LA CROSSE BOILING WATER REACTOR FINAL STATUS SURVEY RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 2

TABLE OF CONTENTS

1.

EXECUTIVE

SUMMARY

................................................................................................................................. 5

2.

SURVEY UNIT DESCRIPTION....................................................................................................................... 5

3.

CLASSIFICATION BASIS................................................................................................................................. 5

4.

DATA QUALITY OBJECTIVES...................................................................................................................... 6

5.

SURVEY DESIGN............................................................................................................................................... 9

6.

SURVEY IMPLEMENTATION...................................................................................................................... 13

7.

SURVEY RESULTS.......................................................................................................................................... 14

8.

QUALITY CONTROL...................................................................................................................................... 15

9.

INVESTIGATIONS AND RESULTS.............................................................................................................. 16

10. REMEDIATION AND RESULTS................................................................................................................... 16
11. CHANGES FROM THE FINAL STATUS SURVEY PLAN........................................................................ 16
12. DATA QUALITY ASSESSMENT................................................................................................................... 16
13. ANOMALIES..................................................................................................................................................... 17
14. CONCLUSION.................................................................................................................................................. 17
15. REFERENCES................................................................................................................................................... 17
16. ATTACHMENTS.............................................................................................................................................. 18 ATTACHMENT 1 - FIGURES AND MAPS............................................................................................................. 19 ATTACHMENT 2 - MEASUREMENT DATA.......................................................................................................... 22 ATTACHMENT 3 - SIGN TEST............................................................................................................................... 45 ATTACHMENT 4 - QUALITY CONTROL ASSESSMENT...................................................................................... 61 ATTACHMENT 5 - GRAPHICAL PRESENTATIONS............................................................................................. 63

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 3

LIST OF TABLES Table 4 Dose Significant Radionuclides and Mixture for Buried Pipe............................................................... 7 Table 4 Base Case DCGLs for Buried Pipe - Circulating Water Discharge Pipe............................................. 8 Table 4 Operational DCGLs for Buried Pipe - Circulating Water Discharge Pipe......................................... 9 Table 5 Soil Surrogate Ratio................................................................................................................................. 9 Table 5 Investigation Levels................................................................................................................................ 12 Table 5 Synopsis of Survey Design...................................................................................................................... 12 Table 7 Summary of Systematic, Judgmental, and QC Measurements........................................................... 15 Table 7 Basic Statistical Properties of the Systematic Measurement Population............................................ 15 Table 16 Survey Unit S1-011-102 Static Measurements Data Assessment...................................................... 23 Table 16 Survey Unit S1-011-102 Sign Test....................................................................................................... 46 Table 16 Survey Unit S1-011-102 QC Assessment............................................................................................. 62 LIST OF FIGURES Figure 16 Survey Unit S1-011-102 Drawing....................................................................................................... 20 Figure 16 Survey Unit S1-011-102 Measurement Position Designations......................................................... 21 Figure 16 Quantile Plot for Gross Gamma Activity.......................................................................................... 64 Figure 16 Histogram for Gross Gamma Activity............................................................................................... 65 Figure 16 Retrospective Power Curve for Survey Unit S1-011-102................................................................. 66

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 4

LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable CWD Circulating Water Discharge DQO Data Quality Objective DCGL Derived Concentration Guideline Level DCGLBP Buried Pipe Base Case Derived Concentration Guideline Level FSS Final Status Survey HSA Historical Site Assessment IC Insignificant Contributors ID Internal Diameter LACBWR La Crosse Boiling Water Reactor LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MCNP Monte Carlo Neutral Particle MDC Minimum Detectable Concentration NaI Sodium Iodide OpDCGLBP Buried Pipe Operational Derived Concentration Guideline Level QAPP Quality Assurance Project Plan QC Quality Control ROC Radionuclides of Concern SOF Sum-of-Fractions TEDE Total Effective Dose Equivalent TSD Technical Support Document UCL Upper Confidence Limit

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 5

1.

EXECUTIVE

SUMMARY

This Final Status Survey (FSS) Release Record for survey unit S1-011-102, Circulating Water Discharge (CWD) Pipe, has been generated in accordance with LaCrosseSolutions procedure LC-FS-PR-009, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the La Crosse Boiling Water Reactor License Termination Plan (LACBWR LTP) (Reference 2).

An FSS sample plan for this survey unit was developed in accordance with LaCrosseSolutions procedures LC-FS-PR-002, Final Status Survey Package Development (Reference 3) and LC-FS-PR-018, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors (Reference 4), the LACBWR LTP, and with guidance from NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 5).

Survey unit S1-011-102 has a MARSSIM classification of 1. A survey plan was designed based upon use of the Sign Test as the nonparametric statistical test for compliance. Both the Type I () and Type II () decision error rates were set at 0.05. As a systematic measurement population, five hundred and ten (510) static gamma measurements were acquired from the survey unit. The data assessment results for survey unit S1-011-102 indicate that the maximum Sum-of-Fractions (SOF), considering the concentration of all applicable Radionuclides of Concern (ROC) either by direct measurement or by inference, is equal to 0.1131 when applying the respective Operational Derived Concentration Guideline Levels (OpDCGLBP) for buried pipe. The mean SOF when applying the respective Base Case DCGLs (DCGLBP) is 0.0012. This SOF equates to a dose for the survey unit of 0.0299 mrem/yr.

2.

SURVEY UNIT DESCRIPTION S1-011-102 is an impacted Class 1 buried pipe survey unit. The survey unit consists of the interior surface of the CWD Pipe. The steel pipe has an internal diameter (ID) of 60 inches and a total length of 421 feet. The pipe runs from the Turbine Building to a combined discharge structure on the banks of the Mississippi River. The interior surface area of the CWD Pipe is 614.37 m2 (6,143,736.42 cm2). Refer to Attachment 1 of this report for figures and maps depicting survey unit S1-011-102.

3.

CLASSIFICATION BASIS Based on the La Crosse Boiling Water Reactor Historical Site Assessment (HSA)

(Reference 6), the CWD Pipe was identified as a Class 1 system.

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 6

Based upon review of the historical information and completion of a final Survey Unit Classification Worksheet from LC-FS-PR-006, Survey Unit Classification (Reference 7),

the correct final classification of survey unit S1-011-102 was determined to be Class 1.

4.

DATA QUALITY OBJECTIVES FSS planning and design relies on a properly executed Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process is described in the LACBWR LTP in accordance with MARSSIM. The appropriate design for a given survey was developed using the DQO process as outlined in Appendix D of MARSSIM.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.

The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in survey unit S1-011-102 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

EnergySolutions Technical Support Document (TSD) RS-TD-313196-001, Radionuclides of Concern during LACBWR Decommissioning (Reference 8) established the basis for an initial suite of potential ROC for decommissioning. Insignificant contributors (IC) were determined consistent with the guidance contained in Section 3.3 of NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance - Characterization, Survey, and Determination of Radiological Criteria, Final Report (Reference 9). In all soil and concrete scenarios, Cs-137, Co-60, Sr-90, Eu-152 and Eu-154 contribute nearly 100% of the total dose. The remaining radionuclides were designated as IC and are eliminated from further detailed evaluation. Therefore, the final ROCs for LACBWR soil, basement concrete, and buried piping are Cs-137, Co-60, Sr-90, Eu-152 and Eu-154.

LTP, Section 6.14.1 discusses the process used to derive the ROC for the decommissioning of LACBWR, including the elimination of IC from the initial suite. Table 4-1 presents the

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 7

ROC for the decommissioning of buried pipe at LACBWR and the normalized mixture fractions based on the radionuclide mixture.

Table 4 Dose Significant Radionuclides and Mixture for Buried Pipe Radionuclide Fraction of Total Activity (normalized)(1)

Co-60 0.064 Sr-90 0.098 Cs-137 0.829 Eu-152 0.005 Eu-154 0.003 (1) Based on maximum percent of total activity from Table 22 of RS-TD-313196-001, normalized to one for the dose significant radionuclides.

The LTP, Section 5.2, states that each radionuclide-specific Base Case DCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem/yr to an Average Member of the Critical Group. To ensure that the summation of dose from each source term is 25 mrem/yr or less after all FSS is completed, the Base Case DCGLs are reduced based on an expected, or a priori, fraction of the 25 mrem/yr dose limit from each source term. The reduced DCGLs, or Operational DCGLs, can be related to the Base Case DCGLs as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge, and the extent of planned remediation. The Operational DCGL is then used as the DCGL for the FSS design of the survey unit (i.e., calculation of surrogate DCGLs and investigations levels). Details of the Operational DCGLs derived for each dose component and the basis for the applied a priori dose fractions are provided in LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey (Reference 10).

The dose contribution from each ROC is accounted for using the SOF to ensure that the total dose from all ROC does not exceed the dose criterion. A Base Case DCGL that is established for the average residual radioactivity in a survey unit is equivalent to a DCGLW.

The DCGLW can be multiplied by Area Factors to obtain a Base Case DCGL that represents the same dose to an individual for residual radioactivity over a smaller area within a survey unit.

At LACBWR, compliance is demonstrated through the summation of dose from five (5) distinct source terms for the end state (basements, soils, buried pipe, above-ground structures, and groundwater). When applied to buried pipe, the DCGLs are expressed in units of activity per surface area (dpm/100 cm2).

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 8

Buried piping is defined as below ground pipe located outside of structures and basements.

The dose assessment methods and resulting DCGLs for buried piping are described in detail in LTP, Section 6.20. The buried piping was separated into two categories. The first category included the summation and grouping of all impacted buried pipe other than the CWD Pipe and is designated as the Buried Pipe Group. The second category consisted of the CWD Pipe only. The separation of the Circulating Water pipe was necessary because the geometry of the CWD pipe was significantly different than the other pipes, and the pipes are located in distinctly different parts of the site.

EnergySolutions TSD RS-TD-313196-004, LACBWR Soil DCGL, Basement Concrete DCGL, and Buried Pipe DCGL (Reference 11) and LTP, Section 6.20, provide the exposure scenarios and modeling parameters that were used to calculate the site-specific buried pipe DCGLs. The final DCGLs to be used during FSS account for the fact that the dose from the In Situ and Excavation scenarios must be summed in the conceptual model for buried pipe dose assessment (i.e., the In Situ and Excavation scenarios occur in parallel). The summed Buried Pipe Base Case DCGLs are reproduced in Table 4-2 below. The IC dose percentages for each of the buried pipe scenarios were used to adjust each buried pipe Base Case DCGL to account for the dose from the eliminated IC radionuclides. The Operational DCGLs for the CWD Pipe are provided in Table 4-3.

Table 4 Base Case DCGLs for Buried Pipe - Circulating Water Discharge Pipe Radionuclide DCGLBP (dpm/100 cm2)

Co-60 7.75E+04 Sr-90 7.55E+05 Cs-137 3.30E+05 Eu-152 1.67E+05 Eu-154 1.56E+05

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 9

Table 4 Operational DCGLs for Buried Pipe - Circulating Water Discharge Pipe Radionuclide OpDCGLBP (dpm/100 cm2)

Co-60 1.63E+04 Sr-90 1.58E+05 Cs-137 6.94E+04 Eu-152 3.51E+04 Eu-154 3.27E+04 Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the Operational DCGL. Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

In accordance with the LTP, the minimum acceptable MDC for measurements obtained using field instruments was 50% of the applicable Operational DCGL.

5.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey unit and nature of the hazards. Guidance for preparing FSS plans is provided in procedure LC-FS-PR-002, Final Status Survey Package Development.

