LA CROSSE BOILING WATER REACTOR FINAL STATUS SURVEY RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102

12/12/2019

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 2

TABLE OF CONTENTS

1.

EXECUTIVE

SUMMARY

................................................................................................................................. 5

2.

SURVEY UNIT DESCRIPTION....................................................................................................................... 5

3.

CLASSIFICATION BASIS................................................................................................................................. 5

4.

DATA QUALITY OBJECTIVES (DQO).......................................................................................................... 6

5.

SURVEY DESIGN............................................................................................................................................... 9

6.

SURVEY IMPLEMENTATION...................................................................................................................... 14

7.

SURVEY RESULTS.......................................................................................................................................... 15

8.

QUALITY CONTROL...................................................................................................................................... 20

9.

INVESTIGATIONS AND RESULTS.............................................................................................................. 20

10. REMEDIATION AND RESULTS................................................................................................................... 20
11. CHANGES FROM THE FINAL STATUS SURVEY PLAN........................................................................ 20
12. DATA QUALITY ASSESSMENT (DQA)....................................................................................................... 21
13. ANOMALIES..................................................................................................................................................... 21
14. CONCLUSION.................................................................................................................................................. 21
15. REFERENCES................................................................................................................................................... 22
16. ATTACHMENTS.............................................................................................................................................. 22 ATTACHMENT 1 - FIGURES AND MAPS............................................................................................................. 23 ATTACHMENT 2 - SCAN DATA............................................................................................................................. 28 ATTACHMENT 3 - SIGN TEST............................................................................................................................... 31 ATTACHMENT 4 - QUALITY CONTROL ASSESSMENT...................................................................................... 34 ATTACHMENT 5 - GRAPHICAL PRESENTATIONS............................................................................................. 36 ATTACHMENT 6 - LUDLUM 2350-1 DOWNLOAD REPORTS............................................................................ 40

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 3

LIST OF TABLES Table 3 Static Measurements for Characterization of Above Grade Buildings............................................... 6 Table 3 Summary Statistics for Characterization of Above Grade Buildings.................................................. 6 Table 4 Dose Significant Radionuclides and Mixture for Above Grade Buildings........................................... 8 Table 4 Base Case DCGLs for Above Grade Buildings (DCGLAGB).................................................................. 9 Table 4 Operational DCGLs for Above Grade Buildings (OpDCGLAGB)......................................................... 9 Table 5 Survey Unit B2-010-102 Measurement Designations........................................................................... 12 Table 5 Investigation Levels................................................................................................................................ 13 Table 5 Synopsis of Survey Design...................................................................................................................... 13 Table 7 Synopsis of Scan Results........................................................................................................................ 15 Table 7 Detector Efficiencies............................................................................................................................... 17 Table 7 Summary of Systematic, Judgmental, and QC Static Measurements................................................ 18 Table 7 Basic Statistical Properties of Systematic Measurement Population.................................................. 20 Table 16 Survey Unit B2-010-102 Complete Scan Data.................................................................................... 29 Table 16 Survey Unit B2-010-102 Sign Test....................................................................................................... 32 Table 16 Survey Unit B2-010-102 QC Assessment............................................................................................ 35 LIST OF FIGURES Figure 16 Survey Unit B2-010-102 Exterior Systematic and Judgmental Measurement Locations Map.... 24 Figure 16 Survey Unit B2-010-102 Interior Systematic and Judgmental Measurement Locations Map..... 25 Figure 16 Survey Unit B2-010-102 East Addition Systematic and Judgmental Measurement Locations Map

............................................................................................................................................................................. 26 Figure 16 Survey Unit B2-010-102 South Addition Systematic and Judgmental Measurement Locations Map..................................................................................................................................................................... 27 Figure 16 Quantile Plot for Gross Activity........................................................................................................ 37 Figure 16 Histogram for Gross Activity............................................................................................................. 38 Figure 16 Retrospective Power Curve................................................................................................................ 39

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 4

LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable ASP Alarm Set Point DQA Data Quality Assessment DQO Data Quality Objective DCGL Derived Concentration Guideline Level DCGLAGB Above Grade Building Derived Concentration Guideline Level FSS Final Status Survey GPS Global Positioning System G-3 Genoa 3 HSA Historical Site Assessment IC Insignificant Contributors LACBWR La Crosse Boiling Water Reactor LBGR Lower Bound of the Gray Region LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MDC Minimum Detectable Concentration MDCR Minimal Detectable Count Rate OpDCGLAGB Above Grade Building Operational Derived Concentration Guideline Level QAPP Quality Assurance Project Plan QC Quality Control ROC Radionuclides of Concern SOF Sum-of-Fraction TEDE Total Effective Dose Equivalent UBGR Upper Bound of the Gray Region UCL Upper Confidence Limit URS Unconditional Release Survey USNRC Unites States Nuclear Regulatory Commission

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 5

1.

EXECUTIVE

SUMMARY

This Final Status Survey (FSS) Release Record for survey unit B2-010-102, Genoa 3 (G-3)

Crib House, has been generated in accordance with LaCrosseSolutions procedure LC-FS-PR-009, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the La Crosse Boiling Water Reactor License Termination Plan (LACBWR LTP) (Reference 2).

An FSS sample plan for this survey unit was developed in accordance with LaCrosseSolutions procedures LC-FS-PR-015, Final Status Surveys for Structures (Reference 3) and LC-FS-PR-002, Final Status Survey Package Development (Reference 4), the LACBWR LTP, and with guidance from NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 5).

