Forwards Request for Info Re Equipment Qualification for Seismic & Hydrodynamic Loads.Info Requested by 810713 to Meet Scheduled 810727 Site Visit
ML20009B437
Person / Time
Site: Fermi 
Issue date: 07/07/1981
From: Tedesco R
Office of Nuclear Reactor Regulation
To: Tauber H
DETROIT EDISON CO.
References
NUDOCS 8107150444
Download: ML20009B437 (3)


Text

-

9 w.,.

~r$m g,

[

y.

p.

y 4

DISTRIBUTION:,

hk JUL 7 1981 d

DEisenhut PDR JYoungblood LPDR DocketNo.:liSOM157 MRushbrook NSIC

-. r.,,-. m.. ' " " '

LKintner TIC SHanauer AC li6

'~

Mr. Harry Tauber RVollmer y

Jg Vice President TMurley eg

_,m,,,,,

' Engineering & Construction " [ [ [

rt eld'M$

pjb

\\

Detroit Edison Company

.,_,,,'.'.'. 0EtD 9

2000 Second Avenue O

Detroit, Michigan 48226

',, ',', (' [., [ 1,',[,'

E,})

i

/'

Dear Mr. Tauber:

A +-

J g

....-,,s..-

Sub.iect:

Request for Infordtion._Concerning,Equjpment Qualiff. cati Seismic and Hydrodynamic Loads, for Fermi. 2 Our letter dated March 20, 1981 provided. forms.to. be, completed for_ our review of equipment qualification for, seismic. and hydrodynamic loa'ds '(Request 414 6)..

Please provide the information listed, jn the forms;for each,of,,the,25, i.tems.,

listed in the enclosure to this let,ter,._,

In order to meet the scheduled site, yisit during.the week of. July.27,198.1, we request that you provide thjs information by, July,13,.1981.,.

Since we are conducting these reviews wit,h the, assistance of the national labs, we request that one copy of. the. requ.est.ed, information be. sent directly.

to:

Dr. Morris Reich..

Department of.. Nuclear. Energy,..

Building 129 Brookhaven National Laboratory,,

Upton, New York 11973

~

If we are to meet the above schedule 1t is e.ssential that the labs receiv,e..

your submittals at the same time, as. the,NRC, staff.,

~

Sincerely,

~

original signed by Robert L. Tode*N Robert L. Tedesco, Assistant Director..

for Licensing Division of Licensing s.

Enclosure:

'..m,-,..

~

Request for Additional

..,m Information

.,_,,m,,

/).

.... cc,,,,,,See, e t, pa ge,,,,,,,, p,L,:L B,

,,D(;

, QLj$f L,,,,,,

"" nl07:50444 810707 v

' "*nt

.g.....BJ o load..RLTpd.es.co...

PDR ADOCK 05000341-

/81 7/ /81 7/ (pf 81

,A PDR ye row sie no.coinacu o24o OFFICIAL RECORD COPY

  • *o 'Sw329 2.

. q:.. y t-

'Mr. Harry Tauber-Vice President Engineering & Construction Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226-cc:

Eugene B. Thomas, Jr., Esq.

David ~ E. Howell,- Esq.

LeBoeuf, Lamb. Leiby & MacRae 21916 John R 1333 New Hampshire Avenue, N. W.

Hazel Park,. Michigan

-48030 Washington, D. C.

20036 Mr. Bruce Little-Peter _A. Marquardt, Esq.

U. S. Nuclear Regulatory Commission Co-Counsel Resident Inspector's Office Th'e Detroit Edison Company 6450 W. Dixie Highway 2000_Second Avenue Newport, Michigan 48166 Detroit, Michigan 48226 Dr.- Wayne Jens-Mr. William J. Fahrner Detroit Edison Company Project) tanager.- Fermi 2 2000 Second Avenue The Detroit Edison Company Detroit, Michigan 48226 2000 Second Avenue Detroit, Michigan 48226 Mr. Larry E. Schuerman Detroit Edison Company-3331 West Big Beaver Road Troy, Michigan 48084 s

+

,.,3

=

M _ q2.;c -

'Y.

J. -

FERMI:2

. Equipment List for SQRT Site Audit.

. (Scheduled on the week of 7/27/81).

jfB001 Equipment Bldg./Elev.

iMechanical

'1..

ChilledWaterPumps-(T41-00-C-041-FA-001):

Aux. Bldg.,-677'-6"

.- 2.. 10"TypeL4340. Damper l(T41-00-F-900-)

Aux. Bldg., Varies 3.

Engine; Instrument Panel (R30-00-S-900-BA-003)RHR Complex, 590'-0" 4.

l Diesel Generator Service Water Pumps F

L(R30-00-S-900-RA-005)

RHR Complex, 590'-0"

.5..

RHR Mech. Draft Cooling' Towers

-(E11-56-B-900-BA-003)

RHR Complex l617'-0" -

.. 6.

124" 300# Globe Valve Fig. #3051 WE SMB-4-200' Motor Oper.(A-31-00-F-900-RA-029Peactor Bldgc,; Varies

-7.

-4" 600# Y-Globe Valve, Fig. 16051-Y,WE, Limit h

SMB-0-40'M0 (A31-00-F-900-RA-042)

Reactor B1dg., Varies b

l 8.~

'18"'Watersphere Valve with Betto's Robotarm Actuator (A31-00-F-900-RA-153)

Reactor Bldg.

'9.

Swing Check Valves.20", V12-2001, 2002, 2003, 2004,(A31-01-F-900-RA-001)

,593

10. EECW Pumps B11-93M (P44-00-C-001A-RA-001 Reactor Bldg., 613'-6" I&C
11. Floor Mounted Instrument Racks Reactor Bldg., 684'-6" L(H21-01-P-501B-RA-001)
12. Remote Shutdown Panel C35-P001 Reactor Bldg., 613'-6"

-Electrical 13.

480 V SWGR Volt Reg.-1500 KVA (R14-00-S j

900-QL-031)

~ Auxiliary Building

,14 ~ Battery Racks for 130V DC battery (R32.

S-900-RA-003)

Aux. Bldg., 643'-6"

15. Nuclear Penetration Canister Assembly (T23-01-X-900-BA-008)

JNSSS-Equipment Hechnical 16.

In-Core Guide Tube, TOP (B11-D199)

Reactor Bldg., 632'-5"

.17.

Reactor Vessel Stabilizer (B11-0-002)

Reactor Bldg., 645'-5"

~18.

Isolation Valve (B21-F-028)

Reactor Bldg., 589'-5"

'19.

Recirc. Discharge Valve (B31-F031)

Reactor Bldg., 578'-10"

20. Hydraulic Control Unit (C11-D001)

Reactor Bldg., 583'-6" Electrical -

.21.

Barton Flow XMTR (B31-N014 A)

Reactor Bldg., Basement

- 22. GE Relay (Ell-A-K001A)

Aux Bldg., 2nd floor 23.

Bailey Diff. PressL(G33-N041)

Reactor Bldg., Basement 124.- GE Rack (H21'P025)

Reactor Bldg.,1st Floor 7 25.. Weed Inst. Temp Element (C41-N006)

Reactor Bldg., 4th Floor:

,