ML20004B825
| ML20004B825 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 05/20/1981 |
| From: | Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML20004B821 | List: |
| References | |
| NUDOCS 8106010101 | |
| Download: ML20004B825 (71) | |
Text
4 s
.c m-m-,s.
m I
0 h
O EQUIPMENT EVALUATION REPORT BY THE OFFICE OF NUCLEAR REACTOR REGULATION EQUIPMENT QUALIFICATION BRANCH FOR TENNESSEE VALLEY AUTHORITY SEQUOYAH UNITS 1 AND 2 OOCKET NO. 50-327/328 i
e I
o PARTIAL DEVIEW EQUIPMENT EVALUATION REPORT BY THE OFFICE OF NUCLEAR REACTOR REGULATION EQUIPMENT QUALIFICATION BRANCH FOR TENNESSEE VALLEY AUTHORITY SEQUOYAH UNITS 1 AND 2 DOCKET NO. 50-327/328 ENVIRONMENTAL QUALIFICATION OF SAFETY-RELATED ELECTRICAL EQUIPMENT 3 STAFF EVALUATION The staff evaluation of the licensee's response included an onsite inspection of selected Class IE equipment, audits of environmental qualification documen-tation, and an examination of the licensee's report for completeness and acceptability.
The criteria described in the DOR guidelines and in NUREG-0588, in part, were used as a basis for the staff evaluation of the adequacy of the ifcensee's qualification program.
The NRC Office of Inspection and Enforcement performed an onsite verification inspection (during the week of December 15,1980) of selected safety-related electrical equipment.
Selected components in the emergency raw cooling water, feedwater, and component coolant water systems were inspected at Unit 1, and selected components in the reactor coolant, emergency raw cooling water, and chemical and volume control systems were inspected at Unit 2.
This inspection verified proper installation of equipment, overall interface integrity, and manufacturers' nameplate data.
The manufacturer's name and model number from the nameplate data were compared to information given in the Component Evaluation Work Sheets (CES) of the licensee's report.
The site inspection is documented for Unit 1 in report IE 50-327/80-48 and for Unit 2 in report IE 50-328/80-2G.
No significant deficiencies were noted.
For this review, the documents referenced above have been factored into the overall staff evaluation.
The NRC Office of Nuclear Reactor Regulation performed audits on August 5 and 6, 1980 and December 17-19, 1980 of environmental qualification documentatfor, and/or test data for 18 items.
No significant concerns were identified during the IE inspec-tion or the NRR audits.
3.1 Completeness of Safety-Related Equipment In accordance with IEB 79-018 and NUREG-0588, the licensee was directed to (1) establish a list of systems and equipment that are required to mitigate a LOCA and an HEL8 and (2) identify the most limiting environmental conditions the equipment may be exposed to and still be required to perform its safety function.
l The staff developed a generic master list based upon a review of plant safety analyses and emergency procedures. The instrumentation selected includes param-eters to monitor overall plant performance as well as to monitor the performance of the systems on the list. The systems list was established on the basis of the functions that must be performed for accident mitigation (without regard to location of equipment relative to hostile environments).
The list of safety-related systems provided by the licensee was reviewed against the staff-developed master list...
L
a u
l Based upon information in the licensee's submittal, the equipment location references, ana in some cases subsequent conversations with the licensee, the staff has verified and determined that the systems included in the licensee's submittal are those required to achieve or support:
(1) emergency reactor shut-down, (2) containment isolation, (3) reactor core cooling, (4) containment heat removal, (5) core residual heat removal, and (6) prevention of significant release of radioactive material to the environment.
However, the licensee did not include i
the safeguards actuation system, the pressurizer spray system and the accumula-tors. The licensee should address or justify the omission of these systems.
The staff therefore concludes that the systems identified by the licensee (listed in Appendix D) are acceptable, with the exceptions of those items noted above and discussed in Section 5 of this report.
Display instrumentation which provides information for the reactor operators to aid them in the safe handling of the plant was not specifically identified by the licensee.
A complete list of all display instrumentation mentioned in the LOCA and HELB emergency procedures must be provided.
Equipment qualification information in the form of summary sheets should be provided for all components of the display instrumentation exposed to harsh environments.
Instrumentation which is not considered to be safety related but which is mentioned in the emer-gency procedure should appear on the list.
For these instruments, (1) justifica-tion should be provided for not considering the instrument safety related and (2) assurance should be provided that its subsequent failure will not mislead the operator or adversely affect the mitigation of the consequences of the accident.
The environmental qualification of post-accident sampling and monitoring and radiation monitoring equipment is closely related to the review of the TMI lessons-learned modifications and will be performed in conjunction with that review.
l The licensee identified 1173 items of equipment which were assessed by the staff.
3.2 Service Conditions Commission Memorandum and Order CLI-80-21 requires that the 00R guidelines and the "For Comment" NUREG-0588 are to be used as the criteria for establishing the adequacy of the safety related electrical equipment environmental qualifi-cation program.
These documents provide the option of establishing a bounding pressure and temperature condition based on plant-specific analysis identified in the licensee's Final Safety Analysis Report (FSAR) or based on generic profiles using the methods identified in these documents.
On this basis, the staff has assumed, unless otherwise noted, that the analysis for developing the environmental envelopes for Sequoyah Units 1 and 2--relative to the temperature, pressure, and the containment spray caustics--has been performed in accordance with the requirements stated above. The staff has reviewed the qualification documentation to ensure that the qualification specifications envelope the conditions esta'Ji!shed by the licensee.
In addition, the staff assumed, and requires the licensee to verify, that the containment spray system is not subjected to a disabling single-component failure.
Equipment submergence has also been addressed where the possibility exists that flooding of equipment may result from HEL8s..
l 3.3 Temperature, Pressure, and Humidity Conditions Inside Containment The licensee has provided the results of accident analyses as follows:
Max. Temp. (*F)
Max. Press. (psig)
LOCA Lower Compartment 244 12.0 Upper Compartment 170 12.0 MSLB Lower Compartment 327 10.8 Upper Compartment 140 10.8 The licensee's minimum temperature profile for qualification purposes in the lower compartment is based on an MSLB analysis and is acceptable for use because there is reasonable assurance under both MSLB and LOCA conditions that the actual temperatures and pressures for the postulated accidents will not exceed the environmental zone.
However, the licensee's MSLB temperature / pressure profile does not extend beyond 1000 seconds.
The staff requires that the licensee extend the profile to at least 105 seconds.
The licensee's minimum temperature profile for qualification purposes in the upper compartment is based on the LOCA temperature and is acceptable to the staff.
3.4 Temperature, Pressure, and Humidity Conditions Outside Containment The licensee has provided the temperature, pressure, humidity, and applicable environment associated with an HELB outside containment.
The following areas outside containment have been addressed:
(1) Auxiliary building (2) Main steam valve vaults The staff has verified that the parameters identified by the licensee for the MSLB are ac:eptable.
3.5 Submergence The maximum submergence levels have been established and assessed by the licensee.
Unless otherwise noted, the staff assumed for this review that the methodology employed by the licensee is in accordance with the appropriate criteria as estab-lished by Commission Memorandum and Order CLI-80-21.
The licensee's value for maximum submergence is 13.2 ft.
In this regard, the Sequoyah design is such that no safety-related equipment is subjected to submergence.
1.
0 4
)
3.6 Chemical Spray The licensee's FSAR value for the chemical concentration is 2000 ppm boric acid solution; the exact volume percent used by the vendor for qualification testing should be verified by the licensee.
Thcrefore, for the purpose of this review, the effects of chemical spray will be considered unresolved.
The staff will review the licensee's response when it is submitted and discuss the resolution in a supplemental report.
3.7 Aging NUREG-0588, Category II, delineates two aging program requirements.
Valve operators committed to IEEE Standard 382-1972 and motors committed to IEEE Stancard 334-1971 must meet the Category I requirements of the NUREG.
This requires the establishment of a qualified life, with maintenance / replacement schedules based on the findings.
All other equipment must be subjected to an aging program which identifies aging susceptible materials within the component.
Additionally, the staff requires that the licensee:
(1) establish an ongoing program to review surveillance and maintenance records to identify potential age-related degradations (2) establish component maintenance and replacement schedules which include considerations of aging characteristics of the installed components The licensee identified a number of equipment items for which a specified quali-fled life was established (for example, 5 years,15 years, or 40 years).
In its assessment of these submittals, the staff did not review the adequacy of the methodology nor the basis used to arrive at these values; the staff has assumed that the established values are based on state-of-the-art technology and are acceptable.
For this review, however, the staff requires that the licensee submit supple-mental information to verify and identify the degree of conformance to the above requirements.
The response should include all the equipment identified as required to maintain functional operability in harsh environments.
The licensee indicated that this phase of the response is outstanding and t' at the review is in progress.
The staff will review the licensee's response when it is submitted and discuss its evaluation in a supplemental report.
3.8 Radiation (Inside and Outside Containment)
The licensee has provided values for the radiation levels postulated to exist following a LOCA.
The application and methodology employed to determine these values were presented to the licensee as part of the NRC staff criteria contained in the 00R guidelines, in NUREG-0588, and in the guidance provided in IEB-79-018, Supplement 2.
Therefore, for this review, the staff has assumed that, unless otherwise noted, the values provided have been determined in accordance with the prescribed criteria.
The staff review determined that the values to which equipment was qualified enveloped the requirements identified by the licensee.,
i
--n-
-- - -, -, - - - - - ~ - - - -
-e-~-
The value required by the licensee inside containment is an integrated dose of 5 x 107 to 1 x 108 rads.
This value envelopes the minimum requirements of NUREG-0588 and is therefore acceptable.
The required value outside containment of 1 x 108 has been used by the licensee to specify limiting radiation levels for areas near RHR pumps within the auxiliary building.
This value appears to consider the radiation levels influenced by the source term methodology associated with post-LOCA recircula-tion fluid lines.
4 QUALIFICATION OF EQUIPMENT The following subsections present the staff's assessment, based on the licensee's submittal and staff audits, of the qualification status of safety-related elec-trical equipment.
The staff has separated the safety-related equipment into three categories:
(1) equipment requiring immediate corrective action, (2) equipment requiring additional qualification information and/or corrective action, and (3) equip-ment considered acceptable if the staff's concern identified in Section 3.7 is satisfactorily resolved.
In its assessment of the licensee's submittal, the NRC staff did not review the methodology employed to determine the values established by the licensee.
However, in reviewing the data sheets, the staff made a determination as to the stated conditions presented by the licensee.
Additionally, the staff has not completed its review of supporting documentation referenced by the licen-see (for example, test reports).
It is expected that when the review of test reports is complete, the environmental qualification data bank established by the staff will provide the means to cross reference each supporting document to the referencing licensee.
If supporting documents are found to be unacceptable, the licensee will be required to take additional corrective actions to either establish qualifica-tion or replace the item (s) of concern.
This effort will begin in early 1981.
An appendix for each subsection of this report provides a list of equipment for which additional information and/or corrective action is required.
Where appropriate, a reference is provided in the appendices to identify deficiencies.
It should be noted, as in the Commission Memorandum and Order, that the defi-ciencies identified do not necessarily mean that equipment is unqualified.
However, they are cause for concern and may require further case-by-case evalua-tion.
4.1 Equipment Requiring Immediate Corrective Action Appendix A contains the current list of items satisfactorily addressed by TVA. -
n 4.2 Equipment Requiring '.dditional Information and/or Corrective Action Appendix B identifies equipment in this category, including a tabulation of deficiencies. The deficiencies are noted by a letter relating to the legend (identified below), indicating that the information provided is not sufficient for the qualification parameter or condition.
Legend radiation R
T temperature QT qualification time RT required time P
pressure humidity H
chemical spray CS material-aging evaluation; replacement schedule; ongoing equipment A
surveillance S
- submergence margin M
I
- HELB evaluation outside containment not completed QM qualification method RPN equipment relocation or replacement; adequate schedule not providid EXN - exempted equipment justification inadequate SEN - separate-effects qualification justification inadequate QI - qualification information being developed RPS - equipment relocation or replacement schedule provided As noted in Section 4, these deficiencies do not necessarily mean that the equipment is unquali'ied. However, the deficiencies are cause for concern and require further case-by-case evaluation.
