LER-1980-009, Forwards LER 80-009/03L-0
Event date:
Report date:
3011980009R00 - NRC Website

text

"

s$

1 Wisconsin Electnc m came 231 W. MICHIGAN. P.O. BOX 2046, MILWAUKEE, WI 53201

~

i November '25, 19,80

., J Mr. J. G. Keppler, Regional Director Office of Inspection and Enforcement, Region III U.

S.

NUCLEAR REGULATORY COMMISSION 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Keppler:

DOCKET NO. 50-301 LICENSEE EVENT REPORT NO. 80-009/03L-0 POINT BEACH NUCLEAR PLANT UNIT 2 Enclosed is Licensee Event Report No. 80-009/03L-0 (a 30-day report) which provides a description of an event reportable according to Technical Specification 15.6.9.2.B.1,

" Reactor protection system or engineered safety feature instrument settings which are found to be less conservative than those established by the technical specifications, but which do not prevent the fulfillment of the functional require-ments of affected systems."

Very truly yours, C. W.

Fay, Director Nuclear Power Department Enclosure Copy to NRC Resident Inspector

[

.h M04 > 6 *0 -

S 8012090 3 0 6