g f '* %

UNITED STATES

'

NUCLEAR REGULATORY COMMisslON

[

(4j

e

nEcion i

C

631 PARK AVENUE

cf

KING OF PRUS%3 A. PENNSYLVANI A 19406

O

-

JAN 9

1981

Docket No. 50-245

Northeast Nuclear Energy Company

ATTN: Mr. W. G. Counsil

Senior Vice President - Nuclear

Engineering and Operations

P. O. Box 270

Hartford, Connecticut 06101

.

Gentlemen:

Subject:

Inspection Report 50-245/80-21

This refers to the routine inspection conducted by Mr. N. Blumberg of this

office on October 27-31, 1980 at Millstone Nuclear Power Station Unit 1,

Waterford, Connecticut, of activities authorized by NRC License No. DPR-21

and to the discussions of our findings held by Mr. Blumberg with Mr. E. Mroczka

and other members of your staff at the conclusion of the inspection.

Areas examined during this inspection are described in the Office of Inspection

and Enforcement Inspection Report which is enclosed with this letter. Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observations by the

inspector.

Our inspector also verified the steps you have taken to correct the items of

noncompliance brought to your attention in a letter dated July 15, 1980. We

have no further questions regarding the steps you took to correct item A.

With

regard to item B this item was not fully corrected.

Based on the results of this inspection, it appears that one of your activities

was not conducted in full compliance with NRC requirements, as set forth in the

Notice of Violation, enclosed herewith as Appendix A.

This item of noncompliance

has been categorized into the levels as described in our correspondence to you

dated December 31, 1974. This notice is sent to you pursuant to the provisions

of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of

Federal Regulations. Section 2.201 requires you to submit to this office,

within twenty (20) days of your receipt of this notice, a written statement or

explanation in reply including:

1) corrective steps which have been taken by

you and the results achieved; (2)(corrective steps which will be taken to avoid

further items of noncompliance; and (3) the date when full compliance will be

achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title

10, Code of Federal Regulations, a copy of this letter and the enclosures will

i

410 4150/T5

.

-.

.

.

.-

.

.- . .

.

.

MS

El

,

,

Northeast Nuclear Energy Co.

2

,

be placed in the NRC's Public Document Room.

If this report contains any infor-

mation that you (or your contractor) believe to be proprietary, it is necessary

that you make a written application within 20 days to this office to withhold

such infomation from public disclosure. Any such application must be accompanied

,

by an affidavit executed by the owner of the infomation, which identifies the

document or part sought to be withheld, and which contains a statement of reasons

which addresses with specificity the items which will be considered by the

Commission as listed in subparagraph (b) (4) of Section 2.790. The information

sought to be withhbid shall be incorporated as far as possible into a separate

part of the affidavit.

If we do not hear from you in this regard within the

specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased

to discuss them with you.

s

Sincerely,

_e

-

E

n J. Brunner, Chief

ctor Operations and Nuclear

R, Support Branch

Enclosures:

1.

Appendix A, Notice of Violation

2.

Office of Inspection and Enforcement Inspection

Report Number 50-245/80-21

cc w/ encl:

E. J. Mroczka, Station Superintendent

J. F. Opeka, System Superintendent, Nuclear Operations

D. G. Diedrick, Manager of Quality Assurance

J. R. Himmelwright, Licensing Safeguards Engineer