The DQO process validated that Co-60, Sr-90, Cs-137, Eu-152, and Eu-154 would be the ROC in survey unit S1-011-102 as presented in LTP, Section 5.1. During the data analysis of the FSS results, concentrations for the HTD ROC Sr-90 are inferred using a surrogate approach. Cs-137 is the principle surrogate radionuclide for Sr-90. During characterization, both Sr-90 and Cs-137 was positively detected in all thirty (30) concrete core samples assessed in the Reactor Building, Tunnel, and Waste Treatment Building. The 95% Upper Confidence Limit (UCL) of the Cs-137 fractions was chosen to represent the overall nuclide mix for soils/buried pipe, the Reactor Building, and the Waste Gas Tank Vault. The surrogate ratio for soil/buried pipe is given in Table 5-1.

Table 5 Soil Surrogate Ratio Radionuclides Ratio Sr-90/Cs-137 0.502 The equation for calculating a surrogate DCGL is as follows:

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 10 Equation 1

=

1

[(

1

) + (

2

2) + (

3

3) + (

)]

Where:

DCGLSur

= Surrogate radionuclide DCGL DCGL2,3n = DCGL for radionuclides to be represented by the surrogate Rn

= Ratio of concentration (or nuclide mixture fraction) of radionuclide n to surrogate radionuclide Using the Operational DCGLs presented in Table 4-3 and the ratio from Table 5-1, the following surrogate calculation was performed:

Equation 2 (137) =

1

[(

1 6.94+ 04(137)) + (

0.502 1.58+ 05(90))]

= 5.69+ 04 /100 2 The surrogate Operational DCGL for Cs-137 is then used in the calculation of the gross gamma Operational DCGL, as calculated in Equation 3.

Equation 3

()

=

1

[(

0.071 1.63+ 04(60)) + (

0.919 5.69+ 04137) + (

0.006 3.51+ 04(152)) + (

0.003 3.27+ 04(154))]

= 4.81+ 04 /100 2 The action level for survey unit S1-011-102 was equivalent to the calculated gross gamma Operational DCGL of 4.81E+04 dpm/100 cm2.

For the survey of interior pipe surfaces, areal coverage is achieved by the area of detection for each static measurement collected. Scanning, in the traditional context, is not applicable to the survey of pipe internal surfaces. For the survey of the CWD Pipe, the detector was erroneously calibrated for a specific geometry of a 3,050 cm2 (1 ft x 1 m) area of contamination on the bottom of the pipe, resulting in inaccurate detector efficiencies and inaccurate calculations for activity per area. TSD LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor (Reference 12) was written

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 11 to address the discrepancy in efficiency and area of detection. The TSD details the Monte Carlo Neutral Particle (MCNP) radiation transport code that modeled the response of a NaI detector to a calibration source for several different pipe sizes. The MCNP models resulted in efficiency correction factors. The calculated efficiency from original source calibration can be multiplied by the correction factors to obtain an efficiency that more realistically portrays the specific contamination geometry of the pipe. For a 60 ID pipe, each measurement has a true Field-of-View (FOV) of 14,590 cm2.

The CWD Pipe contains 421 linear feet of 60 ID steel piping, which equates to a surface area of 614.37 m2 (6,143,736.42 cm2). The LTP states that a Class 1 FSS survey unit shall have an areal coverage of 100%. Therefore, one (1) measurement was to be collected every one (1) linear foot traversed through the pipe, for a total of at least four hundred and twenty-one (421) distinct measurements over the entire accessible pathway of the piping system.

During survey design, eighty-nine (89) systematic static measurements (approximately four

[4] every twenty [20] feet) were added in an effort to assess the sides and top of the pipe (see Figure 16-2), for a total of five hundred and ten (510) static measurements that make up the systematic measurement population.

Each static measurement represents the gamma activity in gross counts per minute (cpm) for each specific measurement location. Background is subtracted, then the value is converted to dpm using an efficiency factor based on the calibration source and the efficiency correction factors detailed in TSD LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor. The total activity in dpm is then adjusted for the assumed effective surface area commensurate with the pipe diameter, resulting in units of dpm/100 cm2. The total gamma surface activity for each measurement was converted to an activity concentration for each gamma-emitting ROC, based on the normalized gamma mixture from Table 4-1. Concentrations for the HTD ROC Sr-90 were inferred using the surrogate approach in accordance with LTP Chapter 5.

The implementation of quality control measures as referenced by LTP, Section 5.9 and LaCrosseSolutions LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan (QAPP) (Reference 13) includes the collection of replicate static measurements on 5% of the systematic measurements collected in the survey unit, with the locations selected at random. Twenty-five (25) replicate static measurements were selected for Quality Control (QC) analysis for the FSS of this survey unit.

For this Class 1 buried pipe survey unit, the Investigation Levels for measurement results are those levels specified in LTP Chapter 5, Table 5-16, and are reproduced below in Table 5-2.

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 12 Table 5 Investigation Levels Classification Scan Investigation Levels Direct Investigation Levels Class 1

>Operational DCGL or >MDCscan if MDCscan is greater than Operational DCGL

>Operational DCGL Table 5-3 provides a synopsis of the survey design for survey unit S1-011-102.

Table 5 Synopsis of Survey Design Feature Design Criteria Basis Survey Unit Surface Area 614.37 m2 (6,143,736.42 cm2) 421 421 of 60 diameter steel pipe Number of Systematic Measurements (N) 510 100% coverage Operational DCGLs (dpm/100 cm2)

Co-60: 1.63E+04 Sr-90: 1.58E+05 Cs-137: 6.94E+04 Eu-152: 3.51E+04 Eu-154: 3.27E+04 Operational DCGLs for buried pipe, LTP, Table 5-8, Release Record, Table 4-3 Action Level 4.81E+04 dpm/100 cm2 Gross Gamma Operational DCGL, Equation 3 Investigation Level

>Operational DCGL LTP, Table 5-16 Scan Areal Coverage N/A LTP, Section 5.7.1.8 Number of Judgmental Measurements 1

2 Per Sample Plan Actual Number Obtained QC 25 replicate measurements LTP, Section 5.9 Non-parametric Statistical Test Sign Test LTP, Section 5.6.4.2

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 13

6.

SURVEY IMPLEMENTATION FSS field activities were conducted under the FSS sample plan, which included DQOs, survey design, detailed FSS instructions, job safety analysis, and related procedures for reference. The survey unit was inspected and controlled in accordance with LC-FS-PR-010, Isolation and Control for Final Status Survey (Reference 14). A Field Log was used to document field activities and other information pertaining to the performance of the FSS.

FSS field activities commenced on April 22, 2018.

FSS field activities were projected to take four (4) working days to complete. Daily briefings were conducted to discuss the expectations for job performance and to review safety aspects of the job. The survey-required field activities were performed during normal working hours and concluded on April 25, 2018.

Background measurements were acquired in the North Yard area of the site. These readings were found to be inconsistent with the activity measured in the pipe; nearly all measurements were negative after subtracting background. It was determined that the backgrounds originally collected for the CWD pipe were not representative of true background levels. Because the CWD pipe was no longer accessible after survey implementation, a background value was developed from the existing survey data. TSD LC-FS-TSD-003, Assessment of the LACBWR Circulating Water Discharge Pipe Final Status Survey Data for Detection Efficiency and Detector Background (Reference 15) details the process and justification for using a mean value of the data as a reasonable background value.

Daily, prior to and following use, each detector was subjected to an Operational Response Check in accordance with procedure LC-FS-PR-018, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors. The Daily Operational Response Check compared the background response and the response to check source ranges established for normal background and detector source response to ensure that the detector was working properly.

The five hundred and ten (510) systematic 1-minute static measurements were collected using a Ludlum Model 2350-1 paired with a Model 44-10 NaI detector operated in the rate-meter mode and using audio response. The detector was fitted into a wheeled rig, which maintained a fixed detector geometry, an area of detection of 14,590 cm2. The static MDC was sufficient to detect residual radioactivity at the action level (adjusted gross gamma Operational DCGL of 4.81E+04 dpm/100 cm2). Complete measurement results are provided in Attachment 2.

Two (2) judgmental static measurements were collected during implementation of FSS.

The implementation of survey specific QC measures included the collection of twenty-five (25) replicate static measurements for QC analysis.

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 14

7.

SURVEY RESULTS The SOF or unity rule is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The equation for the unity rule is:

Equation 4 Where:

Cn

= concentration of radionuclide n DCGLn

= DCGL of radionuclide n.

The application of the unity rule serves to normalize the data to allow for an accurate comparison of the various data measurements to the release criteria. When the unity rule is applied, the DCGLW (used for the nonparametric statistical test) becomes one (1). The DCGLBP are directly analogous to the DCGLW as defined in MARSSIM. The use and application of the unity rule was performed in accordance with section 4.3.3 of MARSSIM.

As described in LTP, Section 5.10.3.2, the Sign Test was used to evaluate the measured residual radioactivity against the dose criterion. The SOF for each measurement was used as the sum value for the Sign Test. The Sign Test then demonstrated that the mean activity for each ROC was less than the OpDCGLBP at a Type I decision error of 0.05. The results of the Sign Test are presented in Attachment 3.

For buried pipe, areas of elevated activity were defined as any area identified by measurement (systematic or judgmental) that exceeded the OpDCGLBP but was less than the DCGLBP. The SOF (based on the OpDCGLB) for a systematic or judgmental measurement can exceed one (1) without remediation as long as the survey unit passes the Sign Test, and the mean SOF (based on the OpDCGLBP) for the survey unit does not exceed one (1). Once the survey data set passes the Sign Test (using Operational DCGLs), then the mean radionuclide activity for each ROC from systematic measurements along with any identified elevated areas from systematic and judgmental samples can be used with the Base Case DCGLs to perform a mean SOFBP calculation. The dose from residual radioactivity assigned to the FSS unit is the mean SOFBP multiplied by 25 mrem/yr.

The systematic measurement population consisted of five hundred and ten (510) static measurements that were acquired using the Ludlum Model 2350-1 paired to a Model 44-10 detector. In total, five hundred and thirty-seven (537) static measurements were collected, including the systematic, judgmental, and QC measurements. A breakdown of the total static measurements and SOF for systematic measurements compared to the OpDCGLBP is provided in Table 7-1. A summary of the results of the systematic measurements taken for 1

2 2

1 1

DCGL C

DCGL C

DCGL C

n n

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 15 non-parametric statistical testing when compared to the DCGLBP is provided in Table 7-2.

The complete results of the data assessment for survey unit S1-011-102 are provided in.

Table 7 Summary of Systematic, Judgmental, and QC Measurements Total Number of Systematic Measurements 510 Number of Quality Control Measurements 25 Number of Judgmental Measurements 2

Total Number of Measurements 537 Mean Systematic Measurement SOF (1) 0.0057 Max Individual Systematic Measurement SOF (1) 0.1131 Number of Systematic Measurements with SOF > 1 (1) 0 Number of Judgmental Measurements with SOF > 1 (1) 0 (1) Based on the OpDCGLBP Table 7 Basic Statistical Properties of the Systematic Measurement Population ROC Mean Median Min Max St. Dev.

(dpm/100 cm2)

BcDCGL Avg. SOF per ROC Avg. Dose per ROC (dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

Co-60 1.95E+01 0.00E+00 3.88E+02 0.00E+00 5.26E+01 7.75E+04 0.0003 0.0063 Cs-137 2.51E+02 0.00E+00 5.00E+03 0.00E+00 6.77E+02 3.30E+05 0.0008 0.0190 Eu-152 1.67E+00 0.00E+00 3.31E+01 0.00E+00 4.49E+00 1.67E+05 0.0000 0.0002 Eu-154 8.52E-01 0.00E+00 1.69E+01 0.00E+00 2.30E+00 1.56E+05 0.0000 0.0001 Sr-90 1.26E+02 0.00E+00 2.51E+03 0.00E+00 3.40E+02 7.55E+05 0.0002 0.0042 SUM 0.0012 0.0299 The mean SOF for the CWD Pipe, based on the mean concentration for each ROC as measured by the systematic measurement population when compared against the DCGLBP, is 0.0012. This SOF equates to a dose of 0.0299 mrem/yr.

