05000324/LER-1982-142, Forwards LER 82-142/03L-0

From kanterella
(Redirected from ML20028F355)
Jump to navigation Jump to search
Forwards LER 82-142/03L-0
ML20028F355
Person / Time
Site: Brunswick 
Issue date: 01/17/1983
From: Dietz C
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20028F356 List:
References
BSEP-83-144, NUDOCS 8302010267
Download: ML20028F355 (1)


LER-1982-142, Forwards LER 82-142/03L-0
Event date:
Report date:
3241982142R00 - NRC Website

text

,

p-Carolina Power & Light Company r1

=.4-y.m m,

mg:m Brunswick Steam Electric Plant ao P. O. Box 10429 Southport, NC 28461-0429

~5

.,3 a

January 17, 1983

$a' i ',qh FILE:

B09-135100 3

~

SERIAL: BSEP/83-144 Mr. James P. O'Reilly, Director 6

U. S. Nuclear Regulatory Commission Region II, Suite 3100 101 Marietta Street N.W.

Atlanta, GA 30303 BRUNSWICK STEAM ELECTRIC PLANT,. UNIT NO. 2 DOCKET NO. 50-324 LICENSE NO. DPR-62 LICENSEE EVENT REPORT 2-82-142

Dear Mr. O'Reilly:

In accordance with Section 6.9.1.9b of the Technical Specifications for Brunswick Steam Electric Plant, Unit No. 2, the enclosed Licensee Event Report is submitted. This report fulfills the requirement for a written report within thirty (30) days of a reportable occurrence and is in accordance with the format set forth in NUREG-0161, July 1977.

Very truly yours, i-J C. R. Dietz, General Manager -

Brunswick Steam Electric Plant RMP/mcg/LETCG1

(

Enclosure cc:

Mr. R. C. DeYoung

}

8302010267 830117

' OFFICIAI+ COPY PDR ADOCK 05000032 S

PDR IEAD