11.5 ;t f.li 1.44

.Il

.51

.51 1.00 1.11 1.!! 1.75 4.00 3.13 1.!! l.79 3.?! !.t! l.fi 35.!!

12,8 11.5 rp 70 1.44

.35 14

.C)

.0)

.li t.it 2.70 3.11 2.14 1,30 1.86 1.41 1.!!

.51 20 !!

11.8 14.3 m

.01

.05.t0

.14..01.01

.00

.51 1.11 f.70 1.11.51 1.25.45 1.30.00 11.03

> 24.5 m

. ~ - -... -

=

t ATIACllMERLA I

ICLReY1mion_2 J-s k

e t

i

(

i -

l-1.

j l.

I '.

l i

-m

DRESDEN NUCLEAR POWER STATION ASSIGNMENT FORM Assigned Review Number 90-2LReyhed Ti!E SUBJECT TO BE REVIEWED:

Revisions of the Unit 2 and 3 Technical Specifications Sections 1.0, 3/4.2, 3/4.8, and 6.0 to conform to NRC Generic Letters 89-01 and 89-14.

Revisions to Offsite Dose Calculation Manual and Process Control Program to conform with NRC Generic Letter 89-01.

PERSONNEL ASSIGNED TO PARTICIPATE IN Tile REVIEW AND INVESTIGATION:

M. Strait.....

NPPT. MGES

_L _Sacroman.do RS Name Discipline Name Discipline L, Gerant Nff.I..J%ES

.D. Gulaki IkC_fihES

.Name Discipline Name Disc 1pline L_ Smith D PT. RO. MkES

_Tu_3hiliga CJI Name Discipline Name Discipline TIIE DATE Tile REVIEW IS TO BE COMPLETED:

ftepirmb.cr_21. _1220

~

(

tion / Manager Date Assignment Made Junn_2L_.1930 DISCIPLINES:

NPPT - Nuclear Power Plant

- Chemistry Technology

-R0

- Reactor Operations

- Instrumentation and Control RE

- Reactor Engineering M&ES - Mechanical and Electrical Systems RS

-- Radiological Safety (Form 10-1A)

ZR18/272

~,

. ~. ~.

DRESDEN ON-SITE REVIEW REPORT FORM Assigned Review Number 90-2L SUBJECT OF REVIEW Revisions of the Unit 2 and 3 Technical Specification Sections 1.0, 3/4.2, 3/4.8, and 6.0 to conform to NRC Generic Letters 89-01 and 89-14 Revisions to Off-Site Dose Calculation Manual-and Process Control Program to conform with NRC Generic Letter 89-01.

FINDINGS AND RECOMMENDATIONS: See Attached l

Yh WRITTEN BY

??7d Mar.M 2#/* #fsES 9/M

  • 7. 2:C, 4 f,,ES 9-19-90 PARTICIPANTS:

(//

m C#

20-W (T. N 4 ES l

M&(20*YO f

Sta MauIder Date Review Completed 9 Y/'90 Attachments:

Report sent-to:

'.(1) The Vice President BWR Operations,-

(2) The Superintendent of the Off-Site Review Function, (3) The Assistant Vice President.-of.. Quality Programs and Assessment, j

-(4) The Nuclear Licensing Manager, (5) The Dresden-Ret,ulatory Assurance Supervisor, and

~

-(6) The On-Site Review Requestor.

/(vis-Q0 Theoriginalhasbeenfile&.tg)%k>-cao d

Signature /Date (Form 10-1B)

/

f()-

'ZR18/272

EindingE_and._Recotmnendettions A revision to Unit 2 and 3 Technical Specifications is being proposed as part of the Dresden Station Improvement Program Technical Specifiention Action Plan.

Specifically, the technical specification changes are directed by NRC Generic Letter 89-01.

Contained in this package are also Revision 0. A of the Of f site Dose Calculational Manual (ODCM) and Revision 2 of the Process Control Program (PCP).

The changes in Technical Specif*. cations Sections 1.0, 3/4.2, 3/4.8, and 6.0 involves transfer of text to the ODCM, and PCP.

The new ODCM Chapter 12 uddition is present in both references to facilitate use.

A discussion of the changes proposed follows this section.

Attachment A contains a summary of changes. Attachment B contains the proposed changes to the Technical Specifications.

Attachment C contains ODCM Revision 0. A. Attachment D contains PCP Revision 2.

Attachment E contains the Evaluation of Significant Har.ards Considerations.

Attachment F contains station procedures and FSAR sections that will require revision to reflect the changes contained in this package.

t.ttachment G contains a copy of NRC Generic Letter 89-01.

The review participants find that the changes identified herein do not represent an unreviewed sefety question.

The review participants recommend these changes be incorporated accordingly.

NRC_ Genericle11ern_E2-QLand_E9_-lh The changes represent editorial transfers in accordance with NRC generic Letter 89-01 with exception to the surveillance interval text.

The surveillance interval change is directed by NRC Generic Letter 89-14.

There are no technical changes associated with this ODCM revision.

ODCM Revision 0.A maintains the level of radioactive control required by 10CFR20.106, 10CFR Part 190, 10CFR50.36a and Appendix I to 10CFR Part 50.

It does not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations.

ZR18/272

-