The staff has determined that an acceptable basis to exempt equipment from qualification, in whole or part, can be established provided the following can be established and verified by the licensee:
(1) Equipment does not perform essential safety functions in the harsh environ-ment, and equipment failure in the harsh environment will not impact safety-related fur.ctions or mislead an operator.
(2a) Equipment performs its furction before its exposure to the harsh environ-ment, and the adequacy for the time margin provided is adequately justified, and (2b) Subsequent failure of the equipment as a result of the harsh environment does not degrade other safety functions or mislead the operator.
(3) The safety-related function can be accomplished by some other designated equipment that has been adequately qualified and satisfies the single-failure criterion. _. -
(4) Equipment will not be subjected to a harsh environment as a result of the postulated accident.
The licensee is, therefore, required to supplement the information presented by providing resolutions to the deficiencies identified; these resolutions should include a description of the corrective action, schedules for its completion (as applicable), and so forth. The staff will review the licensee's response, when it is submitted, and discuss the resolution in a supplemental report.
It should be noted that in cases where testing is being conducted, a condition may arise which results in a determination by the licensee that the equipment does not satisfy the qualification test requirements.
For that equipment, the licensee will be required to provide the proposed corrective action, on a timely basis, to ensure that qualification can be established by June 30, 1982.
4.3 Equipment Considered Acceptable or Conditig.aally Acceptable Based on the staff review of the licensee's submittal, the staff identified the equipment in Appendix C as (1) acceptable on the basis that the qualifica-tion program adequately enveloped the specific environmental plant parameters, or (2) conditionally acceptable subject to tre satisfactory resolution of the staff concern identified in Section 3.7.
For the equipmert identified as conditionally acceptable, the staff determined that the licensee did not (1) complete and document the equipment material review and evaluation to ensure that lio known materials susceptible to degradation because of aging have been used, (2) establish an ongoing program to review the plant surveillance and mainte-nance records in order to identify equipment degradation which may be age related, and/or (3) propose a maintenance program and replacement schedule for equipment identified in item 1 or equipment that is qualified for less than the life of the plant.
The licensee is, therefore, required to supplement the information presented for equipment in this category before full acceptance of this equipment can be established.
The staff will review the licensee's response when it is submitted and discuss the resolution in a supplemental report.
5 DEFERRED REQUIREMENTS IEB 79-018, Supplement 3 has relaxed the time constraints for the submission of the information associated with cold shutdown equipment and TMI lessons-learned modifications.
The staff has required that this information be provided by February 1,1981.
The staff will provide a supplemental safety evaluation addressing these concerns.
.y.
.J
.a O
APPENDIX A Equipment Requiring Immediate Corrective Action (Category 4.1)
LEGEND:
Designation for Deficiency R - Radiation T - Temperature QT - Qualification Time RT - Required Time P - Pressure H - Humidity CS - Chemical spray A - Material aging evaluation, replacement schedule, ongoing equipment surveillance S - Submergence M - Margin I - HELB evaluation outside containment not completed QM - Qualification method RPN - Equipment relocation or replacement, adequate schedule not provided EXN - Exempted equipment justification inadequate SEN - Separate effects qualification justification inadequate QI - Qualification information being developed RPS - Equipment relocation or replacement schedule provided Equipment Description Manufacturer Component No.
Deficiency
- Solenoid Valve ASCO FSV-30-46A R
- Solenoid Valve ASCO FSV-30-47A R
- Solenoid Valve ASCO FSV-30-48A R
- Solenoid Val,a ASCO FSV-32-110A R
- Solenoid Valve ASCO FSV-32-1108 R
- Solenoid Valve ASCO FSV-32-111A R
- Solenoid Valve ASCO FSV-32-1118 R
- Handswitch Cutler Hammer 1-HS-1-15B A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-1-168 A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-1-17B A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-1-188 A,P,T,H,R,QT A-1
APPENDIX A (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
- Handswitch Cutler-Hamer 1-HS-3-338 A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-3-478 A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-3-878 A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-3-1008 A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-72-408 A,P,T,H,R,QT
- Handswitch Cutler-Hammer 1-HS-72-418 A,P,T,H,R,QT t* Level Transmitter Foxboro LT-3-43 T,R t* Level Transmitter Foxboro LT-3-56 T,R t* Level Transmitter Foxboro LT-3-98 T,R t* Level Transmitter Foxboro LT-3-111 T,R Corrective Action
- Note:
Equipment replaced with environmentally qualified units.
- Nota:
These handswitches have been removed from service by disconnecting and eliminating their function from the control circuit.
tSee Attachment 1.
Foxboro Letter (3/12/81) " Potential Deficiency Affecting Foxboro Transmitters," For Corrective Action.
l l
l l
i i
A-2
APPENDIX B Equipment Requiring Additional Information and/or Corrective Action (Category 4.2)
LEGEND:
Designation for Deficiency R - Radiation T - Temperature QT - Qualification Time RT - Required Time P - Pressure H - Humidity C5 - Chemical spray A - Material aging evaluation, replacement schedule, ongoing equipment surveillance S - Submergence M - Margin I - HELB evaluation outside containment not completed QM - Qualification method RPN - Equipment relocation or replacement, adequate schedule not provided EXN - Exempted equipment justification inadequate SEN - Separate effects qualification justification inadequate QI - Qualification informaticn being developed RPS - Equipment relocation or replacement schedule provided Equipment Description Manufacturer Component No.
Deficiency tTransmitter Foxboro LT-3-56 QT,A,M tTransmitter Foxboro LT-3-43 QT,A,M tTransmitter Foxboro LT-3-98 QT,A,M
@ Solenoid Valve ASCO FSV-30-279 R,T,QT,P,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-280 R,T,QT,P,H,A,M,QM,QI Solanoid Valve ASCO FSV-30-157A R,T,QT,P,H,A,M,QM,QI
- NOTE:
Items for which supporting environmental qualification documentation was audited by NRR.
tSce Attachment 1:
Foxboro Letter (3/12/81) " Potential Deficiency Affecting Foxboro Transmitters," For Corrective Action.
@ Item unique to Unit 1 or shared by Units 1 and 2.
$ Items Unique to Unit 2.
B-1
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve
'ASCO FSV-30-21 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-22 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-90-108 R,T,QT,P,H,A,CS,M, QM,QI Solenoid Valve ASCO FSV-90-109 R,T,QT,P,H,A,CS,M, QM,QI Solenoid Valve ASCO FSV-90-110 R,T,QT,P,H,A,CS,M, QM,QI Solenoid Valve ASCO FSV-90-114 R,T,QT,P,H,A,CS,M, QM,QI Solenoid Valve ASCO FSV-90-115 R,T,QT,P,H,A,CS,M, QM,QI Solenoid Valve ASCO FSV-90-116 R,T,QT,P,H,A,CS,M, QM,QI Solenoid Valve ASCO FSV-81-12 R,T,QT,P,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-70-85 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-62-77 R,T,QT,P,H,A,M,QM,QI
- Solenoid Valve ASCO FSV-62-70 QT,A,M Solenoid Valve ASCO FSV-62-69 QT,A,M Solenoid Valve ASCO FSV-62-72 QT,A,M Solenoid Valve ASCO FSV-62-73 QT,A,M Solenoid Valve ASCO FSV-62-74 QT,A,M Solenoid Valve ASCO FSV-63-71 QT,A,M Solenoid Valve ASCO FSV-62-128 QT,A,M Solenoid Valve ASCO FSV-1-181 CS,R,T,QT,P,H,A,M, QM,QI Solenoid Valve ASCO FSV-1-182 CS,R,T,QT,P,H,A,M, QM,QI B-2
t O
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve ASCO FSV-1-183 CS,R,T,QT,P,H,A,M, QM,QI Solenoid Valve ASCO FSV-1-184 CS,R,T,QT,P,H,A,M, QM,QI Solenoid Valve ASCO FSV-63-38 QT,A,M Solenoid Valve ASCO FSV-63-41 QT,A,M Solenoid Valve ASCO FSV-63-42 QT,A,M
- Solenoid Valve ASCO FSV-63-84 QT,A,M Solenoid Valve ASCO FSV-313-223 R,T,QT,P,H,A,M,CS, RPS Solenoid Valve ASCO FSV-314-225 R,T,QT,P,H,A,M,CS, QM,RPS Solenoid Valve ASCO FSV-313-230 R,T,QT,P,H,A,M,CS, QM,RPS Solenoid Valve ASCO FSV-313-232 R,T,QT,P,H,A,M,CS, QM,RPS Solenoid Valve ASCO FSV-77-127 R,T,QT,P,H,A,M,CS, QM,QI
@ Solenoid Valve ASCO FSV-30-298 R,T,QT,P,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-299 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-3 R,T,QT,P,H,A,M,QM,RPS i
l Solenoid Valve ASCO FSV-30-6 R,T,QT,P,H,A,M,QM,RPS Solenoid Valve ASCO FSV-30-60 R,T,QT,P,H,A,M,QM,RPS Solenoid Valve ASCO FSV-30-69 R,T,QT,P,H,A,M,QM,RPS Solenoid Valve ASCO FSV-30-146A R,T,QT,P,H,A,M,QM,RPN Solenoid Valve ASCO FSV-30-1468 R,T,QT,P,H,A,M,QM,RPN l
Solenoid Valve ASCO FSV-65-10 R,T,QT,P,H,A,M,QM,RPN
@ Solenoid Valve ASCO FSV-67-162 R,T,QT,P,H,A,M,QM,QI B-3
{
l
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
@ Solenoid Valve ASCO FSV-67-164 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-168 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-170 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-176 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-182 R,T,QT,P,H,A M,QM,QI Solenoid Valve ASCO FSV-67-184 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-186 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-188 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-190 R,T,QT,P,H,A M,QM,QI
@ Solenoid Valve ASCO FSV-67-213 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-215 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-354 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-356 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-336 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-338 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-344 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-346 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-348 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-350 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-67-352 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-62-143 QT,A,M Solenoid Valve ASCO FSV-62-140A R,T,QT,P,H,A,M,0M,QI Solenoid Valve ASCO FSV-62-1408 R,T,QT,P,H,A,M,QM,QI Solenoid Valve ASCO FSV-62-144 R,T,QT,P,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-313-305 R,T,QT,P,H,A,M,QM,QI B-4 l
l
?
