ML20005A455

From kanterella
Jump to navigation Jump to search
Proposed Tech Spec Section 2.1.3 Re Reactor Coolant Reliability & Table 3-4 Re Min Frequencies for Sampling Test
ML20005A455
Person / Time
Site: Fort Calhoun 
Issue date: 06/26/1981
From:
OMAHA PUBLIC POWER DISTRICT
To:
Shared Package
ML20005A452 List:
References
NUDOCS 8106300351
Download: ML20005A455 (2)


Text

"

O 2.0 LIMITING CONDITIONS FOR OPERATION 2.1 Reactor Coolant System (Continued) 2.1.3 Reactor Coolant Radioactivity Apolicability Applies to the radioactivity of the reactor coolant.

Objective To ensure that the reactor coolant radioactivity is maintained at a level commensurate with the occupational and public safety.

Specification (1)

The radioactivity of the reactor coolant shall be limited to:

< 2.0 pCi/gn DOSE EQUIVAIRT I-131, and a.

b.

< 100/E pCi/gm (2)

With the radioactivity of the reactor coolant > 2.0 pCi/gm DOSE EQUIVALENT I-131 but < 60 pCi/gm, operation may continue for up to 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> cumulative operating time under these circumstances does not exceed 800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> in any con-consecutive 12 month period.

(3)

With the radioactivity of the reactor coolant > 2.0 pCi/gm DOSE EQUIVALENT I-131 for more than 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> during one continuous time interval or exceeding 60 pCi/gm, be in at least HOT SHUTDOWN with Tavg < 536 F vithin 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

(h)

With the radioactivity of the reactor coolant > 100/5 pCi/gn, be in at least HOT SHUTDOWN vith Tavg < 536 F vithin 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

(5)

With the radioactivity of the reactor coolant > 2.0 pCi/gm DOSE EQUIVALENT I-131, perform the sampling and analysis requirements of items 1.(a)(2)(ii) and 1.(b)(2)(1) of Table 3 h until the radioactivity of the reactor coolant is restored to within its limits. A REPORTABLE OCCURRENCE, pursuant to Specification 5 9 2, shall be submitted to the Commission. This report shall contain the results of the radioactivity analyses together with the following infomation:

l Reactor power history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to a.

the first samples in which the limit was exceeded.

810sao035/

Amendnent 28 2-8

l TABLE 3-4 MINIMUM FREQUENCIES FOR SAMPLING TESTS Type of Measurement Sample and Analysis and Analysis Frequency 1.

Reactor Coolant (a) Power Operation (1) Gross Radioactivity 1 per 3 days (2) Isotopic Analysis for (i) 1 per 14 days DOSE FQUIVALENT I-131 (ii) 1 per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> whenever the radio-activity exceeds 2.0 pCi/gm DOSE EQUIVALENT I-131.

(iii) 1 sample between 2-8 hours following a thermal power change exceeding 15%

  • of the rated thermal

.pover within a 1-hour period.

(3) E Determination 1 per 6 months (h) Dissolved oxygen 1 per 3 days and chloride (b) Hot Standby (1) Gross Radioactitity 1 per 3 days Hot Shutdown (2) Isotopic Analysis for (i) 1 per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> (1 DOSE EQUIVALENT I-131 whenever the radio-activity exceeds 2.0 pCi/gm DOSE EQUIVALENT I-131.

(ii) 1 sample between 2-8 hours following a thermal power change exceeding 15% of the rated thermal power within a 1-hour period.

(3) Dissolved oxygen 1 per 3 days and chloride I

'+

i i

Amendment No. 28 3-18 A