This above grade building survey unit has a MARSSIM classification of 2. A survey plan was designed based upon use of the Sign Test as the nonparametric statistical test for compliance. Both the Type I () and Type II () decision error rates were set at 0.05. As a systematic measurement population, fifty-six (56) static beta measurements were acquired from the survey unit. In addition, surface scanning was performed on approximately 27%

of the total surface area in the survey unit. The data assessment results for survey unit B2-010-102 indicate that the maximum gross activity among systematic measurements is equal to 1,488 dpm/100 cm2, which is 47.07% of the Adjusted Gross Operational Derived Concentration Guideline Level (DCGL) for above grade buildings (see Section 5 of this release record for the calculations of adjusted gross DCGLs). Therefore, the null hypothesis of the Sign test is rejected, and survey unit B2-010-102 is acceptable for unrestricted release.

The mean gross activity among systematic measurements is equal to 274 dpm/100 cm2, which is 1.39% of the Adjusted Gross Base Case DCGL. Multiplying this fraction by 25 mrem/yr results in a dose for the survey unit of 0.3469 mrem/yr.

2.

SURVEY UNIT DESCRIPTION B2-010-102 is an impacted Class 2 above grade building survey unit. The G-3 Crib House is utilized as the circulatory water pumping station for the G-3 Goal Plant. The survey unit consists of the interior and exterior surfaces of a main building, an east addition, and a south addition. The total surface area of the survey unit is 2,873 m2. Refer to Attachment 1 of this report for figures and maps depicting survey unit B2-010-102.

3.

CLASSIFICATION BASIS Based on the La Crosse Boiling Water Reactor Historical Site Assessment (HSA)

(Reference 6), survey unit B2-010-102 was identified as a Class 2 structure survey unit. The

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 6

following summarizes the results of the characterization surveys for seven (7) of the above grade buildings to be left on-site upon termination of the license.

The characterization surveys for the above grade buildings were conducted between November 8, 2016, and November 18, 2016. In total, fifty-six (56) static beta measurements were collected in the buildings (eight [8] in each of seven [7] buildings). No measurements exceeded their respective action levels. A summary of the static measurements are presented in Table 3-1. The summary statistics for the characterization data are provided in Table 3-2.

Table 3 Static Measurements for Characterization of Above Grade Buildings Static Beta Measurements (dpm/100 cm2)

LACBWR Crib House G-3 Crib House Back-Up Control Center Transmission Sub-Station Switch House Barge Wash Break Room G-1 Crib House Security Station 313 1,264 588 213 0

751 0

13 13 363 226 38 0

150 0

38 0

0 0

0 0

1,702 26 88 889 0

1,514 0

138 0

0 376 0

0 38 0

450 0

238 0

551 100 0

100 0

0 163 438 225 0

2,203 651 0

0 1,089 13 Table 3 Summary Statistics for Characterization of Above Grade Buildings Mean Median Minimum Maximum Standard Deviation (dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2) 267 32 0

2,203 473 Based upon review of the historical information, the results of the characterization survey data, and completion of a final Survey Unit Classification Worksheet, the correct final classification of survey unit B2-010-102 was determined to be Class 2.

4.

DATA QUALITY OBJECTIVES FSS planning and design relies on a properly executed Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process, utilized in accordance

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 7

with MARSSIM, is described in the LACBWR LTP. The appropriate design for a given survey was developed using the DQO process as outlined in Appendix D of MARSSIM.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.

The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in survey unit B2-010-102 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

LaCrosseSolutions TSD RS-TD-313196-001, Radionuclides of Concern during LACBWR Decommissioning (Reference 7) established the basis for an initial suite of potential ROC for decommissioning. Insignificant contributors (IC) were determined consistent with the guidance contained in Section 3.3 of NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance - Characterization, Survey, and Determination of Radiological Criteria, Final Report (Reference 8). In all soil and concrete scenarios, Cs-137, Co-60, Sr-90, Eu-152 and Eu-154 contribute nearly 100% of the total dose. The remaining radionuclides were designated as IC and were eliminated from further detailed evaluation. Therefore, the final ROCs for LACBWR above grade buildings, soil, basement concrete, and buried piping are Cs-137, Co-60, Sr-90, Eu-152 and Eu-154.

The LTP, Section 6.14.1 discusses the process used to derive the ROC for the decommissioning of LACBWR, including the elimination of IC from the initial suite.

Table 4-1 presents the ROC for the decommissioning of above grade buildings at LACBWR and the normalized mixture fractions based on the radionuclide mixture.

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 8

Table 4 Dose Significant Radionuclides and Mixture for Above Grade Buildings Radionuclide Fraction of Total Activity (normalized)(1)

Co-60 0.0644 Sr-90 0.0981 Cs-137 0.829 Eu-152 0.00549 Eu-154 0.00281 (1) Based on maximum percent of total activity from Table 22 of RS-TD-313196-001, normalized to one for the dose significant radionuclides.

LTP, Section 5.2 states that each radionuclide-specific Base Case DCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem/yr to an Average Member of the Critical Group. To ensure that the summation of dose from each source term is 25 mrem/yr or less after all FSS is completed, the Base Case DCGLs are reduced based on an expected, or a priori, fraction of the 25 mrem/yr dose limit from each source term. The reduced DCGLs, or Operational DCGLs, can be related to the Base Case DCGLs as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge, and the extent of planned remediation. The Operational DCGL is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigations levels, etc.).

Details of the Operational DCGLs derived for each dose component and the basis for the applied a priori dose fractions are provided in LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey (Reference 9).

