05000366/LER-1981-009-03, /03L-0:on 810212,reactor Coolant Not Analyzed Once Per 24-h as Required by Tech Spec.Caused by Reactor Vessel Hydro During Time Period When Next Conductivity Measurement Was to Be Taken

From kanterella
(Redirected from ML19350A316)
Jump to navigation Jump to search
/03L-0:on 810212,reactor Coolant Not Analyzed Once Per 24-h as Required by Tech Spec.Caused by Reactor Vessel Hydro During Time Period When Next Conductivity Measurement Was to Be Taken
ML19350A316
Person / Time
Site: Hatch 
Issue date: 03/05/1981
From: Rogers W
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19350A315 List:
References
LER-81-009-03L-01, LER-81-9-3L-1, NUDOCS 8103130460
Download: ML19350A316 (2)


LER-1981-009, /03L-0:on 810212,reactor Coolant Not Analyzed Once Per 24-h as Required by Tech Spec.Caused by Reactor Vessel Hydro During Time Period When Next Conductivity Measurement Was to Be Taken
Event date:
Report date:
3661981009R03 - NRC Website

text

u. sWiEcut ATOnv CommiSSiO 4

,c a,,,,

7 111 LICENSEE EVENT REPORT

~

U CONTROL BLOCK: l l

l l

l l

lh (PLE ASE PRINT OR TYPE ALL REQUIRED INFORMATIONI i

6 [oI d l Gl Al El Il Hj 2 l@l 0 l 0 l - l 0 l 0 l 0 l 0 l 0 l-l 0 l 0 l@l4 l1 l1 l1 l 1 l@l l

[g 7

8 9 LICENSEE CODE le 15 LICENSE NUYtlEH 23 46 LictNSt Type JJ

$1 L A I td CON'T 10% LL_J@l o f 5101 o I o f 31616 IGI O 12 il 12 I e il l@i ci 310 i s l n li !@

I l'l i

5 60 61 D'A K E T NUYD E H 6d bl EVENT DATE J4 75 REPOHT DAT E bJ EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lon 2/12/81, while the unit was in cold shutdown, the reactor coolant l

o 2 j o l3 l l was not analyzed for conductivity once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> as required by l

I o l 41 l Tech Spec 4. 4. 4. c.

This is a repetitive occurrence and was last report-l o 3 led on LER 50-366,/1981-007.

There were no effects on public health and l

I lo is I l safety.

I o 7 I

l IolH] l 60 SYSTEM

CAUSE

CAUSE C OY P.

VA L.V E CODE CODE SUSCOCE COMPONENT CODE SUBCODE SU8 CODE F6Tsl Ic la l@ l xl@ l z l@ I z I z I z I z I z I z 18 [z_j@ tz_j @

7 8

9 10 11 12 13 18 tw JO SEQUENTIAL OCCU R R E NCE REPORT REVISION LE R EVENTYEAR REPORT NO.

CODE TYPE N O.

@,ago!ROIa11l L-J loIoI9I l-l lo 13 I IL I l-l 10 l

,a;

_2n 22 2J 24 26 27 28 29 Ju 31 32 AK N A TO O PL

'T

'ETH HOURS 22 8* IT O FOR 1 B.

5 PL E MAP cA T RER [G_j@lz_]@

l z l@

l z l@

i 0l0l0]

l [Y l@

lN [g lz [g l z l9 l9 [9 [g 33 34 3b 3/

40 41 42 43 44 47 CAUSE OESCRIPTION AND CORRECTIVE ACTIONS h i t 1011 The reactor vessel was being hydroed during the time period when the I

1 i next conductivity measurement was to be taken.

All known sample connec-l 1 tions had been isolated during this time.

A conductivity measurement l

i 2 131 l was made at the end of the hvdro and found to be within limits.

In thel 11 L_fu_ture, the laboratory will be notified to nnke masurcrents prior to vessel hydros.

l 1114i 7

8 3 ST S

% POWER OTHE R STATUS Dis O Y

DISCOVERY DESCRIPTION I1i5I [Hj @ l0 l0 l0 l@l N/A l

l l@l Iaboratory Observation l

ACTivlTY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCAT,0N OF RELE ASE l1l6I LZj @ [_Zj @ l N/A l

l N/A l

7 d 3 10 13 44 45 30 PERSONNEL f XPOst;RES CESCRIPTICN TYPE @l N/A l

NU*.'el E R li171l0l0l0l@l l

  • o

,ERsONd'iNJtS OuCniPr.ON@

NU.er e liIxI!oIoIol@l N/A J

60 7

8 9 11 12 t 055 OF OR O AVAGE TO F ACILtTY iYPE D E ',C RIP TION li 191 Lzi@l N/A l

l 'dlCR,PT,0,@

t ac un aLv Im I sl@L N/A i

ritiiiiiiiriti

, sue

'8108i:30M

.1 T7 367 -7701 g

. m m.orr.,m 2: H i ol.'^."

E LERI:

50-366/1981-009 Licensee:

Georgia Power Company Fccility Name:

Edwin I.

Hatch

\\

Docket f:

50-366

\\

6

NARRATIVE

REPORT FOR LER 50-366/1981-009 On 2/12/81, while the unit was in cold shutdown, the reactor coolant was not analyzed ler conductivity once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> as required by Tech Spec 4.4.4 c.

This is a repetitive occurrence and was last reported on LEL 50-366/1981-007.

There were no effects on public health and safety.

The reactor vessel was being hydroed during the time period when the next conductivity measurement was to be taken.

All known sample connections had been isolated during this time.

A conductivity measurement was made at the end of the hydro and found to be within limits.

In the

future, the laboratory will be notified to make measurements prior to vessel hydros.

l

~s, 9

?

i

.m*

O

^