Forwards IE Info Notice 81-04, Cracking in Main Steam Lines. No Response Required
ML19350A685
Person / Time
Site: Rancho Seco
Issue date: 02/27/1981
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
References
NUDOCS 8103160654
Download: ML19350A685 (1)


Text

r

!l r areg i !U Io UNITED STATES q

y NUCLEAR REGULATORY COMMISSION co ;

if y

g REGION V f

/

.p 1990 N. CALIFORNI A BOULEVARD M

o, SUITE 202 W 4LNUT CREEK PLAZA o

f WALNUT Cf EEK, CALIFORNIA 94596 ci-

  • ,,,e 4

\\g 5 February 27, 1981 2

gioS h

Docket No. 50-312 3

Sacramento !!unicipal Utility District P. O. Box 15830 Sacramento, California 95813 Attention: Mr. John J. Mattimoe Assistant General Manager Gentlemen:

This information notice is provided as an early notification of a possibly significant matter and it is expected that recipients will review the infomation for possible applicability to their facilities. No response is requested at this time.

If further NRC evaluations so indicate, an IE circular or bulletin will be issued to further recommend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate NCC Regional Office.

Sincerely,

%d R. H. Engelken Director

Enclosure:

1.

IE Infomation Notice No. 81-04 cc w/ enclosure:

R. J. Rodriguez, SMUD L. G. Schwieger, SMUD 810 s 3 gn $59' Q

SSINS No.: 6835 Accession No.:

8011040265 IN 81-04

-s-UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C. 20555 February 27,1981 IE Information Notice No. 81-04: CRACKING IN MAIN STEAM LINES Description of Circumstances:

The Virginia Electric Power Company promptly notified. the NRC on February 23, 1981 that a radiography examination, during the ongoing steam generator replacement outage at Surry Unit 1, had revealed a lengthy crack indication in the I.D. counterbore area of a weldment on the in-line "T" fitting which connects the vertical run of 30-inch piping to the safety relief valve header and 30-inch main steam line of Steam Generator "A".

This piping connection is located outside the containment penetration immediately upstream of the main steam isolation valve as shown in the attached sketch.

A visual and dye penetrant examination on the pipe I.D. surface of the weldment nearest the containment penetration established that the cracking extended about 120F around the fitting counterbore between the 4 o' clock to 8 o' clock position. Cracking was also observed in the weld counterbore at the opposite end of the T-fitting during visual examination of the piping interior.

Radio-graphic examination of "B" and "C" main steam line T-fitting welds disclosed crack indications at similar locations.

Metallurgical specimens of the cracking were trepanned from the T-fitting of the "A" main steam line for analysis. Controlled excavation and depth measurements'of the crack at its mid-length indicated a crack. depth of about 0.090" in this location. The cause of cracking has not yet been established.

~

VEPC0 has planned an ultrasonic examination of similar weldments in Surry Unit 2 main steam lines utilizing " Hot Piping" ultrasor.ic techniques.

Preparations are also being made to ultrasonic examine similar weldments at North Anna Unit 1, currently in cold shutdown for refueling.

Recommendatica to Licensees:

This information is provided as an early notification of a significant safety matter that is still under review by the NRC staff.

It is expected that recipients will review the information for possible applicability to their plants. For those plants having similar main steam line configurations which are currently in a refueling or extended repair outage, it is recommended that a ultrasonic and/or radiographic examination of the three welds and counterbore areas of the T-fittings be performed before resumption of operations, unless some current basis for assurance of piping integrity is available.

d e-MW

IN 81-04 February 27, 1981 Page 2 of 2 No response to this notice is requested at this time.

If you have any cuestions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Attachments:

1.

Sketch 2.

Recently issued IE Information Notices

83 8

S 'v5-f%4.27~. Tuu y /

" h e.ou f

a SA Y Y/4,,9fd Wodg

)

YO

( fd'* *0

/

.4s'aps.g SA? V I,

3 1

&j

.e

~

^/ /S ff 0

to N

p O

+

p(

u r x-w, a

c:- Ga'.

V

._j r,

U SoA/d* ek $o44d6d l

le"

^

g I

wi

~ ~,u e

~

I i

{

"h1wv'=.,,.%.,,,,:4

i e

IN 81-04 RECENTLY ISSUED IE INFORMATION NOTICES Information Date of Notice No.

Subject Issue Issued to 81-03 Checklist for Licensees 2/12/81 All power reactor Making Notifications of facilities with an Significant Events in OL Accordance with 10 CFR 50.72 81-02 Transportation of 1/23/81 All Radiography Radiography Devices licensees 81-01 Possible Failures of 1/16/81 All power reactor General Electric Type facilities with an HFA Relays OL or CP.

80-45 Potential Failure of 12/17/80 All PWR facilities BWR Backup Manual Scram with an OL or CP Capability 80-44 Actuation of ECCS in the 12/16/80 All PWR facilities

/!

Recirculation Mode While with an OL or CP in Hot Shutdown 80-43 Failures of the Continuous 12/5/80 All power reactor Water Level Monitor f or facilities with an the Scram Discharge Volume 6:. or CP at Dresden Unit No. 2 80-42 Effect of Radiation s.

11/24/80 All power reactor Hydraulic Snubber Flux facilities with an OL or CP 80 Failure of Swing Check 11/10/80 All power reactor

' Valve in the Decay Heat facilities with an Removal System at Davis-OL or CP Besse Unit No.1 80-40 Excessive Nitrogen Supply 11/10/80 All power reactor Pressure Actuates Safety-facilities with an Relief Valve Operation to 0L or CP Cause Reactor Depressur-ization OL = Operating Licenses CP = Construction Permits