8.

QUALITY CONTROL The implementation of survey specific QC measures included the collection of twenty-five (25) replicate static measurements for QC analysis. The acceptance criteria for replicate static measurements is that the same conclusion is reached for each measurement. This is defined as the replicate measurement being within 20% of the standard measurement. In cases where the replicate measurement is not within 20% of the standard measurement, but both measurements are below the Operational DCGL, there is an acceptable agreement.

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 16 Fourteen (14) QC replicate measurement did not fall within the 20% criteria, but both the standard and replicate measurements were well below the Operational DCGL. No further action was deemed necessary, and there is an acceptable agreement between standard and replicate results. Refer to Attachment 4 for QC analysis results.

9.

INVESTIGATIONS AND RESULTS No investigations were performed during the performance or analyses of the survey.

10.

REMEDIATION AND RESULTS No radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit. Chapter 4 of the LTP determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in buried pipe was ALARA.

11.

CHANGES FROM THE FINAL STATUS SURVEY PLAN TSDs LC-FS-TSD-003, Assessment of the LACBWR Circulating Water Discharge Pipe Final Status Survey Data for Detection Efficiency and Detector Background, and LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor, were developed in response to inaccurate efficiency calibration geometries and backgrounds originally assumed in the sample plan and during survey implementation.

12.

DATA QUALITY ASSESSMENT The DQO survey design and data were reviewed in accordance with LC-FS-PR-008, Final Status Survey Data Assessment (Reference 16) for completeness and consistency.

Documentation was complete and legible. Surveys were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1. The survey design had adequate power as indicated by the Retrospective Power Curve (see Attachment 5).

All measurements were less than a SOF of one (1) when compared to the OpDCGLBP.

The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results clearly demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). All data was considered valid including negative values, zeros, values reported below the MDC, and values with uncertainties that exceeded two standard deviations. The mean and median values for each ROC were well below the respective

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 17 Operational DCGLs. Also, the retrospective power curve shows that a sufficient number of measurements were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

13.

ANOMALIES No anomalies were observed during the performance or analyses of the survey.

14.

CONCLUSION Survey unit S1-011-102 has met the DQOs of the FSS plan. The ALARA criteria as specified in Chapter 4 of the LTP were achieved.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve showed that adequate power was achieved. The survey unit is properly classified as Class 1. Therefore, in accordance with LTP Section 5.11, the survey unit meets the release criteria.

The dose contribution from survey unit S1-011-102 is 0.0299 mrem/yr TEDE, based on the average concentration of the ROC in measurements used for non-parametric statistical testing (mean SOF).

Survey unit S1-011-102 is acceptable for unrestricted release.

15.

REFERENCES

1. LC-FS-PR-009, Final Status Survey Data Reporting
2. La Crosse Boiling Water Reactor License Termination Plan
3. LC-FS-PR-002, Final Status Survey Package Development
4. LC-FS-PR-018, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors
5. NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual
6. La Crosse Boiling Water Reactor Historical Site Assessment
7. LC-FS-PR-006, Survey Unit Classification
8. RS-TD-313196-001, Radionuclides of Concern during LACBWR Decommissioning
9. NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance -

Characterization, Survey, and Determination of Radiological Criteria, Final Report

10. LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey DCGL
11. RS-TD-313196-004, LACBWR Soil DCGL, Basement Concrete DCGL, and Buried Pipe

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 18

12. LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor
13. LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan
14. LC-FS-PR-010, Isolation and Control for Final Status Survey
15. LC-FS-TSD-003, Assessment of the LACBWR Circulating Water Discharge Pipe Final Status Survey Data for Detection Efficiency and Detector Background
16. LC-FS-PR-008, Final Status Survey Data Assessment
16.

ATTACHMENTS

- Figures and Maps

- Measurement Data

- Sign Test

- Quality Control Assessment

- Graphical Presentations

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 19 ATTACHMENT 1 FIGURES AND MAPS

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 20 Figure 16 Survey Unit S1-011-102 Drawing

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 21 Figure 16 Survey Unit S1-011-102 Measurement Position Designations

22 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 ATTACHMENT 2 MEASUREMENT DATA

23 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Table 16 Survey Unit S1-011-102 Static Measurements Data Assessment Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

G01 603 4.30E+01 5.54E+02 3.67E+00 1.88E+00 2.78E+02 0.0026 0.0080 0.0001 0.0001 0.0018 0.0125 S

H01 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I01 11 7.73E-01 9.95E+00 6.59E-02 3.37E-02 5.00E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 S

J01 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G03 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H03 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I03 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J03 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G04 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H04 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I04 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J04 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G05 453 3.23E+01 4.16E+02 2.76E+00 1.41E+00 2.09E+02 0.0020 0.0060 0.0001 0.0000 0.0013 0.0094 S

H05 193 1.38E+01 1.77E+02 1.18E+00 6.02E-01 8.91E+01 0.0008 0.0026 0.0000 0.0000 0.0006 0.0040 S

I05 319 2.28E+01 2.94E+02 1.94E+00 9.95E-01 1.47E+02 0.0014 0.0042 0.0001 0.0000 0.0009 0.0066 S

J05 691 4.94E+01 6.35E+02 4.21E+00 2.15E+00 3.19E+02 0.0030 0.0092 0.0001 0.0001 0.0020 0.0144 S

G06 171 1.22E+01 1.58E+02 1.04E+00 5.34E-01 7.91E+01 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 S

H06 211 1.51E+01 1.94E+02 1.29E+00 6.58E-01 9.74E+01 0.0009 0.0028 0.0000 0.0000 0.0006 0.0044 S

I06 150 1.07E+01 1.38E+02 9.12E-01 4.67E-01 6.91E+01 0.0007 0.0020 0.0000 0.0000 0.0004 0.0031 S

J06 69 4.90E+00 6.30E+01 4.17E-01 2.14E-01 3.16E+01 0.0003 0.0009 0.0000 0.0000 0.0002 0.0014

24 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

G07 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H07 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I07 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J07 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G08 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H08 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I08 43 3.09E+00 3.98E+01 2.64E-01 1.35E-01 2.00E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 S

J08 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G09 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H09 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I09 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J09 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G10 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H10 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I10 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J10 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G11 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H11 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I11 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J11 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G12 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H12 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I12 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J12 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G13 184 1.31E+01 1.69E+02 1.12E+00 5.73E-01 8.49E+01 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038

25 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

H13 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I13 60 4.25E+00 5.47E+01 3.62E-01 1.86E-01 2.75E+01 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 S

J13 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G14 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

H14 18 1.29E+00 1.66E+01 1.10E-01 5.62E-02 8.33E+00 0.0001 0.0002 0.0000 0.0000 0.0001 0.0004 S

I14 7

5.15E-01 6.63E+00 4.39E-02 2.25E-02 3.33E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 S

J14 74 5.28E+00 6.80E+01 4.50E-01 2.31E-01 3.41E+01 0.0003 0.0010 0.0000 0.0000 0.0002 0.0015 S

G15 144 1.03E+01 1.33E+02 8.79E-01 4.50E-01 6.66E+01 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 S

H15 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I15 14 1.03E+00 1.33E+01 8.79E-02 4.50E-02 6.66E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003 S

J15 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G16 420 3.00E+01 3.86E+02 2.56E+00 1.31E+00 1.94E+02 0.0018 0.0056 0.0001 0.0000 0.0012 0.0088 S

H16 67 4.77E+00 6.14E+01 4.06E-01 2.08E-01 3.08E+01 0.0003 0.0009 0.0000 0.0000 0.0002 0.0014 S

I16 218 1.56E+01 2.01E+02 1.33E+00 6.80E-01 1.01E+02 0.0010 0.0029 0.0000 0.0000 0.0006 0.0045 S

J16 175 1.25E+01 1.61E+02 1.07E+00 5.45E-01 8.08E+01 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 S

G17 671 4.79E+01 6.17E+02 4.09E+00 2.09E+00 3.10E+02 0.0029 0.0089 0.0001 0.0001 0.0020 0.0140 S

H17 709 5.06E+01 6.52E+02 4.32E+00 2.21E+00 3.27E+02 0.0031 0.0094 0.0001 0.0001 0.0021 0.0148 S

I17 880 6.29E+01 8.09E+02 5.36E+00 2.74E+00 4.06E+02 0.0039 0.0117 0.0002 0.0001 0.0026 0.0183 S

J17 651 4.65E+01 5.99E+02 3.97E+00 2.03E+00 3.01E+02 0.0029 0.0086 0.0001 0.0001 0.0019 0.0136 S

G18 514 3.67E+01 4.73E+02 3.13E+00 1.60E+00 2.37E+02 0.0023 0.0068 0.0001 0.0000 0.0015 0.0107 S

H18 563 4.02E+01 5.18E+02 3.43E+00 1.75E+00 2.60E+02 0.0025 0.0075 0.0001 0.0001 0.0016 0.0117 S

I18 485 3.47E+01 4.46E+02 2.95E+00 1.51E+00 2.24E+02 0.0021 0.0064 0.0001 0.0000 0.0014 0.0101 S

J18 548 3.92E+01 5.04E+02 3.34E+00 1.71E+00 2.53E+02 0.0024 0.0073 0.0001 0.0001 0.0016 0.0114 S

G19 440 3.14E+01 4.05E+02 2.68E+00 1.37E+00 2.03E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0092 S

H19 229 1.64E+01 2.11E+02 1.40E+00 7.14E-01 1.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048

26 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

I19 318 2.27E+01 2.92E+02 1.93E+00 9.90E-01 1.47E+02 0.0014 0.0042 0.0001 0.0000 0.0009 0.0066 S

J19 213 1.52E+01 1.96E+02 1.30E+00 6.63E-01 9.83E+01 0.0009 0.0028 0.0000 0.0000 0.0006 0.0044 S

G20 124 8.89E+00 1.14E+02 7.58E-01 3.88E-01 5.75E+01 0.0005 0.0016 0.0000 0.0000 0.0004 0.0026 S

H20 217 1.55E+01 1.99E+02 1.32E+00 6.75E-01 9.99E+01 0.0009 0.0029 0.0000 0.0000 0.0006 0.0045 S

I20 128 9.15E+00 1.18E+02 7.80E-01 3.99E-01 5.91E+01 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 S

J20 303 2.16E+01 2.79E+02 1.85E+00 9.45E-01 1.40E+02 0.0013 0.0040 0.0001 0.0000 0.0009 0.0063 S

G21 41 2.96E+00 3.82E+01 2.53E-01 1.29E-01 1.92E+01 0.0002 0.0005 0.0000 0.0000 0.0001 0.0009 S

H21 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

I21 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

J21 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

G22 4058 2.90E+02 3.73E+03 2.47E+01 1.26E+01 1.87E+03 0.0178 0.0538 0.0007 0.0004 0.0119 0.0845 S

H22 5434 3.88E+02 5.00E+03 3.31E+01 1.69E+01 2.51E+03 0.0238 0.0720 0.0009 0.0005 0.0159 0.1131 S

I22 5346 3.82E+02 4.91E+03 3.25E+01 1.67E+01 2.47E+03 0.0234 0.0708 0.0009 0.0005 0.0156 0.1113 S

J22 4592 3.28E+02 4.22E+03 2.80E+01 1.43E+01 2.12E+03 0.0201 0.0608 0.0008 0.0004 0.0134 0.0956 S

A00 949 6.78E+01 8.72E+02 5.78E+00 2.96E+00 4.38E+02 0.0042 0.0126 0.0002 0.0001 0.0028 0.0198 S

A01 395 2.82E+01 3.63E+02 2.41E+00 1.23E+00 1.82E+02 0.0017 0.0052 0.0001 0.0000 0.0012 0.0082 S

A02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A03 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A04 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A05 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A06 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A07 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A08 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A09 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A10 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