C l
1
~
i APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
@ Solenoid Valve ASCO FSV-313-340 R,T,QT,P,H,A,M,QM,QI Solenoid Valve AVC0 FSV-30-8 R,T,i!,P,QT,CS, A,M,QM,QI Solenoid Valve AVC0 FSV-30-10 R,T,H,P,QT,CS,A,M,QM,QI
- Solenoid Valve AVC0 FSV-30-50 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-52 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-15 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-17 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-40 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-56 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-20 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-58 R,T,H,P,QT,CS,A,M,QM,QI Solenoid Valve AVC0 FSV-30-2 R,T,H,P,QT,A,M,QM,QI Solenoid Valve AVC0 FSV-30-5 R,T,H,P,QT,A,M,QM,QI Solenoid Valve AVC0 FSV-30-61 R,T,H,P,QT,A,M,Qil,QI Solenoid Valve AVC0 FSV-30-62 R,T,H,P,QT,A,M,QM,QI Solenoid Valve AVC0 FSV-30-7 R,T,H,P,QT,A,M,QM,QI Solenoid Valve AVC0 FSV-30-28A QT,A,M Solenoid Valve AVC0 FSV-30-47A R,T,H,P,QT,A,M,QM Solenoid Valve AVC0 FSV-30-51 R,T,H,P,QT,A,M,QM,QI Motor Operated Valve Limitorque FCV-63-152 QT,A,M Motor Operated Valve Limitorque FCV-63-153 QT,A,M Motor Operated Valve Limitorque FCV-63-156 R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-63-157 R,T,QT,P,H,A,M,QM,QI B-5
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Valve Limitorque FCV-63-38 QT,A,M Motor Operated Valve Limitorque FCV-63-41 QT,A,M Motor Operated Valve Limitorque FCV-63-42 QT,A,M Motor Operated Valve Limitorque FCV-63-84 R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-62-90 QT,A,M Motor Operated Valve Limitorque FCV-62-91 QT,A,M Motor Operated Valve Limitorque FCV-63-22 QT,A,M Motor Operated Valve Limitorque FCV-63-25 QT,A,M Motor Operated Valve Limitorque FCV-63-26 QT,A,M Motor Operated Valve Limitorque FCV-63-39 QT,A,M Motor Operated Valve Limitorque FCV-63-40 QT,A,M t
(
l Motor Operated t
Valve Limitorque FCV-63-93 QT,A,M Motor Operated Valve Limitorque FCV-63-94 QT,A,M Motor Operated Valve Limitorque FCV-63-1 QT,A,M Motor Operated Valve Limitorque FCV-63-3 QT,A,M l
Motor Operated l
Valve Limitorque FCV-63-5 QT,A,M l
l B-6
s e
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Valve Limitorque FCV-63-6 QT,A,M Motor Operated Valve Limitorque FCV-63-7 QT,A,M Motor Operated Valve Limitorque FCV-63-8 QT,A,M Motor Operated Valve Limitorque FCV-63-11 QT,A M Motor Operated Valve Limitorque FCV-74-12 R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-74-24
.R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-62-132 R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-62-133 R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-62-135 QT,A,M Motor Operated Valve Limitorque FCV-62-136 QT,A,M Motor Operated Valve Limitorque FCV-62-138 QT,A,M
@ Motor Operated Valve Limitorque FCV-74-3 QT,A,M
@ Motor Operated Valve Limitorque FCV-74-21 QT,A,M Motor Operated Valve Limitorque FCV-63-4 QT,A,M Motor Operated Valve Limitorque FCV-63-175 QT,A,M Motor Operated Valve Limitorque FCV-63-47 QT,A,M B-7 o.
APPENDIX d (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor 'perated Valve Limitorque FCV-63-48 QT,A,M
- Motor Operated Valve Limitorque FCV-63-72 QT,A,M Motor Operated Valve Limitorque FCV-63-73 QT,A,M Motor Operated Valve Limitorque FCV-62-61 QT, A,;l
- Motor Operated Valve Limitorque FCV-63-67 QT,A,M Motor Operated Valve Limitorque FCV-63-80 QT,A,M Motor Operated Valve Limitorque FCV-63-98 QT,A,M Motor Operated Valve Limitorque FCV-63-118 QT,A,M Motor Operated Valve Limitorque FCV-63-172 QT,A,M Motor Operated Valve Limitorque FCV-1-15 T,A,QM,M,P,QT,QI Motor Operated Valve Limitorque FCV-1-16 T,A,QM,M,P,QT,QI Motor Operated Valve Limitarque FCV-1-17 T,A,QM,M,P,QT,QI Motor Operated Valve Limitorque FCV-1-18 T,A,QM,M,P,QT,QI Motor Operated Valve Limitorque FCV-70-89 A,M,H,CS,QT,T,P,QM Motor Operated Valve Limitorque FCV-70-87 A,M,H,CS,QT,T,P,QM Motor Operated i
Valve Limitorque FCV-70-183 A,M,QT,QI l
B-8 l
o APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Valve Limitorque FCV-70-90 A,M,QT,QI Motor Operated Valve Limitorque FCV-70-133 A,M,QT,QI Motor Operated Valve Limitorque FCV-70-134 A,M,QT,QI Motor Operated Valve Limitorque FCV-62-138 R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-62-9R R,T,QT,P,H,A,M,QM,QI Motor Operated Valve Limitorque FCV-62-99 R,T,QT,P,H,A,M.QM,QI Motor Operated Valve Limitorque FCV-3-116A A,M,QT Motor Operated Valve Limitorque FCV-3-1168 A,M,QT Motor Operated Valve Limitorque FCV-3-126A A,M,QT Motor Operated Valve Limitorque FCV-3-1268 A,M,QT Motor Operated Valve Limitorque FCV-67-87 T,A,M,QM,CS,H Motor Operated Valve Limitorque FCV-67-95 T,A,M,QM,CS,H Motor Operated Valve Limitorque FCV-67-103 T,A,M,QM,CS,H Motor Operated Valve Limitorque FCV-67-111 T,A,M,QM,CS,H Motor Operated Valve Limitorque FCV-67-295 T,A,M,QM,CS,H Motor Operated Valve Limitorque FCV-67-296 T,A,M,QM,CS,H l
B-9 i
(
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Valve Limitorque FCV-67-297 T,A,M,QM,CS,H Motor Operated Valve Limitorque FCV-67-298 T,A,M,QM,CS,H Motor Operated Valve Limitorque FCV-72-13 A,M,QT Motor Operated Valve Limitorque FCV-72-34 A,M,QT Motor Operated Valve Limitorque FCV-3-33 T,A,M,QM Motor Operated Valve Limitorque FCV-3-47 T,A,M,QM Motor Operated Valve Limitorque FCV-3-87 T,A,M,QM Motor Operated Valve Limitorque FCV-3-100 T,A,M,QM,P,QI Motor Operated Valve Limitorque FCV-72-2 QM,R,A,M,QI Motor Operated Valve Limitorque FCV-72-39 QM,R,A,M l
Motor Operated Valve Limitorque FCV-72-20 QM,R,A,M Motor Operated Valve Limitorque FCV-72-23 QM,R,A,M Motor Operated l
Valve Limitorque FCV-72-21 QM,R,A,M l
l Motor Operated i
Valve Limitorque FCV-72-40 QM,R,A,M Motor Operated Valve Limitorque FCV-72-41 QM,R,A,M Motor Operated Valve Limitorque FCV-74-33 QT,A,M i
l l
B-10
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Valve Limitorque FCV-74-35 QT,A,M Motor Operated Valve Linkbelt FCV-67-123 QM,A,M,QT Motor Operated Valve Linkbelt FCV-67-125 QM,A,M,QT Motnr Operated Valve Linkbelt FCV-67-146 QM,A,M,QT
@* Motor Operated Valve Linkbelt FCV-67-151 QM,A,M,QT
@ Motor Operated Valve Linkbelt FCV-67-152 QM,A,M,QT Motor Operated Valve Linkbelt FCV-67-127 QM,A,M,QT Motor Operated Valve Linkbelt FCV-67-128 QM,A,M,QT Motor Operated Valve Linkbelt FCV-67-147 QM,A,M,QT
@ Motor Operated Valve Linkbelt FCV-67-205 QM,A,M,QT
@ Motor Operated Valve Linkbelt FCV-67-208 QM,A,M,QT
@ Motor Operated Valve Linkbelt FCV-67-233 QM,A,M,QT Motor Operated Valve Linkbelt FCV-67-81 QM,A.M,QT Motor Operated Valve Linkbelt FCV-67-82 QM,A,M,QT Motor Operated Valve Linkbelt FCV-67-126 QM,A,M,QT Motor Operated Valve Linkbelt FCV-67-124 QM,A,M,QT B-11
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficpncy Motor Operated Valve Linkbelt FCV-70-2 QM,A,M,QT
- Motor Operated Valve Linkbelt FCV-70-3 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-4 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-8 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-9 QM,A,M,QT Motor operated Valve Linkbelt FCV-70-10 QM,A,M,QT
@ Motor Operated Valve Linkbelt FCV-70-11 QM,A,M,QT
@ Motor Operated Valve Linkbelt FCV-70-12 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-13 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-14 QM,A,M Motor Operated l
Valve Linkbelt FCV-70-15 QM,A,M Motor Operated Valve Linkbelt FCV-70-16 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-18 QM,4..S Motor Operated Valve Linkbelt FCV-70-22 QM..,M,QT Motor Operated Valve Linkbelt FCV-70-23 QM,A,M,QT l
Motor Operated Valve Linkbelt FCV-70-25 QM,A,M,QT l
B-12 l
c
0 APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Valve Linkbelt FCV-70-26 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-27 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-28 QM,A,M Motor Operated Valve Linkbelt FCV-70-29 QM,A,M Motor Operated Valve Linkbelt FCV-70-34 QM,A,M,QT Motor Operated Valve Linkbelt FCV-70-39 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-40 A,QM,M
@ Motor Ope ated Valve Linkbelt FCV-70-41 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-64 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-74 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-75 A,QM,M Motor Operated
. Valve Linkbelt FCV-70-76 A,QM,M Motor Operated Valve Linkbelt FCV-70-78 A,QM,M
@ Motor Operated Valve Linkbelt FCV-70-111 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-153 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-156 A,QM,M,QT B-13
?
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Valve Linkbelt FCV-70-168 A,QM,M,QT
@ Motor Operated Valve Linkbelt FCV-70-193 A,QM,M,QT
@ Motor Operated Valve Linkbelt FCV-70-194 A,QM,M,QT Motor Operated Valve Linkbalt FCV-70-195 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-196 A,QM,M,QT
@ Motor Operated Valve Linkbelt FCV-70-197 A,QM,M,QT
@ Motor Operated Valve Linkbelt FCV-70-190 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-92 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-139 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-140 A,QM,M,QT Motor Operated Valve Linkbelt FCV-70-143 A,QM,M,QT
@* Flow Switch Dwyr:
FS-30-146 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-157 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-194 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-195 R,T,QT,P,H,A,M,(M,QI Fiew Switch Dwyer FS-30-196 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-197 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-200 R,T,QT,P,H,A,M,RM,QI Flow Switch Dwyer FS-30-202 R,T,QT,P,H,A,M,QM,QI B-14
APPENDIX B (cont'd)
Equipment Description Manufacturer Comoonent No.
Deficiency Flow Switch Dwyer FS-30-184 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-185 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-190 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-191 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-192 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-193 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-186 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-187 R,T,QT,P,E, A,M,QM,QI Flaa Switch Dwyer FS-30-201 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-20-194 R,T,QT,P,H,A,M,QM,QI Flow Switch Dwyer FS-30-195 R,T,QT,P,H,A,M,QM,QI
@ Pressure Differential Indication Switch Dwyer PDIS-30-148 R,T,QT,P,H,A,M,QM,QI
@ Pressure 1
Differential Indication Switch Dwyer PDIS-30-149 R,T,QT,P,H,A,M,QM,QI
@ Pressure Switch Custom Component PS-32-62 R,T,QT,P,H,A,M,QM,QI
@ Pressure Switch Custom Component PS-32-88 R,T,QT,P,H,A,M,QM,QI
@ Pressure Switch Custom Component PS-32-82 R,T,QT,P,H,A,M,QM,QI
@ Pressure Switch Custom Component PS-32-85 R,T,QT,P,H,A,M,QM,QI I
@ Pressure Switch Custom Component PS-70-209 R,T,QT,P,H,A,M,QM,QI
@ Pressure Switch Custom Component PS-70-210 R,T,QT,P,H,A,M,QM,QI l
Temperature Switch PENN TS-30-184 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-185 R,T,QT,P,H,A,M,QM,QI
@ Temperature Switch PENN TS-30-190 R,T,QT,P,H,A,M,QM,QI
@ Temperature Switch PENN TS-30-191 R,T,QT,P,H,A,M,QM,QI 8-15 41
---+~-w'?
