r 3 ConSumBIS L Power a o sew s\\
(QQ QQ Chairman of the Board and President General offices: 212 West Michigan Avenue, Jackson, Mich8gan 44201 e (517) 7881600 April 14, 1983 Mr James R Tourcellotte, Chairman Regulatory Reform Task Force US Nuclear Regulatory Commission Washington, DC 20555 Attached is information you requested In your letter of February 8, 1983.
This information regarding the cost to Consumers Power Company for backfitting the Palisades Plant (Docket 50-255) has been tabulated as you requested. There are three tables: Category 1 - Imposed by NRC Regulations / Orders; Category 2 - Imposed by NRC Bulletins and Post - TMI requirements as defined in NUREG-0737; and Category 3, those initiated by Consumers Power Company for the continued safe operation of our plant.
Please notify us if you need further information.
s/e
/
1 1,
8307080321 830622 PDR REVGP NRCREGPDR OC040483-NL01
Backfitting Cost Experience For Consumers Power Company's Palisades Plant Palisades Plant - 1 Unit The Palisades Plant is a first generation Combustion - Engineering pressurized water reactor with a thermal rating of 2530 MW and an electrical rating of 810 MW.
The construction permit was received in March, 1967, the provisional operating license in March 1971 and the first generation of electricity occured December 31, 1971.
The total cost was $149,046,000.
Cooling towers for closed cycle cooling and a rad-waste building'for zero rad-waste effluent were mandated by a settlement agreement with an intervener group.
These added $42,559,000 to the construction cost of the Palisades Plant. Using the above costs, the cost per kilowatt in 1971-72 would be $238/KWe.
Using the State of Michigan Bureau of Labor Statistics, inflation factors etc of 2.6, the 1982 value of an equivalent plant of this 810 Mwe size would be $618/KWe excluding any backfitting costs.
MIO40483A-NL01
PALISADES PLANT CATEGORY (1)
IMPOSED BY NRC (RULE OR ORDER)
I Electrical Equipment Qualification
$ 20,800,000 Security Upgrades 5,430,000 Fire Protection Mods 6,000,000 s
Total
$ 32,230,000 sep e
9 9
S 4
e O
9 6
4 MIO40483A-NL01
PALISADES PLANT CATEGORY (2)
IMPOSED BY NRC - POST TMI & OTHER BULLETINS PCS Hi-Point Vents
$ 1,500,000 Shielding Evaluation & Mods 3,100,000 Control Room Vent System Upgrade 28,800,000 Containment Isolation Upgrades 4,500,000 AFW System Upgrade 21,900,000 Inadequate Core Cooling Instrument 6,900,000 l
Auxiliary Building Addition 10,200,000 Electrical System Expansion 2,400,000 Critical Function Monitor System 7,000,000 Effluent Radiation Assessment System 9,600,000 Anchor Bolt Inspection & Mods 25,700,000 Struct. Eval. & Upgrade Block Walls 3,400,000 High Energy Line Break Mods 2,700,000 S-G Wide Range Level Indication 1,110,000 Long-Term Cooling Mods 6,720,000 Total
$135,530,000 4
9 MIO40483A-NL01
PALISADES PLANT CATEGORY (3)
INITIATED BY CONSUMERS POWER COMPANY S-G Replacement (Costs to date)
$ 22,700,000 Station Battery (Upgrade) 1,500,000 Spent Fuel Storage Racks 5,000,000 Parking Lot Expansion 850,000 Warehouse 3,700,000 Plant Support Building 3,100,000 Turbine Rotor (Upgrade) 9,050,000 hadwaste Solidification System 15,500,000 Moisture-Separater Reheater (Upgrade) 1,800,000 Main Condenser Tube Replacement (Upgrade) 1,700,000 Feedwater Purity System 12,600,000 Boric Acid-Heat Tracing', System 2,400,000 Dilution Water Mods 1,200,000 HPSI Pump Mods 500,000 Fuel Analyses For Increase Power 1,100,000 S-G Sleeving Repair Equipment 2,000,000 Miscellaneous 10,260,000 Total S 94,960,000 S