Rev 1 to Monthly Operating Status Rept for Nov 1989 for Cooper Nuclear Station
ML20005G570
Person / Time
Site: Cooper 
Issue date: 11/30/1989
From:
NEBRASKA PUBLIC POWER DISTRICT
To:
Shared Package
ML20005G563 List:
References
NUDOCS 9001190345
Download: ML20005G570 (2)


Text

_-o L

l h

m.

OPERATING DATA REPORT

\\

"i DOCKET NO.

050-0298

F UNIT CNS E

DATE _ January 8. 1990

.l OPERATING STATUS TELEPHONE (402) 825 5291 i

1.

Unit Name:

Cooner Nuclear Station

. Notes 3.

Reportme period:

November 1999. Revialon 1

  • - indicates revised values s

3.

Usensed Thermal Power (MWt):

2381

)

5

' Nameplate Moline (Gross MWo):

836 4

6.

Design Electrieel Reting (Not MWo): 778 j

6.

Maximum Dependable Capacity (Groes MWo): 787' j

Ti

- Maximum Dependable Capaolty (Not MWe):

764 8.

W Changes Occur in Capacity Retings (home Number 3 Through 7) Since Last Report, Give Reasons:

I 9..

Power 14 vel To Whloh Restricted, N Any (Not MWe):

-i

10. '

Reasons For Restriction,N Any:

This Month Yr.-to.Dete Cumulative 11, Hours in Reportine Period 720.0 8.016.0 135.169.0 12.

Number of Hours Reactor Was Crition!

601.7

  • 5.935.8
  • 101.911.1 *

' 13.

Reactor Reserve Shutdown Hours 0.0 0.0 0.0_

14.

Hours Generator On Une 598.3 5.870.3 100.304.9 16.

Unit Reserve Shutdown Hours 0.0 0.0 0.0 16.

Groes Thermal Energy Generated (MWH) 1.357.368 0 13.241.136.0 200.971.860.0

17. -

Gross Electrical Energy Generated (MWH) 454.644.0 4.382.909.0 64.775.730.0 18.

Not Electrical Energy Generated (MWH) 440.226 0 4.245.376.0 62.474.610.0 19.

Unit Service Factor 83.1 73.2 74.2

- 20.

Unit AvailabilityFactor 83.1 73.2 74.2 21.'

Unit Capacity Factor (Using MDC NeQ 80.0 69.3 60.5 t

22.

' Unit Capacity Factor (Using DER Net) 78.6 68.1 59.4

?

23.

Unit Forced Outa0e Rate 16.9 7.0 4.8 24.

Shutdown Scheduled Over No d 6 Months (Type, Date, and duration of Each):

Refuelina and Maintenance Outaae 13. Scheduled March 1990: 8 week duration 26.

N Shut Down At End of Report Period, Estimated Date of Startup:

December 1.1989 26.

Units in Test Status (Prior to CommercialOperation):

Forecast Achieved INITLAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

^

9001190345 900108 PDR ADOCK 05000298 1'

R PDC

. g.

a

~-

i.

UNIT SHUTDOWNS AND POWER REDUCTIONS

-DOCKET NO.

050-0298 UNIT NAME Cooper Nuclear Station DATE REVISION 1 COMPLETED BY i

e REPORT MONTH November 1989 TELEPHONE (402) 825-3811 Cause & Corrective Method of Licensee 4

3 Action to Shutting Event System Component i

No.

Date Type (Hours)

Reason Down Reactor Report i Code Code Prevent Recurrence Duration 2

3 i

89-10 891112 F

0 A

5 N/A JK SC Lead reduced when Operators intention-ally tripped a Reactor Recirculation pump to recover level from loss of a feed pump. The feed pump turbine control valve pneumatic positioner l

orifice was blocked by a loose metal chip cansing t.losure of the valve on loss of motive air and an ensuing decrease in turbine speed without a pump trip. The metal chip was removed during inspection.

89-11 891125 F

121.7 A

3 89-026 LD FLT,TS An automatic reactor scram occurred due to MSIV drift and subsequent closure trip signal when an instrument air dryer post-filter element caught fire and the post-filter vessel failed, resulting in loss of instru-ment air.

The dryer temperature limit switch was determined to be faulty during instrument air system troubleshooting and testing.

'uot h the switch and post-dryer filter were replaced during subsequent maintenance.

Ine post-dryer tilter media was 4 Exhibit C - Instructions for upgraded to a high 3 Method:

1 Manual Preparation of Data Entry temperature element <

1 F: Forced 2 Reason:

S: Scheduled A - Equipment Failure (Explain)

Sheets for Licensee Event 2 - Manual Scras 3 - Automatic Scram Report (LER) File (NUREG-0161)

B - Maintenance or Test C - Refueling 4 - Continued D - Regulatory Restriction 5 - Reduced load 5 Exhibit 1 - Same Source E - Operator Training & License Examination 6 - Other F - Administrative G - Operational Error (Explain)

H - Other (Explain)