e
+ ~, - -
---e-.---re
--e----
~
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
@ Temperature Switch PENN TS-30-192 R,T,QT,P,H,A,M,QM,QI
@ Temperature Switch PENN TS-30-193 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-207 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-175 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-176 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-177 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-178 R,T,QT,P H,A,M,QM,QI Temperature Svitch PENN TS-30-179 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-180 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-182 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-183 R,T,QT,P,H,A,M,QM,QI Temperature Switch PEN!1 TS-30-194 R,T,QT,P,H,A,M,QM,QI Temperature Switch
'ENN TS-30-195 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-196 R,T,QT,P,H,A M,QM,QI Temperature Swi+.ch PENN TS-30-197 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-186 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-187 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-201 R,T,QT,P,H,A,M,QM,QI Temperature Switch PENN TS-30-202 R,T,QT,P,H,A,M,QM,QI
@ Temperature Switch Honeywell TS-30-103A R,T,QT,P,H,A,M,QM,QI Temperature Switch Honeywell TS-74-43 RPS Temperature Switch Honeywell TS-74-44 RPS Temperature Switch Honeywell TS-74-45 RPS Temperature Switch Honeywell TS-74-46 RPS
@ Temperature Switch FENWAL TS-30-103 R,T,QT,P,H,A,M,QM,QI B-16
i APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Temperature Switch FENWAL TS-30-214 R,T,QT,P,H,A,M,QM,QI Temperature Switch FENWAL TSI-17A R,T,QT,P,H,A,M,QM,QI Temperature Switch FENWAL TSI-17B R,T,QT,P,H,A,M,QM,QI Temperature Switch FENWAL TSI-18A R,T,QT.P,H,A,M,QM,QI Temperature Switch FENWAL TSI-188 R,T,QT,P,H,A,M,QM,QI
@* Transfer Switch Electro-Switch XS-46-57 QM,A Flow Switch Barton FIS-67-206 R,T,QT,P,H,A,M,QM,QI Flow Switch Barton FIS-67-209 R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-55A/B R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-44E/F R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-25A/B R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-25C/D R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-31A/B R,T,QT,P,H,A,M,QM,QI 0 Flow Switch Barton FIS-65-55C/D R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-44A/B R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-44C/D R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-2EE/F R,T,QT,P,H,A,M,QM,QI
@ Flow Switch Barton FIS-65-31C/D R,T,QT,P,H,A,M,QM,QI
@ Pressure Switch Barton PDIS-313-305 R,T,QT,P,H,A,M,QM,QI
@ Pressure Switch Barton PDIS-313-340 R,T,QT,P,H,A,M,QM,QI Modifier ITT Conoflow FM-30-148 R,T,QT,P,H,A,M,QM,QI Modifier Transmation FM-30-148A R,T,QT,P,H,A,M,QM,QI Modifier Transmation FM-30-149 R,T,QT,P,H,A,M,QM,QI Modifier Transmation FM-30-149A R,T,QT,P,H,A,M,QM,QI B-17
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency tTransmitter Foxboro PT-1-28 A,R tTransmitter Foxboro PT-1-278 A,R tTransmitter Foxboro PT-1-9A R,T,QT,P,H,A,M,QM,QI tTransmitter Foxboro PT-1-20A R,T,QT,P,H,A,M,QM,QI tTransmitter Foxboro PT-1-20B R,T,QT,P,H,A,M,QM,QI t* Transmitter Fo> boro LT-3-148 A,QI,R iTransmitter Foxboro LT-3-156 A,QI,R tTransmittar Foxboro LT-3-164 A,QI,R tTransmitter Foxboro LT-3-171 A,QI,R tTransmitter Foxboro LT-3-173 A,QI,R l
tTransmitter Foxboro LT-3-174 A,QI,R tTransmitter Foxboro LT-3-175 A,QI,R tTransmitter Foxboro LT-3-172 A,QI,R Flow Transmitter Bailey FT-72-13 R,T,QT,P,H,A,M,QM,QI I
Flow Transmitter Bailey FT-72-34 R,T,QT,P,H,A,M,QM,QI l
Flow Transmitter Bailey FT-70-81A R,T,QT,P,H,A,M,QM,QI Flow Transmitter Bailey FT-70-81B R,T,QT,P,H,A,M,QM,QI Flow Transmitter Bailey FT-70-81D R,T,QT,P,H,A,M,QM,QI tPressure Foxboro PDT-65-80 R,T,0T,P,H,A,M,QM,QI Transmitter tPressure Foxboro PDT-65-82 R,T,QT,P,H,A,M,QM,QI Transmitter tPressure Foxboro PDT-65-90 R,T,QT,P,H,A,M,QM,QI Transmitter tPressure Foxboro PDT-65-97 R,T,QT,P,H,A,M,QM,QI Transmitter B-18
y.
~.
se*
0 i
APPENDIX 8 (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Pressure Barton PT-68-320 T,QT,A,M,QM Transmitter Pressure Barton PT-68-335 T,QT,A,M,QM Transmitter Pressure Barton PT-68-339 T,QT,4,M,QM Transmitter Pressure Barton PT-68-66 T,Q T, A,M,QM Transmitter Flow Transmitter Barton FT-1-3A&38 A,M Flow Transmitter Barton FT-1-10A&B A,M Flow Transmitter Barton FT-1-21A&B A,M Flow Transmitter Barton FT-1-28A&B A,M Level Transmitter Barton LT-3-38 R,T,QT,P,H,A,M,QM,QI, CS Level Transmitter Barton LT-3-39 R,T,QT,P,H,A,M,QM,QI, CS Level Transmitter Barton LT-3-42 R,T,QT,P,H,A,M,QM,QI, CS Level Transmitter Barton LT-3-51 R,T,QT,P,H,A,M,QM,QI, CS l
Level Transmitter Barton LT-3-52 R,T,QT,P,H,A,M,QM,QI, t
l CS Level Transmitter Barton LT-3-93 T,QT,A,M,QM B-19
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Level Transmitter Barton LT-3-94 T,QT,A,M,QM Level Transmitter Barton LT-3-111 T,QT,A,M,QM Level Transmitter Barton LT-3-97 T,QT,A,H QM Level Transmitter Barton LT-3-106 T,QT,A,M,QM Level Transmitter Barton LT-3-107 T,QT,A,M,QM Level Transmitter Barton LT-3-110 T,QT,A,M,QM Level Transmitter Barton LT-3-111 R,T,QT,P,H,A,M,QM,QI CS Radiation Monitor General Atomic RE-90-130 R,T,QT,P,H,A,M,QM,QI Radiation Monitor General Atomic RE-90-131 R,T,QT,P,H,A,M,QM,QI Radiation Monitor General Atomic RE-90-106D R,T,QT,P,H,A,M,QM,QI Radiation Monitor General Atomic RE-90-112D R,T,QT,P,H,A,M,QM,QI
@ Radiation Monitor General Atomic RE-90-102 R,T,QT,P,H,A,M,QM,QI
@ Radiation Monitor General Atomic RE-90-103 R,T,QT,P,H,A,M,QM,QI
@ Radiation Monitor General Atomic RE-90-106 R,T,QT,P,H,A,M,QM,QI
@ Radiation Monitor General Atomic RE-90-112 R,T,QT,P,H,A,M,QM,QI
@ Radiation Monitor General Atomic RE-90-140 R,T,QT,P,H,A,M,QM,QI Radiation Monitor General Atomic RE-90-141 R,T,QT,P,H,A,M,QM,QI H M nitor Comsip R,T,QT,P,H,A,M,QM,QI 2
Auxiliary Dryers Paul Trinity R,T,QT,P,H,A,M,QM,QI A&B Panel Control Panel Terry Turbine R,T,QT,P,H,A,M,QM,QI L-326 Auxiliary Control Ingersoll-Rand R,T,QT,P,H,A,M,QM,QI Air Compressor Panel (Instru-ment Rack)
B-20
-a,--
m-,
-9
-mw
-es g,-,-
+ - -
+-ma y
4
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Air Return Fan Reliance R,T,QT,P,H,A,M,QM,QI, Motor CS Emergency Gas Lincoln R,T,QT,P,H,A,M,QM,QI Treatment AHU Mator Spent Fuel Pit Lincoln R,T,QT,P,H,A,M,QM,QI Pump AHU Motor RHR Pump Cooler Lincoln R,T,QT,P,H,A,M,QM,QI Motor SIS Pump Cooler Lincoln R,T,QT,P,H,A,M,QM,QI AHU Motor Cent. Charging Lincoln R,T,QT,P,H,A,M,QM,QI Pump Cooler AHU Motor AFW & Boric acid Lincoln R,T,QT,P,H,A,M,QM,QI Pump AHU Motor CCS Pump & AFW Lincoln R,T,QT,P,H,A,M,QM,QI Pump AHU Motor Pipe Chase AHU Lincoln R,T,QT,P,H,A,M,QM,QI Motor Containment Spray Westinghouse R,T,QT,P,H,A,M,QM,QI Pump AHU Motor Penetration Room Lincoln R,T,QT,P,H,A,M,QM,QI Coolers Motor Aux. Bldg. Gas Reliance R,T,QT,P,H,A,M,QM,QI l
Treatment Fan Motor Emergency Gas Reliance R,T,QT,P,H,A,M,QM,QI Treatment Fan Motor l
480-Volt Board Westinghouse R,T,QT,P,H,A,M,QM,QI Room AHU Motor Component Cooling Allis-Chalmers RPN Water Pump Motor B-21
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Containment Spray Lincoln R,T,QT,P,H,A,M,QM,QI Pump Motor AVC Circulation Lincoln RPN Pump AVC Circulation Lincoln RPN Pump Auxiliary Control General Electric R,T,QT,P,H,A,M,QM,QI Air Compressor Motor Pressurizer HTR Powell R,T,QT,P,H,A,M,QM,QI Dist. PNLS 10, lA-A, IB-B, 1C, 2D, 2A-A, 28-B, 2C RTD Rosemount TE-68-2A T,QT,A,M,QM RTD Rosemount TE-68-2B T,QT,A,M,QM RTD Rosemount TE-68-14 T,QT,A,M,QM RTD Rosemount TE-68-25 T,QT,A M,QM RTD Rosemount TE-68-37 T,QT,P,H,A,M,QM RTD Rosemount TE-68-44 T,QT,A,M,QM RTD Rosemount TE-68-56 T,QT,P,H,A,M,QM RTD Rosemount TE-68-67 T,QT,P,H,A,M,QM RTD Rosemount TE-68-79 T,QT,A,M,QM
- RTD Rosemount TE-68-1 T,QT,A,M,QM RTD Rosemount TE-68-18 T,QT,P,H,A,M,QM RTD Rosemount TE-68-24 T,QT,P,H,A,M,QM RTD Rosemount TE-68-41 T,QT,P,H,A,M,QM RTD Rosemount TE-68-43 T,QT,P,H,A,M,QM RTD Rosemount TE-68-60 T,QT,P,H,A,M,QM B-22
)
e*
O APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency RTD Rosemount TE-68-65 T,QT,P,H,A,M,QM RTD Rosemount TE-68-83 T,QT,P,H,A,M,QM Excore Neutron WIGID NC-41 QT,P,H,A,M,QM Detectors Excore Neutron WIGTD NC-42 QT,P,H,A,M,QM Detectors Excore Neutron WIGTD NC-43 QT,P,H,A,M,QM Detectors Excore Neutron WIGTD NC-44 QT,P,H,A M,QM Detectors
- Limit Swtiches NAMCO A,M,H Cable American SROAJ A,M Insulated Wire Cable Rockbestos SROAJ A,M Cable Rockbestos SROAJ-H l
Cable Anaconda-SROAJ A,M Continental Cable Anaconda-SROAJ-H A,M l
Continental Cable Anaconda-WVA A,M Continental Cable Anaconda-WVA(XLPE)
A,M I
Continental l
Cable Rockbestos WVA(XLPE)
A,M Cable ITT Suprenant WVA(XLPE)
A,M Cable Brand-Rex WVC(XLPE)
A,M Cable Rome Cable Type CPJ A,M,R Cable Plastic Wire Type CPJ A,M,R
& Cable i
B-23
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Cable Essex Inter-Type CPJ A,M,R national Cable Rome Cable Type CPPJ A,M,R Cable Plastic Wire Type CPPJ A,M,R
& Cable Cable ESSEX Inter-Type CPPJ A,M,R national Cable Cyprus Wire Type CPSJ A,M,R
& Cable Cable General Cable Type CPSJ A,M,R Cable Phelps Dodge Type CPSJ A,M,R C&W Cable Plastic Wire Type CPSJ A,M,R
& Cable Cable Anaconda Type CPSJ QT,A,M Cable Okonite Type EPSJ QT,A,M Cable American Type PXJ A,M Insulated Wire Cable General Electric Type PXJ A,M l
Cable American Type PXMJ A,M i
Insulated 'Jire Cable Essex Type PXMJ A,M Cable General Electric Type PXMJ A,M Cable Okonite Type XLPE A,M,R
- Cable Belden Type XLPE A,M
- Cable Brand-Rex Type XLPE A,M Cable Rockbestos Type XLPE A,M Cable Eaton Corp.
