._

.i v.... -a

,.n' g

~

.ADMI'NISTRATIVE C a.ROLS lt>

PROCEDURES AND PROGRAMS (Continued) c.

The change is documented,-reviewed in accordance with Specification

-6.7.2 and approved by the General Manager-Nuclear Plant or department t

head of the responsible department within 14 days of. implementation,

.b 6.7.4 The following programs shall be established, implemented, and maintained:

f a.

Primary Coolant Sources Outside Containment

I.

A program _to reduce-leakage from those portions of-systems outside containment that could contain highly radioactive fluids during a.

serious transient or accident to as low as practical levels.

The

(

systems include.the following:

1)

Residual Heat Removal System l

2)

Containment Spray System (excluding NaOH Subsystem) 3)

Safety Injection (excluding Boron Injection & Accumulators) 4)

Chemical and Volume Control System (Letdown, ":r;r "::y;':,

j; l_

and Charging Pumps) l~

5)

Post Accident Processing System 6)

Gaseous Waste Processing System l

7)

Nuclear Sampling System (Pressurizer steam and liquid sample L

lines, Reactor Coolant sample lines, RHR sample lines, CVCS Demineralizer and Letdown Heat' Exchanger sample lines only)

The program shall include the following:

r

1) _

Preventive maintenance and periodic visual inspection requirements, and 2)

Leak test requirements for each system at refueling cycle intervals or less, b.

.In-Plant Radiation Monitorino A program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident i --

conditions.

This program shall include the following:

1)

Training of personnel, 2)

Procedures for monitoring, and.

[

l(

3)

Provisions for maintenance of sampling and analysis equipment, c.

Secondary Water Chemistry A program for monitoring of secondary water chemistry to inhibit steam generator tube degradation.

This program shall include:

9003120406 900301 PDR ADOCK 0D000424 P

PDR V0GTLE UNITS - 1 & 2 6-15

_ __