Forwards Review of RCS Pressure Boundary Info to Determine Conformance to Guidelines of NUREG-0313,Revision 1, Technical Rept on Matl Selection & Processing Guidelines for BWR Coolant Pressure Boundary Piping
ML20009G900
Person / Time
Site: FitzPatrick 
Issue date: 07/31/1981
From: Bayne J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Ippolito T
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0313, RTR-NUREG-313, TASK-A-42, TASK-OR GL-81-03, GL-81-3, GL-81-4, JPN-81-54, NUDOCS 8108050208
Download: ML20009G900 (6)


Text

__ _

e

-O POWER AUTHORITY OF THE STATE OF NEW YORK 10 CoLUMeus CincLE NEW YORK. N. Y. I0019 (212) 397 62Co G EO R,G,E T. m E n n y Ope n 4 71NG OFFICER TRUS TE ES JOHN W. BOSTON JOHrd S.OfSON EDIOENT ACCEDURES

  • "'"'*""'"C" GEORGE L. eNG ALLS JOSEPH R. SCHMIEDER vsC E CnalamaN nas DENT Cris p RICH ARD M FLYNN ROeE N T t. MILLON21 LEROY W. SINCLA r a E D Enic x n. C'^""

Jely 31, 1981

,,,C.

JPN-81-54 twCMASa rREY l'".' "lai;"'.* A'"'

W o

Y*

Director of Nuclear Reactor Regulation (4

hk.

l q,

g g 4Wy United States Nuclear Regulatory Commission IT Washington D.C.

20555 (9'

usM

$s.

/

Attention Mr Thomas A.

Ippolito, Chief g

Operating Reactors Branch No.2 Division of Licensing N y'/

P 4

W Subject James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 Implementation of NUREG-0313, Revision 1. July 1981 (Generic Letter 81-04)

Reference:

NRC Letter, D.G.

Eisenhut to All BWR Licensees (Except Humboldt Bay and Lacrosse), Generic Letter 81-04 dated February 26, 1981 Dear Sirs; The Authority has completed it's review of the Reactor Coolant System pressure boundary materie.19 to determine the extent of conformance to the guidelines of NUREG-0313, Revision 1,

" Technical Report on Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping" dated July 1981.

The attachment to this letter summarizes the results of this review and responds to the reference letter.

As requested, ASME Code Class 1 and 2 pressure boundary piping, safe ends, and fitting material, including weld metal, were reviewed to determine if they eneet the matarial selection, testing and processing guidelines of NUREG-0313, Revision 1.

Those Reactor Coolant System pressure boundary materials not conforming to this criteria have been identified and the affected systems classified as service or nonservice sensitive.

PDR ADOCK 05000533 005 8108050208 810731 1

P PDR

(

. Proposed changes to the James A.

FitzPatrick Technical Specifications to incorporate the augmented inservice inspection program required by NUREG-0313 Revision O were submitted January 6, 1978.

These proposed changes will be revised in accordance with the model technical specifications and NUREG-0313 Revision 1 by August 15, 1981.

Very truly yours, j

b.

ef Senior Vice President Nuclear G^neration i

ATTACHMENT Power Authority of the State of New York James A.

FitzPatrick Nuclear Power Plant Implementation of NUREG-0313, Revision 1 (Response to Generic Letter 81-04)

Generic Letter No. 81-04 dated February 26, 1981 requested a review of the materials in the Reactor Coolant System pressure boundary to determine conformance to the material selection, testing and processing guidelines set foeth in NUREG-0313, Revision 1,

" Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping".

The nonconforming materials in the Reactor Coolant System pressure boundary have been indentified and the affected components classified as service or nonservice sensitive.

The majority of the material used in the Reactor Coolant System pressure boundary is Type 304 austentic stainless steel, which has a carbon content of greater than 0.035 percent and has been classified as nonconforming material based on NUREG-0313, Revision 1.

Type 316 stainless steel is present only in a portion of the recirculation discharge valve bypass line.

This material is also classified as nonconforming based on NUREG-0313, Revision 1.

F,ased on the Authority's revicw of Reactor Coolant System pressure boundary materials, action with respect to nonconforming, service and nonservice sensitive materials will be as follows:

1.

Recirculation Piping The 22 and 28-inch recirculation piping and weld material has been classified as nonconforming and nonservice sensitive.

An augmented inservice inspection program has been implementea in accordance with NUREG-031J, Revision O, and will be modified in accordance with the requircaer,ts of Revision 1.

The 12-inch recirculation ris6r piping is nonconforming; however, we do not consider it to be service sensitive.

This classification is based on the lack of evidence of intergranular stress corrosion cracking (IGSCC) occuring in recirculation risers in domestic BWRs.

Further, the James A. FitzPatrick Inservice Inspection Program included the inspection of welds to this piping during the last three outages.

No evidence of IGSCC was found.