Type XLPE A,M Cable Samuel Moore Type XLPE A,M B-24
O APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Cable Anaconda-Type XLPE A,M Continental Cable ITT Suprenant Type XLPE A,M Cable Times Wire Type XLPE A,M and Cable Cable Boston Type XLPE A,M Insulated Wire Cable Anaconda Wire ETFE M,A and Cable Cable Caroline Wire ETFE M,A and Cable Cable Teledyne ETFE M,A Thermatics Cable Times Wire ETFE M,A
& Cable Junction Boxes NA NA H,P,QT,A,M,QM Electrical Westinghouse A,M,QM Penetration Assemblies Transducer Robertshaw R,H,QT,M,A,QM,QI Transducer Robertshaw R,H,QT,M,A,QM,QI Terminal Blocks QT,R,QM,A,M Back Up Press Westinghouse R,T,QT,P,H,A,M,QM,QI Htr (XFMR, 1A-A, IB-8, 2A-A, 28-B)
Level Transmitter Unknown LT-63-177 CS,k,T,QT,RT,P,M,H,A, QM,QI Level Transmitter Unknown LT-63-178 CS,R,T,QT,RT,P,M,H,A, QM,QI Level Transmitter Unknown LT-63-179 CS,R,T,QT,RT,P,M,H,A, QM,QI l
B-25 l
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Limitorque FCV-68-332 QT,A,M Valve Motor Operated Limitorque FCV-68-333 QT,A,M Valve Motor Operated Limitorque FCV-74-1 CS,R,T,QT,RT,P,M,H,A, Valve QM,QI Motor Operated Limitorque FCV-74-2 CS,R,T,QT,RT,P,M,H,A, Valve QM,QI Motor Operated Unknown PCV-68-334 CS,R,T,QT,RT,P,M,H,A, Valve QM,QI Motor Operated Unknown PCV-68-340A CS,R,T,QT,RT,P,M,H,A, Valve QM,QI Solenoid Valve Unknown FSV-61-194 CS,R,T,QT,RT,P,M,H,A, QM,QI Solenoid Valve Unknown FSV-61-192 CS,R,T,QT,RT,P,M,H,A, QM,QI Solenoid Valve Unknown FSV-61-122 CS,R,T,QT,RT,P,M,H,A, QM,QI Motor Operated Unknown FCV-61-97 CS,R,T,QT,RT,P,M,H,A, Valve QM,QI Motor Operated Unknown FCV-77-9 CS,R,T,QT,RT,P,M,H,A, Valve QM,QI
@ Level Switch Mercoid 0-LS-313-340 R,T,QT,RT,P,H,A,M,QM, QI
@ Level Switch Unknown 0-LS-313-305 R,T,QT,RT,P,H,A,M,QM, QI Modifier Unknown 1-LM-3-164A R,T,QT,RT,P,H,A,M,QM, QI Modifier Unknown 1-LM-3-171A R,T,QT,RT,P,H,A,M,QM, QI Solenoid Valve Unknown 1-FSV-61-191A R,T,QT,RT,P,H,A,M,QM, QI B-26
s s
g APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve Unknown 1-LSV-62-118A R T,QT,RT,P,H,A,M,QM, QI Limit Switch Unknown ZS ON1-rVC-65-86 R,T,QT,RT,P,H,A,M,QM, QI Limit Switch Unknown ZS ON1-PVC-65-87 R,T,QT,RT,P,H,A,M,QM, QI Motor Operated Linkbelt FCV-70-1 R,T,QT,RT,P,H,A,M,QM, Valve QI
@ Solenoid Valve ASCO FSV-30-114 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-115 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-116 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-117 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-118 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-119 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-120 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-121 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-124 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-125 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-128 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-131 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-132 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-296 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-297 QT,H,A,M,QM,QI
@ Solenoid Valve ASCO FSV-30-129 H,A,QT,M,QM,QI
@ Solenoid Valve ASCO FSV-30-130 H,A,QT,M,QM,QI Solenoid Valve ASCO FSV-30-106 H,A,QT,M,QM,QI Solenoid Valve ASCO FSV-30-107 H,A,QT,M,QM,QI B-27
~w
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
@ Solenoid Valve ASCO FSV-30-122 H,A,QT,M,QM,QI 0 Solenoid Valve ASCO F3V-30-123 H,A,QT,M,QH,QI Limit Switch NAMCO EA 700 QT,T,P,H,A,R,M,QM,QI Solenoid Valve ASCO FSV-30-137 RPS Solenoid Valve ASCO FSV-30-138 RPS Solenoid Valve ASCO FSV-30-140 RP3 Solenoid Valve ASCO FSV-3C-141 RPS Solenoid Valve ASCO FSV-30-160 RPS Solenoid Valve ASCO FSV-30-161 RPS Solenoid Valve ASCO FSV-30-166 RPS Solenoid Valve ASCO FSV-30-167 RPS Solenoid Valve ASCO FSV-30-271 RPS Solenoid Valve ASCO FSV-30-272 RPS Motor Goerated Limitorque FCV-26-240 QT,A,M Valve Motor Operated Limitorque FCV-26-241 QT,A,M Valve l
Motor Operated LimitorqLe FCV-26-242 QT,A,M Valve l
Motor Operated Limitorque FCV-26-243 QT,A,M Valve Solenoid Valve AVC0 FSV-30-9 QT,T,P,H,A,R,M,QM,QI Solenoid Valve AVC0 FSV-30-14 QT,T,P,H,A,R,M,QM,QI Solenoid Valve AVC0 FSV-30-16 QT,T,P,H,A,R,M,QM,QI Solenoid Valve AVC0 FSV-30-19 QT,T,P,H,A,R,M,QM,QI l
Solenoid Valve AVC0 FSV-30-37 QT,T,P,H,A,R,M,QM,QI l
Solenoid Valve AVC0 FSV-30-53 QT,T,P,H,A,R,M,QM,QI
{
l B-28
O APPENDIX B (cont'd)
Equipment Description Manufacturer Comp;nent No.
Deficiency Solenoid Valve AVC0 FSV-30-57 QT,T,P,H,A,R,M,QM,QI Solenoid Valve AVC0 FSV-30-59 QT,T,P,H,A,R,M,QM,QI Solenoid Valve ASCO FSV-30-1578 QT,A,M
@ Solenoid Valve ASCO FSV-30-13 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-18 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-28 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-29 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-32 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-33 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-34 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-35 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-36 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-41 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-49 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-55 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-76 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-79 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-91 QT,H,A M,QM,QI Solenoid Valve ASCO FSV-30-96 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-98 QT,H,A M,QM,QI l
Solenoid Valve ASCO FSV-30-112 QT,H,A,M,QM,QI Solenoid Valve ASCO FSV-30-113 QT,H,A,M,QM,QI Pressure Controller Johnson Controls FC-30-148 QT,H,A,R,M,QM,QI Pressure Controller Johnson Controls FC-30-149 QT,H,A,R,M,QM,QI B-29
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Limit Switch NAMCO EA-180 CS A Limit Switch Micro Switch P/N LSC4C T,QT,P,H,A,R,M,QM,RPN Limit Switch NAMCO SL 3C-82 T,QT,P,H,A,R,M,QM,RPN Limit Switch NAMCO EA-170 A,QT,QM Solenoid Valve Chicago Fluid FSV 1-4 (A,B,D, A,QT,M Power E,F,G,H,J)
Solenoid Valve Chicago Fluid FSV 1-29 (A,B,0, A,QT,M Power E,F,G,H,J)
Solenoid Valve Chicago Fluid FSV 1-11 (A,B,0, A,QT,M Power E,F,G,H,J)
Solenoid Valve ASCO PSV 1-6A QT,T,H,A,R,M,QM,QT Solenoid Valve ASCO PSV 1-6B QT,T,H,A,R,M,QM,QT Solenoid Valve ASCO PSV 1-31A QT,T,H,A,R,M,QM,QT Solenoid Valve ASCO PSV 1-31B QT,T,H,A,R,M,QM,QT Solenoid Valve ASCO PSV 1-13A QT,T,H,A,R,M,QM,QT Solenoid Valve ASCO PSV 1-13B QT,T,H,A,R,M,QM,QT Solenoid Valve ASCO PSV 1-24A QT,T,H,A,R,M,QM,QT Solenoid Valve ASCO PSV 1-248 QT,T,H,A,R,M,QM,QT Motor Operated Limitorque FCV-3-136A QT,M,A Valve l
Motor Operated Limitorque FCV-3-1368 QT,M,A Valve Motor Operated Limitorque FCV-3-179A QT,M,A Valve Motor Operated Limitorque FCV-3-1798 QT,M,A Valve Solenoid Valve ASCO LSV-3-148A QT,T,H,A,M,QM,QI Solenoid Valve ASCO LSV-3-156A QT,T,H,A,M,QM,QI B-30
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve ASCO LSV-3-164A QT,T,H,A,M,QM,QI Solenoid Valve ASCO LSV-3-171A QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-77-128 QT,T,H,A,M,QM,QI Solenoid Valve ASCO LSV-3-148 QT,T,H,A,M,QM,QI Solenoid Valve ASCO LSV-3-156 QT,T,H,A,M,QM,QI Solenoid Valve ASCO LSV-3-164 QT,T,H,A,M,QM,QI Solenoid Valve ASCO LSV-3-171 QT,T,H,A,M,QM,QI
@ Solenoid Valve ASCO LSV-3-172 QT,T,H,A,M,QM,QI Solenoid Valve ASCO LSV-3-173 QT,T,H,A,M,QM,QI 0 Solenoid Valve ASCO FSV-77-241 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-1-7 QT,T,H,A,M,QH,QI Solenoid Valve ASCO FSV-1-14 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-1-25 QT,T,H,A,N,QM,QI Solenoid Valve ASCO FSV-1-32 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-1-147 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-1-150 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-1-148 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-1-149 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-90-107 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-90-111 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-90-113 QT,T,H,A,M,QM,QI Solenoid Valve ASCO FSV-90-117 QT,T,H,A,M,QM,QI Transducer Masoneilan LM-3-156A QT,H,A,R,M,QM,QI
@ Solenoid Valve ASCO FSV-12-79 QT,QM,H,A Solenoid Valve VALCOR FSV-30-46A CS,A,QT,M B-31
APPENDIX B (cont'd)
(quipment Description Manufacturer Component No.
Deficiency Solenoid Valve VALCOR FSV-30-48A CS,A,QT,M Electro-Hydraulic MEA PM-3-122 QT,T,H,A,R,M,QM,QI Valve Operator j
Electro-Hydraulic MEA PM-3-132 QT,T,H,A,R,M,QM,QI Valve Operator Transmitter Railey PT-3-132A QT,H,A,R,M,QM,QI Pressure Switch Barton PS-30-46A QT,M,QM,QI,A 4 Pressure Switch Barton PS-30-46B QT,M,QM,QI,A,H Pressure Switch Barton PS-30-47A QT,M,QM,QI,A,H Pressure Switch Barton PS-30-478 QT,M,QM,QI,A,H Pressure Switch Barton PS-30-48A QT,M,QM,QI,A,H Pressure Switch Barton PS-30-488 QT,M,QM,QI,A,H Solenoid Valve ASCO FSV-67-342 QT,M,QM,QI,A,H Solenoid Valve ASCO FSV-70-85 QT,M,QM,QI,A,H Pressure Barton PDIS-1-17 QT,QM,QI,H,A,R,M Differential Indicating Switch Pressure Barton PDIS-1-18 QT,QM,QI,H,A,R,M l
Dift.rential l
Indicating Switch Pressure Switch Custom Component PS-3-138A QT,T,H,A,R,M,QM,QI l
Pressure Switch Custom Component PS-3-1388 QT,T,H,A,R,M,QM,QI j
Pressure Switch Custom Component PS-3-148 QT,T,H,A,R,M,QM,QI Pressure Switch Custom Component PS-3-156 QT,T,H,A,R,M,QM,QI Pressure Switch Custom Component PS-3-164 QT,T,H,A,R,M,QM,QI Pressure Switch Custom Component PS-3-171 QT,T,H,A,R,M,QM,QI Transmitter Bailey FT-3-142 QT,T,H,A,R,M,QM,QI
@ Radiation Monitor General Atomic RE-90-133 H,M,QT,QM,QI,A,R B-32
o APPENDIX B (cont'd)
Equipment Description Manufacturer Compcnent No.
