November 16, 1982 DISTRIBUTION Docket-RMattson NRC'PDR RWHouston Docket tio. 50-219 Local PDR Glainas LS05-82-ll-050 ORB Reading FCongel NSIC WPasciak DCrutchfield TMo JLombardo Mr. P. B. Fiedler HSmith Vice President and Director - Oyster Creek OELD Oyster Creek Nuclear Generating Station ELJordan Post Office Box 333 JMTaylor Forked River, New Jersey 08731 ACRS (10)
SEPB
Dear Mr. Fiedler:
SUBJECT:
EVALUATION OF THE RADIOLOGICAL / ENVIRONMENTAL IMPACT OF GPU NUCLEAR'S PROPOSED PROJECT FOR DISPOSAL OF CONTAMINATED S0IL AT OYSTER CREEK FACILITY f
We have reviewed your letter and attachments dated October 27, 1982, in which you described plans to relocate approximately 17,000 cubic feet of contaminated soil. Pe understand that the soil is now located in a radiation control area and it will be elocated to another area on the site that is not a radiation controllea area. The relocated soil will be covered with a minimum of 6" of clean soil and possibly paved over with asphalt in the future.
' provides our detailed evaluation. Our calculations indicate that a person continuously occupying the central portion of the relocated soil will received a direct gamma radiation dose of approximately 60 mrem /
year which is about eight (8) times less than the 10 CFR Part 20 dose limit of 500 mrem / year for unrestricted areas. For a worker who spends about 2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> a year in this area the total body dose is reduced to 14 mrem / year.
If you pave this area with a minimum thickness of six (6) inches of asphalt the worker dose will be further reduced to less than 3 mrem / year. For a member of the public who infrequently visits the Oyster Creek facility and who spends much less time at this location than a worker, the total body dose will be proportionately lower.
We concur with your statement that the six inch layer of clean topping material will prevent further migration of the radioactive material via wind blown dust as the soil is presently uncovered.
o\\
59 gfp L
W o
8211220132 821116 DR ADOCK 05000219 9
p PDR omcr >
SURNAME )
oare >
nac ronu sia no-so3 nacu om OFFICIAL RECORD COPY esc. m isai-34.,co
i
- , I t'
fir. P. B. Fiedler November 16, 1982 enese estimated doses are negligibly small from the standpoint of occupational exposure limits and acceptably small from the standpoint of non-occupational exposure limits. They are close to or within the dose design objectives of 10 CFR Part 50, Appendix I for controlling radioactive effluents from light-water-cooled reactors, and are within nominal spatial and temporal variations in annual natural background exposure. We therefore concur with your plan to relocate this soil.
Sincerely, Original signed by/
Dennis M. Crutchfield, Chief Operating Reactors Branch #5 Division of Licensing
Attachment:
As stated cc w/ attachment:
See next page
.)RB#5
.D.L;0RB#5
,{N.b omce) suance > JLombar i.. D.C d.....
one>.11/.Il</8
..11ll$9182...
nac ronu ats 0o 803 nacu o24o OFFICIAL RECORD COPY usam iwi_mua
,l.
.~ ~.
u n-~~..
.w.
G Mr. P. B. Fiedler November 16, 1982 cc G. F. Trowbridge, Esquire Resident Inspector Shaw, Pittman, Potts and Trowbridge c/o U. S. NRC 1800 h Street, N. W.
Post Office Box 445
~
Washington, D. C.
20036 Forked River, New' Jersey 08731 J. B. Lieberman, Esquire Commissioner -
Berlack, Israels & Lieberman New Jersey Department of Energy 26 Broadway 101 Commerce Street New York, New York 10004 Newark, New Jersey 07102
~
Ronald C. Haynes, Regional Administrator Nuclear Regulatory Commission, Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 J. Knubel BWR Licensing Manager GPU Nuclear 100 Interplace Parkway Parsippany, New Jersey 07054 Depgt4, Attorney General State of New Jersey Department of Law and Public Safety 36 West State Street - CN 112 Trenton, New Jersey 08625 Mayor Lacey Township 818 Lacey Road Forked River, New Jersey 08731 i
U. S. Envircreental Protection.
Agency Region II Office ATTN:
Regional Radiation Representative 26 Federal Plaza New York, New York 10007 '
'~
Licensing Supervisor Oyster Creek Nuclear Generating Station Post Office Box 388 Forked River, New Jersey 08731
-m O
G n..
,