05000368/LER-1981-008, Updated LER 81-008/03X-1:on 810217 & 0310,primary Coolant I-131 Dose Equivalent Value Observed Following Reactor Trip Exceeded Tech Spec 3.4.8.a.Caused by Expected Spike in Primary Coolant Activity Following Trip

From kanterella
(Redirected from ML19347E006)
Jump to navigation Jump to search
Updated LER 81-008/03X-1:on 810217 & 0310,primary Coolant I-131 Dose Equivalent Value Observed Following Reactor Trip Exceeded Tech Spec 3.4.8.a.Caused by Expected Spike in Primary Coolant Activity Following Trip
ML19347E006
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 04/07/1981
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19347E003 List:
References
LER-81-008-03X, LER-81-8-3X, NUDOCS 8104140605
Download: ML19347E006 (6)


LER-1981-008, Updated LER 81-008/03X-1:on 810217 & 0310,primary Coolant I-131 Dose Equivalent Value Observed Following Reactor Trip Exceeded Tech Spec 3.4.8.a.Caused by Expected Spike in Primary Coolant Activity Following Trip
Event date:
Report date:
3681981008R00 - NRC Website

text

.

b)

Update Report-Previous Report Date 3/12/81

\\

l NRC pOnM 3s4 U. 5. NUCLE AR REGULATORY COMMIS&60N j

LICENSEE EVENT REPORT EXHIBIT A

'h CONTMOL OLOct(: l l l l l l l

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI 8 l AIR l Al Nj ol 21@ill 0 l0 l -l0 l0 l 0l 0} 0 l-l 0 l0 lgl4 l1 l 1 l1 l 1 lgl CAT 6eIg

~

l 7

8 9 L,CEN$tt CODg 44 L CEN58 NUp9t A 2%

26 LBCtNil 1.,4 JC bl CON *7

%8

% (1,j@l0 l 5 p l0 l 0l3 l6 l 8 ]@l 012111718 l 11@l 014 l01718 l 11@

60 el oOCaETNUyggn 68 63 EvtNTDaig

,e 76 ut,ont oats so EVENT DESCRIPTION AND PRC8 A8LE CONSEQUENCES to I On two occasions, during Mode Toperation following a Reactor trip from i o 2 100% rated reactor power, a primary coolant Iodine-131 dose equivalent i

o i

i value was observed. exceeding the limit of T.S.3.4.8.a A spike of 1.59 I o a i microcuries per gram occurred on 2/17/81 and a spike of 1.66 microcuries I o s l

o 6 l DAP gram Orrfirred nn 1/1n/A1_

This nccitrrence jg similar tg f_EDag gI 50-368/80-009. Reportable per T.S.6.9.1.9.b.

I r5Til i I

1 2 Z ; 2l 2 :@ $.., ;;g @t,,

Ic i l@ @t@ [: %@ 12 :

y e

w"d e

,c

<2.,e~,,, _,

1 g.

E. D]D.

o wi~,...

I'.?f#,','#

"'Ea"*"

"Cf"'

""d' "

@,"u,,,,o 18111 L-l 1010181 Ld 10 131 L2J L--J L_1J n

2, n

u n

u n

u 2

n oss sa itIngn T

M Tw MOum1 58.i

,09 U,6 su,,

[XJgboN@

hA@

LZJO l0 10101 01 O@

LNj@ [ Zj@ l 219 l 919 l@

T. KIN A

, 23 34 h

M 33 40 el el 43 se e7 CAUSE DESCRIPTION AND CC4 REC flVE ACTIONS 27 gl The specific activity increase was caused by an oxnocted sniko in nri-I m i mary coolant activity following a reactor trip.

The reactor coolant i

, 2 : liquid was processed through the primary dcmineralizers which reduced I

,, i the concentration of radioactive iodine to within acceptable limits.

i e i Additional historical information is attached Der the reauirements of T.1.3.4.8.d

'5Ms' ov-i ituus @

"'d's ?A' c,scovi. o.m.

..o @

s,0.

a LusJ p_j@ 1010l q@l NA l [Aj@l RCS Sample l

Aaivn, can,.,

.=~ r c,.c1,vir, @ l tmm.oso,oa.sc@

. uisio o,ana.s.

[

NA l

L2j @ gj@l NA i o

,,v.so~ lit i.,osseson,,,,,o, @

o.

1,,.

10101 Ol@LZj@l NA l

i >

,.so~~d',v'4n a

ocic...res@

~uo..

10 l 0l0 l@l NA l

i 4 go, ogo,",cr[o.c urv g EB L2J@l NA i

, so,'"@l*"$'ic..,,,o~ @

~

~acUsEoNLv

{Ej NA 1 [t1i1llllllll 2 o Chris N. Shively 5d$/968-2519

,ogo,,,,,,,,,

,,,m 810.4140&oS

.l Attachment to LER 50-368/81-008 Occurrence'Date:

2/17/81 Items 1.& 3.

