05000324/LER-1980-108-03, /03L-0:on 801202,drywell Equipment Drain Leakage Integrator Indicating Five Gpm W/No Pumps Running.Caused by Drywell Equipment Drain Square Root Converter Being Out of Calibr.Converter Recalibr

From kanterella
(Redirected from ML20002B990)
Jump to navigation Jump to search
/03L-0:on 801202,drywell Equipment Drain Leakage Integrator Indicating Five Gpm W/No Pumps Running.Caused by Drywell Equipment Drain Square Root Converter Being Out of Calibr.Converter Recalibr
ML20002B990
Person / Time
Site: Brunswick 
Issue date: 12/31/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20002B988 List:
References
LER-80-108-03L, LER-80-108-3L, NUDOCS 8101070493
Download: ML20002B990 (1)


LER-1980-108, /03L-0:on 801202,drywell Equipment Drain Leakage Integrator Indicating Five Gpm W/No Pumps Running.Caused by Drywell Equipment Drain Square Root Converter Being Out of Calibr.Converter Recalibr
Event date:
Report date:
3241980108R03 - NRC Website

text

-

LICtNdt:t tvciv a ncrvn e CONTR'JL BLOCK: l l

l l

l l

l (PLEASE PRINT CCI TYPE ALL EECU1 RED INF3RMATIONI i

6 Io ITl i N l C l B l E l P l 2 l@l 0 l 0 l - l 0 l 0 l 0 l 0 l 0 l-l 0 l 0 l@l 4 l 1 l 1 l 1 l

l@

25 26 LICENSE TYPE Jo 27 LAr sa 7

8 9 LICEN5EE CCOE le 15 LaCENstswumEM sour] l L @l 0 l 5 l 0 l - l 0 l 3 l 2 l 4 @l 1 l 2 l 0 l 2 l 8 l 0 l@l1 CON'T ud 69 EVENT QATE le 35 REPORT DATE 60 o i 60 64 QOCKET NUM8ER F

S EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h the drvwell i

f5 TT1 i During normal plant surveillance, the control operator noticed that l

~

l equipnent drain leakage integrator was indicating 5 gallons per minute with no pumps o 3 l

The health and safety of the public was not affected by this event.

~

l running.

o.

l O s !

I O 6 l 1

0 7 l Technical Specifications 3.4.3.1, 6.9.1.9b I

lo9jg i

as CE CE

$ SCO E COMPONENT CCQE SUS dE SU E

g l C l I j@ l E l@ l G l@ lI lN lS lT lR lU l@ l X l@ l Z l @

7 0

9 to 11 12 13 18 19 20 REVISION OCCURRENCE REPORT SEQUENTIAL EVENT VEAR REPORT No.

CODE TYPE NO.

@,aEPO,9; l9 lo l l-l l 11 ol gl [g_j l nI t l lLl l-l l 0l LER/Ro

,,, 21 22 23 24 26 27 28 29 JO Jt J2 a

KN AC 0 CN PLA T ET HOURS 58 i FOR t 8.

SLP Lt MANUFACTLRER [E jgl34Z lg lJ6Z lg l06Z(@[ 0[ 0l 0l 0l l Nl@

l N l@

l Nl@

lGl0]8)0l@

34 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @.

33 converter was found to be out of calibration. [

The drywell equipnent drain square root This is considered an

,The converter was recalibrated and returned to service.

isolated event and no further action is required.

g g

l L1.L2.J I I

i 4 1

80 i

s, 57

% MwER oTHER STATUS ISCO y

DISCOVERY QESCaipTION l

l,,1,,j,,5_j [_E,j@ [019l8lhl NX l.

l A lhl operator Surveillance ACTIVITY CC TENT LOCATION OF RELEASE RELEASED CP RELE ASE AMOUNT OF ACTIVITY l

NA l

l MA

[_Z_j @ [;_J @ l i 6

.o

.4 io PERSONNEL E xPCsyRES NuuSER TYPE DESCRtPTION l

8 lololol@lZl@l NA NA

'2 ERsONsE!',~m', fits oEsCRiPTiCNh l

NuuSER lololol@l NA i a

.o i,

i LOSS OF OR DAYAGE TO FACittTY l

TYPE

DESCRIPTION

IZl@l NA i 9 30 m

3 a 9 10 8101070 Lt

?

NRc uSE oNoy Pu8t >Ciiv l

lllllllIIIIIl$

J ISSUED @ DESCRIPTION W

l NA 2 o 68 69 60= 3 7

a 9 10 NAME OF PREPARER

.- ~