ML20024D521
| ML20024D521 | |
| Person / Time | |
|---|---|
| Site: | Hatch |
| Issue date: | 08/01/1983 |
| From: | Gucwa L GEORGIA POWER CO. |
| To: | Stolz J Office of Nuclear Reactor Regulation |
| References | |
| RTR-NUREG-0737, RTR-NUREG-737, TASK-2.D.1, TASK-TM NED-83-409, TAC-44586, TAC-44587, NUDOCS 8308050177 | |
| Download: ML20024D521 (1) | |
Text
Georg.a Power Company 333 Pedmont Avenue Atlanta, Georg a 30308 Telecnone 404 526 6526 Mairg Address-Post off ce Box 4545 A:tanta. Georg a 30302 Georgia Power L T. Gucwa IN: soutten elec:rc system Chief Nuclear En7neer Power Generai.on Department ED-83-409 August 1, 1983 Director of Nuclear Reactor Regulation Attention: Mr. John F. Stolz, Chief Operating Reactors Branch No. 4 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.
20555 NRC DOCKETS 50-321, 50-366 OPERATING LICENSES DPR-57, NPF-5 EDWIN I. HATCH NUCLEAR PLANT UNITS 1, 2 NUREG-0737 ITEM II.D.1 SAFETY RELIEF VALVE (SRV) TESTING Gentlemen:
Your letter dated December 29, 1982 requested Georgia Power Company to respond to six questions related to the BWR Owners Group SRV test program.
Our initial response dated April 4, 1983 stated that a supplemental report providing results of a dead weight analysis of Plant Hatch SRV discharge lines would be sent to you by July 29, 1983.
Subsequently, our architect-engineer has informed us that due to the differences in the piping geometry and boundary conditions, no one line can be identified as typical.
Therefore, it is concluded that unique analyses would have to be performed on all SRV discharge lines. This analysis is underway and anticipated to be completed by the end of 1983.
Consequently, we are revising our proposed submittal date to February 17, 1984.
If this revised date is unacceptable or if you have additional questions in this regard, please contact this office.
Very truly yours, f( C+s L. T. Gucwa CT/mb xc:
J. T. Beckham, Jr.
0l 0
H. C. Nix, Jr.
J. P. O'Reilly (NRC-Region II)
Senior Resident Inspector 830B050177 830801 PDR ADOCK 05000321 P