At LACBWR, compliance is demonstrated through the summation of dose from five (5) distinct source terms (i.e., basements, soils, buried pipe, above grade buildings, and groundwater) for the end-state. When applied to above grade buildings, the DCGLs are expressed in units of activity per surface area (dpm/100 cm2).

The Screening Values in NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance - Characterization, Survey, and Determination of Radiological Criteria, Final Report, Table H-1, are applied to the FSS of above grade buildings. The Table H-1 Screening Values are presented as Base Case DCGLs (equivalent to 25 mrem/yr) and are reproduced in Table 4-2 below.

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 9

Table 4 Base Case DCGLs for Above Grade Buildings (DCGLAGB)

Radionuclide DCGLAGB (dpm/100cm2)

Co-60 7,100 Sr-90 8,700 Cs-137 28,000 Eu-152 12,700 Eu-154 11,500 The Operational DCGLs are then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigation levels, etc.). The Operational DCGLs for the unrestricted release of above grade buildings are provided in Table 4-3.

Table 4 Operational DCGLs for Above Grade Buildings (OpDCGLAGB)

Radionuclide OpDCGLAGB (dpm/100cm2)

Co-60 1,136 Sr-90 1,392 Cs-137 4,480 Eu-152 2,032 Eu-154 1,840 Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the Operational DCGL. Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data. The minimum acceptable MDC for measurements obtained using field instruments was 50% of the applicable Operational DCGL.

5.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey unit and nature of the hazards. Guidance for preparing FSS plans is provided in procedures LC-FS-PR-015, Final Status Surveys for Structures and LC-FS-PR-002, Final Status Survey Package Development.

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 10 For the FSS of above grade buildings, Adjusted Gross DCGLs are calculated. This is done because radionuclide-specific data is not acquired with static measurements. The equation for calculating the Adjusted Gross DCGL is as follows:

Equation 1

=

1

[(

1

1) + (

2

2) + (

)]

Where:

DCGLAG

= Adjusted Gross DCGL in units of dpm/100 cm2 DCGLi

= Gross DCGL for detectable radionuclide in units of dpm/100 cm2 fi

= Mixture fraction of detectable radionuclides Using Equation 1, and values within Tables 4-1 and 4-3, the Adjusted Gross Operational DCGL was calculated as follows:

Equation 2

=

1

[(

0.0644 1136(60)) + (

0.0981 1392(90)) + (

0.829 4480(137)) + (

0.00549 2032(152)) + (

0.00281 1840(154))]

= 3160 /100 2 The Adjusted Gross Operational DCGL was calculated as 3,160 dpm/100 cm2, which was the action level for survey unit B2-010-102.

Using Equation 1, and values within Tables 4-1 and 4-2, the Adjusted Gross Base Case DCGL was calculated as follows:

Equation 3

=

1

[(

0.0644 7100(60)) + (

0.0981 8700(90)) + (

0.829 28000(137)) + (

0.00549 12700(152)) + (

0.00281 11500(154))]

= 19751 /100 2

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 11 The Adjusted Gross Base Case DCGL was calculated as 19,751 dpm/100 cm2. The mean activity from the FSS systematic measurements is compared to the Adjusted Gross Base Case DCGL, and the dose contribution from the survey unit is calculated.

The Sign test was selected as the nonparametric statistical test for compliance with the release criteria. The number of measurements for use with the Sign test was determined in accordance with procedures LC-FS-PR-002 and LC-FS-PR-015. The relative shift (/) for the survey unit data set is defined as shift (), which is the Upper Boundary of the Gray Region (UBGR), or the DCGL, minus the Lower Bound of the Gray Region (LBGR),

divided by sigma (), which is the standard deviation of the data set used for survey design.

The optimal value for / should range between one (1) and three (3). The largest value the

/ can have is three (3). If the calculated value of / exceeds three (3), an adjusted value of three (3) will be used for /. The / for survey unit B2-010-102, based on the amalgamated gross measurement data from characterization of the LACBWR above grade buildings to remain at license termination, was calculated as follows:

Equation 4

/

=

1580/473

=

3.34 As the calculated relative shift was greater than three (3), then a value of three (3) was used as the adjusted /. Both the Type I error (i.e., value) and the Type II error (i.e., value) was set at 0.05. The sample size from Table 5.5 of MARSSIM that equates to the Type I and Type II error of 0.05 for use with the Sign test is an N value of fourteen (14). Fifty-six (28) total systematic measurements (14 interior and 14 exterior on main building, 14 in the east addition, and 14 in the south addition) were included in the survey design for survey unit B2-010-102.

A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10CFR20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

As the survey unit was designated Class 2, measurement locations were selected based on a systematic grid with a random starting point. The systematic locations of the static measurements were selected using Visual Sample Plan (VSP). Input parameters included the use of survey unit drawings and the systematic sampling tool set with a predetermined number of measurement locations. The systematic measurement locations were identified in the field using dimension parameters provided on the survey unit map (see Attachment 1). Table 5-1 lists the systematic, judgmental, and QC measurements collected for FSS of survey unit B2-010-102.