Deficiency
@ Radiation Monitor General Atomic RE-90-134 H,M,QT,QM,QI,A,R Differential Barton FIS-70-81 H,R,QT,A,QM,QI,M Pressure Switch Pressure Switch Custom Component PS-3-140A H,QT,R,A,M,QM,QI Pressure Switch Custom Component PS-3-150A H,QT,R,A,M,0M,QI Pressure Switch Custom Component PS-3-139A H,QT,R,A,M,QM,QI Pressure Switch Custom Component PS-3-1398 H,QT,R,A,M,QM,QI Pressure Switch Custom Component PS-3-13CD H,QT,R,5,M,QM,QI Pressure Switch Custom Component PS-3-144A H,QT,R,A,M,QM,QI Pressure Switch Custom Component PS-3-144B H,QT,R,A,M,QM,QI Pressure Switch Custom Component PS-3-144D H,QT,R,A,M,QM,QI Pressure Switch Custom Component PS-3-140B H,QT,R,A,M,QM,QI Pressure Switch Custom Component PS-3-1508 H,QT,R,A,M,QM,QI
@ Temperature Switch Fenwal TS12-91A QT,H,A,R,M,QM,QI
@ Temperature Switch Feawal TS12-918 QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-92A QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-928 QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-93A QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-938 QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-94A QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-94B QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-95A QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-95B QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-96A QT,H,A,R,M,Qfi,QI
@ Temperature Switch Fenwal TS12-968 QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-97A QT,H,A,R,M,QM,QI B-33
)
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
@ Temperature Switch Fenwal TS12-978 QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-98A QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-988 QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-99A QT,H,A,R,M,QM,QI
@ Temperature Switch Fenwal TS12-998 QT,H,A,R,M,QM,QI Motor Operated Limitorque FCV-67-130 QT,A,M Valve Motor Operated Limitorque FCV-67-131 QT,A.M Valve Motor Operated Limitorque FCV-67-133 QT,A,M Valve Motor Operated Limitorqua FCV-67-134 QT,A,M Valve Motor Operated Limitorque FC'V-67-138 QT,A,M Valve i
Motor Operated Limitorque FLV-67-139 QT,A,M Valve Motor Operated Limitorque FC'!-67-141 QT,A,M Valve l
Motor Operated Limitorque FCV-67-142 QT,A,M Valve
@ Motor Operated Linkbelt FCV-70-206 QT,T,P,A,M,QM,QI Valve i
@ Motor Operated Linkbelt FCV-70-207 QT,T,P,A,M,QM,QI Valve
@ Motor Operated Linkbelt FCV-70-208 QT,T,P,A,M,QM,QI Valve l
Motor Operated Limitorque FCV-72-22 QT,A,R,M,QM,QI Valve Solenoid Valve ASCO FSV-313-222 RPS Solenoid Valve ASCO FSV-313-229 RPS B-34 1
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve ASCO FSV-313-231 RPS Limit Switch Micro Switch OP-AR QT,T,P,H,A,R,M,QM,QI Solenoid Valve ASCO FSV-87-8 QT,T,P,H,A,R,M,QM,CS Solenoid Valve ASCO FSV-68-307 QT,T,P,H,A,R,M,QM Transmitter Foxboro PDT-30-44 QT,T,P,H,A R.M,QM Transmitter Foxboro PDT-30-45 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO PSV-68-334 QT,T,P,H,A,R,M,0M Solenoid Valve ASCO PSV-68-340AA QT,T,P,H,A,R,M,QM Solenoid Valve ASCO PSV-68-340AB QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-30-86 QT,T,P,H,A,R,M,QM Motor Operated Limitorque FCV-74-33 QT,T,P,H,A,R,M,QM Valve Motor Operated Limitorque FCV-74-35 QT,T,P,H,A,R,M,QM Valve Solenoid Valve ASCO FSV-61-193A QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-61-96 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-61-110 QT,T,P,H,A.R,M,QM Transmitter Foxboro
?T-1-12 QT,7,P,H,A,R,M,QM Transmitter Foxboro PT-1-23 QT,T,P,H,A,R,M,QM Switch Foxboro FIS-74-12 QT,T,P,H,A,R,M,QM Switch Foxboro FIS-74-24 QT,T,P.H,A,R,M,QM Soleno',d Valve ASCO LSV-3-175 QT,T,P,H,A,R,M,QM Motor Operated Limitorque LCV-3-148 QT,T,P,H,A,R,M,QM Val /e l
- tTransmitter Foxboro FT-3-35A QT,T,P,H,A,R,M,QM
- tTra,smitter Foxboro
~T-3 358 QT,T,P,H,A,R,M,QM r
l l
B-35
-.-----...w,--..
,r-
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
- tiransmitter Foxboro FT-3-48A QT,T,P,H,A,R,M,QM
- tTransmitter Foxboro FT-3-488 QT,T,P,H,A,R,M,QM
- tTransmitter Foxboro FT-3-90A QT,T,P,H,A,R,M,QM
- tTransmitter Foxboro FT-3-908 QT,T,P,H,A,R,M,QM
- tTransmitter Foxboro FT-3-103A QT,T,P,H,A,R,M,QM
- tTransmitter Foxboro FT-3-103B QT,T,P,H,A,R,M,QM
@ Motor Operated Limitorque LCV-62-132 QT,T,P,H,A,R,M,QM Valve
@ Motor Operated Limitorque LCV-62-133 QT,T,P,H,A,R,M,QM Valve
@ Motor Operated Limitorque FCV-87-22 QT,T,P,H,A,R,M,QM Valve
@ Motor Operated Limitorque FCV-87-23 QT,T,P,H,A,R,M,QM Valve
@ Motor Operated Limitorque FCV-87-24 QT,T,P,H,A,R,M,QM Valve Solenoid Valve ASCO FSV-87-9 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-87-10 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-63-23 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-63-64 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-68-305 QT,T,P,H,A,R,M,QM Transmitter Bailey FT-70-81E QT,T,P,H,A,R,M,QM Motor Operated Limitorque FCV-62-63 QT,T,P,H,A,R,M,QM,QI Valve tTransmitter Foxboro PT-1-2A QT,T,P,H,A,R,M,QM tTransmitter Foxboro PT-1-27A QT,T,P,H,A,R,M,QM tTransmitter Foxboro PT-1-5 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO FSV-30-87 QT,T,P,H,A,R,M,QM Solenoid Valve ASCO LSV-3-174 QT,T,P,H,A,R,M,QM B-36
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Vt.1ve Chicago Fluid FSV-1-22(A,B, QT,T,P,H,A,R,M,QM Power D,E,F,G,H,J)
Switch Barton FIS-74-12 QT,T,P,H,A,R,M,QM Switch Barton FIS-74-24 QT,T,P,H,A,R,M,QM Motor Operated Limitorque FCV-75-206 QT,T,P,H,A,R,M,QM,QI Valve tTransmitter Foxboro FT-3-35A QT,T,P,H,A,R,M,QM,QI tTransmitter Foxboro FT-3-35B QT,T,P,H,A,R,M,QM,QI tTransmitter Foxboro FT-3-48A QT,T,P,H,A,R,M,QM,QI tTransmitter Foxboro FT-3-90A QT,T,P,H,A,R,M,QM,QI tTransmitter Foxboro FT-3-908 QT,T,P,H,A,R,M,QM,QI 1
tTransmitter Foxboro FT-3-103A QT,T,P,H,A,R,M,QM,QI tTransmitter Foxboro FT-3-103B QT,T,P,H,A,R,M,QM,QI Motor Operator Limitorque LCV-62-135 QT,T,P,H,A,R,M,QM l
Valve l
Motor Operator Limftorque LCV-62-136 QT,T,P,H,A,R,M,QM l
Valve l
Motor Operator Limitorque FCV-26-244 QT,T,P,H,A,R,M,QM Valve Motor Operator Limitorque FCV-26-245 QT,T,P,H,A,R,M,QM l
Valve Solenoid Valve ASCO FSV-1-181 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-1-182 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-1-183 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-1-184 QT,T,P,H,A,R,M,CS,QM,QI l
Solenoid Valve ASCO FSV-77-127 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-90-108 QT,T,P,H,A,R,M,CS,QM,.QI Solenoid Valve ASCO FSV-90-109 QT,T,P,H,A,R,M,CS,QM,QI l
B-37 w-
-y y
+,,. _,.,
i.--,,w--
-.r
-y.
w-
.I,
O APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve ASCO FSV-90-110 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-90-114 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-90-115 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-90-116 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-30-298 QT,T,P,H,A,R,M,CS,QM,QI Solenoid Valve ASCO FSV-30-299 QT,T,P,H,A,R,M,CS,QM,QI
@ Solenoid Valve ASCO FSV-30-3 QT,T,P,H,A,R,M,CS,QM,QI
@ Solenoid Valve ASCO FSV-30-6 QT,T,P,H,A,R,M,CS,QM,QI
@ Solenoid Valve ASCO FSV-30-60 QT,T,P,H,A,R,M,CS,QM,QI
@ Solenoid Vaive ASCO FSV-30-69 QT,T,P,H,A,R,M,CS,QM,QI
@Solenaid Valve ASCO FSV-30-146A QT,T,P,H,A,R,M,CS,QM,QI
@ Solenoid Valve ASCO FSV-30-146B QT,T,P,H,A,R,M,CS,QM,QI
$ Temperature Switch Penn TS-30-187 QT,P,H,A,R,M,T,QM,QI
$ Temperature Switch Penn TS-30-200 QT,P,H,A,R,M,T,QM,QI
$ Temperature Switch Penn TS-30-207 QT,P,H,A,R,M,T,QM,QI l
$ Temperature Switch Penn TS-30-186 QT,P,H, A,R,M,T,QM,QI
$ Temperature Switch Fenwal TS-30-104 QT,T,P,H,A,R,M,QM,QI
$ Solenoid Valve ASCO FSV-67-217 QT,T,P,H,A,R,M,QM,QI
$ Solenoid Valve ASCO FSV-67-219 QT,T,P,H,A,R,M,QM,QI
$ Solenoid Valve ASCO FSV-67-336 QT,T,P,H,A,R,M,QM,QI l
$ Solenoid Valve ASCO FSV-67-338 QT,T,P,H,A,R,M,QM,QI
$ Flow Switch Dwyer FS-30-157 QT,T,P,H,A,R,M,QM,QI
$ Flow Switch Dwyer FS-30-200 QT,T,P,H,A,R,M,QM,QI
$ Flow Switch Dwyer FS-30-207 QT,T,P,H,A,R,M,QM,QI
$ Temperature Switch Honeywell TS-30-104A QT,T,P,H,A,R,M,QM l
1 B-38 i
I
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
$ Cable Brand-Rex WVA(XLPE)
A,M
$ Cable Samuel Moore WVA(XLPE)
A,M
$ Cable Continental WVC(FREP)
A,M Wire & Cable
$Handswitch Cutler Hammer 2-HS-153 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-200 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-207 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-1-158 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-1-16B QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-1-17B QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-1-188 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-3-338 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-3-1008 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-3-47B QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-3-878 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-70-148 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-70-168 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-70-188 QT,T,P,H,A,R,M,QM,QI SHandswitch Cutler Hammer 2-HS-70-28B QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Ham.mcr 2-HS-70-29B QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-70-76B QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-70-78B QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-70-158 QT,T,P,H,A,R,M,QM,QI l
$Handswitch Cutler Hammer 2-HS-70-1968 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-30-1578 QT,T,P,H,A,R,M,QM,QI i
B-39
APPENDIX B (cont'd)
~~
Equipment Description Manufacturer Component No.
