ML19347C846

From kanterella
Jump to navigation Jump to search
Forwards Safety Evaluation Suppl Re Automatic Initiation of Auxiliary Feedwater Sys & Implications to Positive Reactivity Feedback Resulting from Steam Line Break Accident.Proposed Method & Analysis Acceptable
ML19347C846
Person / Time
Site: Fort Calhoun 
Issue date: 02/20/1981
From: Clark R
Office of Nuclear Reactor Regulation
To: William Jones
OMAHA PUBLIC POWER DISTRICT
Shared Package
ML19347C847 List:
References
IEB-80-04, IEB-80-4, NUDOCS 8103100077
Download: ML19347C846 (2)


Text

..

TEeA o

UNITED STATES

~

8 o

NUCLEAR REGULATORY COMMISSION 3

.,I wAsHWGTON, D. C. 20665

  1. ,a February 20, 1981 Docket No. 50-285 Mr. W. C. Jones Division Manager, Production Operations Omaha Public Power District 1623 Harney Street Omaha, Nebraska 68102

Dear Mr. Jones:

The staff has recently completed the review of Fort Calhoun Station's automatic initiation of the auxiliary feedwater system (AFW) and its implications to positive reactivity feedback resulting from a steam line break accident. Based on our review of your submittals, we find the proposed method and supporting analysis for automatic initiation of auxiliary feed-water to be acceptable.

The results of the staff's review are contained in the attached Safety Evaluation Report (SER) which supplements the SER transmitted to you by letter dated February 2, 1981. Additional supplements to the staff's Feb^ruary 2, 1981 SER will be provided upon completion of our review. Areas which are still under review include the Instrumentation and Control electrical review for both control and safety grade instruments and controls, the consequence of a main steam line break with continuous main feedwater addition (as described in IE Bulletin 80-04), the consequence of a main steam line break concurrent with a station blackout, the evaluation of the containment response resulting from a main steam line break and the review of the information requested in Enclosure 2 of the staff's October 22, 1979 letter regarding Auxiliary Feedwater flow design.

If you have any questions on this subject, please contact your NRC Project Manager.

Sincerely, 6

de

' Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing

Enclosure:

SER on Automatic Initiation of AFW

?gN cc: See next page oj

'07 n

?o,/

. s ir

  • h Q

e f

h 18103100077

- ~ _ -..

~

Omaha Public Power District cc:

Marilyn A. Tebor Director, Criteria and Standards Division LeBoeuf, Lamb, Leiby & MacRae Office of Radiation Programs (ANR-460) 1333 New Hampshire Avenue, N.W.

U.S. Environmental Protection Agency Washington, D. C.

20036 Washington, D. C.

20460 Mr. Emmett Rogert U.S. Environmental Protection Agency Chairman, Washington County Region VII Board of Supervisors ATTN: EIS C0ORDINATOR Blair, Nebraska 68023 324 East lith Street Kansas City, Missouri 64106 Omaha Public Power District ATTN: Mr. Spencer Stevens Plant Manager Fort Calhoun Plant 1623 Harney Street Omaha, Nebraska 68102 Director, Nebraska Department of Environmental Control Mr. Frank Gibson P. O. Box 94877, State House Station W. Dale Clark Library Lincoln, Nebraska 68509 215 South 15th Street Omaha, Nebraska 68102 Alan H. Kirshen, Esq.

Fellman, Ramsey & Kirshen 1166 Woodmen Tower Omaha, Nebraska 68102 Mr. Dennis Kelley U.S.N.R.C. Resident Inspector P. O. Box 68 Fort Calhoun, Nebrask 1 68023 Mr. Charles B. Brinkma l Manager - Washington N clear Operations C-E Power Systems Combustion Engineering, Inc.

4853 Cordell Avenue, Suite A-1 Bethesda, Maryland 20014