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 12 Table 5 Survey Unit B2-010-102 Measurement Designations Measurement ID B2-010-102-FSCC-B01-BD B2-010-102-FSWM-A13-BD B2-010-102-FSCC-B02-BD B2-010-102-FSWM-A14-BD B2-010-102-FSCC-B03-BD B2-010-102-FSWM-B04-BD B2-010-102-FSCC-D07-BD B2-010-102-FSWM-B05-BD B2-010-102-FSCC-D08-BD B2-010-102-FSWM-B08-BD B2-010-102-FSCC-D09-BD B2-010-102-FSWM-B12-BD B2-010-102-FSFC-B06-BD B2-010-102-FSWM-B14-BD B2-010-102-FSFC-B09-BD B2-010-102-FSWM-C01-BD B2-010-102-FSFC-B10-BD B2-010-102-FSWM-C03-BD B2-010-102-FSFC-B13-BD B2-010-102-FSWM-C04-BD B2-010-102-FSFC-C02-BD B2-010-102-FSWM-C05-BD B2-010-102-FSFC-D02-BD B2-010-102-FSWM-C06-BD B2-010-102-FSFC-D05-BD B2-010-102-FSWM-C07-BD B2-010-102-FSRO-A06-BD B2-010-102-FSWM-C08-BD B2-010-102-FSRO-A07-BD B2-010-102-FSWM-C09-BD B2-010-102-FSRO-A10-BD B2-010-102-FSWM-C11-BD B2-010-102-FSRO-A11-BD B2-010-102-FSWM-C12-BD B2-010-102-FSRO-C10-BD B2-010-102-FSWM-C13-BD B2-010-102-FSRO-D11-BD B2-010-102-FSWM-C14-BD B2-010-102-FSRO-D12-BD B2-010-102-FSWM-D03-BD B2-010-102-FSRO-D13-BD B2-010-102-FSWM-D04-BD B2-010-102-FSWK-B07-BD B2-010-102-FSWM-D06-BD B2-010-102-FSWK-B11-BD B2-010-102-FSWM-D10-BD B2-010-102-FSWK-D01-BD B2-010-102-FSWM-D14-BD B2-010-102-FSWM-A01-BD B2-010-102-FQFC-D05-BD B2-010-102-FSWM-A02-BD B2-010-102-FQRO-A07-BD B2-010-102-FSWM-A03-BD B2-010-102-FQRO-C10-BD B2-010-102-FSWM-A04-BD B2-010-102-FQWM-B12-BD B2-010-102-FSWM-A05-BD B2-010-102-FJFC-B15-BD B2-010-102-FSWM-A08-BD B2-010-102-FJFC-C15-BD B2-010-102-FSWM-A09-BD B2-010-102-FJWM-A15-BD B2-010-102-FSWM-A12-BD B2-010-102-FJWM-D15-BD

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 13 The implementation of quality control measures, as referenced in LTP, Section 5.9, and LaCrosseSolutions LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan (QAPP) (Reference 10), includes the collection of a replicate measurement on 5% of the measurements collected in a survey unit, with the locations selected at random. Four (4) replicate measurements, B2-010-102-FQFC-A07-BD, B2-010-102-FQWM-B12-BD, B2-010-102-FQRO-C10-BD, and B2-010-102-FQRO-D05-BD, were selected at random for the QC replicate measurement analysis for the FSS of this survey unit.

The LTP, Section 5.6.4.4 and Table 5-15, specifies that for Class 2 structure survey units, systematic and judgmental surface scans will be performed on 10% to 100% of the surface area in the survey unit. For survey unit B2-010-102, 25% scan coverage was selected, which equates to 718 m2. Sixty (60) scan areas (one [1] scan area at each systematic measurement location and four [4] judgmental scan areas), covering 780 m2 of the survey unit (more than the required minimum), were established. Refer to Attachment 1 for figures and maps depicting the measurement and scan locations in survey unit B2-010-102.

For this Class 2 structure survey unit, the Investigation Levels for area scanning and direct measurement results are those levels specified in the LTP, Table 5-16, and are reproduced below in Table 5-2.

Table 5 Investigation Levels Classification Scan Investigation Levels Direct Investigation Levels Class 2

>Operational DCGL or >MDCscan if MDCscan is greater than Operational DCGL

>Operational DCGL Table 5-3 provides a synopsis of the survey design for survey unit B2-010-102.

Table 5 Synopsis of Survey Design Feature Design Criteria Basis Survey Unit Surface Area 2,873 m2 Building Dimensions Number of Systematic Measurements (N) 56

= 473 UBGR = 3,160 LBGR = 1,580 Type I & II error = 0.05

/ = 3 (adjusted)

MARSSIM Table 5.5 DCGL/Action Level 3,160 dpm/100 cm2 Adjusted Gross Operational DCGL (Equation 2)

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 14 Feature Design Criteria Basis Direct Investigation Level

>Operational DCGL LTP, Table 5-16 Scan Investigation Level

>Operational DCGL or >MDCscan LTP, Table 5-16 Scan Areal Coverage 780 m2 (with 4 judgmental scan areas) or ~27%

LTP, Table 5-15 Actual Scan Coverage Judgmental Measurements 4

Per Survey Design QC 4 replicate measurements selected at random locations LTP, Section 5.9

6.

SURVEY IMPLEMENTATION For survey unit B2-010-102, compliance with the unrestricted release criteria was demonstrated through a combination of surface scanning and surface static measurements with a Ludlum Model 44-116 beta/gamma detector.

An FSS Supervisor performed a visual inspection and walk-down of the survey unit during the Unconditional Release Survey (URS) that was performed prior to FSS. The purpose of the walk-down was to assess the physical condition of the survey unit, evaluate access points and travel paths, and identify potentially hazardous conditions. At the time of FSS, the interior and exterior of the building was dry and reasonably free of debris. No conditions prohibited the proper collection of static and scan measurements.

