N a

i U.S. NUCLEAR REGULATORY COMMISSION REGION III j

Report No. 70-2945/82-01(DETP) l Docket No. 70-2945 License No. SNM-1901 j

Licensee: Union Electric Company Post Office Box 149 - Mail Code 400 St. Louis, MO 63166 1

Facility Name: Callaway Nuclear Plant, Unit 1 Inspection At: Callaway Plant, Fulton, MO Inspection Conducted: December 16-17, 1982 Type of Inspection: Unannounced Physical Protection Inspector:

l. All I N 8b

/

i L. Pirtle Dated sical Protection Specialist I!IO!83 Approved By:

UJ.R. Creed, Chief Dated afeguards Section 2

Inspection Summary Inspection on December 16-17, 1982 (Report No. 70-2945/82-01(DETP))

Areas Inspected:

Included a review of the Interim Security Plan and Imple-menting Procedures; Security Organization; Access Controls; Physical Barriers;

+

Communications; Response; and Records and Reports. The inspection involved 13 inspector-hours by one NRC inspector. Two of the 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> were accomplished i

[

during off-shift periods. The inspection began during the day shift period.

i Results: The licensee was found to be in compliance with NRC requirements within the areas examined during this inspection except for the following item:

Access Controls: On one occassion, security related locking devices were not changed as required by the Interim Security Plan, i

i The licensee agreed to implement certain actions to strengthen their access i

control program and clarify an issue pertaining to response by local law

(

enforcement personnel.

(Details - UNCLASSIFIED SAFEGUARDS INFORMATION) i 8301170103 830111 E+nre Centoins P04tADOCK07002$k S5._;. " 3S INFORMATION p

Upon Separation This t

l Page is Decontrolled

.