27 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

A11 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A12 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A13 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A14 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A15 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A16 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A17 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A18 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A19 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A20 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A21 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A22 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A23 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A24 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A25 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A26 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A27 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A28 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A29 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A30 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A31 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A32 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A33 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A34 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A35 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

28 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

A36 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A37 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A38 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A39 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A40 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A41 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A42 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A43 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A44 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A45 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A46 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A47 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A48 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A49 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A50 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A51 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A52 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A53 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A54 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A55 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A56 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A57 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A58 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A59 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A60 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

29 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

A61 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A62 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A63 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A64 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A65 70 5.03E+00 6.47E+01 4.28E-01 2.19E-01 3.25E+01 0.0003 0.0009 0.0000 0.0000 0.0002 0.0015 S

A66 159 1.13E+01 1.46E+02 9.67E-01 4.95E-01 7.33E+01 0.0007 0.0021 0.0000 0.0000 0.0005 0.0033 S

A67 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A68 88 6.31E+00 8.13E+01 5.38E-01 2.75E-01 4.08E+01 0.0004 0.0012 0.0000 0.0000 0.0003 0.0018 S

A69 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A70 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

A71 202 1.44E+01 1.86E+02 1.23E+00 6.30E-01 9.33E+01 0.0009 0.0027 0.0000 0.0000 0.0006 0.0042 S

A72 597 4.27E+01 5.49E+02 3.64E+00 1.86E+00 2.76E+02 0.0026 0.0079 0.0001 0.0001 0.0017 0.0124 S

A73 520 3.71E+01 4.78E+02 3.16E+00 1.62E+00 2.40E+02 0.0023 0.0069 0.0001 0.0000 0.0015 0.0108 S

A74 462 3.30E+01 4.25E+02 2.81E+00 1.44E+00 2.13E+02 0.0020 0.0061 0.0001 0.0000 0.0013 0.0096 S

A75 586 4.19E+01 5.39E+02 3.57E+00 1.83E+00 2.71E+02 0.0026 0.0078 0.0001 0.0001 0.0017 0.0122 S

A76 339 2.42E+01 3.12E+02 2.07E+00 1.06E+00 1.57E+02 0.0015 0.0045 0.0001 0.0000 0.0010 0.0071 S

A77 411 2.94E+01 3.78E+02 2.50E+00 1.28E+00 1.90E+02 0.0018 0.0054 0.0001 0.0000 0.0012 0.0086 S

A78 527 3.76E+01 4.84E+02 3.21E+00 1.64E+00 2.43E+02 0.0023 0.0070 0.0001 0.0001 0.0015 0.0110 S

A79 384 2.74E+01 3.53E+02 2.34E+00 1.20E+00 1.77E+02 0.0017 0.0051 0.0001 0.0000 0.0011 0.0080 S

A80 328 2.35E+01 3.02E+02 2.00E+00 1.02E+00 1.52E+02 0.0014 0.0043 0.0001 0.0000 0.0010 0.0068 S

A81 429 3.07E+01 3.95E+02 2.61E+00 1.34E+00 1.98E+02 0.0019 0.0057 0.0001 0.0000 0.0013 0.0089 S

A82 363 2.59E+01 3.33E+02 2.21E+00 1.13E+00 1.67E+02 0.0016 0.0048 0.0001 0.0000 0.0011 0.0075 S

A83 175 1.25E+01 1.61E+02 1.07E+00 5.45E-01 8.08E+01 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 S

A84 280 2.00E+01 2.57E+02 1.70E+00 8.71E-01 1.29E+02 0.0012 0.0037 0.0000 0.0000 0.0008 0.0058 S

A85 437 3.12E+01 4.01E+02 2.66E+00 1.36E+00 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091

30 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

A86 384 2.74E+01 3.53E+02 2.34E+00 1.20E+00 1.77E+02 0.0017 0.0051 0.0001 0.0000 0.0011 0.0080 S

A87 251 1.79E+01 2.31E+02 1.53E+00 7.82E-01 1.16E+02 0.0011 0.0033 0.0000 0.0000 0.0007 0.0052 S

A88 538 3.84E+01 4.94E+02 3.27E+00 1.68E+00 2.48E+02 0.0024 0.0071 0.0001 0.0001 0.0016 0.0112 S

A89 431 3.08E+01 3.96E+02 2.63E+00 1.34E+00 1.99E+02 0.0019 0.0057 0.0001 0.0000 0.0013 0.0090 S

A90 355 2.54E+01 3.27E+02 2.16E+00 1.11E+00 1.64E+02 0.0016 0.0047 0.0001 0.0000 0.0010 0.0074 S

A91 484 3.45E+01 4.45E+02 2.94E+00 1.51E+00 2.23E+02 0.0021 0.0064 0.0001 0.0000 0.0014 0.0101 S

A92 251 1.79E+01 2.31E+02 1.53E+00 7.82E-01 1.16E+02 0.0011 0.0033 0.0000 0.0000 0.0007 0.0052 S

A93 217 1.55E+01 1.99E+02 1.32E+00 6.75E-01 9.99E+01 0.0009 0.0029 0.0000 0.0000 0.0006 0.0045 S

A94 280 2.00E+01 2.57E+02 1.70E+00 8.71E-01 1.29E+02 0.0012 0.0037 0.0000 0.0000 0.0008 0.0058 S

A95 585 4.17E+01 5.37E+02 3.56E+00 1.82E+00 2.70E+02 0.0026 0.0077 0.0001 0.0001 0.0017 0.0122 S

A96 399 2.85E+01 3.67E+02 2.43E+00 1.24E+00 1.84E+02 0.0017 0.0053 0.0001 0.0000 0.0012 0.0083 S

A97 186 1.33E+01 1.71E+02 1.13E+00 5.79E-01 8.58E+01 0.0008 0.0025 0.0000 0.0000 0.0005 0.0039 S

A98 301 2.15E+01 2.77E+02 1.83E+00 9.39E-01 1.39E+02 0.0013 0.0040 0.0001 0.0000 0.0009 0.0063 S

A99 150 1.07E+01 1.38E+02 9.12E-01 4.67E-01 6.91E+01 0.0007 0.0020 0.0000 0.0000 0.0004 0.0031 S

B01 155 1.11E+01 1.43E+02 9.45E-01 4.84E-01 7.16E+01 0.0007 0.0021 0.0000 0.0000 0.0005 0.0032 S

B02 364 2.60E+01 3.35E+02 2.22E+00 1.14E+00 1.68E+02 0.0016 0.0048 0.0001 0.0000 0.0011 0.0076 S

B03 321 2.29E+01 2.95E+02 1.96E+00 1.00E+00 1.48E+02 0.0014 0.0043 0.0001 0.0000 0.0009 0.0067 S

B04 56 3.99E+00 5.14E+01 3.41E-01 1.74E-01 2.58E+01 0.0002 0.0007 0.0000 0.0000 0.0002 0.0012 S

B05 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B06 171 1.22E+01 1.58E+02 1.04E+00 5.34E-01 7.91E+01 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 S

B07 31 2.19E+00 2.82E+01 1.87E-01 9.56E-02 1.42E+01 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 S

B08 527 3.76E+01 4.84E+02 3.21E+00 1.64E+00 2.43E+02 0.0023 0.0070 0.0001 0.0001 0.0015 0.0110 S

B09 128 9.15E+00 1.18E+02 7.80E-01 3.99E-01 5.91E+01 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 S

B10 180 1.29E+01 1.66E+02 1.10E+00 5.62E-01 8.33E+01 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038 S

B11 146 1.04E+01 1.34E+02 8.90E-01 4.55E-01 6.74E+01 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030

31 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

B12 258 1.84E+01 2.37E+02 1.57E+00 8.04E-01 1.19E+02 0.0011 0.0034 0.0000 0.0000 0.0008 0.0054 S

B13 63 4.51E+00 5.81E+01 3.84E-01 1.97E-01 2.91E+01 0.0003 0.0008 0.0000 0.0000 0.0002 0.0013 S

B14 269 1.92E+01 2.47E+02 1.64E+00 8.38E-01 1.24E+02 0.0012 0.0036 0.0000 0.0000 0.0008 0.0056 S

B15 90 6.44E+00 8.29E+01 5.49E-01 2.81E-01 4.16E+01 0.0004 0.0012 0.0000 0.0000 0.0003 0.0019 S

B16 175 1.25E+01 1.61E+02 1.07E+00 5.45E-01 8.08E+01 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 S

B17 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B18 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B19 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B20 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B21 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B22 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B23 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B24 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B25 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B26 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B27 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B28 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B29 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B30 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B31 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B32 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B33 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B34 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B35 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B36 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

32 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

B37 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B38 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B39 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B40 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B41 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B42 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B43 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B44 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B45 7

5.15E-01 6.63E+00 4.39E-02 2.25E-02 3.33E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 S

B46 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B47 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B48 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B49 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B50 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B51 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B52 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B53 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B54 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B55 5

3.87E-01 4.98E+00 3.30E-02 1.69E-02 2.50E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0001 S

B56 52 3.74E+00 4.81E+01 3.19E-01 1.63E-01 2.41E+01 0.0002 0.0007 0.0000 0.0000 0.0002 0.0011 S

B57 296 2.11E+01 2.72E+02 1.80E+00 9.22E-01 1.37E+02 0.0013 0.0039 0.0001 0.0000 0.0009 0.0062 S

B58 60 4.25E+00 5.47E+01 3.62E-01 1.86E-01 2.75E+01 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 S

B59 135 9.66E+00 1.24E+02 8.24E-01 4.22E-01 6.25E+01 0.0006 0.0018 0.0000 0.0000 0.0004 0.0028 S

B60 32 2.32E+00 2.99E+01 1.98E-01 1.01E-01 1.50E+01 0.0001 0.0004 0.0000 0.0000 0.0001 0.0007 S

B61 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

33 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

B62 47 3.35E+00 4.31E+01 2.86E-01 1.46E-01 2.16E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0010 S

B63 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B64 32 2.32E+00 2.99E+01 1.98E-01 1.01E-01 1.50E+01 0.0001 0.0004 0.0000 0.0000 0.0001 0.0007 S

B65 36 2.58E+00 3.32E+01 2.20E-01 1.12E-01 1.67E+01 0.0002 0.0005 0.0000 0.0000 0.0001 0.0008 S

B66 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B68 61 4.38E+00 5.64E+01 3.73E-01 1.91E-01 2.83E+01 0.0003 0.0008 0.0000 0.0000 0.0002 0.0013 S

B69 56 3.99E+00 5.14E+01 3.41E-01 1.74E-01 2.58E+01 0.0002 0.0007 0.0000 0.0000 0.0002 0.0012 S

B67 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B70 45 3.22E+00 4.15E+01 2.75E-01 1.41E-01 2.08E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 S

B71 85 6.06E+00 7.80E+01 5.16E-01 2.64E-01 3.91E+01 0.0004 0.0011 0.0000 0.0000 0.0002 0.0018 S

B72 85 6.06E+00 7.80E+01 5.16E-01 2.64E-01 3.91E+01 0.0004 0.0011 0.0000 0.0000 0.0002 0.0018 S

B73 121 8.63E+00 1.11E+02 7.36E-01 3.77E-01 5.58E+01 0.0005 0.0016 0.0000 0.0000 0.0004 0.0025 S

B74 36 2.58E+00 3.32E+01 2.20E-01 1.12E-01 1.67E+01 0.0002 0.0005 0.0000 0.0000 0.0001 0.0008 S

B75 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B76 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B77 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B78 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B79 14 1.03E+00 1.33E+01 8.79E-02 4.50E-02 6.66E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003 S

