3AN 11 1983 Docket No. 70-2945 Union Electric Company ATTN:

Mr. Donald F. Schnell Vice President - Nuclear Post Office Box 149 - Mail Code 400 St. Louis, MO 63166 Gentlemen:

This refers to the routine safeguards inspection conducted by Mr. G. L. Pirtle of this office on December 16-17, 1982, of activities at Callaway Nuclear Plant, Unit 1, authorized by NRC Special Nuclear Material License No. SNM-1901 and to the discussion of our findings with Mr. S. E. Miltenberger and other memebers of your staf f at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and '-

terviews with personnel.

During this inspection, certain of your activities appeared to be in non-compliance with NRC requirements, as specified in the enclosed Appendix.

A written response is required.

Areas examined during this inspection concern a subject matter which is exempt from disclosure according to Section 73.21(c)(2), Part 73, Title 10, Code of Federal Regulations. This information must be handled and protected in accordance with the provisions of 10 CFR 73.21.

Consequently, the enclo-sure to this letter, our report of this inspection, and your response to the noncompliance identified in the enclosure to this letter will not be placed in the Public Document Room. Therefore, your statement of corrective action regarding the noncompliance identified in the enclosure should be submitted as a separate enclosure to your transmittal letter in the manner prescribed.

We understand that the commitments made in Paragraphs Sc, 8b and 9 of the report will be implemented regarding the matters described tharcir.-

7.f our understanding is incorrect, please notify us.

8301170100 830111 PDR ADOCK 07002945 PDR DMB:

Enclesure Contai,

ggoT S AFECUA3CS lhF0r..

Upon Separation In ;;

Page is DecontralicJ

Union Electric Company 2

ggg 1 y g))3 The responses directed by this letter (and the accompanying Notice) are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

We will gladly discuss any questions you have concerning this inspection.

Sincerely, Original Signed by1 R'. Millee J. R. Miller, Chief Technical Programs Branch

Enclosures:

1.

Appendix, Notice of Violation 2.

Inspection Report No. 70-2945/82-01(DETP)

(UNCLASSIFIED SAFEGUARDS INFORMATION) cc w/encls:

W. II. Weber, Manager Nuclear Construction S. E. Miltenberger, Plant Manager IE/DFFMS/SB NMSS File NMSS/SG cc w/encls, w/o UNCLASSIFIED SAFEGUARDS INFORMATION:

DMB/ Document Control Desk (RIDS) l Resident Inspector, RIII l

Region IV l

K. Drey Ronald Fluegge, Utility l

Division, Missouri Public Service Commission 7

RIII RIII RIII RIII j

P le/sv i

Wescott Mil $h i/6/83

& %)

llyly

  • (l!

(

3 l

1 t1 e Ln**ess e Carta.

L ij W E u.a..G S inF m U ca Separatio, i

IdSO IS Decontrallel l