Addendum 2 to 820319 Deficiency Rept Re Inadequately Welded Studs on Embedded Strip Plates.Addendum Provides Info Re Shipment of Embeds (Type II Strip Plates & Crane Rail Plates) & Any Associated Problems
ML20027C193
Person / Time
Site: Harris  Duke Energy icon.png
Issue date: 10/05/1982
From: Parson R
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
CON-NRC-8 10CFR-050.55E, 10CFR-50.55E, 10CFR50.55E, NUDOCS 8210130567
Download: ML20027C193 (5)


Text

,.%1f CD&L Carolina Power & Light Company P. O. Box 101, New Hill, N. C.

27562 October 5, 1982 c:o 1,

Mr. James P. O'Reilly NRC-8

[

United States Nuclear Regulatory Commission a

d 'Z Region II O

~

101 Marietta Street, Northwest (Suite 3100) p Atlanta, Georgia 30303 m

2>

0 o m._

~

CAROLINA POWER & LIGHT COMPANY OO

~*

SHEARON HARRIS NUCLEAR POWER PLANT I7 1985 900,000 KW - UNITS 1 & 2

~;

DEFICIENCIES IN WELDED STUDS ON EMBEDDED STRIP PLATES ADDENDUM NO. 2 TO FINAL REPORT - ITEM 71

Dear Mr. O'Reilly:

Attached is Addendum No. 2 to the Final 10CFR50.55(e) Report issued to the NRC on March 19, 1982 for the above subject deficiency. This addendum shows all the shipments of embede (Type II strip plates and crane rail plates) and any associated problems. Please attach this addendum to the March 19, 1982 Final Report.

If you have any questions regarding this matter, please contact me.

Yours very truly, g w f Vv f-R. M. Parsons Project General Manager Shearon Harris Nuclear Power Plant RMP/sh

' Attachment cc:

Mr. G. Maxwell (NRC-SHNPP)

Mr. V. Stello (NRC)

[ OFFICIAL COPY 8210130567 821005 DRADOCK05000g W af 1

.j SHEARON HARRIS NUCLEAR POWER PLANT UNIT NO.' 1 DEFICIENCIES IN WELDED STUDS ON EMBEDDED STRIP PLATES ADDENDUM NO. 2 TO FINAL REPORT ISSUED MARCH 19, 1982 October 5, 1982' In a September 17, 1982 exit by Mr. Jack Harris of your office, Item 400 CDR 82-071 was discussed in reference to what information would be required to close.it.- Mr.

-Harris stated that he would need to know the shipment dates for each shipment and the inspection provided for each shipment.

Mr. A. M. Lucas, Senior Resident Engi-neer, informed Mr. Harrist that receipt-inspection was performed on all shipments of embed plates per site procedures. When problems are discovered, corrective action is taken. Per a follow-up call on September 21, 1982 between Mr.'A. M.-Lucas and Mr. Tom Conlan, attached is a listing of shipments of embeds received from Alfab, Inc. and any associated problems.

I i

a i

l

DATE OF NUMBER OF NUMBER OF PLATES /

PURCHASE ORDER SHIPMENT PLATES STUDS INSPECTED COMMENTS H-28931 11/3/80 193 32/50 Height and soundness for studs OK.

H-28931 11/18/80 385 50/50 Height and soundness for studs OK.

H-28931 11/20/80 384 50/50 RIR 80-221 was written as a result of one stud failing. The sample size was' increased to 150. No further problems resulted.

H-28931 11/24/30 30 8/13 Height and soundness for studs OK.

H-28931 11/25/80 408 50/50 Height and soundness for studs OK.

H-28931 12/1/80 393 50/50 Height and soundness for studs OK.

H-28931 12/10/80 377 50/50 Height and soundness for studs OK.

E-28931 12/18/80 444 50/50 Height and soundness for studs OK.

H-28931 12/29/80 535 80/80 Height and soundness for studs OK.

H-28931 1/5/81 418 50/50 Height and soundness for studs OK.

H-28931 1/7/81 380 50/50 Height and soundness for studs OK.

H-28931 1/9/81 408 50/50 Height and soundness for studs OK.

H-28931 1/9/81 375 50/50 Height and soundness for studs OK.

H-28931 1/16/81 432 50/50 Height and soundness for studs OK.

H-28931 1/21/81 33 8/13 Height and soundness for studs OK.

H-29961 12/29/80 250 32/50 Height'and soundness for studs.0K.

H-30402 12/3/80

-360 50/50 Height and soundness for studs OK.

H-30402 12/4/80 360 50/50 Height and soundness for studs OK.

H-30402 12/8/80 720 60/80 Height and soundness for studs OK.

5 DATE OF NUMBER OF NUMBER OF PLATES /

PURCHASE ORDER SHIPMENT PLATES STUDS INSPECTED COMMENTS H-30402 12/10/80 360 50/50 Height and soundness for studs OK.

H-30402 12/12/80 360 50/50 Height and soundness for studs OK.

H-30402 12/15/80 358 50/53 Height and soundness for studs OK.

H-30402 12/17/80 696 80/80 Height and soundness for studs OK.-

H-30402 12/18/80 727 80/50 Height and soundness for studs OK.

H-30402 12/23/80 959 80/80 Height and soundness for studs OK.

H-30402 12/29/80 738 80/8G Height and soundness for studs OK.

H-30715 2/24/81 107 20/20 RIR-81-34 written as a result of illegible data. Height and soundness for studs OK.

H-36504 1/18/82 443 50/400 One (1) plate was found to have one defective stud. This nonconformance was noted on DDR-806.

This was deemed reportable.

H-36504 1/20/82 506 80/200 Height and soundness for studs OK.

H-36504 1/27/82 526 100%

54 plates were found to have defective studs.

DDR-812 was written.

This was deemed reportable.

H-36504 1/27/82 475 100%

Five (5) plates were found to have defective studs. DDR-812 was written.

This was deemed reportable.

H-36504 2/22/82 353 50/50 Height and soundness for studs OK.

H-36504 2/25/82 470 80/200 Eight (8) plates were found to have defects.

Six (6) plates had arc strikes resulting from weld repairs, one elate.had-one (1) stud' lacking 360* flash plus had a crack (Cont'd. next page)

-DATE GF NUMBER OF NUMBER OF PLATES /

PURCHASE ORDER SHIPMENT PLATES STUDS INSPECTED COMMENTS H-36504 (cont'd.)

at the base; it failed when bent to 30*.

One (1) stud on another plate was bent in the area of a repair weld revealing cracking.- DDR-840 was written. As a result of the failing stud, this was deemed reportable.

E-36504 3/18/82 60 100%

Three (3) plates were each found to have one (1) defectiva stud. This nonconformance was noted on DDR-862.

This was deemed reportable.

H-37507*

4/16/82 43 100%

Studs and welds on cadweld sleeve Os.

H-37507*

4/29/82 75 100%

Studs and welds on cadweld sleeve OK.

H-37507*

5/10/82 81 100%

Studs and welds on cadweld sleeve OK.

H-37507*

6/11/82 77 100%

Studs and welds on cadweld' sleeve OK.

RIR 82-144 was written as a result of covers for cadweld sleeves being both damaged and missing.

  • Crane Rail Plates