Reactor Power & Cleanup Flow History Starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to ist sample.in which limit was exceeded

. Iodine DE = 1.59 uCi/GM 2/17/81 0 1515 (Sample time 1312)

Rx Power LD Flow CHRG PWMP

~

1300 100%

<38 GPM

$46 GPM 1400 2

l 2/15/81

~ 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400-2/16/81 0100 0200 t

0300 i

0400 0500 0600 0700 i

0800 0900 l

1000 1100 1200 1

1300 i

q 3.

e i

Attachment to LER 50-368/81-008 Occurrence Date: 2/17/81 Rx Power LO Flow CHRG Pump 2/16/81' 1500 100%

N33 GPM S46 GPM 1600 1700 1800 1900 2000 2100 2200 2300 i

2400 2/17/81 0100 0200 0300 0400 0500 4

0600 0700 0800 0900

'1000, 1100 0%

83 GPM 89 GPM 1 -

1200 38 GPM 45 GPM 1300 1400 1500 0

Attachment to LER 50-368/81-008 Occurrence Date: 2/17/81 Item 2.

Fuel Burnup By Core Region Fuel Type Batch Exposure (MWD /MTU) 1 6383.4543 2

8558.8705 3

10076.9981 4

11735.7655 5

12500.5411 6

11931.9310 7

6657.1972 Core Average 11089.5 MWD /MTU Item 4.

History of Degassing Operation tio degassing prior to exceeding IDE of 1.0 uCi/GM.

Normal letdown / makeup until time of notficiation of

>1.0 uCi/GM.

1 Item 5.

Time Duration of DE I-131

> 1.0 uCI/gm The duration with activity 1.0 uCi/ Gram was approximately 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />.

A sample of reactor coolant was taken at 1312 hours0.0152 days <br />0.364 hours <br />0.00217 weeks <br />4.99216e-4 months <br /> on 2/17/81, showing an activity of 1.59 uCi/gm.

Samples were taken at four hour intervals until activity indicated I-131 DE equal tc 0.69 uCi/gm.

The cumulative operating time at a primary coolant specific activi ty

> 1.0 uCi/gm DE I-131 equals approximately 19 hours2.199074e-4 days <br />0.00528 hours <br />3.141534e-5 weeks <br />7.2295e-6 months <br /> for the last six month period (less than 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> limit of T.S.

3.4.8 Action a).

i i

i f

r

., e

- y

, e a

Attachment to LER 50-368/81-008 Occurrence Date: 3/10/81 Items 1 & 3:

Reactor Power & Cleanup Flow History starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to ist sample in which limit was exceeded.

Iodine DE = 1.66 uCi/gm on 3/10/81 0 0725 hours0.00839 days <br />0.201 hours <br />0.0012 weeks <br />2.758625e-4 months <br /> Time Rx Power LD Flow CHRG Flow 3/08/81 0700 100%

s44 GPM s44 GPM se s/

sr s4' GPM 4

3/09/81 0700 100%

s44 GPM 3/10/81 0240.

5/

- V v

v 0%

s44 GPM s44 GPM 3/

S/

S/

s/

3/10/81 0725 0%

s44 GPM s44 GPM t

6

- + - -

>-----m-

,n,,,,

l Attachment to LER 50-368/81-003 Occurrence Date: 3/10/81 Item 2:

Fuel Burnup by Core Region Batch Exposure (MWD /MTU) 1 6853.9 2

9154.2 3

10822.2 4

12588.2 5

13389.8 6

12758.4 7

7170.2 Item 4:

History of Degassing Operation No degassing prior to exceeding IDE of 1.0 uCi/gm.

Normal letdown / makeup until time of notification of

>1.0 uCi/gm.

Item 5:

Time Duration of IDE > uCi/GM 1

Duration with activity

>1.0 uCi/GM was approximately 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />. A sample of the Reactor Coolant was taken at 0725 hours0.00839 days <br />0.201 hours <br />0.0012 weeks <br />2.758625e-4 months <br /> on 3/10/81, showing an activity of 1.66 uCi/GM. Samples were taken at 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> intervals until activity indicated IDE

<1.0 uCi/GM.

The cumulative operating time at a primary coolant specific activity

>1.0 uCi/GM I-131 equals approximately 29 hours3.356481e-4 days <br />0.00806 hours <br />4.794974e-5 weeks <br />1.10345e-5 months <br /> for the last 6 month period ( <500 hour limit of T.S. 3.4.8 Action a).

l