FSS field activities were conducted under the FSS Sample Plan, which included DQOs, survey design, detailed FSS instructions, job safety analysis, and related procedures for reference. FSS field activities were projected to take four (4) working days to complete.

Daily briefings were conducted to discuss the expectations for job performance and to review safety aspects of the job. A Field Log was used to document field activities and other information pertaining to the performance of the FSS. FSS field activities commenced on June 7, 2019, and were concluded on July 17, 2019.

A total of sixty (60) different scan areas (fifty-six [56] systematic and four [4] judgmental),

constituting an areal coverage of 780 m2, were scanned using a Ludlum 2350-1 paired with a Ludlum Model 44-116 detector (125 cm2 detector area). The background was established as the average of five (5) 1-minute static measurements, while maintaining the detector waist high. In survey unit B2-010-102, background ranged from 160 cpm up to 302 cpm.

All designated scan areas were scanned using a Ludlum 2350-1 paired with a Model 44-116 beta/gamma detector operated in the rate-meter mode and using audio response. The probe was positioned as close to the surface as possible and was moved at a scan speed of approximately one (1) detector width per second. Scan MDC was sufficient to detect

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 15 residual radioactivity at the action level of 3,160 dpm/100cm2 (Adjusted Gross Operational DCGL). Complete scan results are provided in Attachment 2.

The fifty-six (56) systematic static measurement locations were marked based on the dimensions provided on the survey map. Four (4) judgmental measurement locations were selected and marked as per the sample plan. Using the Ludlum 2350-1 paired with a Model 44-116 detector, a 1-minute static measurement was acquired at the location of highest scan indication within each systematic and judgmental scan area.

The implementation of survey specific QC measures included the collection of four (4) replicate static measurements (B2-010-102-FQFC-A07-BD, B2-010-102-FQWM-B12-BD, B2-010-102-FQRO-C10-BD, and B2-010-102-FQRO-D05-BD) for QC analysis.

7.

SURVEY RESULTS All areas identified in the FSS plan were scanned for elevated activity levels. No alarms were produced during the scanning of survey unit B2-010-102. Table 7-1 provides an overview of the scan results. Complete scan results are provided in Attachment 2.

Table 7 Synopsis of Scan Results Scan Area Highest Logged Reading Action Level(1)

  1. of Scan Alarms Investigation Measurements (cpm)

(cpm)

A01 308 456 0

0 A02 277 456 0

0 A03 224 535 0

0 A04 208 535 0

0 A05 253 513 0

0 A06 481 631 0

0 A07 441 631 0

0 A07 Q 612 803 0

0 A08 203 513 0

0 A09 213 513 0

0 A10 406 631 0

0 A11 476 631 0

0 A12 272 456 0

0 A13 253 513 0

0 A14 372 513 0

0 A15 J 415 516 0

0

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 16 Scan Area Highest Logged Reading Action Level(1)

  1. of Scan Alarms Investigation Measurements (cpm)

(cpm)

B01 379 644 0

0 B02 453 644 0

0 B03 449 644 0

0 B04 374 541 0

0 B05 422 541 0

0 B06 456 521 0

0 B07 513 541 0

0 B08 228 644 0

0 B09 517 521 0

0 B10 423 521 0

0 B11 433 541 0

0 B12 378 541 0

0 B12 Q 347 456 0

0 B13 421 521 0

0 B14 410 541 0

0 B15 J 484 541 0

0 C01 413 467 0

0 C02 320 467 0

0 C03 329 467 0

0 C04 358 467 0

0 C05 433 467 0

0 C06 338 467 0

0 C07 363 475 0

0 C08 300 475 0

0 C09 252 475 0

0 C10 630 735 0

0 C10 Q 489 631 0

0 C11 353 475 0

0 C12 264 475 0

0 C13 269 475 0

0 C14 280 475 0

0 C15 J 396 475 0

0 D01 508 571 0

0 D02 447 571 0

0

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 17 Scan Area Highest Logged Reading Action Level(1)

  1. of Scan Alarms Investigation Measurements (cpm)

(cpm)

D03 359 492 0

0 D04 423 571 0

0 D05 399 492 0

0 D05 Q 299 644 0

0 D06 418 492 0

0 D07 409 492 0

0 D08 561 605 0

0 D09 448 492 0

0 D10 319 571 0

0 D11 485 492 0

0 D12 475 492 0

0 D13 447 492 0

0 D14 259 492 0

0 D15 J 442 492 0

0 (1) Action Level for scanning was conservatively based on the average background plus 50% of the Operational DCGL converted to cpm using the detector efficiency.

Background was subtracted from all measurements, then the measurements were converted from cpm to dpm/100 cm2 (net cpm divided by detector efficiency) for direct comparison to the Adjusted Gross DCGLs. Table 7-2 below presents the detector efficiencies used for conversions. A summary of the results for the fifty-six (56) systematic static measurements, four (4) judgmental static measurements, and four (4) QC static measurements is provided in Table 7-3. The basic statistics for the systematic measurement population are summarized in Table 7-4.

