' January 18,' 1990

., L j

Docket No. 50-412 Mr. J. D. Sieber, Vice President ~

Nuclear Group Duquesne Light Company

-Post Office Box 4 Shippingport, Pennsylvania 15077

Dear Mr. Sieber:

SUBJECT:

BEAVER VALLEY UNIT 2 - COMPLETION OF REVIEW ON PRESSURIZER SUP.GELINETHERMAL' STRATIFICATION (TACNO.-72111)

We have completed our evaluation of the Beaver Valley Unit 2 pressurizer surge line thermal stratification issue. :The. safety evaluation:is enclosed (Enclosure 1).

We based our evaluation on your letters dated January 4, May 16, May 17, and

-August _30, 1989. We also conducted a site audit-August 3-4, 1989, to'obtain-additional information.

(Enclosure 2 is the attendee sign-in sheet for the-exit meeting).

Our_ evaluation concludes that the information provided by you'is compre--

hensive and acceptable. You have made acceptable efforts to meet all-requested actions as delineated in the-NRC Bulletin 8811..Your efforts have demonstrated that based on plant-specific temperature profiles defined by available stratification data on Beaver Valley Unit 2, the surge line meets the ASME Code Section III acceptance. criteria.

This completes our efforts on the' subject issue. The review was preformed by Mr. S. Hou, with contractual support provided by Mr. F._Vasiliadis.

Sincerely,-

Or.iginal signed by Peter S. Tam,_ Senior Project Manager Project Directorate'I-4 Division of Reactor Projects - 1/II Office of. Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBlfTION dN NRC & Local PDRs Plant File S. Varg (14E4)

"B~."BogE(14A2)

S. Norris P. Tam.

S. Hou 9H3)

OGC E. Jordan (MNBB 3302) ACRS (10)

S.' Lee 9H15) 0FC:

LA I-4 PM:PD 4 PD:

4 NAME:

S s

PTa Si JSto DATE:

1/l 90 1//

0 1//K/90

..l OFFICIAL RECORI) COPY DOCUMENT NAME: TAC 72111

(

4 9001250295 900118 J

PDR ADOCK 05000412

\\s i P

PDC

\\\\

i

l.

Mr. J. Sieber Beaver Valley Power Station Duquesne Light Company Units 1 & 2 cc:

Jay E. Silberg, Esquire Bureau of Radiation Protection Shaw, Pittman, Potts and Trowbridge Pennsylvania Department of 2300 N Street, N.W.

Environmental Resources Washington, DC 20037 ATTN:

R. Janati Post Office Box 2063 Kenny Grada, Manager Harrisburg, Pennsylvania 17120 Nuclear Safety Duquesne Light Company Mayor of the Borrough of P. O. Box 4 Shippingport Shippingport, Pennsylvania 15077 Post Office Box 3 t

Shippingport, Pennsylvania 15077 John A. Lee, Esquire Ashley C. Schannauer Duquesne Light Company Assistant City Solicitor One Oxford Centre City of Pittsburgh 301 Grant Street 313 City-County Building Pittsburgh, Pennsylvania 15279 Pittsburgh, Pennsylvania 15219 l

Commissioner Roy M. Smith Regional Administrator, Region I West Virginia Department of Labor U.S. Nuclear Regulatory Commission Building 3, Room 319 475 Allendale Road Capitol Complex King of Prussia, Pennsylvania 19406 Charleston, WV 25305 John D. Borrows Resident inspector Director, Utilities Department U.S. Nuclear Regulatory Commission Public Utilities Commission Post Office Box 181 180 East Broad Street Shippingport, Pennsylvania 15077 Columbus, Ohio 43266-0573 Director, Pennsylvania Emergency Management Agency Post Office Box 3321 Harrisburg, Pennsylvania 17105-3321 Y

h F

I

_