B80 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B81 43 3.09E+00 3.98E+01 2.64E-01 1.35E-01 2.00E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 S

B82 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B83 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B84 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B85 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B86 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

34 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

B87 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B88 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B89 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B90 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B91 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B92 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B93 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B94 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B95 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B96 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B97 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B98 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

B99 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C01 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C03 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C04 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C05 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C06 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C07 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C08 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C09 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C10 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C11 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C12 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

35 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

C13 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C14 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C15 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C16 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C17 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C18 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C19 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C20 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C21 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C22 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C23 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C24 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C25 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C26 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C27 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C28 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C29 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C30 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C31 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C32 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C33 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C34 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C35 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C36 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C37 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

36 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

C38 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C39 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C40 112 7.99E+00 1.03E+02 6.81E-01 3.49E-01 5.16E+01 0.0005 0.0015 0.0000 0.0000 0.0003 0.0023 S

C41 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C42 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C43 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C44 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C45 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C46 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C47 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C48 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C49 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C50 58 4.12E+00 5.31E+01 3.52E-01 1.80E-01 2.66E+01 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 S

C51 36 2.58E+00 3.32E+01 2.20E-01 1.12E-01 1.67E+01 0.0002 0.0005 0.0000 0.0000 0.0001 0.0008 S

C52 152 1.08E+01 1.39E+02 9.23E-01 4.72E-01 6.99E+01 0.0007 0.0020 0.0000 0.0000 0.0004 0.0032 S

C53 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C54 43 3.09E+00 3.98E+01 2.64E-01 1.35E-01 2.00E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 S

C55 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C56 47 3.35E+00 4.31E+01 2.86E-01 1.46E-01 2.16E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0010 S

C57 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C58 63 4.51E+00 5.81E+01 3.84E-01 1.97E-01 2.91E+01 0.0003 0.0008 0.0000 0.0000 0.0002 0.0013 S

C59 240 1.71E+01 2.21E+02 1.46E+00 7.48E-01 1.11E+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0050 S

C60 81 5.80E+00 7.46E+01 4.94E-01 2.53E-01 3.75E+01 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017 S

C61 211 1.51E+01 1.94E+02 1.29E+00 6.58E-01 9.74E+01 0.0009 0.0028 0.0000 0.0000 0.0006 0.0044 S

C62 83 5.93E+00 7.63E+01 5.05E-01 2.59E-01 3.83E+01 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017

37 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

C63 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C64 137 9.79E+00 1.26E+02 8.35E-01 4.27E-01 6.33E+01 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 S

C65 31 2.19E+00 2.82E+01 1.87E-01 9.56E-02 1.42E+01 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 S

C66 96 6.83E+00 8.79E+01 5.82E-01 2.98E-01 4.41E+01 0.0004 0.0013 0.0000 0.0000 0.0003 0.0020 S

C67 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C68 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C69 31 2.19E+00 2.82E+01 1.87E-01 9.56E-02 1.42E+01 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 S

C70 101 7.22E+00 9.29E+01 6.15E-01 3.15E-01 4.66E+01 0.0004 0.0013 0.0000 0.0000 0.0003 0.0021 S

C71 229 1.64E+01 2.11E+02 1.40E+00 7.14E-01 1.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048 S

C72 249 1.78E+01 2.29E+02 1.52E+00 7.76E-01 1.15E+02 0.0011 0.0033 0.0000 0.0000 0.0007 0.0052 S

C73 440 3.14E+01 4.05E+02 2.68E+00 1.37E+00 2.03E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0092 S

C74 352 2.51E+01 3.23E+02 2.14E+00 1.10E+00 1.62E+02 0.0015 0.0047 0.0001 0.0000 0.0010 0.0073 S

C75 438 3.13E+01 4.03E+02 2.67E+00 1.37E+00 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091 S

C76 135 9.66E+00 1.24E+02 8.24E-01 4.22E-01 6.25E+01 0.0006 0.0018 0.0000 0.0000 0.0004 0.0028 S

C77 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C78 5

3.87E-01 4.98E+00 3.30E-02 1.69E-02 2.50E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0001 S

C79 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C80 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C81 139 9.92E+00 1.28E+02 8.46E-01 4.33E-01 6.41E+01 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 S

C82 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C83 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C84 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C85 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C86 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C87 49 3.48E+00 4.48E+01 2.97E-01 1.52E-01 2.25E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0010

38 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

C88 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C89 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C90 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C91 134 9.54E+00 1.23E+02 8.13E-01 4.16E-01 6.16E+01 0.0006 0.0018 0.0000 0.0000 0.0004 0.0028 S

C92 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C93 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C94 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C95 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C96 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C97 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C98 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

C99 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

D01 11 7.73E-01 9.95E+00 6.59E-02 3.37E-02 5.00E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 S

D02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

D03 229 1.64E+01 2.11E+02 1.40E+00 7.14E-01 1.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048 S

D04 65 4.64E+00 5.97E+01 3.95E-01 2.02E-01 3.00E+01 0.0003 0.0009 0.0000 0.0000 0.0002 0.0014 S

D05 137 9.79E+00 1.26E+02 8.35E-01 4.27E-01 6.33E+01 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 S

D06 119 8.50E+00 1.09E+02 7.25E-01 3.71E-01 5.50E+01 0.0005 0.0016 0.0000 0.0000 0.0003 0.0025 S

D07 204 1.46E+01 1.87E+02 1.24E+00 6.35E-01 9.41E+01 0.0009 0.0027 0.0000 0.0000 0.0006 0.0042 S

D08 285 2.04E+01 2.62E+02 1.74E+00 8.88E-01 1.32E+02 0.0012 0.0038 0.0000 0.0000 0.0008 0.0059 S

D09 382 2.73E+01 3.52E+02 2.33E+00 1.19E+00 1.77E+02 0.0017 0.0051 0.0001 0.0000 0.0011 0.0080 S

D10 350 2.50E+01 3.22E+02 2.13E+00 1.09E+00 1.62E+02 0.0015 0.0046 0.0001 0.0000 0.0010 0.0073 S

D11 482 3.44E+01 4.43E+02 2.93E+00 1.50E+00 2.22E+02 0.0021 0.0064 0.0001 0.0000 0.0014 0.0100 S

D12 343 2.45E+01 3.15E+02 2.09E+00 1.07E+00 1.58E+02 0.0015 0.0045 0.0001 0.0000 0.0010 0.0071 S

D13 388 2.77E+01 3.57E+02 2.36E+00 1.21E+00 1.79E+02 0.0017 0.0051 0.0001 0.0000 0.0011 0.0081

39 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

D14 417 2.98E+01 3.83E+02 2.54E+00 1.30E+00 1.92E+02 0.0018 0.0055 0.0001 0.0000 0.0012 0.0087 S

D15 660 4.72E+01 6.07E+02 4.02E+00 2.06E+00 3.05E+02 0.0029 0.0087 0.0001 0.0001 0.0019 0.0137 S

D16 615 4.39E+01 5.66E+02 3.75E+00 1.92E+00 2.84E+02 0.0027 0.0082 0.0001 0.0001 0.0018 0.0128 S

D17 523 3.74E+01 4.81E+02 3.19E+00 1.63E+00 2.41E+02 0.0023 0.0069 0.0001 0.0000 0.0015 0.0109 S

D18 446 3.18E+01 4.10E+02 2.71E+00 1.39E+00 2.06E+02 0.0020 0.0059 0.0001 0.0000 0.0013 0.0093 S

D19 604 4.32E+01 5.56E+02 3.68E+00 1.88E+00 2.79E+02 0.0026 0.0080 0.0001 0.0001 0.0018 0.0126 S

D20 590 4.21E+01 5.42E+02 3.59E+00 1.84E+00 2.72E+02 0.0026 0.0078 0.0001 0.0001 0.0017 0.0123 S

D21 711 5.08E+01 6.54E+02 4.33E+00 2.22E+00 3.28E+02 0.0031 0.0094 0.0001 0.0001 0.0021 0.0148 S

D22 722 5.15E+01 6.63E+02 4.39E+00 2.25E+00 3.33E+02 0.0032 0.0096 0.0001 0.0001 0.0021 0.0150 S

D23 1046 7.47E+01 9.62E+02 6.37E+00 3.26E+00 4.83E+02 0.0046 0.0139 0.0002 0.0001 0.0031 0.0218 S

D24 933 6.66E+01 8.58E+02 5.68E+00 2.91E+00 4.30E+02 0.0041 0.0124 0.0002 0.0001 0.0027 0.0194 S

D25 814 5.81E+01 7.48E+02 4.95E+00 2.54E+00 3.76E+02 0.0036 0.0108 0.0001 0.0001 0.0024 0.0169 S

D26 893 6.38E+01 8.21E+02 5.44E+00 2.78E+00 4.12E+02 0.0039 0.0118 0.0002 0.0001 0.0026 0.0186 S

D27 585 4.17E+01 5.37E+02 3.56E+00 1.82E+00 2.70E+02 0.0026 0.0077 0.0001 0.0001 0.0017 0.0122 S

D28 673 4.81E+01 6.19E+02 4.10E+00 2.10E+00 3.11E+02 0.0029 0.0089 0.0001 0.0001 0.0020 0.0140 S

D29 610 4.36E+01 5.61E+02 3.71E+00 1.90E+00 2.81E+02 0.0027 0.0081 0.0001 0.0001 0.0018 0.0127 S

D30 742 5.30E+01 6.82E+02 4.51E+00 2.31E+00 3.42E+02 0.0032 0.0098 0.0001 0.0001 0.0022 0.0154 S

D31 613 4.38E+01 5.64E+02 3.73E+00 1.91E+00 2.83E+02 0.0027 0.0081 0.0001 0.0001 0.0018 0.0128 S

D32 1037 7.41E+01 9.54E+02 6.32E+00 3.23E+00 4.79E+02 0.0045 0.0137 0.0002 0.0001 0.0030 0.0216 S

D33 814 5.81E+01 7.48E+02 4.95E+00 2.54E+00 3.76E+02 0.0036 0.0108 0.0001 0.0001 0.0024 0.0169 S

D34 852 6.08E+01 7.83E+02 5.18E+00 2.65E+00 3.93E+02 0.0037 0.0113 0.0001 0.0001 0.0025 0.0177 S

D35 567 4.05E+01 5.21E+02 3.45E+00 1.77E+00 2.61E+02 0.0025 0.0075 0.0001 0.0001 0.0017 0.0118 S

D36 806 5.76E+01 7.41E+02 4.91E+00 2.51E+00 3.72E+02 0.0035 0.0107 0.0001 0.0001 0.0024 0.0168 S

D37 926 6.61E+01 8.51E+02 5.64E+00 2.88E+00 4.27E+02 0.0041 0.0123 0.0002 0.0001 0.0027 0.0193 S

D38 700 5.00E+01 6.44E+02 4.26E+00 2.18E+00 3.23E+02 0.0031 0.0093 0.0001 0.0001 0.0020 0.0146

40 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

D39 1030 7.36E+01 9.47E+02 6.27E+00 3.21E+00 4.75E+02 0.0045 0.0136 0.0002 0.0001 0.0030 0.0214 S

D40 817 5.84E+01 7.51E+02 4.98E+00 2.55E+00 3.77E+02 0.0036 0.0108 0.0001 0.0001 0.0024 0.0170 S

D41 678 4.84E+01 6.24E+02 4.13E+00 2.11E+00 3.13E+02 0.0030 0.0090 0.0001 0.0001 0.0020 0.0141 S

D42 318 2.27E+01 2.92E+02 1.93E+00 9.90E-01 1.47E+02 0.0014 0.0042 0.0001 0.0000 0.0009 0.0066 S

D43 512 3.66E+01 4.71E+02 3.12E+00 1.60E+00 2.36E+02 0.0022 0.0068 0.0001 0.0000 0.0015 0.0107 S

D44 494 3.53E+01 4.54E+02 3.01E+00 1.54E+00 2.28E+02 0.0022 0.0065 0.0001 0.0000 0.0014 0.0103 S

D45 561 4.01E+01 5.16E+02 3.42E+00 1.75E+00 2.59E+02 0.0025 0.0074 0.0001 0.0001 0.0016 0.0117 S

D46 437 3.12E+01 4.01E+02 2.66E+00 1.36E+00 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091 S