Deficiency
$Handswitch Cutler Hammer 2-HS-32-81A QT,T,P,H,A,R,M,QM,QI
$ Hand 3 witch Cutler Hammer 2-HS-32-103A QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-32-1038 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-32-111A QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-32-1118 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-30-196 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-30-1388 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-30-187 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-72-408 QT,T,P,H,A,R,M,QM,QI
$Handswitch Cutler Hammer 2-HS-72-418 QT,T,P,H,A,R,M,QH,QI Solenoid Valve ASCO FSV-30-102 QT,P,H,A,R,M,T,QM,QI Solenoid Valve ASCO FSV-30-109 QT,P,H,A,T,R,M,QM,RPS Motor Operated Limitorque FCV-63-172 QT,A,M Valve
$ Transmitter Barton LT-3-38 A,M
$ Transmitter Barton LT-3-39 A,M
$ Transmitter Barton LT-3-42 A,M
$ Transmitter Barton LT-3-51 A,M
$ Transmitter Barton LT-3-52 A,M
$ Transmitter Barton LT-3-55 A,M
$ Motor Operated Limitorque FCV-63-157 QT,T,P,H,A,R,M,QM,QI Valve
$ Motor Operated Limitorque FCV-74-3 QT,T,P,H,A,R,M,QM,QI Valve
$ Solenoid Valve ASCO FSV-62-143 QT,T,P,H,A,M,QM
$ Solenoid Vaive ASCO FSk 62-128 QT,T,P,H,A,R,M,QM,QI B-40
~,. _ -.
APPENDIX B (cont'd) 1 Equipment Description Manufacturer Component No.
Deficiency
$ Solenoid Valve ASCO FSV-77-20 QT,T,P,H,A,R,M,QM,QI 8
$ Solenoid Valve ASCO FSV-62-144 QT,T,P,H,A,R,M,QM,QI
$ Solenoid Valve Limitorque FCV-63-175 QT,T,P,H,A,R,M,QM,QI
$ Transmitter Barton LT-63-176 QT,A,M
$ Transmitter Barton LT-63-177 QT,A,M
$ Transmitter Barton LT-63-178 QT,A,M
$ Transmitter Barton LT-63-179 QT,A,M
$ Transmitter Barton PT-68-69 QT,A,M
$ Solenoid Valve ASCO FSV-87-11 QT,A,M,QM
$tTransmitter Foxboro FT-1-3A QT,T,P,H,A,R,M,QM
$tTransmitter Foxboro FT-1-3B QT,T,P,H,A,R,M,QM
$tTransmitter Foxboro FT-1-21A QT,T,P,H,A,R,H,aM StTransmitter Foxboro FT-1-218 QT,T,P,H,A,R,M,QM
$tTransmitter Foxboro FT-1-28A QT,T,P,H,A,R,M,QM
$tTransmitter Foxboro FT-1-28B QT,T,P,H,A,R,M,QM
$tTransmitter Foxboro FT-3-38 QT,T,P,H,A,R,M,QM,QI
$tTransmitter Foxboro FT-3-51 QT,T,P,H,A,R,M,QM,QI
$tTransmitter Foxboro FT-3-107 QT,T,P,H,A,R,M,QM,QI
$tTransmitter Foxboro FT-3-55 QT,T,P,H,A,R,M,QM,QI
$ Solenoid Valve ASCO FSV-63-38 QT,T,P,A,M,QM
$ Solenoid Valve ASCO FSV-77-20 QT,T,P,A,M,QM
@ Solenoid Valve ASCO FSV-65-52 QT,A,M
@ Solenoid Valve ASCO FSV-65-53 QT,A,M
@ Solenoid Valve ASCO FSV-65-30 QT,A,M
@ Solenoid Valve ASCO FSV-65-26 QT,A,M B-41
s.
s e
~
e O
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
@ Solenoid Valve ASCO FSV-6S-27 QT,A,M Solenoid Valve ASCO FSV-65-4 RPS Solenoid Valve ASCO FSV-65-5 RPS
@ Solenoid Valve ASCO FSV-65-24 RPS
@ Solenoid Valve ASCO FSV-65-43 RPS
@ Solenoid Valve ASCO FSV-65-9 RPS
@ Solenoid Valve ASCO FSV-65-29 RPS
@Solencid Valve ASCO FSV-65-45 RPS
@ Solenoid Valve ASCO FSV-65-46 RPS Handswitch Cutler-Hammer HS-62-61B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-67B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-800 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-9BB QT,T,P,H A,R,M,QM,QI i
Handswitch Cutler-Hammer HS-63-1188 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-172B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-3328 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-3338 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-32-80A QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hammer HS-32-808 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-32-110A QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-32-1108 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-67-838 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-67-888 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-67-918 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-67-968 QT,T,P,H,A,R,M,QM,QI B-42
APPENDIX B (cont'd) i Equipment Description Manufacturer Component No.
Deficiency 1
Handswitch Cutler-Hamer HS-67-998 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-104B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1078 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1128 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-130B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1318 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1338 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1348 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1388 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer HS-67-139B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1418 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-67-1428 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer HS-43-2 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-43-11 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-43-22 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-43-34 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-43-75 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-32 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-33 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-34 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-35 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-121 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-124 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-125 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-128 QT,T,P,H,A,R,M,QM,QI l
B-43 l
l
o APPENDIX C (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hammer 1-HS-30-131 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-132 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-296 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-297 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-298 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-299 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-65-238 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-65-42B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-60 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-69 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-177 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-178 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-179 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-180 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-182 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-183 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-62-104B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-62-108B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-63-48 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-63-10B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-63-158 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-63-478 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-175B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-72-10B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-72-27B QT,T,P,H,A,R,rt,QM,QI B-44
s APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hamer HS-3-136A/B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-3-136B/B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-30-214 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-46-548 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-46-54D QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-46-55B QT,T,P,H,A.R.M,QM,QI Handswitch Cutler-Hamer HS-46-56B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-3-1798 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-3-179A QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-30-175 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-30-176 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-74-38 Q1 ; T,P,H, A,R,M,QM,QI Handswitch Cutier-Hamer HS-74-108 QT,i,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-74-208 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-74-218 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer 0-HS-70-1118 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-78-20 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-75B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-168A QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-1-118 QT,T,P,H,A,R,M,QM,QI Handswitch C'Jtler-Hamer HS-1-228 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-1-220 QT,T,P,H,A,R,M,QM,QI Handswiten Cutler-Hamer HS-74-33B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-74-358 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamcr 1-HS-43-2 QT,T,P,H,A,R,M,QM,QI t
l l
B-45
{
v APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hamer 1-HS-43-2A QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-43-11 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-43-12 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-43-22 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-43-23 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-43-34 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-43-35 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-43-75 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-43-77 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-H5-70-153B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-1838 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-30-190 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-30-191 QT,T,P,H,A,R,M,QM,QI i
Handswitch Cutler-Hamer 0-HS-70-338 QT,T,P,H,A,R,M,QM,QI Handswitch C(.tl er-Hamer 0-HS-70-33B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-34B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-38B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-398 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer 0-HS-70-46B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-70-598 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-3-116A/B QT,T,P,H,A,R M,QM,QI Handswitch Cutler-Hammer 1-HS-3-1168/B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-3-1188 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-3-126A/B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-3-126B/B QT,T,P,H,A,R,M,QM,QI B-46 w
APPENDIX B (cont'd)
Eipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hamer 1-HS-3-1288 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-138 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-22B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-238 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-25B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-268 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-278 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-57B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-64B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-74B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-1568 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-13 QT,T,P,H,A.R.M,QM,QI Handswitch Cutler-Hamer 1-HS-30-18 QT,T,P,H,A,R,M,QM,QI Handswi ch Cutler-Hamer 1-HS-30-76 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-79 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-91 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer 1-HS-30-96 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-115 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer 1-HS-30-116 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-117 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer 1-HS-30-118 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-119 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-120 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-30-192 QT,T,P,H,A,R,M,QM,QI l
Handswitch Cutler-Hamer 0-HS-30-193 QT,T,P,H,A,R,M,QM,QI l
B-47
O APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hamer 0-HS-31C-3038 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-31C-3388 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-67-1518 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-67-1528 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-67-4788 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-1B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-118 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-128 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-408 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-41B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-193B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-1948 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-1978 QT,T,P,H,A.R M,QM,QI Handswitch Cutler-Hamer 0-HS-70-1988 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 0-HS-70-208 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-67-1238 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-67-1278 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-67-1288 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-67-1468 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-67-147C QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-67-2338 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-67-4248 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-28 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-3B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-70-4B QT,T,P,H,A,R,M,QM,QI B-48
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hammer 1-HS-70-8B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-70-9B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-70-108 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-70-130B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-70-131B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-70-2078 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-31C-323 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-31C-332 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-31C-358 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-31C-367B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-31C-3838 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-310-384B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-31C-391B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 0-HS-31C-3928 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-36 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-41 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-49 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-55 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hae mer 1-HS-30-98 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-112 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-113 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-114 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-29 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer 1-HS-30-146B QT,T,P,H,A,R,M,QM,QI B-49
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hamer 1-HS-32-80A QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-32-808 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-32-102A QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-32-1028 QT,T,P,H,A,R.M,QM,QI Hand: witch Cutler-Hamer 1-HS-32-1108 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-65-80 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-65-82 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-65-90 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-65-97 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-1338 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-133C QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-70-1348 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-72-2B QT,T,P,H,A,R,M,QM,QI Handswitch Cutier-Hamer 1-HS-30-28 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-194 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer 1-HS-30-195 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-26-240 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-62-638 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-62-908 QT,T.P,H,A,R,M,QM.QI Handswitch Cutler-Hammer HS-62-918 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-62-98 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-62-99 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-63-1B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-63-38 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-63-5B QT,T,P,H,A,R,M,QM,QI B-50
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hammer HS-63-6B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-7B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-8B QT,T.P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-11B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-228 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-258 QT,T,P,H,A,R,M,QH,QI Handswitch Cutler-Hammer HS-63-26B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-36 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-37 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-39B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-408 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-938 QT,T,P,H,A,R,M,QM.QI Handswitch Cutler-Hammer HS-63-948 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-1528 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-1538 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-156B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-63-1578 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-70-908 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-70-92B QT,T,P,H,A,R M,QM,QI Handswitch Cutler-Hammer HS-70-1398 QT,T,P,H,A,R,M,QM,QI
... dswitch Cutler-Hammer HS-70-140B QT,T,P,H,A,R M,QM,QI Handswitch Cutl e r-Hammer HS-70-143B OT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-72-138 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-72-21B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-72-34B QT,T,P,H,A,R,M,QM,QI B-51
O APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Handswitch Cutler-Hamer HS-72-24B QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-74-248 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-74-128 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-72-208 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-72+228 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-26-242 QT,T,P,H,A,R,M,QH,QI Handswitch Cutler-Hammer HS-26-245 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Himer HS-43-2 QT,T,P,H,A,R,M,QM,QI Handswitch Cutle-Hammer HS-43-11 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hamer HS-43-22 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-43-34 QT,T,P,H,A,R,M,QM,QI Handswitch Cutler-Hammer HS-43-75 QT,T,P,H,A,R,M,QM,QI Solenoid Valve ASCO FSV-30-275 RPS Solenoid Valve ASCO FSV-30-276 RPS Limit SwitcP NAMCO EA-170 QT,A,M Solenoid Valve AVC0 FSV-65-7 QT,T,P,H,A,R,M,QM,QT
@ Solenoid Valve AVC0 FSV-65-8 QT,T,P,H,A,R,M,QM,QT 0 Solenoid Valve AVC0 FSV-65-28A QT,T,P,H,A,R,M,QM,QT
@ Solenoid Valve AVC0 FSV-65-288 QT,T,P,H,A,R,M,QM,QT
@ Solenoid Valve AVC0 FSV-65-47A QT,T,P,H,A,R,M,QM,QT
@ Solenoid Valve AVC0 FSV-65-478 QT,T,P,H,A,R,M,QM,QT 1
1
@ Solenoid Valve AVC0 FSV-65-50 QT,T,P,H,A,R,M,QM,QT l'
@ Solenoid Valve AVC0 FSV-65-51 QT,T,P,H,A,R,M,QM,QT
@ Solenoid Valve ASCO FSV-65-10 RPS i
l Limit Switch NAMCO EA-700 QT,T,P,H,A,R,M,QM,QI l
B-52 i
APPENDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency Motor Operated Limitorque FCV-67-83 QT A.M Valve Motor Operated Limitorque FCV-67-88 QT A.M Valve Motor Operated Limitorque FCV-67-91 QT,A.M Valve Motor Operated Limitorque FCV-67-96 QT,A,M Valve Motor Operated Limitorque FCV-67-99 QT,A,M Valve Motor Operated Limitorque FCV-67-104 QT,A,M Valve Motor Operated Limitorque FCV-67-107 QT,A,M Valve Motor Operated Limitorque FCV-67-112 QT,A.M Valve (fMotor Operated Limitorque FCV-67-424 M,A
'/alve
@ Solenoid Valve Asco FSV-65-52 A,QT,A,M
' @ Solenoid Valve Asco FSV-65-53 A,QT,A M
@ Solenoid Valve Asco FSV-65-30 A,QT,A,M
@ Solenoid Valve Asco FSV-65-26 A,QT.A.M
@ Solenoid Valve Asco FSV-65-27 A,QT,A M Solenoid Valve Asco FSV-65-4 RPS Solenoid Valve Asco FSV-65-5 RPS i
@ Solenoid Valve Asco FSV-65-24 RPS
@ Solenoid Valve Asco FSV-65-43 RPS l
@ Solenoid Valve Asco FSV-65-9 RPS
@ Solenoid Valve Asco FSV-65-29 RPS B-53
APPEPDIX B (cont'd)
Equipment Description Manufacturer Component No.