Table 7 Detector Efficiencies44-116 Detector #

Efficiency (c/d) 222981 0.1653 223244 0.1698 357009 0.2104 357439 0.2169

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 18 Table 7 Summary of Systematic, Judgmental, and QC Static Measurements Measurement ID Gross Activity Fraction of Adjusted Gross OpDCGL (dpm/100 cm2)

B2-010-102-FSCC-B01-BD 466 0.1474 B2-010-102-FSCC-B02-BD 304 0.0963 B2-010-102-FSCC-B03-BD 535 0.1692 B2-010-102-FSCC-D07-BD 1488 0.4707 B2-010-102-FSCC-D08-BD 452 0.1429 B2-010-102-FSCC-D09-BD 775 0.2451 B2-010-102-FSFC-B06-BD 417 0.1321 B2-010-102-FSFC-B09-BD 575 0.1819 B2-010-102-FSFC-B10-BD 351 0.1110 B2-010-102-FSFC-B13-BD 181 0.0574 B2-010-102-FSFC-C02-BD 695 0.2199 B2-010-102-FSFC-D02-BD 138 0.0436 B2-010-102-FSFC-D05-BD 333 0.1053 B2-010-102-FSRO-A06-BD 420 0.1328 B2-010-102-FSRO-A07-BD 775 0.2451 B2-010-102-FSRO-A10-BD 641 0.2028 B2-010-102-FSRO-A11-BD 549 0.1736 B2-010-102-FSRO-C10-BD 1396 0.4417 B2-010-102-FSRO-D11-BD 490 0.1549 B2-010-102-FSRO-D12-BD 447 0.1414 B2-010-102-FSRO-D13-BD 413 0.1308 B2-010-102-FSWK-B07-BD 0

0.0000 B2-010-102-FSWK-B11-BD 36 0.0115 B2-010-102-FSWK-D01-BD 86 0.0271 B2-010-102-FSWM-A01-BD 0

0.0000 B2-010-102-FSWM-A02-BD 53 0.0168 B2-010-102-FSWM-A03-BD 0

0.0000 B2-010-102-FSWM-A04-BD 0

0.0000 B2-010-102-FSWM-A05-BD 41 0.0131 B2-010-102-FSWM-A08-BD 235 0.0744 B2-010-102-FSWM-A09-BD 350 0.1109 B2-010-102-FSWM-A12-BD 0

0.0000

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 19 Measurement ID Gross Activity Fraction of Adjusted Gross OpDCGL (dpm/100 cm2)

B2-010-102-FSWM-A13-BD 277 0.0875 B2-010-102-FSWM-A14-BD 286 0.0905 B2-010-102-FSWM-B04-BD 0

0.0000 B2-010-102-FSWM-B05-BD 0

0.0000 B2-010-102-FSWM-B08-BD 0

0.0000 B2-010-102-FSWM-B12-BD 0

0.0000 B2-010-102-FSWM-B14-BD 0

0.0000 B2-010-102-FSWM-C01-BD 0

0.0000 B2-010-102-FSWM-C03-BD 571 0.1808 B2-010-102-FSWM-C04-BD 0

0.0000 B2-010-102-FSWM-C05-BD 0

0.0000 B2-010-102-FSWM-C06-BD 0

0.0000 B2-010-102-FSWM-C07-BD 665 0.2106 B2-010-102-FSWM-C08-BD 777 0.2460 B2-010-102-FSWM-C09-BD 0

0.0000 B2-010-102-FSWM-C11-BD 0

0.0000 B2-010-102-FSWM-C12-BD 0

0.0000 B2-010-102-FSWM-C13-BD 0

0.0000 B2-010-102-FSWM-C14-BD 0

0.0000 B2-010-102-FSWM-D03-BD 0

0.0000 B2-010-102-FSWM-D04-BD 0

0.0000 B2-010-102-FSWM-D06-BD 95 0.0301 B2-010-102-FSWM-D10-BD 0

0.0000 B2-010-102-FSWM-D14-BD 38 0.0120 B2-010-102-FQFC-D05-BD 0

0.0000 B2-010-102-FQRO-A07-BD 0

0.0000 B2-010-102-FQRO-C10-BD 793 0.2509 B2-010-102-FQWM-B12-BD 0

0.0000 B2-010-102-FJFC-B15-BD 0

0.0000 B2-010-102-FJFC-C15-BD 0

0.0000 B2-010-102-FJWM-A15-BD 14 0.0044 B2-010-102-FJWM-D15-BD 632 0.2000

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 20 Table 7 Basic Statistical Properties of Systematic Measurement Population Mean Median Max Min Std. Dev.

Adjusted Gross BcDCGL Mean Adjusted Gross BcDCGL Fraction Dose (mrem/

yr)

(dpm/100cm2)

(dpm/100cm2)

(dpm/100cm2)

(dpm/100cm2)

(dpm/100cm2)

(dpm/100cm2) 274 69 1488 0

340 19751 0.0139 0.3469 The mean activity from systematic static measurements was divided by the Adjusted Gross Base Case DCGL to derive a mean fraction. The mean fraction was then multiplied by twenty-five (25) mrem/yr to derive the dose attributed to the survey unit. For survey unit B2-010-102, the calculated dose from residual activity is 0.3469 mrem/yr.

8.

QUALITY CONTROL The implementation of survey specific QC measures included the collection of two (2) replicate static measurements (B2-010-102-FQCM-B05-BD and B2-010-102-FQWM-A01-BD) for QC analysis. The acceptance criterion for replicate static measurements is that the same conclusion is reached for each measurement. The acceptance criterion is satisfied if the replicate measurement is within 20% of the standard measurement. In cases where the replicate measurement is not within 20% of the standard measurement, but both measurements are below the Operational DCGL as well as the static MDC, there is an acceptable agreement. The QC replicate measurements did not fall within the 20% criteria, but both the standard and replicate measurements were well below the Adjusted Gross Operational DCGL as well as the static MDC, and no further action was deemed necessary.