D47 543 3.88E+01 4.99E+02 3.31E+00 1.69E+00 2.51E+02 0.0024 0.0072 0.0001 0.0001 0.0016 0.0113 S

D48 350 2.50E+01 3.22E+02 2.13E+00 1.09E+00 1.62E+02 0.0015 0.0046 0.0001 0.0000 0.0010 0.0073 S

D49 290 2.07E+01 2.67E+02 1.77E+00 9.05E-01 1.34E+02 0.0013 0.0038 0.0001 0.0000 0.0008 0.0060 S

D50 74 5.28E+00 6.80E+01 4.50E-01 2.31E-01 3.41E+01 0.0003 0.0010 0.0000 0.0000 0.0002 0.0015 S

D51 200 1.43E+01 1.84E+02 1.22E+00 6.24E-01 9.24E+01 0.0009 0.0027 0.0000 0.0000 0.0006 0.0042 S

D52 143 1.02E+01 1.31E+02 8.68E-01 4.44E-01 6.58E+01 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 S

D53 119 8.50E+00 1.09E+02 7.25E-01 3.71E-01 5.50E+01 0.0005 0.0016 0.0000 0.0000 0.0003 0.0025 S

D54 189 1.35E+01 1.74E+02 1.15E+00 5.90E-01 8.74E+01 0.0008 0.0025 0.0000 0.0000 0.0006 0.0039 S

D55 146 1.04E+01 1.34E+02 8.90E-01 4.55E-01 6.74E+01 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 S

D56 236 1.69E+01 2.17E+02 1.44E+00 7.37E-01 1.09E+02 0.0010 0.0031 0.0000 0.0000 0.0007 0.0049 S

D57 184 1.31E+01 1.69E+02 1.12E+00 5.73E-01 8.49E+01 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038 S

D58 31 2.19E+00 2.82E+01 1.87E-01 9.56E-02 1.42E+01 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 S

D59 16 1.16E+00 1.49E+01 9.89E-02 5.06E-02 7.49E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003 S

D60 130 9.28E+00 1.19E+02 7.91E-01 4.05E-01 6.00E+01 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 S

D61 92 6.57E+00 8.46E+01 5.60E-01 2.87E-01 4.25E+01 0.0004 0.0012 0.0000 0.0000 0.0003 0.0019 S

D62 83 5.93E+00 7.63E+01 5.05E-01 2.59E-01 3.83E+01 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017 S

D63 161 1.15E+01 1.48E+02 9.78E-01 5.00E-01 7.41E+01 0.0007 0.0021 0.0000 0.0000 0.0005 0.0033

41 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

D64 229 1.64E+01 2.11E+02 1.40E+00 7.14E-01 1.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048 S

D65 240 1.71E+01 2.21E+02 1.46E+00 7.48E-01 1.11E+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0050 S

D66 310 2.22E+01 2.85E+02 1.89E+00 9.67E-01 1.43E+02 0.0014 0.0041 0.0001 0.0000 0.0009 0.0065 S

D67 148 1.06E+01 1.36E+02 9.01E-01 4.61E-01 6.83E+01 0.0006 0.0020 0.0000 0.0000 0.0004 0.0031 S

D68 303 2.16E+01 2.79E+02 1.85E+00 9.45E-01 1.40E+02 0.0013 0.0040 0.0001 0.0000 0.0009 0.0063 S

D69 85 6.06E+00 7.80E+01 5.16E-01 2.64E-01 3.91E+01 0.0004 0.0011 0.0000 0.0000 0.0002 0.0018 S

D70 242 1.73E+01 2.22E+02 1.47E+00 7.53E-01 1.12E+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0050 S

D71 81 5.80E+00 7.46E+01 4.94E-01 2.53E-01 3.75E+01 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017 S

D72 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

D73 312 2.23E+01 2.87E+02 1.90E+00 9.73E-01 1.44E+02 0.0014 0.0041 0.0001 0.0000 0.0009 0.0065 S

D74 180 1.29E+01 1.66E+02 1.10E+00 5.62E-01 8.33E+01 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038 S

D75 197 1.40E+01 1.81E+02 1.20E+00 6.13E-01 9.08E+01 0.0009 0.0026 0.0000 0.0000 0.0006 0.0041 S

D76 43 3.09E+00 3.98E+01 2.64E-01 1.35E-01 2.00E+01 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 S

D77 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

D78 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

D79 128 9.15E+00 1.18E+02 7.80E-01 3.99E-01 5.91E+01 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 S

D80 390 2.78E+01 3.58E+02 2.37E+00 1.21E+00 1.80E+02 0.0017 0.0052 0.0001 0.0000 0.0011 0.0081 S

D81 547 3.90E+01 5.03E+02 3.33E+00 1.70E+00 2.52E+02 0.0024 0.0072 0.0001 0.0001 0.0016 0.0114 S

D82 493 3.52E+01 4.53E+02 3.00E+00 1.53E+00 2.27E+02 0.0022 0.0065 0.0001 0.0000 0.0014 0.0103 S

D83 622 4.45E+01 5.72E+02 3.79E+00 1.94E+00 2.87E+02 0.0027 0.0082 0.0001 0.0001 0.0018 0.0130 S

D84 622 4.45E+01 5.72E+02 3.79E+00 1.94E+00 2.87E+02 0.0027 0.0082 0.0001 0.0001 0.0018 0.0130 S

D85 474 3.39E+01 4.36E+02 2.89E+00 1.48E+00 2.19E+02 0.0021 0.0063 0.0001 0.0000 0.0014 0.0099 S

D86 529 3.78E+01 4.86E+02 3.22E+00 1.65E+00 2.44E+02 0.0023 0.0070 0.0001 0.0001 0.0015 0.0110 S

D87 413 2.95E+01 3.80E+02 2.52E+00 1.29E+00 1.91E+02 0.0018 0.0055 0.0001 0.0000 0.0012 0.0086 S

D88 298 2.13E+01 2.74E+02 1.81E+00 9.28E-01 1.37E+02 0.0013 0.0039 0.0001 0.0000 0.0009 0.0062

42 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

D89 772 5.52E+01 7.10E+02 4.70E+00 2.41E+00 3.56E+02 0.0034 0.0102 0.0001 0.0001 0.0023 0.0161 S

D90 734 5.24E+01 6.75E+02 4.47E+00 2.29E+00 3.39E+02 0.0032 0.0097 0.0001 0.0001 0.0021 0.0153 S

D91 873 6.24E+01 8.03E+02 5.32E+00 2.72E+00 4.03E+02 0.0038 0.0116 0.0002 0.0001 0.0026 0.0182 S

D92 898 6.42E+01 8.26E+02 5.47E+00 2.80E+00 4.15E+02 0.0039 0.0119 0.0002 0.0001 0.0026 0.0187 S

D93 761 5.44E+01 7.00E+02 4.64E+00 2.37E+00 3.51E+02 0.0033 0.0101 0.0001 0.0001 0.0022 0.0159 S

D94 810 5.79E+01 7.45E+02 4.93E+00 2.52E+00 3.74E+02 0.0035 0.0107 0.0001 0.0001 0.0024 0.0169 S

D95 579 4.14E+01 5.32E+02 3.53E+00 1.80E+00 2.67E+02 0.0025 0.0077 0.0001 0.0001 0.0017 0.0121 S

D96 244 1.74E+01 2.24E+02 1.48E+00 7.59E-01 1.12E+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0051 S

D97 648 4.63E+01 5.95E+02 3.94E+00 2.02E+00 2.99E+02 0.0028 0.0086 0.0001 0.0001 0.0019 0.0135 S

D98 628 4.48E+01 5.77E+02 3.82E+00 1.96E+00 2.90E+02 0.0028 0.0083 0.0001 0.0001 0.0018 0.0131 S

D99 74 5.28E+00 6.80E+01 4.50E-01 2.31E-01 3.41E+01 0.0003 0.0010 0.0000 0.0000 0.0002 0.0015 S

E01 60 4.25E+00 5.47E+01 3.62E-01 1.86E-01 2.75E+01 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 S

E02 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

E03 137 9.79E+00 1.26E+02 8.35E-01 4.27E-01 6.33E+01 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 S

E04 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

E05 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

E06 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

E07 112 7.99E+00 1.03E+02 6.81E-01 3.49E-01 5.16E+01 0.0005 0.0015 0.0000 0.0000 0.0003 0.0023 S

E08 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 S

E09 363 2.59E+01 3.33E+02 2.21E+00 1.13E+00 1.67E+02 0.0016 0.0048 0.0001 0.0000 0.0011 0.0075 S

E10 364 2.60E+01 3.35E+02 2.22E+00 1.14E+00 1.68E+02 0.0016 0.0048 0.0001 0.0000 0.0011 0.0076 S

E11 438 3.13E+01 4.03E+02 2.67E+00 1.37E+00 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091 S

E12 920 6.57E+01 8.46E+02 5.60E+00 2.87E+00 4.25E+02 0.0040 0.0122 0.0002 0.0001 0.0027 0.0192 S

E13 1019 7.28E+01 9.37E+02 6.21E+00 3.18E+00 4.70E+02 0.0045 0.0135 0.0002 0.0001 0.0030 0.0212 S

E14 1102 7.87E+01 1.01E+03 6.71E+00 3.44E+00 5.09E+02 0.0048 0.0146 0.0002 0.0001 0.0032 0.0229

43 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 S

E15 1131 8.08E+01 1.04E+03 6.89E+00 3.53E+00 5.22E+02 0.0050 0.0150 0.0002 0.0001 0.0033 0.0236 S

E16 1155 8.25E+01 1.06E+03 7.03E+00 3.60E+00 5.33E+02 0.0051 0.0153 0.0002 0.0001 0.0034 0.0240 S

E17 2324 1.66E+02 2.14E+03 1.41E+01 7.24E+00 1.07E+03 0.0102 0.0308 0.0004 0.0002 0.0068 0.0484 S

E18 4014 2.87E+02 3.69E+03 2.44E+01 1.25E+01 1.85E+03 0.0176 0.0532 0.0007 0.0004 0.0117 0.0836 S

E19 4687 3.35E+02 4.31E+03 2.85E+01 1.46E+01 2.16E+03 0.0205 0.0621 0.0008 0.0004 0.0137 0.0976 S

E20 4738 3.38E+02 4.36E+03 2.88E+01 1.48E+01 2.19E+03 0.0208 0.0628 0.0008 0.0005 0.0138 0.0986 S

E21 4561 3.26E+02 4.19E+03 2.78E+01 1.42E+01 2.10E+03 0.0200 0.0604 0.0008 0.0004 0.0133 0.0950 S

E22 4458 3.18E+02 4.10E+03 2.71E+01 1.39E+01 2.06E+03 0.0195 0.0591 0.0008 0.0004 0.0130 0.0928 S

E23 4624 3.30E+02 4.25E+03 2.82E+01 1.44E+01 2.13E+03 0.0203 0.0613 0.0008 0.0004 0.0135 0.0963 S

E24 4765 3.40E+02 4.38E+03 2.90E+01 1.48E+01 2.20E+03 0.0209 0.0631 0.0008 0.0005 0.0139 0.0992 S

E25 4725 3.37E+02 4.34E+03 2.88E+01 1.47E+01 2.18E+03 0.0207 0.0626 0.0008 0.0005 0.0138 0.0984 Q

A05QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

A12QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

A34QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

A40QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

A47QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

A66QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

A76QC 122 8.72E+00 1.12E+02 7.43E-01 3.80E-01 5.63E+01 0.0005 0.0016 0.0000 0.0000 0.0004 0.0025 Q

A95QC 295 2.11E+01 2.71E+02 1.80E+00 9.20E-01 1.36E+02 0.0013 0.0039 0.0001 0.0000 0.0009 0.0061 Q

A97QC 246 1.76E+01 2.26E+02 1.50E+00 7.67E-01 1.14E+02 0.0011 0.0033 0.0000 0.0000 0.0007 0.0051 Q

B20QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

C06QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

C24QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

C42QC 142 1.01E+01 1.31E+02 8.65E-01 4.43E-01 6.56E+01 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 Q

