4 ADMINISTRATIVE CONTROLS e.

Records of gaseous and liquid radioactive material released to the environs.

f.

Records of transient or operational cycles for those facility-components identified in Table 5.7.-l.

g.

Records of training and qualification for current members of the plant'

staff, h.

Records of inservice inspections performed pursuant to these Technical Specifications..

i. Records of Quality Assurance activities required by the QA Manual.
j. Records of reviews performed for changes made to procedures or equipment or reviews of tests and experiments pursuant to 10 CFR 50.59.

k.

Records of meetings of the PRC and NGRC.

1.

Records for Environmental Qualification which are covered under the provisions of paragraph 6.13.

y Records of analytical results required by the Operational Radiological m.

Environmental Monitoring Program.

6.11 RADIATION PROTECTION PROGRAM Procedures for personnel radiation protection shall be prepared consistent-with the requirements of 10 CFR Part 20 and shall be approved, maintained and adhered-to for all operations involving personnel radiation exposure.

6.12 HIGH RADT.ATION AREA R

6.12.1 In lieu of the " control device" or " alarm signal" required by paragraph l

20.203(c) (2) of 10 CFR 20 a High Radiation Area in which the intensity of radiation is greater than 100 mrem /hr but less than 1000 mrem /hr I

shall be barricaded and conspicuously posted as a High Radiation Area and entrance thereto shall be controlled by issuance of a Radiation Work Permit and any individual or group of individuals permitted to enter such areas shall be provided with one or more of the following:

a.) A radiation monitoring device which continuously indicates the radiation dose rate in the area, or b.) An integrating alarming dosimeter which alarms when a preset integrated dose or dose rate is received.

Entry into such areas with this alarming dosimeter may be made after the dose rate levels in the area have been established and personnel have been made knowledgeable of them, or q

8912280094 891221 PDR ADOCK 05000302 P

PDC CRYSTAL RIVER - UNIT 3 6-19

ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA (Continued) c.) An individual trained in Health Physics Procedures with a radiation dose rate monitoring device, who is responsible for providing positive control over the activities in the area and who performs periodic radiation surveillance at the frequency specified by the Radiation Work permit.

6.12.2 A High Radiation Area in which the intensity of radiation is greater than 1000 mrem /hr shall be subject to the provisions of 6.12.1 above, and in addition locked doors shall be provided to prevent unauthorized L

entry into such area.

The keys shall' be maintained.under the administrative control of the Health Physics Supervisor with one key assigned to the administrative control of Shift Supervisor on duty.

Individual areas that are accessible to personnel, with radiation levels such that a major portion of the body could receive in one hour a dose in excess of 1000 mrem,** and that are located within large areas such as the Reactor - Building where no enclosure exists for purposes of locking and no enclosure can be reasonably constructed around the individual area, shall be roped off and conspicuously posted, and a flashing light shall be activated as a warning device.

6.13 ENVIRONMENTAL OVALIFICATION i

6.13.1 By no later than June 30, 1982, all safety-related electrical equipment in the facility shall be qualified in accordance with the provisions of Division of Operating Reactors

" Guidelines - for Evaluating Environmental Qualification of Class lE. Electrical Equipment in i

Operating Reactors" (DOR Guidelines) or NUREG-0588 " Interim Staff i

Position on Environmental Qualification of Safety-Related Electrical Equipment," December, 1979.

Copies of these documents are-attached to Order for Modification of License DPR-72 dated October 24, 1980.

6.13.2 By no later than December 1,1980, complete and auditable records must be available and maintained at a central location which describe the environmental qualification method used for all safety-related electrical equipment in sufficient detail to document-the degree of l

compliance with the D0R Guidelines or NUREG-0588.

Thereafter, such i

records should be updated and maintained current as equipment is replaced, further tested, or otherwise further qualified.

    • Measurement made at 18" from source of radioactivity, 1

CRYSTAL RIVER - UNIT 3 6-20 l

1