9.

INVESTIGATIONS AND RESULTS No investigations were performed during the performance or analyses of the survey.

10.

REMEDIATION AND RESULTS No radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Chapter 4 of the LTP determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in above grade buildings was ALARA.

11.

CHANGES FROM THE FINAL STATUS SURVEY PLAN There were no addendums to the FSS plan.

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 21

12.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with LC-FS-PR-008, Final Status Survey Data Assessment (Reference 11) for completeness and consistency.

Documentation was complete and legible. Scan surveys and the collection of static measurements were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2. The survey design had adequate power as indicated by the Retrospective Power Curve (see Attachment 5).

The measurement results indicated that all measurements were less than 50% of the Adjusted Gross Operational DCGL.

Although MARSSIM states that the Sign test need not be performed in the instance that no measurements exceed the DCGL, the test was conducted to demonstrate coherence to the statistical principles of the DQO process. The Sign test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign test results clearly demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected. The results of the Sign test are presented in Attachment 3.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values of the data were well below the Adjusted Gross Operational DCGL. Also, the retrospective power curve shows that a sufficient number of measurements were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

The survey unit data is presented graphically through a frequency plot and quantile plot. All graphical presentations are provided in Attachment 5.

13.

ANOMALIES No anomalies were observed during the performance or analyses of the survey.

14.

CONCLUSION Survey unit B2-010-102 has met the DQOs of the FSS plan. The ALARA criteria as specified in Chapter 4 of the LTP were achieved.

The sample data passed the Sign test. The null hypothesis was rejected. The Retrospective Power Curve showed that adequate power was achieved. The survey unit is properly classified as Class 2. Therefore, in accordance with the LTP, Section 5.11, the survey unit meets the release criteria.

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 22 The dose contribution from survey unit B2-010-102 is 0.3469 mrem/yr TEDE, based on the mean activity of measurements used for non-parametric statistical sampling.

Survey unit B2-010-102 is acceptable for unrestricted release.

15.

REFERENCES

1. LC-FS-PR-009, Final Status Survey Data Reporting
2. La Crosse Boiling Water Reactor License Termination Plan
3. LC-FS-PR-015, Final Status Surveys for Structures
4. LC-FS-PR-002, Final Status Survey Package Development
5. NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM)
6. La Crosse Boiling Water Reactor Historical Site Assessment
7. RS-TD-313196-001, Radionuclides of Concern during LACBWR Decommissioning
8. NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance -

Characterization, Survey, and Determination of Radiological Criteria, Final Report

9. LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey
10. LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan
11. LC-FS-PR-008, Final Status Survey Data Assessment
16.

ATTACHMENTS

- Figures and Maps

- Scan Data

- Sign Test

- Quality Control Assessment

- Graphical Presentations

- Ludlum 2350-1 Download Reports

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 23 ATTACHMENT 1 FIGURES AND MAPS

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 24 Figure 16 Survey Unit B2-010-102 Exterior Systematic and Judgmental Measurement Locations Map

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 25 Figure 16 Survey Unit B2-010-102 Interior Systematic and Judgmental Measurement Locations Map

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 26 Figure 16 Survey Unit B2-010-102 East Addition Systematic and Judgmental Measurement Locations Map

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 27 Figure 16 Survey Unit B2-010-102 South Addition Systematic and Judgmental Measurement Locations Map

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 28 ATTACHMENT 2 SCAN DATA

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 29 Table 16 Survey Unit B2-010-102 Complete Scan Data Detector Type Detector ID M2350-1 ID Location Scan Logged Result Avg

Background

Action Level(1)

Scan Alarms (cpm)

(cpm)

(cpm)44-116 223244 98647 A01 308 188 456 0

44-116 223244 98647 A02 277 188 456 0

44-116 357439 325261 A03 224 193 535 0

44-116 357439 325261 A04 208 193 535 0

44-116 357439 325261 A05 253 171 513 0

44-116 357439 325261 A06 481 289 631 0

44-116 357439 325261 A07 441 289 631 0

44-116 357009 325246 A07 Q 612 471 803 0

44-116 357439 325261 A08 203 171 513 0

44-116 357439 325261 A09 213 171 513 0

44-116 357439 325261 A10 406 289 631 0

44-116 357439 325261 A11 476 289 631 0

44-116 223244 98647 A12 272 188 456 0

44-116 357439 325261 A13 253 171 513 0

44-116 357439 325261 A14 372 171 513 0

44-116 357439 325261 A15 J 415 173 516 0

44-116 357439 325261 B01 379 302 644 0

44-116 357439 325261 B02 453 302 644 0

44-116 357439 325261 B03 449 302 644 0

44-116 222981 126195 B04 374 280 541 0

44-116 222981 126195 B05 422 280 541 0

44-116 222981 126195 B06 456 250 521 0

44-116 222981 126195 B07 513 280 541 0

44-116 357439 325261 B08 228 302 644 0

44-116 222981 126195 B09 517 250 521 0

44-116 222981 126195 B10 423 250 521 0

44-116 222981 126195 B11 433 280 541 0

44-116 222981 126195 B12 378 280 541 0

44-116 223244 98647 B12 Q 347 188 456 0

44-116 222981 126195 B13 421 250 521 0

44-116 222981 126195 B14 410 280 541 0

44-116 222981 126195 B15 J 484 280 541 0

44-116 223244 98647 C01 413 199 467 0

44-116 223244 98647 C02 320 199 467 0

44-116 223244 98647 C03 329 199 467 0

44-116 223244 98647 C04 358 199 467 0

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 30 Detector Type Detector ID M2350-1 ID Location Scan Logged Result Avg