C56QC 15 1.04E+00 1.34E+01 8.87E-02 4.54E-02 6.73E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003

44 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Measurement Population Measurement ID Gamma Result Activity1 (dpm/100 cm2)

Fraction of OpDCGL Measurement OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Q

C67QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

C85QC 0

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Q

C89QC 27 1.95E+00 2.51E+01 1.66E-01 8.52E-02 1.26E+01 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 Q

C90QC 128 9.11E+00 1.17E+02 7.77E-01 3.97E-01 5.89E+01 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 Q

D32QC 802 5.73E+01 7.37E+02 4.88E+00 2.50E+00 3.70E+02 0.0035 0.0106 0.0001 0.0001 0.0023 0.0167 Q

D79QC 157 1.12E+01 1.44E+02 9.54E-01 4.88E-01 7.23E+01 0.0007 0.0021 0.0000 0.0000 0.0005 0.0033 Q

E03QC 51 3.64E+00 4.69E+01 3.11E-01 1.59E-01 2.35E+01 0.0002 0.0007 0.0000 0.0000 0.0001 0.0011 Q

E14QC 191 1.37E+01 1.76E+02 1.16E+00 5.96E-01 8.83E+01 0.0008 0.0025 0.0000 0.0000 0.0006 0.0040 Q

E19QC 2434 1.74E+02 2.24E+03 1.48E+01 7.59E+00 1.12E+03 0.0107 0.0322 0.0004 0.0002 0.0071 0.0507 Q

E20QC 3194 2.28E+02 2.94E+03 1.94E+01 9.95E+00 1.47E+03 0.0140 0.0423 0.0006 0.0003 0.0093 0.0665 Q

E24QC 4407 3.15E+02 4.05E+03 2.68E+01 1.37E+01 2.03E+03 0.0193 0.0584 0.0008 0.0004 0.0129 0.0918 J

K01Biased 5869 4.19E+02 5.40E+03 3.57E+01 1.83E+01 2.71E+03 0.0257 0.0777 0.0010 0.0006 0.0171 0.1222 J

K02Biased 6056 4.33E+02 5.57E+03 3.69E+01 1.89E+01 2.80E+03 0.0265 0.0802 0.0011 0.0006 0.0177 0.1261

45 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 ATTACHMENT 3 SIGN TEST

46 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 Table 16 Survey Unit S1-011-102 Sign Test SOF 1-Ws Sign (Ws) 1 0.0125 0.99

+1 2

0.0000 1.00

+1 3

0.0002 1.00

+1 4

0.0000 1.00

+1 5

0.0000 1.00

+1 6

0.0000 1.00

+1 7

0.0000 1.00

+1 8

0.0000 1.00

+1 9

0.0000 1.00

+1 10 0.0000 1.00

+1 11 0.0000 1.00

+1 12 0.0000 1.00

+1 13 0.0000 1.00

+1 14 0.0000 1.00

+1 15 0.0000 1.00

+1 16 0.0000 1.00

+1 17 0.0094 0.99

+1 18 0.0040 1.00

+1 19 0.0066 0.99

+1 20 0.0144 0.99

+1 21 0.0036 1.00

+1 22 0.0044 1.00

+1 23 0.0031 1.00

+1 24 0.0014 1.00

+1 25 0.0000 1.00

+1 26 0.0000 1.00

+1 27 0.0000 1.00

+1 28 0.0000 1.00

+1 29 0.0000 1.00

+1 30 0.0000 1.00

+1 31 0.0009 1.00

+1 32 0.0000 1.00

+1 33 0.0000 1.00

+1 34 0.0000 1.00

+1 35 0.0000 1.00

+1 36 0.0000 1.00

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 47 SOF 1-Ws Sign (Ws) 37 0.0000 1.00

+1 38 0.0000 1.00

+1 39 0.0000 1.00

+1 40 0.0000 1.00

+1 41 0.0000 1.00

+1 42 0.0000 1.00

+1 43 0.0000 1.00

+1 44 0.0000 1.00

+1 45 0.0000 1.00

+1 46 0.0000 1.00

+1 47 0.0000 1.00

+1 48 0.0000 1.00

+1 49 0.0038 1.00

+1 50 0.0000 1.00

+1 51 0.0012 1.00

+1 52 0.0000 1.00

+1 53 0.0000 1.00

+1 54 0.0004 1.00

+1 55 0.0002 1.00

+1 56 0.0015 1.00

+1 57 0.0030 1.00

+1 58 0.0000 1.00

+1 59 0.0003 1.00

+1 60 0.0000 1.00

+1 61 0.0088 0.99

+1 62 0.0014 1.00

+1 63 0.0045 1.00

+1 64 0.0036 1.00

+1 65 0.0140 0.99

+1 66 0.0148 0.99

+1 67 0.0183 0.98

+1 68 0.0136 0.99

+1 69 0.0107 0.99

+1 70 0.0117 0.99

+1 71 0.0101 0.99

+1 72 0.0114 0.99

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 48 SOF 1-Ws Sign (Ws) 73 0.0092 0.99

+1 74 0.0048 1.00

+1 75 0.0066 0.99

+1 76 0.0044 1.00

+1 77 0.0026 1.00

+1 78 0.0045 1.00

+1 79 0.0027 1.00

+1 80 0.0063 0.99

+1 81 0.0009 1.00

+1 82 0.0000 1.00

+1 83 0.0000 1.00

+1 84 0.0000 1.00

+1 85 0.0845 0.92

+1 86 0.1131 0.89

+1 87 0.1113 0.89

+1 88 0.0956 0.90

+1 89 0.0198 0.98

+1 90 0.0082 0.99

+1 91 0.0000 1.00

+1 92 0.0000 1.00

+1 93 0.0000 1.00

+1 94 0.0000 1.00

+1 95 0.0000 1.00

+1 96 0.0000 1.00

+1 97 0.0000 1.00

+1 98 0.0000 1.00

+1 99 0.0000 1.00

+1 100 0.0000 1.00

+1 101 0.0000 1.00

+1 102 0.0000 1.00

+1 103 0.0000 1.00

+1 104 0.0000 1.00

+1 105 0.0000 1.00

+1 106 0.0000 1.00

+1 107 0.0000 1.00

+1 108 0.0000 1.00

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 49 SOF 1-Ws Sign (Ws) 109 0.0000 1.00

+1 110 0.0000 1.00

+1 111 0.0000 1.00

+1 112 0.0000 1.00

+1 113 0.0000 1.00

+1 114 0.0000 1.00

+1 115 0.0000 1.00

+1 116 0.0000 1.00

+1 117 0.0000 1.00

+1 118 0.0000 1.00

+1 119 0.0000 1.00

+1 120 0.0000 1.00

+1 121 0.0000 1.00

+1 122 0.0000 1.00

+1 123 0.0000 1.00

+1 124 0.0000 1.00

+1 125 0.0000 1.00

+1 126 0.0000 1.00

+1 127 0.0000 1.00

+1 128 0.0000 1.00

+1 129 0.0000 1.00

+1 130 0.0000 1.00

+1 131 0.0000 1.00

+1 132 0.0000 1.00

+1 133 0.0000 1.00

+1 134 0.0000 1.00

+1 135 0.0000 1.00

+1 136 0.0000 1.00

+1 137 0.0000 1.00

+1 138 0.0000 1.00

+1 139 0.0000 1.00

+1 140 0.0000 1.00

+1 141 0.0000 1.00

+1 142 0.0000 1.00

+1 143 0.0000 1.00

+1 144 0.0000 1.00

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 50 SOF 1-Ws Sign (Ws) 145 0.0000 1.00

+1 146 0.0000 1.00

+1 147 0.0000 1.00

+1 148 0.0000 1.00

+1 149 0.0000 1.00

+1 150 0.0000 1.00

+1 151 0.0000 1.00

+1 152 0.0000 1.00

+1 153 0.0000 1.00

+1 154 0.0015 1.00

+1 155 0.0033 1.00

+1 156 0.0000 1.00

+1 157 0.0018 1.00

+1 158 0.0000 1.00

+1 159 0.0000 1.00

+1 160 0.0042 1.00

+1 161 0.0124 0.99

+1 162 0.0108 0.99

+1 163 0.0096 0.99

+1 164 0.0122 0.99

+1 165 0.0071 0.99

+1 166 0.0086 0.99

+1 167 0.0110 0.99

+1 168 0.0080 0.99

+1 169 0.0068 0.99

+1 170 0.0089 0.99

+1 171 0.0075 0.99

+1 172 0.0036 1.00

+1 173 0.0058 0.99

+1 174 0.0091 0.99

+1 175 0.0080 0.99

+1 176 0.0052 0.99

+1 177 0.0112 0.99

+1 178 0.0090 0.99

+1 179 0.0074 0.99

+1 180 0.0101 0.99

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 51 SOF 1-Ws Sign (Ws) 181 0.0052 0.99

+1 182 0.0045 1.00

+1 183 0.0058 0.99

+1 184 0.0122 0.99

+1 185 0.0083 0.99

+1 186 0.0039 1.00

+1 187 0.0063 0.99

+1 188 0.0031 1.00

+1 189 0.0032 1.00

+1 190 0.0076 0.99

+1 191 0.0067 0.99

+1 192 0.0012 1.00

+1 193 0.0000 1.00

+1 194 0.0036 1.00

+1 195 0.0006 1.00

+1 196 0.0110 0.99

+1 197 0.0027 1.00

+1 198 0.0038 1.00

+1 199 0.0030 1.00

+1 200 0.0054 0.99

+1 201 0.0013 1.00

+1 202 0.0056 0.99

+1 203 0.0019 1.00

+1 204 0.0036 1.00

+1 205 0.0000 1.00

+1 206 0.0000 1.00

+1 207 0.0000 1.00

+1 208 0.0000 1.00

+1 209 0.0000 1.00

+1 210 0.0000 1.00

+1 211 0.0000 1.00

+1 212 0.0000 1.00

+1 213 0.0000 1.00

+1 214 0.0000 1.00

+1 215 0.0000 1.00

+1 216 0.0000 1.00

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 52 SOF 1-Ws Sign (Ws) 217 0.0000 1.00

+1 218 0.0000 1.00

+1 219 0.0000 1.00

+1 220 0.0000 1.00

+1 221 0.0000 1.00

+1 222 0.0000 1.00

+1 223 0.0000 1.00

+1 224 0.0000 1.00

+1 225 0.0000 1.00

+1 226 0.0000 1.00

+1 227 0.0000 1.00

+1 228 0.0000 1.00

+1 229 0.0000 1.00

+1 230 0.0000 1.00

+1 231 0.0000 1.00

+1 232 0.0000 1.00

+1 233 0.0002 1.00

+1 234 0.0000 1.00

+1 235 0.0000 1.00

+1 236 0.0000 1.00

+1 237 0.0000 1.00

+1 238 0.0000 1.00

+1 239 0.0000 1.00

+1 240 0.0000 1.00

+1 241 0.0000 1.00

+1 242 0.0000 1.00

+1 243 0.0001 1.00

+1 244 0.0011 1.00

+1 245 0.0062 0.99

+1 246 0.0012 1.00

+1 247 0.0028 1.00

+1 248 0.0007 1.00

+1 249 0.0000 1.00

+1 250 0.0010 1.00

+1 251 0.0000 1.00

+1 252 0.0007 1.00

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 53 SOF 1-Ws Sign (Ws) 253 0.0008 1.00