Deficiency
@ Solenoid Valve Asco FSV-65-45 RPS
@ Solenoid Valve Asco FSV-65-46 RPS
@ Motor Operated Limitorque FCV-87-22 QT,T,P,H,A,R,M, Valve QM,qI j
l B-54
,-,-,-e-
,,.--.n.,..
e.-
,-.,n,
APPENDIX C Equipment Considered Acceptable or Conditionally Acceptable (Category 4.3)
LEGEND:
Designation for Deficiency R - Radiation T - Temperature QT - Qualification Time RT - Required Time P - Pressure H - Humidity CS - Chemical spray A - Material aging evaluation, replacement schedule, ongoing equipment surveillance S - Submergence M - Margin I - HELB evaluation outside containment not completed QM - Qualification method RPN - Equipment relocation or replacement, adequate scheduis not provided EXN - Exempted equipment justification inadequate SEN - Separate effects qualification justification inadequate QI - Qualification information being developed RPS - Equipment relocation or replacement schedule provided Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve Asco FSV-43-201 A
Solenoid Valve Asco FSV-43-202 A
Solenoid Valve Asco FSV-43-207 A
Solenoid Valve Asco FSV-43-208 A
Solenoid Valve Asco FSV-43-2 A
l Solenoid Valve Asco FSV-43-22 A
- Solenoid Valve Asco FSV-43-34 A
Solenoid Valve Asco FSV-43-75 A
Solenoid Valve Asco FSV-43-77 A
@ Items unique to Unit 1 or shared by Units 1 and 2.
$ Items unique to Unit 2.
l C-1 l
~_
APPENDIX C (Continued)
Equipment De1cription Manufacturer Component No.
Deficiency Solenoid Valve Asco FSV-43-3 A
Solenoid Valve Asco FSV-43-12 A
Solenoid Valve Asco FSV-43-33 A
Solenoid Valve Asco FSV-43-35 A
Solenoid Valve Asco FSV-43'11 A
Solenoid Valve Asco FSV-77-19 A
@ Solenoid Valve Asco FSV-77-20 A
- Solenoid Valve Target Rock FSV-30-134 A
- Heat Shrink Splices Ray : hem A
Solenoid Valve Asco PSV-65-81 A
Solenoid Valve Asco PSV-65-83 A
@ Solenoid Valve Asco FSV-32-80A A
@ Solenoid Valve Asco FSV-32-808 A
Solenoid Valve Asco FSV-32-102A A
Solenoid Valve Asco FSV-32-102B A
@ Solenoid Valve Asco FSV-32-110A A
@ Solenoid Valve Asco FSV-32-1108 A
GSolenoid Valve Asco LSV-3-175 A
Solenoid Valve Asco LSV-3-174 A
Solenoid Valve Asco FSV-77-17 A
Solenoid Valve Asco FSV-77-10 A
- NOTE:
Items for which supporting environmental qualification documentation was audited by NRR 1
C-2
, a
?"
O APPENDIX C (Continued)
Equipment Description Manufacturer Component No.
Deficiency Solenoid Valve Asco FSV-32-23 A
Solenoid Valve Asco FSV-6' -19 A
s Solenoid Valve Asco FSV-65-20 A
Asco FSV-32-81A A
$ Solenoid Valve Asco FSV-32-81B A
$ Solenoid Valve Asco FSV-32-103A A
$Solenc!d Valve Asco FSV-32-111A A
$ Solenoid Valve Asco FSV-32-111B A
Solenoid Valve Asco FSV-68-308 A
Solenoid Valve Asco FSV-87-7 A
Solenoid Valve Asco FSV-77-16 A
Solenoid Valve Asco FSV-77-18 A
Pressure Transmitter Barton PT-68-322 A
Pressure Transoitter Barton PT-68-323 A
Pressure Transmitter Barton PT-68-334 A
Pressu e Transmitter Barton PT-68-340 A
I l
l l
l l
l l
C-3 1
. - - ~. -.
APPENDIX D Safety-Related Systems Listi Function System Emergency Reactor Shutdown Reactor Protection System Chemical and Volume Control System Reactor Coolant System Containment Isolation Containment Isolation Main Steam Main Feedwater Auxiliary Feedwater Chemical and Volume Control Safety Injection Residual Heat Removal Containment Spray Component Cooling Reactor Core Cooling Safety Injection Upper Head Iriection Residual Heat Removal Containment Heat Removal Ice Condenser Containment Spray Primary Containment Cooling Residual Heat Removal 1The NRC staff recognized that there are differences in nomenclature of systems because of plant vintage and engineering design; consequently some systems performing identical or similar functions may have different names.
In those instances it was necessary to verify the system (s) function with the responsible IE regional reviewer and/or the licensee.
D-1
o APPENDIX D (Continued)
Function System Core Residual Heat Removal Residual Heat Removal Main Feedwater Auxiliary Feedwater l
Component Cooling i
Essential Raw Water Cooling Steam Dump Prevention of Significant Emergency Gas Treatment Release of Radioactive Material Hydrogen Recombiners Radiation Monitoring Neutron Monitoring Ice Condenser Supporting Systems Fuel Oil, Diesel Starting Air, Standby Diesel Generator System Diesel Generator Backed AC Power, Vital 125V DC Power, Emergency Lighting Ventilation, Air Conditioning, l
Central Air High Pressure Fire Protection C0 l
Storage,FireProtection,Purgkng Spent Fuel Pit Cooling Flood Mode Boration l
l D-2
ATTACHMENT 1 Foxboro, MA 02035 U.SA The Foxboro Company m 3c.mo 12 March 1981 Subjec :
Fotential Deficiency Affecting Foxboro Tranr=itters, Model Nu=5ers N-Ell, N-E13 or Ell, E13 with suffix Codes /MCA, /MCA/RRi?, or /MCA/RR Centle=en:
Our records indicate that you have received one or = ore of the Foxboro =odel nc=bered trans=1:ters listed above. This letter is to notify you that two deficiencies have been discovered in so=e of these trans=itters which =ay exist in the units shipped to you. The trans=itters in question operate at a signal level of 10-50mA.
S'-ilar =odel nu=Lered units operating at 4-20=A are not affec:ed.
The first issue involves the possible use of incorrect insulating sleeving en
- ansistor and :ener diode lead wires in the amplifier. The second issue involves the use of a specific vendor's capacitor which is not her:etically sealed (al: hough clai=ed to be so).
As a result, the capacitor electrolyte can leak under adverse service conditions, specifically heat and ti=e.
The failure = ode is a decrease i= resistance across the capacitor resulting in electrical leakage. The tranr=1tter operation can be affected by limiting the output to so=e hind less than full value which, in ti=e, can degrade to no output at all.
Insulating Sleeving - Radiation resistant sleeving consisting of a silicone coated glass fiber braid has been substituted by a teflon sleeving in so=e tr ans=1::ers. Tests have shown that :eflon vill beco=e brittle and deteriorate wi:h a substantial integrated radiation dose. Foxboro testing has de=onstra:ed hat :he teflon sleeving used in these devices vill withstand an integrated dose of 10 =egarads vich no noticeable deterioration. Tests to 200 =egarads produce thc bri::le conditions which can resul: in :he teflon flaking fro: the wires.
Based on these tests, operating plants not expected :o exceed an integrated dose of 10 megarads have no potential proble= and no action is required.
Where the integrated dose race could exceed 10 =egarads, then units in service should be inspected 'to deter =ine if the proper insulating =aterial has been used. This can be accomplished by opening the trans=itter in accordance with Foxboro Master Instruction MI 20-145.
The a=plifier cover =ust be re=oved exposing the a=plifier asse=bly..At one end of :he asse=bly, a transistor and a :ener diode are =cunted in the base casting which serves as a hea: sink. The 1
insula:ing =aterial in question is a sleeving slipped over :he lead.1:es fron i
these two co=ponents.
The proper =aterial is white and heavy looking. Positive foXBOBO amme-se l
~
Page 2 12 March.1981
Subject:
identification can be =ade by inspec:ing one end of the =aterial to establish that the outer =aterial covers an inner braid. Teflon, if used, will be a single layer =aterial and could be ei:her clear or whi:e.
If i= proper insulation is present, then the corrective ac: ion is :o replace the-a=plifier (Foxboro P/N N0148PW). Replace =ent a=plifiers can be purchased fres your local Foxboro Sales or Service Represen:atives.
If you prefer to have Foxboro Service Persennel inspect the equip =ent and, if necessary, replace the anplifier, :his can be arranged at standard service races.
Caoaciter - The capacitor degradation problem was discovered over ci=a thr'ough tracking failure situations.
Internal correceive action has been taken to re=ove the vendor involved fro = che qualified vendor list and to purge all stock of capaci: ors from this vendor. Degrada: ion of this capaci:or is a function of ti=e and service condi:1cns with heat being a pri=ary contribu:or.
This phenc=enon was observed in recent :ests of transsi::ers using these capaci:c:s.
The capaci:or in question is =anufac:ured by Cornell-Duebilier and can be specifically iden:1fied by a type nu=her in the form TX-65-X:CCC as well as a cnogras in a box followed by a date code, e.g. l CDE 0874 l It is assigned Foxboro par nu=her N014137.
To deter =ine if this capacitor is present requires a visual inspection of the a=plifier which can be acce=plished as described above for the insulating sleeving inspec:ien. The reco== ended corrective ac:ica should the above described capaci cr be presen: is to replace the a=plifier (Foxboro ?/N N0148?W) although is is possible to replace che capacitor with a Foxboro provided substi:ute.
"se of Foxboro Service persennel to perform the inspection and replace =ent, if necessary, can be arranged at standard service rates as described above.
Due to lack of knowledge of specific applicacion, redundancy, and :he like, Foxboro cannot deter =ine if the NRC reporting require =ents of 10CFR Part 21 are applicable.
This deter =ina: ion is :he responsibility of the user and any such reporting would be =ade by :hes after ec=pleting their evaluation of :he situa: ion.
If you have any questions regarding the above, please contac: the undersigned directly.
Very cruly yours, 3 FOI30R0 CC19ANY
(,-
.llian Calder,.
age Corporate Quality Assurance joy 120381 Enclosure MI 20-145
-a,X,BO.R.O.
IO--
t
. _ _