05000324/LER-1981-029, Forwards LER 81-029/03L-0

From kanterella
(Redirected from ML19347E705)
Jump to navigation Jump to search
Forwards LER 81-029/03L-0
ML19347E705
Person / Time
Site: Brunswick 
Issue date: 05/05/1981
From: Dietz C
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19347E706 List:
References
BSEP-81-0929, BSEP-81-929, NUDOCS 8105130251
Download: ML19347E705 (1)


LER-1981-029, Forwards LER 81-029/03L-0
Event date:
Report date:
3241981029R00 - NRC Website

text

-.

.. s O

__ C~'u y.1 a Carolina Power & Light Company D

C, Brunswick Steam Electric Plant

, I.

P. O. Box 10429

,Ffg 3

- l;,

Southport, NC 28461 g

G f IAIl'2 JSgg b' May 5, 1981 E

Es g FILE: 309-13516 N'*D%.-

SERIAL: BSEP/81-0929 Mr. James P. O'Reilly, Director

[

U. S. Nuclear Regulatory Commission N(p '

Region II, Suite 3100 101 Marietta Street, N.W.

Atlanta, GA 30303 BRUNSVICK STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-324 LICENSE NO. DPR-62 LICENSEE EVENT REPORT 2-81-29

Dear Mr. O'Reilly:

In accordance with Section 6.9.1.9b of the Technical Specifications for Brunswick Steam Electric Plant, Unit No. 2, the enclosed Licensee Event Report is submitted. This report fulfills the requirement for a written report within thirty (30) days of a reportable occurrence and is in accordance with the format set forth in NUREG-0161, July 1977.

Very truly yours, f"

flf(bNjP-C. R. Dietz,' General Manager Brunswick Steam Electric Plant RMP/tc Enclosure I

cc: Mr. R. A. Hartfield Mr. V. Stello, Jr.

ooh 1 1 I {

}

810513 0';;L5I 6