+1 254 0.0000 1.00

+1 255 0.0013 1.00

+1 256 0.0012 1.00

+1 257 0.0000 1.00

+1 258 0.0009 1.00

+1 259 0.0018 1.00

+1 260 0.0018 1.00

+1 261 0.0025 1.00

+1 262 0.0008 1.00

+1 263 0.0000 1.00

+1 264 0.0000 1.00

+1 265 0.0000 1.00

+1 266 0.0000 1.00

+1 267 0.0003 1.00

+1 268 0.0000 1.00

+1 269 0.0009 1.00

+1 270 0.0000 1.00

+1 271 0.0000 1.00

+1 272 0.0000 1.00

+1 273 0.0000 1.00

+1 274 0.0000 1.00

+1 275 0.0000 1.00

+1 276 0.0000 1.00

+1 277 0.0000 1.00

+1 278 0.0000 1.00

+1 279 0.0000 1.00

+1 280 0.0000 1.00

+1 281 0.0000 1.00

+1 282 0.0000 1.00

+1 283 0.0000 1.00

+1 284 0.0000 1.00

+1 285 0.0000 1.00

+1 286 0.0000 1.00

+1 287 0.0000 1.00

+1 288 0.0000 1.00

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 54 SOF 1-Ws Sign (Ws) 289 0.0000 1.00

+1 290 0.0000 1.00

+1 291 0.0000 1.00

+1 292 0.0000 1.00

+1 293 0.0000 1.00

+1 294 0.0000 1.00

+1 295 0.0000 1.00

+1 296 0.0000 1.00

+1 297 0.0000 1.00

+1 298 0.0000 1.00

+1 299 0.0000 1.00

+1 300 0.0000 1.00

+1 301 0.0000 1.00

+1 302 0.0000 1.00

+1 303 0.0000 1.00

+1 304 0.0000 1.00

+1 305 0.0000 1.00

+1 306 0.0000 1.00

+1 307 0.0000 1.00

+1 308 0.0000 1.00

+1 309 0.0000 1.00

+1 310 0.0000 1.00

+1 311 0.0000 1.00

+1 312 0.0000 1.00

+1 313 0.0000 1.00

+1 314 0.0000 1.00

+1 315 0.0000 1.00

+1 316 0.0000 1.00

+1 317 0.0000 1.00

+1 318 0.0000 1.00

+1 319 0.0000 1.00

+1 320 0.0000 1.00

+1 321 0.0000 1.00

+1 322 0.0000 1.00

+1 323 0.0000 1.00

+1 324 0.0000 1.00

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 55 SOF 1-Ws Sign (Ws) 325 0.0000 1.00

+1 326 0.0000 1.00

+1 327 0.0023 1.00

+1 328 0.0000 1.00

+1 329 0.0000 1.00

+1 330 0.0000 1.00

+1 331 0.0000 1.00

+1 332 0.0000 1.00

+1 333 0.0000 1.00

+1 334 0.0000 1.00

+1 335 0.0000 1.00

+1 336 0.0000 1.00

+1 337 0.0012 1.00

+1 338 0.0008 1.00

+1 339 0.0032 1.00

+1 340 0.0000 1.00

+1 341 0.0009 1.00

+1 342 0.0000 1.00

+1 343 0.0010 1.00

+1 344 0.0000 1.00

+1 345 0.0013 1.00

+1 346 0.0050 1.00

+1 347 0.0017 1.00

+1 348 0.0044 1.00

+1 349 0.0017 1.00

+1 350 0.0000 1.00

+1 351 0.0029 1.00

+1 352 0.0006 1.00

+1 353 0.0020 1.00

+1 354 0.0000 1.00

+1 355 0.0000 1.00

+1 356 0.0006 1.00

+1 357 0.0021 1.00

+1 358 0.0048 1.00

+1 359 0.0052 0.99

+1 360 0.0092 0.99

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 56 SOF 1-Ws Sign (Ws) 361 0.0073 0.99

+1 362 0.0091 0.99

+1 363 0.0028 1.00

+1 364 0.0000 1.00

+1 365 0.0001 1.00

+1 366 0.0000 1.00

+1 367 0.0000 1.00

+1 368 0.0029 1.00

+1 369 0.0000 1.00

+1 370 0.0000 1.00

+1 371 0.0000 1.00

+1 372 0.0000 1.00

+1 373 0.0000 1.00

+1 374 0.0010 1.00

+1 375 0.0000 1.00

+1 376 0.0000 1.00

+1 377 0.0000 1.00

+1 378 0.0028 1.00

+1 379 0.0000 1.00

+1 380 0.0000 1.00

+1 381 0.0000 1.00

+1 382 0.0000 1.00

+1 383 0.0000 1.00

+1 384 0.0000 1.00

+1 385 0.0000 1.00

+1 386 0.0000 1.00

+1 387 0.0002 1.00

+1 388 0.0000 1.00

+1 389 0.0048 1.00

+1 390 0.0014 1.00

+1 391 0.0029 1.00

+1 392 0.0025 1.00

+1 393 0.0042 1.00

+1 394 0.0059 0.99

+1 395 0.0080 0.99

+1 396 0.0073 0.99

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 57 SOF 1-Ws Sign (Ws) 397 0.0100 0.99

+1 398 0.0071 0.99

+1 399 0.0081 0.99

+1 400 0.0087 0.99

+1 401 0.0137 0.99

+1 402 0.0128 0.99

+1 403 0.0109 0.99

+1 404 0.0093 0.99

+1 405 0.0126 0.99

+1 406 0.0123 0.99

+1 407 0.0148 0.99

+1 408 0.0150 0.98

+1 409 0.0218 0.98

+1 410 0.0194 0.98

+1 411 0.0169 0.98

+1 412 0.0186 0.98

+1 413 0.0122 0.99

+1 414 0.0140 0.99

+1 415 0.0127 0.99

+1 416 0.0154 0.98

+1 417 0.0128 0.99

+1 418 0.0216 0.98

+1 419 0.0169 0.98

+1 420 0.0177 0.98

+1 421 0.0118 0.99

+1 422 0.0168 0.98

+1 423 0.0193 0.98

+1 424 0.0146 0.99

+1 425 0.0214 0.98

+1 426 0.0170 0.98

+1 427 0.0141 0.99

+1 428 0.0066 0.99

+1 429 0.0107 0.99

+1 430 0.0103 0.99

+1 431 0.0117 0.99

+1 432 0.0091 0.99

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 58 SOF 1-Ws Sign (Ws) 433 0.0113 0.99

+1 434 0.0073 0.99

+1 435 0.0060 0.99

+1 436 0.0015 1.00

+1 437 0.0042 1.00

+1 438 0.0030 1.00

+1 439 0.0025 1.00

+1 440 0.0039 1.00

+1 441 0.0030 1.00

+1 442 0.0049 1.00

+1 443 0.0038 1.00

+1 444 0.0006 1.00

+1 445 0.0003 1.00

+1 446 0.0027 1.00

+1 447 0.0019 1.00

+1 448 0.0017 1.00

+1 449 0.0033 1.00

+1 450 0.0048 1.00

+1 451 0.0050 1.00

+1 452 0.0065 0.99

+1 453 0.0031 1.00

+1 454 0.0063 0.99

+1 455 0.0018 1.00

+1 456 0.0050 0.99

+1 457 0.0017 1.00

+1 458 0.0000 1.00

+1 459 0.0065 0.99

+1 460 0.0038 1.00

+1 461 0.0041 1.00

+1 462 0.0009 1.00

+1 463 0.0000 1.00

+1 464 0.0000 1.00

+1 465 0.0027 1.00

+1 466 0.0081 0.99

+1 467 0.0114 0.99

+1 468 0.0103 0.99

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 59 SOF 1-Ws Sign (Ws) 469 0.0130 0.99

+1 470 0.0130 0.99

+1 471 0.0099 0.99

+1 472 0.0110 0.99

+1 473 0.0086 0.99

+1 474 0.0062 0.99

+1 475 0.0161 0.98

+1 476 0.0153 0.98

+1 477 0.0182 0.98

+1 478 0.0187 0.98

+1 479 0.0159 0.98

+1 480 0.0169 0.98

+1 481 0.0121 0.99

+1 482 0.0051 0.99

+1 483 0.0135 0.99

+1 484 0.0131 0.99

+1 485 0.0015 1.00

+1 486 0.0012 1.00

+1 487 0.0000 1.00

+1 488 0.0029 1.00

+1 489 0.0000 1.00

+1 490 0.0000 1.00

+1 491 0.0000 1.00

+1 492 0.0023 1.00

+1 493 0.0000 1.00

+1 494 0.0075 0.99

+1 495 0.0076 0.99

+1 496 0.0091 0.99

+1 497 0.0192 0.98

+1 498 0.0212 0.98

+1 499 0.0229 0.98

+1 500 0.0236 0.98

+1 501 0.0240 0.98

+1 502 0.0484 0.95

+1 503 0.0836 0.92

+1 504 0.0976 0.90

+1

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 60 SOF 1-Ws Sign (Ws) 505 0.0986 0.90

+1 506 0.0950 0.91

+1 507 0.0928 0.91

+1 508 0.0963 0.90

+1 509 0.0992 0.90

+1 510 0.0984 0.90

+1 Number of positive differences (S+)

510 Critical Value 274 Survey Unit Meets the Acceptance Criteria

61 FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 ATTACHMENT 4 QUALITY CONTROL ASSESSMENT

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 62 Table 16 Survey Unit S1-011-102 QC Assessment Standard Measurement Replicate 0

0 0

0 Y

0 0

0 0

Y 0

0 0

0 Y

0 0

0 0

Y 0

0 0

0 Y

159 191 127 0

N 339 407 271 122 N

585 701 468 295 N

186 223 149 246 N

0 0

0 0

Y 0

0 0

0 Y

0 0

0 0

Y 0

0 0

142 N

47 56 38 15 N

0 0

0 0

Y 0

0 0

0 Y

0 0

0 27 N

0 0

0 128 N

1037 1245 830 802 N

128 154 102 157 N

137 165 110 51 N

1102 1323 882 191 N

4687 5625 3750 2434 N

4738 5685 3790 3194 N

4765 5718 3812 4407 Y

E20 E20QC E24 E24QC Comments/Corrective Actions: The replicate measurement results are in acceptable agreement The acceptance criteria for replicate static measurements is that the same conclusion is reached for each measurement. This is defined as the replicate measurement being within 20% of the standard measurement. In cases where the replicate measurement is not within 20% of the standard measurement, but both measurements are below the Operational DCGL, there is an acceptable agreement.

E03 E03QC E14 E14QC E19 E19QC C90 C90QC D32 D32QC D79 D79QC C67 C67QC C85 C85QC C89 C89QC C24 C24QC C42 C42QC C56 C56QC A97 A97QC B20 B20QC C06 C06QC A66 A66QC A76 A76QC A95 A95QC A34 A34QC A40 A40QC A47 A47QC Activity Value Acceptable (Y/N)

A05 A05QC A12 A12QC ID Activity Value

+20%

-20%

ID

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 63 ATTACHMENT 5 GRAPHICAL PRESENTATIONS

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 64 Figure 16 Quantile Plot for Gross Gamma Activity

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 65 Figure 16 Histogram for Gross Gamma Activity

FSS RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 66 Figure 16 Retrospective Power Curve for Survey Unit S1-011-102