Background

Action Level(1)

Scan Alarms (cpm)

(cpm)

(cpm)44-116 223244 98647 C05 433 199 467 0

44-116 223244 98647 C06 338 199 467 0

44-116 223244 98647 C07 363 208 475 0

44-116 223244 98647 C08 300 208 475 0

44-116 223244 98647 C09 252 208 475 0

44-116 223244 98647 C10 630 469 735 0

44-116 357439 325261 C10 Q 489 289 631 0

44-116 223244 98647 C11 353 208 475 0

44-116 223244 98647 C12 264 208 475 0

44-116 223244 98647 C13 269 208 475 0

44-116 223244 98647 C14 280 208 475 0

44-116 223244 98647 C15 J 396 208 475 0

44-116 357009 325246 D01 508 239 571 0

44-116 357009 325246 D02 447 239 571 0

44-116 357009 325246 D03 359 160 492 0

44-116 357009 325246 D04 423 239 571 0

44-116 357009 325246 D05 399 160 492 0

44-116 357439 325261 D05 Q 299 302 644 0

44-116 357009 325246 D06 418 160 492 0

44-116 357009 325246 D07 409 160 492 0

44-116 357009 325246 D08 561 273 605 0

44-116 357009 325246 D09 448 160 492 0

44-116 357009 325246 D10 319 239 571 0

44-116 357009 325246 D11 485 160 492 0

44-116 357009 325246 D12 475 160 492 0

44-116 357009 325246 D13 447 160 492 0

44-116 357009 325246 D14 259 160 492 0

44-116 357009 325246 D15 J 442 160 492 0

(1) Action Level for scanning was conservatively based on the average background plus 50% of the Operational DCGL converted to cpm using the detector efficiency.

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 31 ATTACHMENT 3 SIGN TEST

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 32 Table 16 Survey Unit B2-010-102 Sign Test SOF 1-WS Sign (WS) 1 0.1474 0.8526

+1 2

0.0963 0.9037

+1 3

0.1692 0.8308

+1 4

0.4707 0.5293

+1 5

0.1429 0.8571

+1 6

0.2451 0.7549

+1 7

0.1321 0.8679

+1 8

0.1819 0.8181

+1 9

0.1110 0.8890

+1 10 0.0574 0.9426

+1 11 0.2199 0.7801

+1 12 0.0436 0.9564

+1 13 0.1053 0.8947

+1 14 0.1328 0.8672

+1 15 0.2451 0.7549

+1 16 0.2028 0.7972

+1 17 0.1736 0.8264

+1 18 0.4417 0.5583

+1 19 0.1549 0.8451

+1 20 0.1414 0.8586

+1 21 0.1308 0.8692

+1 22 0.0000 1.0000

+1 23 0.0115 0.9885

+1 24 0.0271 0.9729

+1 25 0.0000 1.0000

+1 26 0.0168 0.9832

+1 27 0.0000 1.0000

+1 28 0.0000 1.0000

+1 29 0.0131 0.9869

+1 30 0.0744 0.9256

+1 31 0.1109 0.8891

+1 32 0.0000 1.0000

+1 33 0.0875 0.9125

+1 34 0.0905 0.9095

+1 35 0.0000 1.0000

+1 36 0.0000 1.0000

+1 37 0.0000 1.0000

+1 38 0.0000 1.0000

+1 39 0.0000 1.0000

+1 40 0.0000 1.0000

+1 41 0.1808 0.8192

+1 42 0.0000 1.0000

+1 43 0.0000 1.0000

+1

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 33 SOF 1-WS Sign (WS) 44 0.0000 1.0000

+1 45 0.2106 0.7894

+1 46 0.2460 0.7540

+1 47 0.0000 1.0000

+1 48 0.0000 1.0000

+1 49 0.0000 1.0000

+1 50 0.0000 1.0000

+1 51 0.0000 1.0000

+1 52 0.0000 1.0000

+1 53 0.0000 1.0000

+1 54 0.0301 0.9699

+1 55 0.0000 1.0000

+1 56 0.0120 0.9880

+1 Number of positive differences (S+)

56 Critical Value 34 Survey Unit Meets the Acceptance Criteria

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 34 ATTACHMENT 4 QUALITY CONTROL ASSESSMENT

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 35 Table 16 Survey Unit B2-010-102 QC Assessment Standard Activity (dpm/100cm2)

-20%

+20%

Comparison Activity (dpm/100cm2) Within 20%

B2-010-102-FSFC-D05-BD 333 266 399 B2-010-102-FQFC-D05-BD 0

N B2-010-102-FSRO-A07-BD 775 620 929 B2-010-102-FQRO-A07-BD 0

N B2-010-102-FSRO-C10-BD 1396 1117 1675 B2-010-102-FQRO-C10-BD 793 N

B2-010-102-FSWM-B12-BD 0

0 0

B2-010-102-FQWM-B12-BD 0

N

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 36 ATTACHMENT 5 GRAPHICAL PRESENTATIONS

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 37 Figure 16 Quantile Plot for Gross Activity

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 38 Figure 16 Histogram for Gross Activity

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 39 Figure 16 Retrospective Power Curve

FSS RELEASE RECORD GENOA 3 CRIB HOUSE SURVEY UNIT B2-010-102 ATTACHMENT 6 LUDLUM 2350-1 DOWNLOAD REPORTS