Revised Tech Specs 3/4 1-15 & 3/4 1-3 Re Borated Water Sources
ML20003D610
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 03/23/1981
From:
PORTLAND GENERAL ELECTRIC CO.
To:
Shared Package
ML20003D608 List:
References
NUDOCS 8103270773
Download: ML20003D610 (6)


Text

.

LCA 57, Revisien 2 Attachmtnt A Page 1 of 2 REACTIVITY CONTROL SYSTEMS BORATED WATER SOURCES - SHUTDOWN LIMITING CONDITIONS FOR OPERATION 3.1.2.7 As a minimum, one of the following borated water sources shall be OPERABLE:

a.

One boric acid storage tank with:

1.

A minimum contained volume of 12,544 gallons, 2.

Between 7,000 and 7,700 ppm of baron, and 3.

A minimum solution temperature of 65*F.

b.

The refueling water storage tank with:

1.

A minimum contained volume of 101,432 gallons, 2.

Between 2,000 and 2,500 ppm of baron, and 3.

A minimum solution temperature of 37'F.

APPLICABILITY: MODES 5 and 6.

ACTION:

With no borated water sources OPERABLE, suspend all operations involving CORE ALTERATIONS or positive reactivity changes until at least one borated water source is restored to OPERABLE status.

SURVEILLANCE REQUIREMENTS l

4.1.2.7 The above-required borated water source shall be demonstrated OPERABLE:

a.

At least once per 7 days by:

1.

Verifyino the boron concentration of the water, 2.

Verifying the water level of the tank, and 3.

Verifying the boric acid storage tank solution temperature when it is the source of borated water and the outside ambient air temperature is <37*F.

TROJ AN-UNIT 1 3/4 1-15 8'1082701%

LCA 57, Revision 2 Attachment A Page 2 of 2 REACTIVITY CONTROL SYSTEMS BASES 3/4.1.2 BORATION SYSTEMS (Continued)

With the RCS temperature below 200*F, one injection system is acceptable without single failure consideration on the basis of the stable reactivity condition of the reactor and the additional restrictions prohibiting CORE ALTERATIONS and positive reactivity change in the event the single injection system becomes inoperable.

The boron inventory in the RWST or BAT is sufficient (a) to compen-sate for an inadvertent positive reactivity addition to the Reactor Coolant System of approximately 1 percent ak/k while in MODE 5 at 200'F; and (b) to maintain a constant RCS reactivity while the temperature is decreased from 200*F to 80*F.

In MODE 6, the BAT inventory is sufficient to increase the baron concentration to compensate for an inadvertent positive reactivity addition of appoximately 1 percent ak/k while in the refueling mode.

These conditions require 8494 usable gallons of 7000-ppm borated water from the boric acid storage tanks or 23,432 usable gallons of 2000-ppm borated water from the refueling water storage tank.

The required boric acid storage tank volume of 8494 gallons has been increased to a value greater than the minimum level indicating range (4050 gallons), to 12,544 gallons.

The required RWST volume of 23,432 gal-lons must be increased to account for nonusable volume due to tank geometry, letdown and vortexing considerations (78,000 gallons), to 101,432 gallons.

3/4.1.3 MOVABLE CONTROL ASSEMBLIES The specifications of this section ensure that (1) acceptable power distribution limits are mantained, (2) the minimum SHUTD')WN MARGIN is l

maintained, and (3) limit the potential effects of a rod ejection accident.

OPERABILITY of the control rod position indicators is required to determine control rod positions and thereby ensure compliance with the control rod I

alignment and insertion limits.

The ACTION statements which permit limited variations from the basic requirements are accompanied by additional restrictions which ensure that the original criteria are met. Misalignment of a rod requires measurement of peaking factors or a restriction of THERMAL POWER; either of these restrictions provides assurance of fuel rod integrity during continued operation. The reactivity worth of a misaligned rod is limited for the remainder of the fuel cycle to prevent exceeding the assumptions used in the accident analysis for a rod ejection accident.

The maximum rod drop time restriction is consistent with the assumed rod drop time used in the accident analyses.

Measurement with T va >550*F a

and with all reactor coolant pumps operating ensures that the measGred drop times will be representative of insertion times experienced during a reactor trip at operating conditions.

TROJAN-UNIT 1 B 3/4 1-3 GAZ/4sh10A10