In view of the concarns stated in NUREG-0313, Revision 1, an augmented inspection will be implemented as described in NUREG-0313, Revision 1, but on an initial 40-month schedule.

This schedule will provide sufficiently frequent inspections to discern IGSCC prior to failure, and will minimize occupational radiation exposure to inspection personnel.

- 1 of 4 -

k

The replacement of these recirculation risers will be considered if evidence of IGSCC is found.

The use of Induction Heating Stress Improvement on all or part of l

the recirculation system, including the risers is, however, under consideration.

Nonconforming safe-ends will be inspected in accordance with the requirements of NUREG-0313, Revision 1.

The 4-inch recirculation discharge bypass loops are classified as nonconforming and service sensitive.

An augmented inservice inspection program has been implemented as described in NUREG-0313, Revision O and will be modified in accordance with the requirements of Revision 1.

Consideration will be given to the replacement of these bypass loops if evidence of IGSCC is found.

2.

Core Spray Piping i

The two core spray piping segments, between the reactor vessel and the first valve, have been classified as nonconforming and service sensitive.

The remaining portions of the core spray system are constructed of carbon steel.

An augmented inservice inspection program will be implemented as described in NUREG-0313, Revision O and has beer modified in accordance with the requirements of Revision 1.

Inspections of this piping have been performed during the past three outages.

Consideration will be given to the replacement of this piping with conforming material if evidence of IGSCC is found.

3.

Control Rod Drive Hydraulic Return Piping Control rod drive hydraulic return piping between the vessel nozzle and the first manual valve has been classified as nonconforming and service sensitive.

All other control rod drive hydraulic return piping within the Reactor Coolant System pressure boundary is constructed of carbon steel.

An augmented inservice inspection program as described I

in NUREG-0313, Revision O has been implemented and will continue until this piping is re-routed in accordance with the criteria of NUREG-0619, "BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking."

Inspections of this piping have been performed during the past three outages.

It la anticipated that this l

modification will be completed during the 1983 refueling outage.

4.

Residual Heat Removal and Reactor Water Cleanup Piping i

l Four segments of the Residual Heat Removal and Reactor

- 2 of 4 -

- ~..

4 4

Water Cleanup piping are constructed of nonconforming material.

These nonconforming segments are between:

a.

Recirculation piping and manual isolation valve RHR-81A; b.

Recirculation piping and manual isolation valve RHR-81B; c.

Recirculation piping and manual isolation valve RHR-88; and d.

RHR piping and. manual isolation valve RWC-46.-

i These piping segments have shown no' evidence of stress cortasion.

Based upon this, the Authority has classified these piping segments as nonservice sensitive.

An augmented inservice inspection program has been implemented as described in NUREG-0313, Revision 0 and will be modified in accordance with the requirements of Revision 1.

Inspections of this piping have been performed during the past three outages.

5.

Reactor Coolant Boundary Vent, Drain and Instrument Piping Vent, drain and instrument lines which form part of Reactor Coolant Boundary that are 1-inch'or less in' diameter have been classified as nonconforming and nonservice sensitive.

These lines are currently exempt from inspection under the FitzPatrick Plant Technical Specifications which are based on Section XI'-of the ASME Boiler and Pressure Vessel-Code, 1970 Edition.

The revised James As FitzPatrick Inservice Inspection Program, which is based cn1 the 1974' Edition of Section i

XI thrcugh the Summer 1975 addenda of the ASME Code and '

~

is currently under review by the Commission, also exempts these lines from volumetric examination.

These j

lines will be visually inspected in accardance with' code requirements.-

1 Nuclear Boiler Instrument lines (1/2 to 1-inch)', and the Standby Liquid Control line '(1 1/2-inch) to the reactor vessel from manual valve SLC-18-to check valve SLC-16, have been classified as nonconformins and i

nonservice sensitive. 'These lines are-currently exempt i

from inspection under the FitzPatrick Plant Technical Specifications which are based on the 1970 Edition of Section XI of the ASME Code.

The revised inservice inspection program-is' based on the 1974 Edition of-

]

Section XI of the ASME Code through the Summer 1975 addenda which allows'for.the exemption'of these lines from volunetric' examination. ~These lines will be i

visually examined in accordance with code; requirements, i

3'of 4 -

m

_.. ~

1 There are no plans for replacement of any of these vent, drain and instrument lines nor for the Standby Liquid Control System lines.

Since the issuance of NUREG-0313. Revision 0, and the initial submittal of proposed changes to Technical Specifications on January 6,'1978, the Authority has been performing an augmented inspection program based on our response to Revision 0 of NUREG-0313.

r

- Nonconforming, service sensitive piping has been inspected every refueling outage, and no indications of IGSCC have been discovered.-

Therefore, these inspections will be. performed on a 36-month schedule as described in NUREG-0313, Revision 1.

Leakage from these i

lines is already monitored by an integrated leak rate detection system as described in the PSAR.