05000327/LER-1981-075-03, /03L-0:on 810623,found Sufficient Clearance Did Not Exist Between Alternate Charging Line from Regenerative Heat Exchanger to Reactor Coolant Loop 4.Caused by Inadequate Original Drawings

From kanterella
(Redirected from ML20009F553)
Jump to navigation Jump to search
/03L-0:on 810623,found Sufficient Clearance Did Not Exist Between Alternate Charging Line from Regenerative Heat Exchanger to Reactor Coolant Loop 4.Caused by Inadequate Original Drawings
ML20009F553
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 07/21/1981
From: Harding M, Kirk G
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20009F551 List:
References
LER-81-075-03L, LER-81-75-3L, NUDOCS 8107310296
Download: ML20009F553 (2)


LER-1981-075, /03L-0:on 810623,found Sufficient Clearance Did Not Exist Between Alternate Charging Line from Regenerative Heat Exchanger to Reactor Coolant Loop 4.Caused by Inadequate Original Drawings
Event date:
Report date:
3271981075R03 - NRC Website

text

_

LICENSEE EVliNT REPORT CONTnCL ULCCK: l l

lh (Pt.ECOE PnlM? On TYPE ALL nEQUtnEO INFOCMATION) 0

~.irl I r l 41 s ! i l p i t !@lo lo I I o f ol o f o l 01 1 o 10 l@l 4 11111111 l@l I

l@

ee Lu.s o'.t k CutJL I4 IS L6CLNGENuvutH 2S 26 LICENSE T vrt 40 57 Ca r.

t u >= 2 ' r olil

';l,'C Ir.!@loI3tololo1312 l7 gjofet2131aIt @l0;712111811Jg 4
  • nJ 68 goc a t r NUvsippe 68 63 Evf NT OArt 74 73 AgpCAT D ATE 80 cvrNT CE3Cn8PTICN ANO rnOO AOLc CONSECUENCE: h EE l_flait 1 in Mode 4 with'RCS temperature and pressure at 310 F and 700 PSIG.

It was o!J) I discovered that sufficient clearance did not exist between alternate chargina line'from]

'oj i i the recenerative heat exchanaer'to reactor coolant loco 4 and obstructions.,at the con-l

~

!oj>l l crete pressurizer base. This condition could result in thermal expansion overstressingI o is I l a pine suoport oossibly causing the alternate charging line to break. There was no l

10 i / I I rr e men oubl ic health or safetv.

Previous Occurrences - None.

]

o 9 i.i l l l

80 7

8 9 S v 5 f E Nt

CAUSE

CAUSE Coup VA(vf CCCE COOF

$USCCDE COM*CNE NT COCE

$U8CCCE sV8 CODE

oiol l P I C l@ l Bl@ l A lh l Pl Il Pl E l X l X l@ l A l@ 'l Z l @

9 10 11 12 13 18 19 23

$E OVE N TI AL OCtunAENCE REPCAT R EVt31oN

( qino EVENTYEAR REPCnT No.

400E TYPE No.

@ "a(E >o a '

Ielil 1-1 l 017 i s I 1/l 10i3I l Ll l-l 101 it n

n n

20 2

n n

u 2

Cov8CNFNT A C T ' C *f SUTUH(

(S8ECT SMUTOCwN AT'T ACMutNT N7nO 4

'ntVE cCup.

uaNUsACTUAEA T AKC'J ACTICt4 oNFLANT utTMCU HOUA$

SU8v'TfEO Fonu3US.

suretic A l F !@l Z l@

l Z [@

[Zj@

l 0 l0 l0 l l

l Yl@

lNl@

lL l@

lX l9 19 19 l JJ J4 3S J6 37 40 41 47 43 44 47 caust oE.crueTicN Ano conntcTivE ACTIONS h

["I I--] l. or l e i na l drawings did not indicate the reautred clearance for the alternate chargine

)

!i I I line in the area of the pressurizer base.

Obstructions and interferences were removed i [gl and the hanger was relocated on the alternate charging line on 6-24-81.

'ililI D *Il L 9 80 r a. u s e v 7

ME THC0 C'8

r A t.
  • t. P C W E R OTHEnSTATUS CISC Ov n n y DISCQvEnv oEsCRIPTioN

' i' ! (_Clh l 0 l 010 l@l NA l

lCl@l Piping Inspection j

M r ej s t y Co trut m e i A.e e, or.e r t.1 e r AuCuN T OF AC TIVITY (CCATION CF AELEASE N^

l I

N^

l m,, L., W l x ! @ l

,n so er H. ion r L r e ro.i m t,;

'M l0l0lo!hlZ lh ;CntPTICN -

I Nie qr o Tvrt OE NA G

'J lt i;

I3 80 P[n0044((sqjygn(;

M s.* n ( 4 CEtCnieTICH NA

.,__,l g (oInlolhl ti 12 80 3 '

1 O',*. n r 051 c a u ^ f,C f O F ACI LI TY Y V' I DE00fH8f D

.-, I z 'fG(

NA l

l 19 l

'O

' "' t 'ci r v 8107310296 810721 NRC USE crn,

i..ur, of:Cnie 'ON PDR ADOCK 05000327 OljlMiCl NA S

PDR l

l!l!!III!I!II 0

'l to 68 89 N;une af Preparcr: Glenn B. Kirk / Mike R.'

Harding Phone: (615) 842-8317 i

J

Tennsgres valicy nutnority Sequoyah Nuclear Plant LER SUPPLDENTAL INFORMATION SORO-50-327/81075 Technical Specification Involved:

3.4.10 Report eil Under Technical Specification:

6. 9.1.13.b iLite ol Ocentrence: 6/23/81 Time of Occurrence:

0800 CDT Identification and Description of Occurrence:

During a Unit 2 piping inspection. a piping interference was discovered.

Upon inspection of similar piping on Unit 1 it was discovered that the alternate charging line from the regenerative heat exchanger to reactor coolant loop #4 did not have sufficient clearance with obstructions in the area of the concrete pressurizer base.

Conditions Prior to Occurrence:

Unit 1 in Mode 4 with RCS temperature and pressure at 310 F and 700 PSIG.

Apparent Cause of Occurrence _:

w.

Original drawings did not indicate the required clearance for the alternate charging line in the area of the pressurizer base.

Analysis of Occurrence:

With no clearance in this area, thermal expansion of the pipe could result in overloading of a pipe support on the alternate charging line and over-loading the alternate charging line to RCS. loop 4 connection.

Corrective Action

Obstructions and interferences were removed and the hanger was relocated on the al ternate ~ charging line. This work was completed on 6-24-81.

Failure Data:

None