T

,

o ,

o;

1, . .

'

..,

i

i

FEB 0 51993

k

Docket No. 50 443

Public Service Company of New Hampshire

ATTN: Mr. Edward A. Brown, President

and Chief Executive Officer

New Hampshire Yankee Division-

Post Office Box 300

.Seabrook,-New Hampshire 03874

' Gentlemen:

Subject:- Inspection Report 50-443/89-17

This refers to the special safety inspection conducted by Mr. R. J. Paolino of

this office on November 6-10,11989 at Seabrook, New Hampshire and continued in

the. Region I office on' December 4, 1989 and to the discussions of our findings

held by Mr. Paolino with Mr. R. C. Feigenbaum and other members-of your staff-

at the conclusion of the inspection. The inspection covered activities

authorized by NRC License No. NPF-56.

Areas examined'during this inspection-are described in the NRC Region I

. Inspection Report which is enclosed with this letter. Within these areas, the

~.

inspection consisted of' selective examinations of procedures and representative.

records, interviews.with personnel, and observations by the inspector.

Based on the results of this inspection, it appears that one of your activities

was not conducted _in full compliance with NRC requirements,-as set forth in the

Notice of-Violation, enclosed herewith as Appendix A.

The violation' involves

licensee failure to demonstrate qualification of installed ASCO valves in a

steam environment.

This = violation has been categorized by Severity Level in accordance -with the

" General Statement of Policy and Procedure for NRC enforcement actions," 10

-

-CFR Part 2, Appendix C (Enforcement Policy). You are required to respond to

this letter and-in preparing your response, you should follow the instructions

in Appendix A.

Your cooperation with us in this matter is appreciated.

Sincerely,

,

Original Signed By-

,

William V. Johnston

i

Marvin W. Hodges, Director

g

Division of Reactor Safety

Enclosures:

1.

NRC Region I Inspection Report Number 50-443/89-17

2,

Appendix A,' Notice of Violation

0FFICIAL RECORD COPY

IR SEABROOK 89-17 - 0001.0.0

.

01/25/90

9002230181 9002059

jDR. ADOCK ODo g 3

Q ', g l .g\\ \\ .

-

\\

.

.

'

. , __

FEB 0 51990

-

-

!-

L*

Public Service Comp &ny of

2

'

'

New Hampshire

j

!

,

f

ec w/ enc 1:

1

J. C. Duffett, President and Chief Executive Officer, PSNH

l

T. C. Feigenbaum, Senior Vice President and Chief Operating Officer, NHY

'

J. M. Peschel, Operational Programs Manager, NHY

t.

D. E. Moody, Station Manager, NHY

T. Harpster, Director of Licensing Services

P. W. Agnes, Jr. , Assistant Secretary of Public Safety, Commonwealth of

Massachusetts

Public Document Room (PDR)

r

Local Public Document Room (LPDR)

Nuclear. Safety Information Center (NSIC)

NRC Resident-Inspector

,

,

!

State of New Hampshire

Commonwealth of Massachusetts

Seabrook Hearing-Service List-

bec w/ enc 1:

Region I Docket Room (vith concurrences)

Management Assistant, DRMA (w/o enc 1)

E. McCabe, DRP

J. Johnson, ORP

SRI - Seabrook (w/ concurrences)

V. Nerses, NRR

K. Abraham, PA0 (20) SALP Reports and All Inspection Reports

J. Dyer, EDO

i

RI:f9

C

i

DRS

R

ORS

RpuRA

I:RA[

RI:DR

Paolino pmb/rw

Anderson

D

'

M rt'in

R ss 1

1//K/90

1/gf/90

1/2)/90

p[/90

1/

90

RI:DRS

1

,

Hodgqgd

1/)(p/90

0FFICIAL RECORD COPY

IR SEABROOK 89-17 - 0002.0.0

01/18/90

.

,